| Invoice |
Name |
Invoice Date |
NSN |
Work Completed |
| 4442 | Brendan | 04/14/2026 | 17371 | -replaced broken shutoff above mop sink
-repaired bump bar connector |
| 4441 | Brendan | 04/14/2026 | 10622 | -burning smell caused by bad register ac adapter, replaced all set |
| 4440 | Brendan | 04/14/2026 | 00596 | -repaired broken Ken’s beverage line |
| 4439 | Brendan | 04/14/2026 | 12272 | -beverage install |
| 4438 | Waylon | 04/14/2026 | 10544 | Rewired bypass for cabient so it would stay on without switch gonna order switch
-Reprogrammed grill menu
-fixed latching issue on grill solenoid pneumatic line issue |
| 4437 | Brendan | 04/14/2026 | 16552 | -beverage install |
| 4436 | Brendan | 04/13/2026 | 18198 | -beverage install |
| 4435 | Waylon | 04/13/2026 | 02038 | A bunch of NTF grill was working been using it all morning no one knew it had any problem… landing zone was in use no smoke or problems up to temps |
| 4434 | Waylon | 04/13/2026 | 36960 | Basically waste of time someone called Taylor already without telling any of us so Taylor came out and ordered the part already… and same went for the coke Pm part |
| 4433 | Waylon | 04/13/2026 | 11565 | -got new grill computer from office installed and had to program in missing round eggs clam so believe I got tha all programmed in and all set |
| 4432 | Adanel | 04/12/2026 | 21582 | -upgraded smart clock |
| 4431 | Adanel | 04/12/2026 | 07194 | -upgraded emart clock
-installed uber tablet |
| 4430 | Adanel | 04/12/2026 | 10544 | -upgraded esmart clock
-installed the uber tablet
-new beberage fountain had a leak, i just tighten more it worked
-the pusbar in the door next to the drive thru was a NTF they told me they couldnt close it, i disassembled it and put it back and it was working |
| 4429 | Adanel | 04/11/2026 | 18364 | -half installed the new phone. Need a longer cable! |
| 4428 | Brendan | 04/11/2026 | 07417 | -replaced ABS ice gate |
| 4427 | Adanel | 04/11/2026 | 11565 | -moved all connections from old modem to new
-replaced the store phone |
| 4426 | Adanel | 04/11/2026 | 16552 | -was watching/learning from brendan fixing the bos |
| 4425 | Brendan | 04/11/2026 | 16552 | -bos repair |
| 4424 | Brendan | 04/11/2026 | 04205 | -reimage pos2 |
| 4423 | Adanel | 04/11/2026 | 36960 | -troubleshooted the toaster didnt want to turn on i just tightened the cables and it works! |
| 4422 | Brendan | 04/10/2026 | 10622 | -camera install |
| 4421 | Waylon | 04/08/2026 | 25383 | -installed 3/4 of the enter exit signs removed old and do all electrical work for |
| 4420 | Waylon | 04/09/2026 | 25383 | rGR shenanigans dealing with all scrap metal from signs
Installed last of the exit signs and wired electrical in
Installed muffins toaster part |
| 4419 | Waylon | 04/10/2026 | 10622 | New camera install |
| 4418 | Adanel | 04/10/2026 | 10622 | -Helped doing cameras upgrade |
| 4417 | Art | 04/09/2026 | 02830 | Chemically clean ice machines |
| 4416 | Brendan | 04/09/2026 | 21582 | -replaced UHC switch
-troubleshooted FCB. Changed scraper blades, brixed, and calibrated motor. All working now.
-troubleshooted SSBS leak. O rings failing for a few valves. On order
-walk in cooler “leak” looks like condensation, Rick thinks so too but he’s coming to check it out. If so not gonna be anything you can do unless you spend 50k for a new box
-ordered switch for pie warmer |
| 4415 | Adanel | 04/09/2026 | 18364 | -replaced smart clock and brendan is working on setting it up! |
| 4414 | Adanel | 04/09/2026 | 11565 | -replaced power cord in the frappe machine(took long cause i coulsnt find the little connectors in my van with the mess and i had to go buy some)
-cut back and re crimpped new water connector on frappe machine the line was kinked |
| 4413 | Adanel | 04/09/2026 | 16552 | -replaced coffee brewer's computer |
| 4412 | Art | 04/08/2026 | 02038 | Replaced with new thermostat on cheese cooler had to do some surgery on replacement of thermostat went from an air thermostat to a coil thermostat. |
| 4411 | Brendan | 04/08/2026 | 04205 | -frappe machine they figured out themselves
-Diet Coke lobby NTF |
| 4410 | Brendan | 04/08/2026 | 07194 | -troubleshooted ABS water issue, bad solenoid all set
-repaired filet steamer water line
-programmed and aimed side lobby camera |
| 4409 | Art | 04/07/2026 | 00596 | Little bit of p.m. work on roof double checking ice machine still running well |
| 4408 | Art | 04/07/2026 | 00596 | Working on double door fridge unit notice running little warm. Good to go. |
| 4407 | Art | 04/06/2026 | 02830 | Unit still needs to be cleaned. Found gas I believe in the head. Could not find any leak in the condenser. Added almost 3 pounds of refrigerant. Will monitor how long it takes for a unit to go down again. |
| 4406 | Brendan | 04/07/2026 | 12272 | -lemonade/OJ NTF
-installed dessert butler and removed old equipment
-installed splash shield for McFlurry spinner
-replaced merge monitor present window
-replaced 8 cup fingers |
| 4405 | Waylon | 04/07/2026 | 11565 | -Diagnosed grill bad computer board need to see if office has one
-Fixed filet steamer no water issue had to chase lines around in the basement looks like someone went and shut off the wrong valve to bypass an old pressure booster tank |
| 4404 | Brendan | 04/07/2026 | 25383 | -troubleshooted muffin toaster, needs new relay on order
-replaced armature tip Diet Coke valve
-troubleshooted vanilla syrup shake machine. Bad solenoid on order. Swapped with shamrock for now so vanilla works
-reattached window 1 heater vent |
| 4403 | Waylon | 04/07/2026 | 25383 | -Welded fry station holder bracket
- Welded fryer scoop holder and epoxied welds to water tight seal
-Replaced Hlz cord and plug Rewired |
| 4402 | Adanel | 04/07/2026 | 02830 | -replaced kiosk controller 6 and 9
-replaced esmart clock |
| 4400 | Brendan | 04/06/2026 | 10622 | -met ryan for dishwasher scope |
| 4399 | Brendan | 04/06/2026 | 21582 | -dropped off massive pallets with table in it
-McFlurry shield |
| 4401 | Brendan | 04/06/2026 | 02038 | -register 12 was literally just unplugged… |
| 4398 | Adanel | 04/04/2026 | 25383 | -dig a hole and installed the new mail box
-i did it again, lets hope it doesnt fall🥺😭(lobby laminage) |
| 4397 | Adanel | 04/04/2026 | 02038 | -the push up bar needs tl be replaced, we got 2 at office but its closed rn |
| 4396 | Adanel | 04/03/2026 | 25383 | -replaced window dt monitor
-replaced cash drawer |
| 4395 | Adanel | 04/03/2026 | 25383 | -fixed the boulder to the right of the corral |
| 4394 | Brendan | 04/03/2026 | 10544 | -beverage integration complete
-troubleshooting lemonade not pulling concentrate. Found the lines clogged with pulp. Took apart valve and cleaned out, sanitized lines, and calibrated. All working now
-fixed frappe machine drain pan just needed to clip it back in
-repaired Diet Coke valve in lobby, new armature tip |
| 4393 | Adanel | 04/02/2026 | 36960 | -added new bolts to both front Ped
-reimaged both epr
-troubleshooted the oil vat. Idk if it was me or what but one of the 2 is working right now the other one is gonna get called in for warranty.
-Replaced second window PED, it got tempered again. |
| 4392 | Brendan | 04/02/2026 | 04956 | -reimaged epr2
-replaced both FC drawers |
| 4391 | Art | 04/01/2026 | 02830 | Clean up evaporator and condensers on roof. Also clean walk-in condensing unit and checked the three hoods belt still in good shape greased good to go. |
| 4390 | Brendan | 04/01/2026 | 17371 | -beverage install
-kiosk electrical |
| 4389 | Waylon | 04/01/2026 | 17371 | Ran electrical for kiosk and wired into added box to split between old and new kios and wired up and tested |
| 4388 | Adanel | 03/30/2026 | 36960 | -replaced PED second window it was tampered |
| 4387 | Art | 03/31/2026 | 02830 | Removed old filters, checked belts will return with new filters. May return in morning to clean all coils supposed to be a warm day. |
| 4386 | Art | 03/31/2026 | 00596 | Clean condensers on two coolers found bad thermostat that will be replaced as soon as a new one comes in temporarily jumped out. Cooler is running. Second prep table running well 36°. |
| 4362 | Art | 03/26/2026 | 11565 | Little p.m. inside kitchen and on roof |
| 4385 | Waylon | 03/31/2026 | 21582 | -electrical box smokin? NTF not smoking and not even tied into light pole breakers |
| 4384 | Waylon | 03/31/2026 | 10622 | Installed camera tech in officr |
| 4343 | Art | 03/21/2026 | 07417 | Cleaned ice machine found damaged water, distribution tube and curtain bin switched that needs to be replaced march 21. Return to replace curtain bins. Switch stayed for a couple batches of ice will return one more time when water distribution tube comes in. |
| 4359 | Brendan | 03/25/2026 | 04956 | -replaced piece on shake machine |
| 4335 | Art | 03/20/2026 | 07417 | Cleaned ice machine found damaged water, distribution tube and curtain bin switched that needs to be replaced |
| 4316 | Waylon | 03/19/2026 | 07417 | -dropped off camera supplies from hooksett for next upgrade
-installed grill light lens cut to fit
- tightened tea brewer attachment hoses that was leaking and pressure tested |
| 4383 | Art | 03/12/2026 | 00596 | Change filters belt grease unit where needed on rooftop units |
| 4382 | Art | 03/30/2026 | 21582 | PM filters change belts on rooftop units Greece were needed |
| 4381 | Art | 03/30/2026 | 07194 | P.m. rooftop units filters, belt, greased, and tightened belts |
| 4380 | Brendan | 03/30/2026 | 10622 | -beverage upgrade |
| 4379 | Waylon | 03/30/2026 | 10622 | -installed new beverage upgrade honestly easiest one yet |
| 4378 | Waylon | 03/30/2026 | 02038 | -installed new coffee brewer power cord and new plug |
| 4377 | Adanel | 03/29/2026 | 25383 | -replaced fridge lights
-replaced smart clock
-replaced 2 kiosk controllers
|
| 4376 | Adanel | 03/29/2026 | 02038 | -replaced back door alarm batteries
-re did the tunner bumpbar cable
|
| 4375 | Adanel | 03/29/2026 | 02038 | -replaced back door alarm batteries
-re did the tunner bumpbar cable
|
| 4374 | Adanel | 03/29/2026 | 04956 | -took everything to get the urinal unclugged holly mother of god😭 |
| 4373 | Adanel | 03/28/2026 | 12272 | -replaced 2 kiosks and esmart clock
-ntf on the toaster getting bread stuck
-ntf on the dr pepper
-ordereed 2 monitors for the cameras |
| 4372 | Brendan | 03/28/2026 | 04956 | -troubleshooted bun toaster shutting down. Fan stuck against grate, added washers all set
-troubleshooted oven giving errors. Bad computer. Replaced all set
-fixed beverage printer issues |
| 4371 | Adanel | 03/28/2026 | 11565 | -power cycled the conveyor belt. I think they hyst p u t a heavy load of boxes beflre turning it on and then the macjine tripped when it couldn't start properly. |
| 4370 | Adanel | 03/27/2026 | 11565 | -ntf on the hic
-fixed camera was down
-installed new smart clock |
| 4369 | Adanel | 03/27/2026 | 16552 | -the power cable had tape on it because it was previously cut with something and they decided tape was the best option sooooo it did a short anddddd bye byeee🤣 cut back and reassembled all guchi now |
| 4368 | Brendan | 03/27/2026 | 17371 | -installed new kiosk. Will be back next week to wire power and network and add card reader
-troubleshooted frappe machine was brutallll. The whole water manifold block was bad and clogged and stuff so had to replace
-installed display cast |
| 4367 | Waylon | 03/27/2026 | 17371 | Mounted new kiosk for Lobby still need to do electrical runs and programming but need more parts fist |
| 4366 | Adanel | 03/26/2026 | 11565 | -replaced the files on the sd card in the label machine and it works, it took long because i forgot the sd card readeeeeerrrr in my house so had to go back for it and the to the store again |
| 4364 | Adanel | 03/26/2026 | 36960 | -replaced the lift cylinder on the abs😅 |
| 4365 | Brendan | 03/26/2026 | 04956 | -spent time getting CBB 2 ready BUT some genious at McD doesn’t let you out cbb2 on kvs4. So I had to put everything back to normal and pivot to doing BDAP instead… |
| 4363 | Brendan | 03/26/2026 | 00596 | -NTF cold water in women’s room. Was 105°.
-NTF rootbeer both lobby and drive thru working
-replaced food safety tablet |
| 4361 | Art | 03/26/2026 | 04205 | Found leak at bottom of evaporator, rotted, material, weeping water, not fixable, but does not interfere with the operation of the machine. |
| 4360 | Waylon | 03/26/2026 | 18198 | Sourced and installed new washing machine tested an put old in corral had to wait forever for Lowe’s customer service to help me 😭 got to listen to a lady rant about her water heaters water pressure so I guess that’s cool |
| 4358 | Waylon | 03/25/2026 | 10544 | -installed new grill main computer and programmed then did temp check on 4:1 |
| 4357 | Waylon | 03/25/2026 | 02038 | -Came for coffee brewer power cord originally was said to come next day found out it’s still shipping out of California lmao
-Opened up qing oven not heating up checked fuses and thermal cutouts all good found a magnetron wire popped off tested with on all good and put back together |
| 4356 | Brendan | 03/24/2026 | 02830 | -replaced defective gateway |
| 4355 | Art | 03/23/2026 | 10622 | Clean machine in bin found air assist is barely working. Will order new pump when comes found that freezer was running warm, bad compressor, returned on March 23 to replace compressor running well 10° when I left. |
| 4354 | Adanel | 03/24/2026 | 18364 | -yorgurt wasnt working because the co2 valve was closed
-they claimed the fry station tripped the breaker but i dont know if its true, when i came everything was working, i inpected the cabling and it looked normal so imma put NTF until they call again for it |
| 4353 | Brendan | 03/24/2026 | 00596 | Met scott |
| 4352 | Brendan | 03/23/2026 | 02038 | -beverage install |
| 4350 | Adanel | 03/22/2026 | 02038 | -replaced batteries on speaker and back door bell, now working
-liquid nailed the broken table hope it works |
| 4349 | Adanel | 03/22/2026 | 00596 | -The frozen coke had a "fill error", I reset it just in case. The code popped again and when I checked the line, the whole thing looked like a spring of how twisted it was🤣 they were turning the whole thing when putting a new bag on.
-checked the fillet but NTF they did it themselves, didnt assembled it correctly
-checked the vat and waited until it was workin correctly so NTF
-The dings in the wall, I didnt see anything worth a ticket ngl
|
| 4348 | Adanel | 03/22/2026 | 04205 | -NTF on the lights, they probably fixed it and didnt take it ofd the list
-fixed the flipped eprod monitors
-restarted the coffee pot and it worked😂 |
| 4347 | Adanel | 03/22/2026 | 25383 | -replaced the dish sink faucet(Took longer because when u got here they were using it.) |
| 4341 | Adanel | 03/21/2026 | 16552 | -There was no active leak right now but i checked the drain near the soda machine and there was 2 tubes drain out of place so lets see it was that.
-the abs didnt find any trouble with it, inpected the fan to see if something was hitting it but nothing so until next time |
| 4346 | Adanel | 03/21/2026 | 12272 | -filled all the wholes in the start of the DT imma be called the no arms guy after this🤣 |
| 4345 | Adanel | 03/21/2026 | 02038 | -so you kept reading🤣 i got called for an emergency in which something in the sink was pouring down the floor like a leakkk anddd when i got there a big NTF 🫡 |
| 4344 | Adanel | 03/21/2026 | 21582 | -filled a pothole in our parking side then got called for an emergency keep reading🤣 |
| 4342 | Waylon | 03/21/2026 | 25383 | -installed new exit sign with arrow in marked spot per Debbie request needed electrical ran and wired in which was no fun first time doing one and creating a brace in the ceiling and all the code stuff took little longer than I wanted
-Installed 2 new oep plugs females 30 amp per rgr |
| 4340 | Waylon | 03/20/2026 | 18198 | Drain clogged under McCafé |
| 4339 | Adanel | 03/20/2026 | 11565 | -aimed the camera
-fixed back door, it woulndt latch at all |
| 4338 | Waylon | 03/20/2026 | 10622 | Installed new ice machine water inlet valve washigh key a bitch standing on a table reaching around the machine pushed up against the wall but anyhow replaced vale tested no flooding
I thought it was a hand sink p trap that needed replacing it’s the main dish sink which is 2 inch pipe but I’m not driving an hour for that so when I come back for my parts order I’ll bring the p trap to replace |
| 4337 | Adanel | 03/20/2026 | 36960 | -there a leak on the bellybutton of the abs so needs to be replaced. Took loong to fins out because of how busy the store was sorry+ |
| 4336 | Waylon | 03/20/2026 | 10544 | -installed new lemonade solenoid and valve assembly and tested |
| 4334 | Waylon | 03/20/2026 | 00596 | Abs drain call backing up checked drain fitting for clog of sorts didn’t find anything expanded main and drain longer so the tray drain had more gravity pushing it towards the main dumped 1 gal bucket down it and all set |
| 4333 | Waylon | 03/20/2026 | 04205 | -NTF abs call just a waste of time they’ve been using the abs all morning normal operation |
| 4332 | Waylon | 03/20/2026 | 02830 | -Removed spacers and grouted wall tiles because of how I had to lay tiles spacers didn’t come up right had to cut them an grouted the whole area took a while
-Kiosk programmed in and paired PED
-Coffee brewer plate lose tapped and screwed
-Ice machine cover fell off epoxied the corner back together and screwed back on
-Reconnected zoom timer error on internet loss |
| 4331 | Art | 03/06/2026 | 02038 | Manager walked with me someone had already repaired hinge good to go |
| 4330 | Art | 03/08/2026 | 00596 | Repaired outside freezer door had to replace hinge and grind down bolts drill. New holes working well. |
| 4329 | Art | 03/08/2026 | 00596 | Cleaned and repaired drain pan on freezer and checked to make sure all heat strips are working properly. |
| 4328 | Art | 03/16/2026 | 21582 | Initially looked at small box freezer frozen up like a big ice block. Instructed to let it detour overnight. Found out management contacted Rick‘s refrigeration crew and they were going to look at freezer later that afternoon or the following day which included a rooftop AC heating unit. |
| 4327 | Art | 03/16/2026 | 00596 | Big fridge in front of line double doors had to add refrigerant to unit and clean condenser was running high. Running good now. |
| 4326 | Art | 03/12/2026 | 00596 | S. Willow St. fan was on on reset thermostat and make sure unit fired on heat and cool set to 68° |
| 4325 | Art | 03/09/2026 | 36960 | Clean unit and install installed new start components |
| 4324 | Art | 03/18/2026 | 11565 | High lock rotor amps needs new compressor 290 refrigerant |
| 4323 | Art | 03/18/2026 | 11565 | High lock rotor amps needs new compressor 290 refrigerant |
| 4322 | Art | 03/18/2026 | 12272 | New ice machine, compressor, and ice thickness probe |
| 4321 | Art | 03/19/2026 | 12272 | New compressor, new ice thickness probe |
| 4320 | Art | 03/10/2026 | 00596 | Reset thermostat fan was left on on instead of auto |
| 4319 | Waylon | 03/19/2026 | 02830 | -Installed 5 new big wall tiles around where bottled beverage fridge was old 2 had holes in it but since contractors don’t know how to lay tiles more tiles just kept falling off all had to be custom cut and fit tried to get them to match the old ones with how much they pop out but again that’s because contractors don’t know how to do tiles especially with how they laid on the material from before old tiles literally just fell off th wall 🙄
-Went to install kios computer found out fried it using the wrong cord had to go to Milford and source it from them now waiting for it to program up |
| 4318 | Waylon | 03/19/2026 | 10622 | -diagnosed ice machine which was my emergency abs call flooding the water inlet valve stuck open even with ice machine off jsut kept overfilling and just running water 24/7 made sure solenoid wasn’t calling it wasn’t then went to shut water off the shut off was bad so had to shut off main and replace shut off which was a night mare lik 4 inch space to fit a hand and a tool and just feel what you’re doing ordered new inlet valve
Qing oven was reading door as I walked by ordered new door switches idk why it’s not on the list but whatever |
| 4317 | Adanel | 03/19/2026 | 25383 | -re-did the laminate in the lobby cabinets hopig they dont fall again...😭 |
| 4315 | Waylon | 03/19/2026 | 02830 | -went to install new kiosk computer thought it was the same power cord and well it’s not so that was a massive face palm but got all the install done just needs power cord from Londonderry and then programming
-Coke zero problems on list was an NTF cause they hooked up sweet tea to it 😭
-Women’s bathroom water not temping got it to temp around 110 |
| 4314 | Waylon | 03/18/2026 | 02038 | -Finished installing new side 2 monitor and programmed in |
| 4313 | Waylon | 03/18/2026 | 10544 | - Lemonade only dispensing syrup diagnosed bad / intermittent solenoid valve gets stuck and starts working after you force the lemonade call 3-5 times deep cleaned out the whole valve assembly for it hoping that would help but issue still stuck so gonna order and reoalce solenoid |
| 4309 | Adanel | 03/17/2026 | 25383 | -cleaned the glue, cut the panels that were falling off |
| 4312 | Waylon | 03/18/2026 | 11565 | - back door which sounded like an emergency not closing at all was just the inspector making it sound like one, inspector was not thrilled the door doesn’t close on its own which it hasn’t since we owned the store diagnosed whoever replaced the hinge screws and installed detex used the wrong screws causing it to scrape on door frame and the detex scraping against the screws on the door side
-Installed electrical cover that was missing per inspector
-Rehung fire extinguisher per inspector |
| 4311 | Waylon | 03/18/2026 | 02038 | Door latch is working fine and good enough for now not gonna spend the couple hours installing new vs other emergency calls
Went to install monitor due to the old bracket need metric screws which I don’t carry on me so gonna pick up some of those and come back |
| 4310 | Waylon | 03/18/2026 | 02830 | -Fixed clearance bar dt
-Fixed light core for parking lot light pole
-Went to Londonderry to steal kiosk computer still need to go back and install |
| 4308 | Waylon | 03/17/2026 | 02830 | Honestly over it today replaced electrical outlet for fryers per Casco request saying it was bad wasn’t the problem missing a leg of power took apart breaker panel diagnosed not the breaker so somewhere between plug and breaker lost a whole leg of power went int andul system found the lost leg that fell out of its connector fixed that and then boom still missing a leg but now my outlet has full power diagnosed bad power plug replaced that all fine and dandy went to check my contactor and tiny little 2 inch by 2 inch space shorted my probes and blew one up so rip but fryer is working and all set so that’s cool
-Replaced door das courier sign |
| 4307 | Waylon | 03/17/2026 | 16552 | -Make sure all supplies for contractors were in store for water upgrade and sent photo |
| 4306 | Waylon | 03/17/2026 | 36960 | Unboxed and dismounted fryer from shipping pallet |
| 4305 | Waylon | 03/17/2026 | 18198 | Had to find backup battery for computers which was hidden in tech closet and reset and had to change over office computer port switch reset all computer and were running |
| 4304 | Waylon | 03/16/2026 | 02830 | -Fixed wing oven table bracket
-installed new hinge for bottles fridge by FCB was a job and a half cause there wasn’t enough space to lock the hinge in to gear so had to move everything around
-installed 4 cabinet strips
-installed 1 distribution board for cabinet
-Installed new OJ main board and programmed
-installed new light ballst had to scrap the emergency back up ballast which shouldn’t even exist anyways that took a minute messed with all the normal wiring of a ballast |
| 4303 | Adanel | 03/15/2026 | 02038 | -temporary fixed for the back door |
| 4302 | Adanel | 03/15/2026 | 10622 | -i have no arms...filled 3 massive pot holes in the entrance of the store
-replaced the weather strips |
| 4301 | Adanel | 03/14/2026 | 00596 | -learned about the breakers
-recrimped and fixed leak behind frappe machine
-the water container was dropped so no vapor no heat no anything
|
| 4300 | Waylon | 03/14/2026 | 18198 | -installed stock room ballast and Rewired |
| 4299 | Adanel | 03/14/2026 | 00596 | -replaced and grouted 3 broken tiles
-replaced the egg crate in stock room
-diagnosed the leak on the mopped sink, waylon is going to buy a repair kit for it
-put new screws on the wood in the corral
-stopped the leak from the small stall(it might develop again because its not something still, it moves so yeah)
|
| 4298 | Waylon | 03/14/2026 | 02830 | - honestly decent learning moment mis diagnosed the oj machine and I was so certain on it but I’ve only worked on it maybe 2 times before found out it wasn’t the solenoid bad it was a board telling the solenoid to turn on 24/7 causing the overflow issue rn the solenoid is bypassed so it’s in normal working operation an new board ordered
-ordering distribution board and cabinet strips for cabinet didn’t jump into it trusting the error code for the distribution board
-Double checked electrical on continuity for computer closet plug and all set |
| 4297 | Waylon | 03/14/2026 | 11565 | -Installed new breaker and taught Adanel for menu boards
-Diagnsoed leak for frappe and fixed
-The frappe pitcher cleaner was due to the blown line shut off not working
-moffat water problems seem to be from someone messing with it and it fell off its support bracket store has been tasked with cleaning it but besides that I waited for steam to build up and it to work |
| 4296 | Adanel | 03/13/2026 | 10544 | -used 8 buckets to fill the cracks on the pavement. I only filled 3 holes😭 this needs to be redone
-reset the alarm on office and told them if it pops again to let us know. I waited to see but just in case |
| 4295 | Waylon | 03/13/2026 | 02038 | Installed electrical outlet go closest and removed old shelves |
| 4294 | Waylon | 03/13/2026 | 04956 | Epoxied abs sensor back on told store to wait till 11:30 then they can put back into full use |
| 4293 | Waylon | 03/12/2026 | 02830 | -installed 3 view ports for cameras
-installed 3 display ports for Lobby tvs
-cleaned up and fix tech rack looking like shit
-Finished moving electrical to office and sent photos to Brendan for contractors |
| 4292 | Adanel | 03/12/2026 | 25383 | -replaced the corner guard
-cut and replaced vestibule tiles
-installed the mising tiles total 8
-replaced 4 broken tiles |
| 4291 | Waylon | 03/12/2026 | 18364 | Just brutal between time to pickup washing machine to install and not a single shut off working had to shut the main off to the store …. Which took longer since had to set everything up where the main was only off for 1-2 minutes so nothing else would run dry |
| 4290 | Waylon | 03/12/2026 | 07194 | NTF calls on toaster and creamer all were working when arrived |
| 4289 | Waylon | 03/11/2026 | 00596 | Installed new time clock |
| 4288 | Waylon | 03/11/2026 | 02830 | McDonald’s is being McDonald’s and dumb af so they want the tech closet electrical moved and a 2 inch hole made between the closest so got the hole made had to spend a while removing the electrical outlet need to go back tmrw to re run the electrical since not our electricians fault but he didn’t leave any slack in the line so can’t just casually move it |
| 4287 | Adanel | 03/11/2026 | 11565 | -unclogged dish sink and bath
-replaced light fixture
|
| 4286 | Adanel | 03/11/2026 | 18364 | -agitator and door lock are bad so needs to be replaced on washer or replaced washer |
| 4285 | Adanel | 03/11/2026 | 02038 | -NTF the printer piece was on when i arrived |
| 4284 | Waylon | 03/11/2026 | 04956 | -installed new main board for the cabinet the old cabinets have like 60 wires so takes a minute cabinet is working Mike said he knows how to program so letting him take care of that
-store maintence guy tried fixing the bump bar cable tbh I got no idea what he was attempting but she shouldn’t have been anyways fixed it |
| 4283 | Waylon | 03/10/2026 | 02830 | -diagnosed bad water fill solenoid for OJ machine causing it to spill out the tank and go everywhere |
| 4282 | Waylon | 03/10/2026 | 21582 | -NTF on noise in lobby asked multiple people in store regarding it said it happened one day one time hasn’t happened since
-NTF on side 2 sinks checked both touchless and non touchless showed manager both are working and hot |
| 4281 | Waylon | 03/10/2026 | 10622 | -installed new co2 line that was spraying everywhere by soda pumps |
| 4280 | Waylon | 03/10/2026 | 18198 | -diagnosed Lobby soda not temping needs new compressor start components first before anything else can be checked |
| 4279 | Art | 03/09/2026 | 36960 | Replaced star components |
| 4278 | Waylon | 03/09/2026 | 12272 | Deep cleaned drain line for frappe and pan dumped atleast 6 cups of hot water down it and washed drain pan out |
| 4277 | Waylon | 03/09/2026 | 02038 | -Combed through qingoven put into service mode tested all the feature amp rating were all the exact same which makes me to believe tbh their isn’t an issue but never the less kept combing through it the only component that can start to go bad and make the amp reading similar is magnetrons did couple more test on them tested out fine told the store to keep an eye on it because once the magnetron fully goes bad they’ll notice drastically
-Fire department is pretty stupid wasted time |
| 4276 | Waylon | 03/09/2026 | 18198 | -First time running into this issue for the fry station the sockets neutral terminal for the bulb was destroyed in the socket before the section that went bad so had to replace 2 sockets then found a brand new bulb if you look extremely closely you can see the broken off wire inside the bulb from the factory came bad so that was the icing on the cake |
| 4275 | Adanel | 03/08/2026 | 02038 | -replaced water pump on frozen machine |
| 4274 | Adanel | 03/08/2026 | 00596 | -replaced tank to bow gasket in the big women bathroom, no leaks
-took it out and put it back in and found out that it needs the same gasket but i dont have anymore so have to order it also it needs a new valve(small women bathroom) |
| 4273 | Adanel | 03/07/2026 | 25383 | -replaced light fixture almost got electrocuted🤣
-replaced water valve in bathroom
-lebeled and added toggled to the tablen in crew room(holly pain to do the holes in the ceramic)
|
| 4272 | Brendan | 03/06/2026 | 18364 | -replaced coke tank pressure relief |
| 4271 | Brendan | 03/06/2026 | 02830 | -finished camera upgrades after troubleshooting Waylon’s damaged crimps💀 |
| 4270 | Adanel | 03/06/2026 | 36960 | -replaced coffee maker tank solenoid and filling probe. After that the coffee maker is working like a charm
-replaced the cup extractor, half of it. Ill do the rest when its slower in the store |
| 4269 | Adanel | 03/06/2026 | 18364 | -NTF, Told me the door wasnt Opening after i put the weather strips on it, i went and guessss whyyyyy it didnt want to opeeeeen💀 they didnt clean the snowwwwwwwwww how is it supposed to opeeeeen💀 |
| 4268 | Brendan | 03/06/2026 | 00596 | -internet modem just needed to be rebooted |
| 4267 | Adanel | 03/05/2026 | 17371 | -replaced front door handle
-tightened the dish sink crossbrass
-took pics of homerun cables |
| 4266 | Adanel | 03/05/2026 | 18364 | -replaced weather strip in delivery door |
| 4265 | Brendan | 03/04/2026 | 07194 | -looked at air curtain, need to order new magnetic switch, the one I pulled from from old security alarm is normally closed but need normally open. Also want to add a bypass switch to keep heater on in the winter
-replaced ceiling tile and relocated camera so it wouldn’t be blocked by the new air curtain
-installed new camera for side lobby buttttt forgot my laptop in my car so can’t program it |
| 4264 | Waylon | 03/04/2026 | 10544 | -Investigated water issue flooding store just ice dams from the excessive snow fall and poor design the pipe is broken from roof drains can’t fix till snow melt because the drain itself is covered in ice and backed up |
| 4263 | Brendan | 03/04/2026 | 02830 | -installed camera system stuff |
| 4262 | Waylon | 03/04/2026 | 02830 | -installed new tech rack |
| 4261 | Art | 03/03/2026 | 36960 | Need to replace water trough and curtain and sensor for curtain or bin switch |
| 4260 | Art | 03/03/2026 | 12272 | Clean unit, fixed curtain sensor, clean bin, found that had a bad compressor need to replace compressor |
| 4259 | Art | 03/03/2026 | 12272 | Clean unit, fixed curtain sensor, clean bin, found that had a bad compressor need to replace compressor |
| 4258 | Brendan | 03/03/2026 | 02830 | -beverage install
-build camera tech rack
-put on hinge cover side 2 |
| 4257 | Waylon | 03/03/2026 | 02830 | Beverage upgrades 🙄 |
| 4256 | Waylon | 03/03/2026 | 18364 | -Fixed McDonald’s free wifi
-Left back door weather strip for adanel
-went to emergency bun toaster not working it was just the plug being intermittent ordered new
-Ran line to office computer for finger print reader |
| 4255 | Waylon | 03/02/2026 | 04956 | -Diagnosed cabinet bad main board from the looks of it tested switch transformer and voltage jn |
| 4254 | Waylon | 03/02/2026 | 07194 | -Installed new cabinet switch just trash switches |
| 4253 | Brendan | 03/02/2026 | 12272 | -came for cable modem issue, not plugged in
-breakfast cabinet NTF |
| 4252 | Brendan | 03/02/2026 | 10622 | -cut out sink for warewasher
-replaced frappe base with stripped screw holes so I could replace the drain pan
-replaced ABS umbilical causing cup grab sensor issues |
| 4251 | Waylon | 03/02/2026 | 10622 | -Cut out part of dish sink to fit new dishwasher and filed down sides just need to go back after plumber and electrical to polish the metal |
| 4244 | Adanel | 03/01/2026 | 07194 | -Cleaned and took trash away from tech closet |
| 4250 | Waylon | 03/02/2026 | 18198 | Fixed free wifi |
| 4249 | Brendan | 03/01/2026 | 36960 | -troubleshooted coffee brewer. Fill valve intermittently not opening, part on order
-ABS not giving enough ice. Ice machine making too thick, adjust thickness probe down |
| 4248 | Adanel | 03/01/2026 | 36960 | -got help from brendan diagnosing the coffer maker |
| 4247 | Adanel | 03/01/2026 | 11565 | -installed new cooler below delivery table |
| 4246 | Brendan | 03/01/2026 | 07194 | -troubleshooted flat soda in lobby. Agitator motor in multiplex died, on order
-replaced inlet valve washing machine
-cleared ABS ice bin drain |
| 4245 | Adanel | 03/01/2026 | 16552 | -cut off old modem and waited until the mcdonald's free wifi qas working
-turned on the imb, idk why it was off |
| 4243 | Adanel | 02/28/2026 | 36960 | -replaced label machine |
| 4242 | Adanel | 02/28/2026 | 18198 | -worst one yet ngl. Cleaned and threw away all trash from tech room |
| 4241 | Adanel | 02/28/2026 | 07417 | -Clean out the tech closet |
| 4240 | Adanel | 02/27/2026 | 36960 | -troubleshooted the label machine and it needs to be replaced. |
| 4239 | Adanel | 02/27/2026 | 18364 | -replaced sd card on label machine |
| 4238 | Brendan | 02/27/2026 | 00596 | -went to replace filet steamer solenoid buttttt I accidentally ordered it to office so went there to pick that up and replaced
-replaced office camera monitor and installed viewport
-reaimed outside camera to see CODs
-troubleshooted dish sink hot water pressure. Shutoff valve was just turned off lol |
| 4237 | Brendan | 02/27/2026 | 07417 | -finished beverage install lot of work😮💨 |
| 4236 | Adanel | 02/26/2026 | 02038 | -cleaned trash from tech room and removed shelves and measured it |
| 4235 | Adanel | 02/26/2026 | 12272 | -removed all trash and shelves from tech room also measured it. |
| 4230 | Adanel | 02/26/2026 | 18364 | -Removed all trash from texh closet and measured it |
| 4234 | Brendan | 02/26/2026 | 02830 | -ABS had to bend arm back no big deal
-replaced broken dr pepper nozzle
-fixed erp2 not printing
|
| 4233 | Brendan | 02/26/2026 | 21582 | -replace Coke repressive releif |
| 4232 | Brendan | 02/26/2026 | 07194 | -installed push par on side lobby door
-replaced cup tube on frappe machine
-troubleshooted washing machine, water valve bad not opening all the way, on order |
| 4231 | Waylon | 02/26/2026 | 25383 | -Fixed qing oven door snapped spring
-Fixed cabinet strip not working replaced
-Back door door strip falling off just needed to be recrimped together door strip itself was in good condition
-Made a slight adjustment to fry hopper refrigeration levels from yesterday |
| 4229 | Adanel | 02/26/2026 | 36960 | -replaced abs sensor that stops when drinks land
-replaced the 2 solenoids on the coffee maker but it did not fix the issue i need a part 2 for it. |
| 4228 | Waylon | 02/26/2026 | 10622 | -Replaced 4 cabinet strips 3 front 1 rear second UHC furtherst from Hlz |
| 4227 | Art | 02/25/2026 | 04205 | Two door wall mounted freezer
Added Freon potential leaks testing system temperature came down to low 30s before I left. Needs to be at least 0°. |
| 4226 | Brendan | 02/25/2026 | 11565 | -replaced frappe co2 line and o ring and water armature
-repaired back door push bar |
| 4225 | Waylon | 02/25/2026 | 25383 | -such a useless unproductive dumb day first off snow storm and got stuck in an hour of traffic then got to Milford found out I left my bag in another store so awesome awesome! Had some backup tools tried working with that got fry hopper running down to 20 degrees atm was at 64 they are gonna let me know in the morning what it gets down too
Started working on Qing oven after searching for the box for a while😐 and then boom didn’t even have the right tool after I got it liek 1/2 aprt so yup just a dumb day |
| 4224 | Brendan | 02/25/2026 | 36960 | -replaced ped13 cord and paddle |
| 4223 | Adanel | 02/24/2026 | 10544 | -tried fixing the dt roof pipe leakage. The TY broke and tried to replaced it but everything was put on with saliva and everything fell so gotta come again for that
-fix the temp on hand wash in kitchen
-fixed leakege in hand wash kitchen
-dish sink had a leaked added silicone in the top to stoo the leak
-replaced side 1 3rd strip and 2nd side replaced 3rd and 5th cabine strip |
| 4222 | Brendan | 02/24/2026 | 17371 | -FCB NTF
-replaced 4:1 fridge outlet and plug
-replaced DT1 window lock bar
-relocated closet outlet |
| 4221 | Waylon | 02/24/2026 | 12272 | -Grill both sides off why I’m not sure one side was reading 550 + degrees on display board for every thermal couple I’m thinking it’s an intermittent thermal couple board I swapped the sides to see if the problem follows atm it’s up to temp did temps checked voltage and amp draw all reading good there’s a chance grease got into the fitting and caused it to mess up since I got smothered in it swapping them |
| 4220 | Brendan | 02/24/2026 | 10622 | -replaced time clock
-replace microswitch right coke valve |
| 4219 | Waylon | 02/24/2026 | 21582 | -Looks to be a bad flame electrode do the grill highly intermittent took out and cleaned got it working multiple times while I was here ordering a new one
-unclogged drain pan for abs
-Drain pan drain valve snapped off just by touching the line so had to remove that and replace 😐 |
| 4218 | Waylon | 02/24/2026 | 18198 | -Reset amp switch on cabient
-reassembled chain for window
|
| 4217 | Brendan | 02/24/2026 | 02038 | -repaired ABS, had to adjust sensor because it wasn’t catching small cups and replaced 8 cup tube fingers
-troubleshooted FCB leak, water pump leaking. I have to order but turned off for now to stop leaking
-recrimped bump bar in kitchen
-replaced side 1 HLZ computer |
| 4216 | Adanel | 02/24/2026 | 36960 | -troubleshooted the coffe maker and i strongly believ it has a bad solenoid so part ordered to replace it |
| 4215 | Adanel | 02/20/2026 | 02038 | -camera upgrades |
| 4214 | Art | 02/23/2026 | 02830 | Fixed door closer while I was doing p.m. work at location |
| 4213 | Art | 02/23/2026 | 02830 | Completed 4 PM of location, including ice machines |
| 4212 | Art | 02/19/2026 | 04956 | Replaced water probe at location in dining room |
| 4211 | Waylon | 02/20/2026 | 02038 | -camera upgrades |
| 4210 | Brendan | 02/20/2026 | 02038 | -camera upgrades |
| 4209 | Waylon | 02/20/2026 | 00596 | -Had to pic up and drop off speciality order bathroom door in office basement |
| 4208 | Waylon | 02/20/2026 | 04205 | -fixed light bulb cover for fridge health department
-replaced ceilings tile had to source that were custom cuts left extras with store health department |
| 4207 | Art | 02/19/2026 | 04956 | Replaced water probe at location in dining room |
| 4206 | Art | 02/19/2026 | 00596 | Fixed drain pan in freezer |
| 4205 | Brendan | 02/19/2026 | 10544 | -installed replacement push/pulls for lobby vestibule doors
-ordered cabinet strips
-reimage epr1 |
| 4204 | Brendan | 02/19/2026 | 02038 | -installed network rack and set up network pre work for camera install tomorrow |
| 4203 | Waylon | 02/19/2026 | 02038 | -installed new tech rack with Brendan’s
-mounted servers in rack
-did preparation steps for camera upgrade |
| 4201 | Adanel | 02/19/2026 | 04205 | -re-crimped connector to coke tank it had a leak |
| 4202 | Adanel | 02/19/2026 | 02830 | -replaced dish sink faucet |
| 4200 | Adanel | 02/19/2026 | 21582 | -unclugged the drains behind the frappe machine, snaked, plunged and added the chemical and it worked.
-replaced frappe machine o ring
-this was the main leak, the coffe brewer o ring was bad aswell and it was dripping a lot so replaced and fixed |
| 4199 | Waylon | 02/18/2026 | 00596 | Installed new tech rack
Installed new tech servers in rack
Cable management for all tech rack and extenders |
| 4198 | Waylon | 02/18/2026 | 04956 | -Installed UHc switch
-Installed new slot
-Scoped out camera work dedicidednot to pursue in mid line
-Heloed Brendan mount feet to coffee brewers |
| 4197 | Brendan | 02/18/2026 | 00596 | -Unifi Transition
-replaced frappe machine water connector |
| 4196 | Art | 02/18/2026 | 07194 | Placed start components, clean condenser temp 30° and continuing to come down in temp |
| 4195 | Art | 02/17/2026 | 02038 | Replace sensors and digital controller need to return to replace Yvette fan
|
| 4194 | Art | 02/17/2026 | 02038 | Replace sensors and digital controller need to return to replace Yvette fan
|
| 4193 | Brendan | 02/18/2026 | 04956 | -screwed down beverage riser
-installed legs on coffee brewer
-installed sprayer by tea brewer |
| 4192 | Brendan | 02/17/2026 | 07194 | -installed window 1 air curtain |
| 4191 | Waylon | 02/18/2026 | 07417 | -labeling as NTF on grill had to wait for it to get to temp checked with gapping tool came out fine then went and cooked a 4:1 on it which is what they said they were having problems with came out fine to me sent a video to Brendan he agreed so NTF I will say it could be intermittent motor but until I hear it’s happening regularly I don’t see a problem |
| 4190 | Waylon | 02/17/2026 | 07194 | -Installed new air curtain had to do a ton of frame work |
| 4189 | Brendan | 02/17/2026 | 04205 | Fee for wasting my time. Not only did no other store show up for shake machine class but the maint guy at 2nd st has been in the hospital and nobody thought to tell me. Thanks for wasting my time I love getting up at 5am for people who don't deserve my time |
| 4188 | Art | 02/16/2026 | 00596 | Worked a little bit on walk-in cooler, drain pan and closer for walk-in freezer. |
| 4187 | Art | 02/16/2026 | 00596 | Worked a little bit on walk-in cooler, drain pan and closer for walk-in freezer. |
| 4183 | Adanel | 02/16/2026 | 02830 | -you see it like that too many hours but jolly i went to home depot like 4 times including 3 different home depots
-replaced 2 light lenses
-the women bathroom was fixed already
-the sign needs to be ordered cause we couldn't find it
-ordered a new faucet for the dish sink
-turned the kiosk on it was offlines. Idk how but the poerr cord was barely in the power port of the controller
-replaced thaw printer |
| 4186 | Adanel | 02/16/2026 | 18364 | -fixed the lemonade machine again. Hope it stays like that |
| 4185 | Waylon | 02/16/2026 | 04956 | Installed two new fry sockets seriously needs to be done it’s like 14 gauge wire and no protective sheath at all surprised it’s lasted this long tbh
-Installed new power cord for card reader and protective sheath |
| 4184 | Brendan | 02/16/2026 | 25383 | -fry socket broken, wired very not correctly so corrected that and replaced the bad socket
-troubleshooted frappe machine motor lock. spinner snapped causing motor to jam. on order and also ordered pitcher since the one in use was literally falling apart |
| 4182 | Waylon | 02/16/2026 | 10622 | -installed new washing machine absolute nightmare had to take the whole shelf apart around it and of course it had all the soda syrups on it and a bunch of garbage
-Moved old washing machine to corral
-Fixed wifi for store
-Went to install new drain pan for frappe found screws torn out so needs a whole new base will order
-counted and ordered the strips for cabinets needs 4 front 1 rear about 2 grand 💀 |
| 4181 | Art | 02/10/2026 | 00596 | Had drain pan issue, square it up drain pan should be OK draining OK now. |
| 4180 | Art | 02/11/2026 | 00596 | Working on frappe machine with Waylon
February 13, continue to work on machine from 5:30 AM to 2:30 PM. Had to replace cap tubes. Put unit under vacuum recover all refrigerant. Add refrigerant back in all day project. Still having low pressure issues sent Waylon detailed instructions on what I did. Thanks, Art. |
| 4179 | Adanel | 02/15/2026 | 04205 | -Replaced e product... screen, it was broken |
| 4176 | Adanel | 02/14/2026 | 11565 | -replaced water regulator(what a pain)
-replaced kiosk controller(it gave me like 3 error back to back when try to reimage) |
| 4177 | Adanel | 02/14/2026 | 00596 | -tried fixing the hose but it needs to be replaced in the dish sink |
| 4178 | Adanel | 02/15/2026 | 11565 | -cleaned cup extractor that wasnt closing the arm when picking up the cup, now working fine |
| 4175 | Adanel | 02/14/2026 | 36960 | -NTF abs |
| 4174 | Waylon | 02/13/2026 | 18198 | -Frappe machine not working found only 20 psi in system charged new refrigerant got it to the ideal set point sat with it for a bit till it reached ideal cooling temps their could be a small leak in the system quickly went through the back with my leak detector didn’t get any hints at all tho so gonna check on it when I clock out to make sure they’re set for the weekend |
| 4173 | Waylon | 02/12/2026 | 00596 | -frappe machine with art again he put charge in seems like there’s a clog im still believing the capillary tube is bad and should’ve been done instead of just the filter theirs a slim chance we got a bad epr so having him redo the capillary tube and filter with Taylor one I ordered |
| 4172 | Waylon | 02/12/2026 | 17371 | -installed new grill monitor
-gathered extra Ethernet cable for camera upgrades
-installed new fry socket |
| 4171 | Brendan | 02/12/2026 | 12272 | -water leaking from booster, replaced water line |
| 4170 | Art | 02/12/2026 | 00596 | Working on Prat machine with Waylon. Add to evacuate system and then replaced dryer in cap tubes and pressurized system held for 15 minutes. Will put it under vacuum in the morning. |
| 4169 | Adanel | 02/12/2026 | 12272 | -replaced the bake monitor it was broken |
| 4168 | Adanel | 02/12/2026 | 02038 | -Weird how they keep breaking the tables, fixed |
| 4167 | Waylon | 02/11/2026 | 18198 | -installed new evaporator fan and thermostat valve for prep fridge waited for it to get up to box temp safety had to electrical tape a one time use part that they wanted 150$ to replace so not doing that |
| 4166 | Adanel | 02/12/2026 | 16552 | -troubleshooted the coffee machine and it has a burnt board
-the fc soda machine had sticky armatures so just bang it a couple of times and it worked violence is king!!! Jk🤣 |
| 4165 | Art | 02/11/2026 | 00596 | Working on Prat machine with Waylon |
| 4164 | Brendan | 02/11/2026 | 18364 | -cash drawer 15 not working. Connector dirty with corrosion, scraped off now working |
| 4163 | Brendan | 02/11/2026 | 36960 | -cut back and extended present window bump bar and recrimped |
| 4162 | Brendan | 02/10/2026 | 07417 | -beverage install partial whoever came up with these ideas deserves to be fired |
| 4161 | Waylon | 02/10/2026 | 00596 | Spent the day with art working on frappe machine and brazing in new lines got all brazed done having a problem pulling a vacumn so will have to go back and investigate I think the wrong filter was used tbh… |
| 4160 | Waylon | 02/11/2026 | 07194 | - cut and fit ceiling tile honestly didn’t have much to do no emergencies came in at all and even waited little extra for a last minute breaks nothing was crazy but props to Debbie |
| 4159 | Art | 02/10/2026 | 00596 | Working on Prat machine with Waylon |
| 4158 | Brendan | 02/10/2026 | 12272 | -changed locks to schlage on front doors
-replaced walk-in door closer
-planned for improvements and placed order |
| 4157 | Art | 02/09/2026 | 25383 | PM whole location, including the roof also working on two ice Machines wanna drive up in one at dining room, including last Thursday and Friday I believe which would be approximately 17 hours |
| 4156 | Art | 02/02/2026 | 00596 | This is cumulative time for last week doing p.m. of all equipment, including kitchen, rooftop units and ice machines approximately 8 to 9 hours a day for five days. I will do better on my second week. I wasn’t really thinking about day today hourly charges per location. Thanks. |
| 4155 | Brendan | 02/09/2026 | 07194 | -replaced ABS ice gate but the nut was stripped on it and was an uncommon size so had to run to the store to get it and then replace the ice gate again because the stripped nut stripped the ice gate |
| 4154 | Waylon | 02/09/2026 | 07194 | -had to go into the cabinets found out one of my spare cabinet strips I installed was bad and had to replace another slot found out buttons didn’t work today then had to readdress the cabinets back to factory settings
-Fixed men’s bathroom stall not locking had to grind down
-Fixed door handle for lobby
-replaced weather stripping for door might need a small custom piece for rgr day
- Hung a coat rack for Linda
- McCafé fridge was on the coldest setting and they were complaing about freezing …. So adjusted down gonna check again in a day or two |
| 4153 | Brendan | 02/09/2026 | 10544 | -replaced broken door handle
-measured and ordered two push bar/pull sets for the other side
-replaced OJ door latch
-measured and ordered freezer door curtains for new door |
| 4152 | Adanel | 02/09/2026 | 02038 | -replaced crew room ballast
-they were banging on the mcflurry mixer in order to wrok so it had a loose cable
-put 8 screws on the table 104
-put wallpaper glue on the wallpaper in the lobby |
| 4151 | Adanel | 02/08/2026 | 18364 | -replaced the sink faucet and holly i encounter every problem possible |
| 4150 | Adanel | 02/07/2026 | 36960 | -replaced all the tiles from the list |
| 4149 | Adanel | 02/06/2026 | 18364 | -FINISHED WITH PRINTERRRRSSS! OMG IM SO HAPPY😭😭
-Troubleshooted lemonade and i swaped the headlock with the orange juice one and it fot fixed
-resetted the spooler on beberage printer |
| 4132 | Brendan | 02/02/2026 | 00596 | -new cabinet install
-installed filet steamer parts but in the process the solenoid shorted out so needs a new one on order |
| 4148 | Adanel | 02/06/2026 | 11565 | -replaced moffat probes because there were some error logs
-unclugged female bathrooms. Idk what she ate but hollly theres was a lot of sh*t🤮😭😭😭😭sorry!
-troubleshooted the frozen machine but found a fill error checked spansion tanks but its fine so reseted the error and turned it on |
| 4147 | Waylon | 02/06/2026 | 18198 | -diagnosed prep fridge intermittently has a bad temp control jumped out and got it to kick on compressor and condenser fan ran no evap fan so main issue is that evap fan without it no temp circulation so ordered new fan new fan blade since the plastic is worn out and a new mounting bracket screws are stripped on that and temp control so it’s no longer intermittently running
-died window 1 paddle falling off |
| 4146 | Waylon | 02/05/2026 | 07194 | -installed Qing oven parts new HV board and new front display since they have to match the board service tested pulled proper amperage
-Installed new ceiling vent above dish sink had to get fit sealant for it
-Installed 3 full new cabinet slots from scrapped cabinets
-Sourced new ceiling tiles for Lobby
-finished resecuring McFlurry |
| 4145 | Brendan | 02/05/2026 | 11565 | -looked at moffat. Wasn’t giving me any errors but i checked the error log and it was consistently error on both temp probes. I will order two new probes and hope that fixed the issue
-troubleshooted ABS ice gate fail. Ice gate moving very slow, adjusted up the regulator and drained water from air compressor. Ended up having to replace the ice gate |
| 4144 | Brendan | 02/05/2026 | 04205 | -replaced frappe machine drain pan
-booster not working becasue the breaker was turned off lol |
| 4143 | Adanel | 02/05/2026 | 18364 | -fixed all hand wash temperatures
-configured the printers(need a part 2 to finish) |
| 4142 | Adanel | 02/05/2026 | 16552 | -completed the printers! |
| 4141 | Waylon | 02/04/2026 | 07194 | -installed 6 new wheels cabinet table 4 and 2 for qing voen table
-Installed cabinet switch for cabinet store said we condemned it I can’t remember if we did it just kept blowing through switches a year ago so I amp drawed it and it pulled less then factory max point so can’t see there being a problem besides shitty switches
-drilled out rivets for McFlurry mixer and tested test all good tapped some of the holes but the local Lowe’s doesn’t have 12-24 screws so gotta come back for it
-installed new grill vent clip but the brackets are snapped off so created something to work Brendan is trying to source the massive vent hood part to replace if not not sure what we can do for a permanent solution
Measured vent duct and ordered new replacement |
| 4140 | Brendan | 02/04/2026 | 21582 | -reattached table in lobby |
| 4139 | Adanel | 02/03/2026 | 16552 | -replaced all fc printers, missing kitchen only! |
| 4138 | Art | 02/03/2026 | 00596 | |
| 4137 | Art | 02/02/2026 | 00596 | ice machine PMs |
| 4136 | Waylon | 02/03/2026 | 07194 | - diagnosed Qing oven seems to be a bad Hv board just never seen it go this way so was a bit of a hike to find
-Fixed grill button not working |
| 4135 | Brendan | 02/03/2026 | 02830 | -ABS sensor was broken off, reattached all set |
| 4133 | Brendan | 02/02/2026 | 12272 | -ABS keeps conveyor stalling. Coupling came loose from motor. Replaced coupling and index sensor
-doors are locking they just have stripped keys |
| 4134 | Waylon | 02/02/2026 | 00596 | -installed 2 new cabinet
-Scrapped 3 old cabinets for parts
-Extended 2 power cords
-Moved the cheese fridge down the assembly line |
| 4131 | Adanel | 01/31/2026 | 02830 | -fixed the temperature and preasure of basically alm faucets.
-added the cold line into the back hand washer next to the office idk why it didnt have it |
| 4130 | Adanel | 01/31/2026 | 10622 | -replaced oven outlet and plug after it exploded because somehow the live wired got loose |
| 4129 | Adanel | 01/30/2026 | 12272 | -replaced frappe machine probe
-replaced the light in the back and i got scared because i thought i wireed it wrong but the lights in the freezer were justt dead🤣 |
| 4128 | Waylon | 01/30/2026 | 21582 | Replaced dry socket and recrimped |
| 4127 | Brendan | 01/30/2026 | 18198 | -emergency lobby soda valve broke off and flooding the store. Replaced bad valve, calibrated, and turned on the valves which they had shut off ALL of them |
| 4126 | Waylon | 01/30/2026 | 02038 | - started on freezer refrigeration installed new 3n1 relay that died compressor wouldn’t start installed piercing valve since service valve was stuck closed and then got redirecting for an emergency call in Hanover I believe it needs gas |
| 4125 | Waylon | 01/30/2026 | 07417 | -Installed in fry station 10 gauge wire instead 12 and new grainger switch |
| 4124 | Brendan | 01/29/2026 | 07417 | -multiplex refrigeration but had to call rick we are unsure |
| 4123 | Waylon | 01/29/2026 | 07417 | -first refrigeration fail in a while I THINK the multiplex has a solenoid stuck close causing one side to seem empty of refrigerant and the other to not but I am not sure |
| 4122 | Waylon | 01/29/2026 | 18198 | -Installed multiple egg crate vents cut to fit
-Had to source and install a sign to cover holes by bathroom doors
-Had to go to epping for baby changing station strap which as I previously mentioned was probably not gonna work and it didn’t so cut the strap off my bag and created one to work
-Returned eppings strap
-Covered hole in dish sink
|
| 4121 | Brendan | 01/29/2026 | 21582 | -beverage install
-troubleshooted OJ machine. Bath level low and fill solenoid not working. Will need to order |
| 4120 | Adanel | 01/29/2026 | 21582 | -helped install the new beberage parts in fc |
| 4119 | Waylon | 01/28/2026 | 18198 | -installed new men’s room toilet valves all replaced (sourced)
- back door weather strip frame is severly bent form MB did the best I can with shot notice
-Light lens 2 back stock room and outside walkin
-Corner baseboard tile installed and grouted
-grouted edges of backdoor from rust and bent frame
|
| 4118 | Brendan | 01/28/2026 | 07194 | -troubleshooted iPad. Definitely bad charging port. Will bring spare iPad when I get a chance |
| 4117 | Brendan | 01/28/2026 | 00596 | -replaced sprite armature at ABS
-fixed front door lock sticking really hard to unlock. Took a lot of work but replaced both locks, disassembled cleaned and lubed both head assemblies, and made key copies
-grill arm plate already fixed NTF
-grabbed model number of bathroom buzzer recievers
-troubleshooted filet steamer. Needs a new water tube I’ll order, hi limit just needed to be reset |
| 4109 | Adanel | 01/24/2026 | 36960 | -replaced o ring in the coke tanks |
| 4116 | Adanel | 01/27/2026 | 18364 | -installed all the tiles that were missing and groutted them and cut them.
-installed the faucet in the back sink
-made the water 100* in women bathroom
|
| 4115 | Brendan | 01/27/2026 | 07417 | -replaced FC bottle fridge thermostat |
| 4114 | Waylon | 01/27/2026 | 18198 | -Reset men’s bathroom toilet valve snapped off after wards so needs new valve on order
-Repalced 20 amp oep for qing oven
-did a couple custom cut ceiling tiles
-Caulked door ways and holes through store
|
| 4113 | Brendan | 01/27/2026 | 25383 | -fixed two kiosks not booting
-beverage install
-fixed FC soda tower front keep falling off |
| 4112 | Brendan | 01/27/2026 | 02038 | -ABS NTF… |
| 4111 | Waylon | 01/27/2026 | 18198 | -Installed new ansul caps
-installed new freezer door closer
-installed new office computer monitor |
| 4110 | Adanel | 01/25/2026 | 25383 | -replaced the probe on oj machine
-tightened the bolts of the oven handle
-quing O has a bad handle so ordering one |
| 4108 | Adanel | 01/24/2026 | 18364 | -replaced vga cable from spliter to monitor 2nd window. |
| 4107 | Adanel | 01/24/2026 | 16552 | -finally fixed the bum steamer, replaced the board, screen and switch😭
-the grill its working fine, took temp of reg and qutrp meat and everything is fine
|
| 4106 | Adanel | 01/24/2026 | 18364 | -troubleshooted the grills but idk it just waited for me to get there and didnt do much and got fixed
-stopped the leak to the floor in the back sink but it needs a new solenoid
-replaced a printer |
| 4105 | Adanel | 01/23/2026 | 02038 | -added/tighten bolts to the tables and sitting stools.
-it says that it need to be wleded i put silicone on the sink
-spent sometime messing with the sink its clogged but the tubes are fine, i think that whays wrong its the grease trap its way to full. |
| 4104 | Brendan | 01/23/2026 | 10544 | -washer NTF
-ABS grabbing medium cup NTF
-after multiple trips to the store repaired men’s room trap and tailpiece |
| 4103 | Brendan | 01/23/2026 | 12272 | -troubleshooted frappe machine, needs new temp probe on order |
| 4102 | Waylon | 01/23/2026 | 12272 | -ordered frappe new head temp probe
-NTF on walk-in closer |
| 4101 | Brendan | 01/22/2026 | 07194 | -replaced multiplex ibc control and condenser fan motor
-replaced ped15 cord and paddle |
| 4100 | Waylon | 01/22/2026 | 07417 | -diagnosed upfront fridge found compressor only turning on around 50+ degrees or not at all looked deeper into found a bad control thermistor was stuck open and not powering the compressor will need a little gas but no point in adding now if the compressor doesn’t even stay on |
| 4099 | Brendan | 01/22/2026 | 07417 | -replaced carb A pump that was failed and leaking
-installed new pre filter unit to replace failed one |
| 4098 | Waylon | 01/22/2026 | 18198 | Finished corner trim window 2 |
| 4097 | Brendan | 01/21/2026 | 07194 | -troublshooted multiplex, bath temp sensor bad and water level low. Will replace tomorrow when I get the part |
| 4096 | Waylon | 01/21/2026 | 07194 | -Diagnosed multiplex bad temp sensor |
| 4095 | Waylon | 01/21/2026 | 18198 | -Replace grill table wheel
-caulked bathroom toilet needs a new flange tho so it looks like shit
-Installed strike plate had to specially cut
-Installed new oep
-Installed new blinds reel and chain
-Startedpainting corner strip |
| 4094 | Brendan | 01/21/2026 | 18198 | -cut light lenses
-installed back door strike plate
-installed replacement shock on baby changing table. Even though neither of them needed it…
-caulk men’s toilet
-put screw in window 1 frp |
| 4093 | Adanel | 01/20/2026 | 36960 | -done with the toaster lets hope it doesnt fall anymore🤣 |
| 4092 | Brendan | 01/20/2026 | 18364 | -OJ machine not dispensing water. Verified pressure in backroom. Temp probes very out of calibration. Calibrated temp probes should be all set. Was likely freezing the water |
| 4091 | Brendan | 01/20/2026 | 11565 | -Tea brewer NTF
-espresso machine NTF
-replaced booster motor and pump, fixed some leaks on system |
| 4090 | Waylon | 01/20/2026 | 18198 | - was supposed to train with Will but ig that fell through
-replaced hlz cord
-ordered parts most stuff on lees list gotta source a couple |
| 4089 | Brendan | 01/16/2026 | 04205 | -replaced lobby ice bin |
| 4088 | Will | 01/19/2026 | 18198 | 5 backboard tiles by back door 2 floor tile near kitchen sink 5 floor tiles by office door trained with waylon |
| 4087 | Waylon | 01/19/2026 | 18198 | -Re secured ramp and reinforced for freezer took a while
-trained will on installing tiles and grouting |
| 4086 | Brendan | 01/19/2026 | 04205 | -replaced heating element and infinite control for bottom element in muffin toaster and calibrated
-hooked up Coke Zero stuff
-finished setting up Fanta
-replace booster pump and motor |
| 4085 | Brendan | 01/19/2026 | 21582 | -replaced muffin toaster OEP
-calibrated fry hopper both sides
-fixed grill printer issues wired wrong |
| 4084 | Adanel | 01/16/2026 | 04205 | -replaced the inside of the lobby ice machine like the holder |
| 4083 | Waylon | 01/16/2026 | 00596 | -Topped of frappe refrigeration needs to be repaired for leaks in EPr Fixed leak in valve
-FixedLemondade calibration
-Replaced screws for quarter fridge
-Diagnosed door locking mechanism
|
| 4082 | Adanel | 01/15/2026 | 10544 | -replaced quoter pounder monitor
-crimped the bumpbar cable it was broken
-replaced the door lock outside in the freezer
-handsink was falling so put in placed and caulked it
-Re wired the panel of the automatic window opener idk but it got ripped off do tied the cables back and put it there but smh they lost the wheels so ordered them
-fixed the handicap bottom the metal wasnt making any conection with the battery. |
| 4081 | Brendan | 01/15/2026 | 25383 | -all lobby lights not working, bad breaker. Replaced all set
-OJ machine not cooling. Bad bath temp probe. On order |
| 4080 | Waylon | 01/15/2026 | 04956 | -installed new 4:1 fridge door |
| 4079 | Waylon | 01/15/2026 | 02830 | NTF on grill calls
Fixed back sink shelf falling down
Welded lobby seat
Welded fry hopper rack |
| 4069 | Waylon | 01/13/2026 | 12272 | -Installed new latch switch for grill an tested
-Shorted board fo frappe for lid switch since tha went bad |
| 4078 | Waylon | 01/15/2026 | 07194 | -Installed new fry station socket |
| 4077 | Adanel | 01/14/2026 | 02038 | -replaced and grouted tile
-a fan bent broke so i replaced it |
| 4076 | Adanel | 01/14/2026 | 07194 | -re attached the tube below the dish sin and replaced the water valve, it had a little hole and the loose tube was cause the leak aswell. |
| 4075 | Brendan | 01/14/2026 | 21582 | -adjusted door closers |
| 4074 | Brendan | 01/14/2026 | 10544 | -door issues in lobby were just that the stripped out all of their keys on the keychain they must be so violent with them |
| 4073 | Adanel | 01/14/2026 | 16552 | -replaced steamer tube but after more troubleshooting, the board might be dead. Theres power going to it but nothign is showing/working. |
| 4072 | Adanel | 01/14/2026 | 11565 | -troubleshooted kiosk and ssd was bad and need to be replaced so i grabbed the other bad kiosl and grabbed the ssd and placed it in the bad one and now we got a whole kiosk working
-replaced syrup deflector on abs front counter |
| 4071 | Waylon | 01/14/2026 | 17371 | -Fixed door closer on back door
-replaced weather strip back door
-Fixed lobby light bulb |
| 4070 | Adanel | 01/13/2026 | 36960 | -rebuild a lot of broken bib parts
-drilled holes for the new beberage braket |
| 4068 | Brendan | 01/13/2026 | 04205 | -rebuild a lot of broken BIB parts
-beverage sprayer install |
| 4067 | Waylon | 01/13/2026 | 07417 | Freezer was defrosted so adjusted pressures got down to -04 |
| 4066 | Adanel | 01/12/2026 | 36960 | -replaced and grouted more than 10+ broken tiles
-the leak in the dish sink needs a new valve
-put back the crew room door shield.
|
| 4065 | Brendan | 01/12/2026 | 07194 | -beverage install |
| 4064 | Waylon | 01/12/2026 | 17371 | -Installed new vent and attached hvac duct
-installed new breaker and load tested
-put a temporary fix on weather strip back door gonna replace full strip before rgr
-caulked holes in mop sink to get them by for time being
-ordered new Chain and gear for bun toaster
-installed new light lens for by delivery door
|
| 4063 | Adanel | 01/09/2026 | 18364 | -replaced kiosk 6 card reader
-reattached the metal sheet to the freeser doors |
| 4062 | Adanel | 01/09/2026 | 16552 | -i got stuck ngl fixing the steamer, but its fixed now and it needs a new hose.
-restarted the menu board controller and its working
-installed the new coke zero tap pad, the old one wasnt working |
| 4061 | Brendan | 01/09/2026 | 18364 | -repaired backflow |
| 4060 | Brendan | 01/08/2026 | 02830 | -reimaged pos1
-ped15 that wasn’t working was just unplugged from network
-replaced dogging mech
-adjusted temp of bathroom sinks. Had to install mixing valve in womens |
| 4059 | Adanel | 01/08/2026 | 11565 | -went to the office ang got the cables and ab switches
-troubleshooted the kiosk and i think its malfunctioning in someway because it sipposed to be giving me 25v in order to maje the lrinter work but this one its only giving me 20v and its not turning on, the other kiosk need reimage.
-replaced all parallel printers for the usb ones |
| 4058 | Waylon | 01/08/2026 | 00596 | Charging an hour for the door drama and phone calls to get this bathroom door ordered |
| 4057 | Waylon | 01/08/2026 | 04205 | -Fixed grill airline fitting on air solenoid somehow fell off resecured and tested couldn’t do meat temps because store lost tethlon I guess????
-Ordered part for muffin toaster fuse holder loose |
| 4056 | Brendan | 01/07/2026 | 18364 | -installed new mop sink
-replaced dish sink hose and sprayer
-looked into flow problem. Repair kit on order |
| 4055 | Adanel | 01/07/2026 | 10622 | -the washer had a leak on thr two eay connector, fix that one, then it had another one on the hose replaced the hose and added new gasket and now its working fine
-took a piece floor and ceiling tile to buy a couple to replaee when im back |
| 4054 | Waylon | 01/07/2026 | 18364 | Installed new mop sink |
| 4053 | Waylon | 01/07/2026 | 00596 | -installed new fan motor and fan blade do frappe machine
Wasn’t coming Dow to temp checked pressures was at 20 psig should be around 45 so added gas checked waited to go down to temp miscommunicated with Taylor so Doug showed up as I was finishing and he checked the EPRs with me but besides that all set and fixed |
| 4052 | Adanel | 01/07/2026 | 17371 | -that door has to be made out diamond, way to hatd to make holes but installed the fridge door closer
-put the screws back in the delivery door push up door
-put some screws on the threshold in freezer
-NTF on the urinal clogged |
| 4051 | Waylon | 01/07/2026 | 00596 | -Reprogrammed cabinet needs a new main board I believe there’s a spare at the office from scrapped cabinets
-Fixed filet steamer water line dripping water |
| 4050 | Adanel | 01/06/2026 | 00596 | -grouted infront of ice machine, sink under hand washer in the back also a little bit on the entrance near the office.
-put up the pay here sign that fell. |
| 4049 | Waylon | 01/06/2026 | 00596 | -Snaked kitchen sink drain 3 time and draino coild not get clear have Ryan from east coast coming out tomorrow
-Custom cut and fit men’s bathroom door installed new door lock and had to dremel down strike plate
Any other side rgr shenanigans |
| 4048 | Adanel | 01/06/2026 | 36960 | -replaced all the gears inside the bun toaster including the chain and it wasnt the issue i took forever for me to figure it out but it was a worn retainer inside the roll that was allowing the roll to come all the way out. Ordered the part and for now i put a rubber and metal thingi to stop it from coming out. |
| 4047 | Brendan | 01/06/2026 | 00596 | -repaired another Dr Pepper line yet again, this time it was at the multiplex though
-replaced men’s bathroom door |
| 4046 | Adanel | 01/05/2026 | 00596 | -helped replaced mirror
-replaced and grouted 3 tiles
-there were some dark spot of tiles i smothered them down
-replaced water waste pump under soda machine in lobby(what a draggggg)
|
| 4045 | Waylon | 01/05/2026 | 00596 | -hlz needed a fuse store keeps playing with power cord caught to trip pretty sure it’s night side
-Reprgrammed all middle cabinet and had to replace a full slow
-Took apart hand sink waiting on parts for tmrw
-installed new mirror for men’s room
-replaced dish sink sprayer hose
|
| 4044 | Brendan | 01/05/2026 | 00596 | -replaced another section of Dr Pepper line
-replaced Dr Pepper bib pump
-cosmcs install
-replaced cbb bump bar |
| 4043 | Brendan | 01/05/2026 | 02038 | -replaced dt present monitor |
| 4042 | Jim | 01/02/2026 | 00596 | - cleaned floor tile edges in between the bathrooms
- replaced and grouted floor tile on savers side of lobby
- installed new wall tile behind south willow side trash bin
|
| 4041 | Adanel | 01/02/2026 | 36960 | -NTF on the coffee and back sink. |
| 4040 | Adanel | 01/02/2026 | 00596 | -aimed camera in lobby
-jim did all the tiles in lobby
-meaused and cut the tiles sink and soda area in the back
-drilled out the screws from the main door and teplaced the weather strip
-installed the freezer lights and added a bulb aswell
-fixed all the corral woods coming out. It was like 10 of them, i was freezing
-lemonade was not working so i took the pump apart and did a deep cleaning just in case it was clogged and learned how to calibrate it
-attached the metal part of the side of the building
-troubleshooted the pump under lobyy soda and its dead its just homming like there's no life |
| 4039 | Adanel | 12/31/2025 | 36960 | -toaster chain fell so i put it back |
| 4038 | Adanel | 12/30/2025 | 00596 | -it wasnt the frame that was comming off it was the weather strip so replaced
-replaced batteries and made the water come out hot on soap and had washer
-Tried fixing the metal outside of the door it was attached then when i came back it was bad again, it has damage so need to be bended back
-caulked behind the shake machine, under crew room and back dish sink
-replaced light lense
-replaced light fixture above dish sink
-ordered 2 light cover for freezer
-metal part infront of dish sink was comming off so i out back
-tighten the screws on the fridge in second window |
| 4037 | Adanel | 12/29/2025 | 36960 | -replaced 4 bun rackets wheels
-front abs needs a diffuser so the sirup comes out with the water and soda
-turned on kiosk |
| 4036 | Adanel | 12/29/2025 | 16552 | -i think i spent too much time trying to find the leak and at the end there are 3 leaks and their source is no where to be found. Walyon and i are going to give it a secodn try on Wednesday to see whatsup
-ordered hi limiter and relays, the steamer keeps tripping the hi limit
-ordered button pad for the coke zero soda machine |
| 4035 | Adanel | 12/29/2025 | 36960 | -did a clean on the abs ice machine and its working now
-The abs was not making soda automatically, the serial hub was off in the back
-the bun toaster fan was dirty so i cleaned it and its working now |
| 4034 | Brendan | 12/29/2025 | 02038 | -ABS is fine. Literally all they had to do was dry the sensor with a dry napkin what a waste of time
-McCafé machine NTF as well sounds like they didn’t have the drain hose in the drain…
Charging double for wasting my time |
| 4033 | Brendan | 12/26/2025 | 10544 | -installed new label maker
-replaced two camera spot monitors and set up |
| 4032 | Brendan | 12/26/2025 | 04956 | -replaced UHC switch
-oven currently working so will order controller just in case for next time |
| 4031 | Waylon | 12/26/2025 | 04205 | -installed new latch switch in grill
-installed new motor and they installed belts wrong for muffin toaster and had severe lack of cleaning problems
-installed new women’s handicap stall flush valve tested and found no leaks |
| 4030 | Brendan | 12/23/2025 | 10544 | -camera upgrades |
| 4029 | Waylon | 12/24/2025 | 04205 | -Diagnosed bun toaster needs a new motor receiving 208 not budging and replacing chain also
-Diagnosed women’s handicap stall needs new plunger valve |
| 4028 | Brendan | 12/22/2025 | 10544 | -replaced dish sink spreader and hose
-replaced vzn filters
-started camera upgrades |
| 4027 | Adanel | 12/22/2025 | 16552 | -resetted the hi limiter on the filet toaster
-NTF on the oj machine
-rebooted eprodcution, it didnt passed to lunch |
| 4026 | Adanel | 12/22/2025 | 12272 | -was looking for the leak and didnt find anything, i sat in a corner behind the frappen machine to see everything and i saw a drop deopping every like 1 minute. Fixed that lets hope that fixes the leak |
| 4025 | Waylon | 12/22/2025 | 25383 | -filet steamer I assume it’s a loose power switch was turning off everytime they used it so replaced power switch and recrimped all the wires with new terminals since any loose connection could’ve caused this then messed with it a little roughly to make sure it stayed working which it did so should be all good |
| 4024 | Brendan | 12/22/2025 | 02038 | -ran new smoothie water line |
| 4023 | Waylon | 12/22/2025 | 00596 | -Had to come out here to get the dumbo at Kamco certain measurements again even after I sent him like every possible photo of a measurement and he responded with 20 questions 5 days after the email like talk about inconvenience |
| 4022 | Brendan | 12/19/2025 | 16552 | -new frappe machine install |
| 4021 | Waylon | 12/19/2025 | 02830 | Muffin toaster has a fan on the way out / super duty wasn’t running when I arrived pulled out deep cleaned with dis sprayer and it kicked on after a little ordering a new one to store just in case |
| 4020 | Waylon | 12/19/2025 | 04205 | -Diagnosed grill bad latch switch you can tell it’s bad cause when pressing a switch typically hear the clicking of it but this switch can be pressed dow but never makes the full connection
Going to order 2 and replace both since getting at the switch takes a lot of work and don’t wanna do one a month from now both switches physically look to be in very bad shape switch thas bad is snapped in half |
| 4019 | Brendan | 12/19/2025 | 18364 | -The gauges on the co2 tank and to the coke tank were dead and someone adjusted the 65psi regulator to like 100 so it blew the coke tank and they also had a bad tank lid and co2 connector. So in all replaced pressure relief, two gauges, tank lid, co2 connector, and adjusted regulator properly. Now a healthy happy store! |
| 4018 | Adanel | 12/18/2025 | 12272 | -the problem was the ice drain that it was clogged that why a lot of water in the floor |
| 4017 | Adanel | 12/18/2025 | 16552 | -ntf on the plug of the oj machine
-reveived the frappe machine and got it inside |
| 4016 | Adanel | 12/18/2025 | 18364 | -tried fixing the door, i put wd40, lifting it up but nothing. Might need a contractor for that one |
| 4015 | Adanel | 12/18/2025 | 04205 | -replaced 2nd window PED |
| 4014 | Brendan | 12/17/2025 | 10544 | -built tech rack
-remediation
-repaired burst tube leaking inside multiplex
-calibrated sprite at ABS |
| 4013 | Waylon | 12/17/2025 | 10544 | Assembled tech rack for tech install tonight |
| 4012 | Waylon | 12/17/2025 | 11565 | Required electrical for basement light got the whole fixture working and safe
-Oven tripped breaker store dumped water all over plug so obviously didn’t work waited couple hours plugged in all set
-Welded part of the fry vat
-tried installing new mirror found out different mounting device sadly |
| 4011 | Brendan | 12/17/2025 | 11565 | -replaced OJ button pad
-rekeyed basement detex to same as upstairs
-booster motor dead, need to replace bypassed for now
-recrimped grill screen bump bar
-bought a new faucet to replace dead one in men’s room but it was DOA, al they actually had an extra one in the store so I used that to get them going
-adjusted temp of both men’s faucets
-mirrors from office are the wrong style so oh well |
| 4010 | Waylon | 12/17/2025 | 21582 | -Replaced two fry sockets on fry station found one of the shit designed versions of them shorting the wire tripping the breaker everytime found out it was day before RGr and they had to make something work so can’t blame them |
| 4009 | Waylon | 12/16/2025 | 18364 | -Replaced HLZ outlet burnt of had to replace HLZ wiring and replace computer still need to come back for proper plug to be inatalled |
| 4008 | Brendan | 12/16/2025 | 04205 | -replaced pos14 due to failed touch screen |
| 4007 | Waylon | 12/16/2025 | 18198 | -Scraped both cabinets in lee and rolled out to corral (crew wants the cabinets so they can take care from there)
-Double checked co2 signs and alarms with Jamie |
| 4006 | Brendan | 12/15/2025 | 04956 | -had to relocate my stuff on the tech rack per McD unfortunately, had to extend all the camera wires and everything what a pain |
| 4005 | Brendan | 12/15/2025 | 02038 | -repaired frappe machine kind of. There wasn’t a shutoff out back for it and the line is very deteriorated. I need to replace the whole line but don’t have enough on me plus need to shut off all water so I will come back another morning to rerun that |
| 4004 | Waylon | 12/13/2025 | 07417 | -Installed 5 new fry sockets and redid all the wiring inside after the switch |
| 4003 | Waylon | 12/15/2025 | 18198 | -Lee new cabinet installed brought old out back to be scraped for parts |
| 4002 | Waylon | 12/15/2025 | 17371 | -Fixed dish sink sprayer and hose broken
-Muffin toaster airflow error cleaned out fan and vents store is supposed to keep us posted on how it goes
-Wall bowing out from MB truck hitting it fixed and all set |
| 4001 | Brendan | 12/15/2025 | 21582 | -ABS grip sensor fail. Syrup in connector, cleaned out with contact cleaner all set |
| 4000 | Adanel | 12/13/2025 | 16552 | -checked the oj, and its qorking fine
-placed a new power strip because the old one kept tripping the braker |
| 3999 | Adanel | 12/13/2025 | 21582 | -did all fc PEDs
-learned how to deal with ABC |
| 3998 | Adanel | 12/13/2025 | 11565 | -replaced O ring in the frappe machine
-sanded down the wall and it came out pretty gud |
| 3997 | Waylon | 12/12/2025 | 25383 | -NTF filet steamer
-Kiosk needs key store doesn’t have jsut need computer turned off and on |
| 3996 | Brendan | 12/12/2025 | 21582 | - |
| 3995 | Brendan | 12/12/2025 | 00596 | -grill NTF
-OJ NTF
-replaced detex battery
-replace bump bar connector |
| 3993 | Adanel | 12/11/2025 | 11565 | -sanded down the holes i did last time
-filled 2 biggggg holes in the basement i still need to sand it down but the mud said 25 minutes dry and its been hours
-replaced a broken wheel on toaster
-unclugged men urinal
-put the missing nut on the door going to roof
-isntalled a new co2 alarm |
| 3994 | Waylon | 12/11/2025 | 11565 | -moved basement co2 alarm to spot Carlos wants
-Installed bracket for co3 back up tanks
-fixed water for men’s faucet
-NTF on grill store turned off and back on no problem since |
| 3992 | Brendan | 12/11/2025 | 04956 | - |
| 3991 | Waylon | 12/11/2025 | 07194 | Grill 3 home switch not seen error NTF talked with manager on shift says she hasn’t had a problem for 5 days would be nice if the store said it’s been perfectly fine since then lmao I asked how it was cooking to make sure nothing was actually broke |
| 3990 | Waylon | 12/11/2025 | 00596 | -Gotta be top 10 dumbest shit ever, police knocked down the men’s bathroom stall door to the point of unfixabke and now I’ve been playing phone tag with Kamco to see if they can get something on order and had to go talk to them in person hopefully they can get something done about it but what a waste of time due to homeless people like get a life |
| 3989 | Waylon | 12/10/2025 | 17371 | -Installed 2 new cabinet removed both old put one in my van for lee and the other was complete garbage scraped all good parts out of it
Installed 4 new card readers for 2 kiosk 2 fc
Couldn’t diagnose fcb since they didn’t have any syrup in the store to test
|
| 3988 | Waylon | 12/09/2025 | 18198 | Installed new hard drive for camera system |
| 3987 | Waylon | 12/09/2025 | 36960 | -RGR small things grouted in front of fry station 8x4 area
Finished tiling and grout mop sink tiles
-Looked at grill platen 3 down needs new transformer but Taylor has warranty for so they are fixing
-Any small other things |
| 3986 | Brendan | 12/10/2025 | 17371 | -installed new UHC
-p400 upgrades complete |
| 3985 | Adanel | 12/09/2025 | 11565 | -I tried fixing it, i really tryed. But no luck. Thr bolt snapped, the tap maker snapped, at the end i got it to make the correct amount, it wasnt overfilling but the ice was incorrect i callled and nothing. No help at all. |
| 3984 | Brendan | 12/09/2025 | 18364 | Literally no comment |
| 3983 | Brendan | 12/09/2025 | 16552 | -removed cabinet in office to make room for tech rack🙃 |
| 3982 | Brendan | 12/08/2025 | 04956 | -Beverage 2026 install. Need to come back to screw down riser |
| 3981 | Waylon | 12/08/2025 | 36960 | - spent a while on a bunch of tiles multiple cut ones mostly on corners of the store and grouted most of the tiles mop sink tiles are setting up gonna grout in the morning with the rest of the grout I have to do |
| 3980 | Brendan | 12/08/2025 | 36960 | -new fryer install
-replaced first window handle
-adjusted second window thumb latch
-troubleshooted frappe machine having issues with caramel. replaced the pump assuming that was the issue but when that didnt work I found that there was a clog in the line from the pinch valve to the dispense head. Then I realized there was ice clogging the hole on the dispense head which led me to find the issue that the dispense head is 23 deg which is the problem. called into Taylor |
| 3979 | Adanel | 12/07/2025 | 11565 | -painted the caninet under sink
-filled 2 holes that left me with no right hand😭
-cut out the two other holes that i need to fill, the store is kinda garbage when it comes to that.
-installed 5 tiles and grouted them |
| 3978 | Adanel | 12/07/2025 | 11565 | -made a little cabinet under the hand washer so they dont steal the fuset's part |
| 3977 | Adanel | 12/06/2025 | 18364 | -the splenda little rottor wasnt going all the way into the motor because it had a lot of splenda all around it. So cleaned it up and its working
-the sweet tea i just did a flush and its getting sweet
-the sprite has a problem either with the solenoid or the flow control spring |
| 3976 | Brendan | 12/05/2025 | 25383 | -fixed kiosk 7
-replaced pos1
-repaired dt abs Fanta, replaced solenoid
-installed delivery tablets
-cleared out old ORB junk |
| 3975 | Waylon | 12/04/2025 | 36960 | -installed new light to crew room
-Installed a second new light for crew roo
-Fixed fry station and had to drill out for the right spoke
-Repalced OEP in grill
-diagnosed grill and called Taylor
Broke of some baseboard tile to get it matched and sourced |
| 3974 | Waylon | 12/04/2025 | 07417 | -RgR stuff
-Grouted couple areas
-Foujd hinge cover for store
-Fixed dish sink cold water valve broke and not giving any cold water
-Tried to fix a piece of lobby window top falling wasn’t successful in the slightest |
| 3973 | Brendan | 12/04/2025 | 10544 | - |
| 3972 | Brendan | 12/04/2025 | 02038 | -removed music system from tech closet per MAPS |
| 3971 | Brendan | 12/03/2025 | 25383 | -replaced ped15 power cable, multi port cable, and paddle
-tech rack relocated equip to meet standard |
| 3970 | Waylon | 12/01/2025 | 00596 | Grill 3 gappingissue and platen getting stuc of cover shield
grill 1 gapping cooking issue found broken belt replaced and food safety it
-Qing oven needing all new screws died and tested |
| 3969 | Waylon | 12/03/2025 | 07417 | -Installed new table heater and tested
-grouted multiple areas
-cleaned up fryer magnet gonna order new
-Installed women’s handicap stall water flow valve
|
| 3968 | Brendan | 12/03/2025 | 07417 | -replaced side 1 heat pad
-replaced men’s room flusher |
| 3967 | Brendan | 12/01/2025 | 02830 | -troubleshooted FCB. Replaced left barrel expansion tank and recalibrated barrels 1 and 3
-replaced fc card reader upgrade
-replaced hlz transformer
-troubleshooted doorbell. Cleaned off contacts outside and had to readjust the innards of the bell |
| 3966 | Waylon | 12/01/2025 | 04956 | -Grill gapping issue adjusted 3/4 blocks and the 4th one snapped my Allen in half so that was dumb af and stripped out the block so needs a new gapping block for the time being got it so it’s not destroying the meat like pancakes and got it to be food safe by adjusting the other gaps |
| 3965 | Brendan | 11/29/2025 | 10622 | -reimaged kvs4 |
| 3964 | Adanel | 11/30/2025 | 11565 | -installed the last light fixture
-replaced the hand washer pump
-troubleshooted the frappe machine, needs new regulator
-frappe machine replaces the o ring and the water jose was kinked so cut back and did it again.
-was taking somr pics of freezer and doing some investigation about it. |
| 3963 | Adanel | 11/30/2025 | 18364 | -replaced kiosk PED |
| 3962 | Adanel | 11/29/2025 | 36960 | -started by replacing the ballast and sockets on the basement light that was out, left it working and about an hour later i came down to pick up a ladder and the the right side was dead and i was like nooooooo. So i bought a new light and guess what? It came broken.
-Scariest moment of my life😅 i was troubleshooting the hand dryer and i replaced the board, sensor and heating element. When i went yo connect the live canle holly sparks. I jumped back like a monkey but i got it to work. Seconf time idk how but the heating element went baf aswell. I got pictures to prove i connected everything correct
-Replaced 2 light fixtures
-fixed 2 of them that were like bent.
-also police came looking for somethigb so i gave them my phone so they can look thru the camera |
| 3961 | Brendan | 11/26/2025 | 36960 | -reimaged epr controller |
| 3960 | Brendan | 11/26/2025 | 18364 | -replaced cash drawer cable pos15
-troubleshooted zoom timer, looking like it needs a new loop at the second window. Vehicle detector board telling me it’s shorted, I swapped a known good loop on to make sure it was working which it is. Checked all the service entrances and stuff to make sure everything looked okay. The box outside is a bit loose but everything seems in tact everywhere which leads me to believe a bad loop. YES is going to check it out next week |
| 3959 | Brendan | 11/26/2025 | 07417 | -hung drive thru window dings
-installed diamond plate back sink |
| 3958 | Adanel | 11/25/2025 | 16552 | -nothing, this machine is driving me cucu. Replace the scale on the machine and didnt fix anything also holly work to get a screw out😭. Now waiting on a single screw according to their support that might he a problem. |
| 3957 | Jim | 11/25/2025 | 21582 | -lobby door locking perfectly fine NTF
-replaced music amp |
| 3956 | Brendan | 11/24/2025 | 04205 | -replaced coffee brewer board and fill solenoid |
| 3955 | Waylon | 11/24/2025 | 18364 | -Fixed door weather stripping installed new grouted hole in floor by weather strip and need to get a bottom threshold strip still |
| 3954 | Brendan | 11/24/2025 | 18364 | -replaced and rekeyed detex
|
| 3953 | Waylon | 11/24/2025 | 10544 | -Nashua washing machine had to fix shut off valve in wall and hook up new machine |
| 3952 | Brendan | 11/24/2025 | 10544 | -replaced washer valve box whattttt a pain |
| 3951 | Brendan | 11/24/2025 | 04205 | -repaired broken line in multiplex
-water heater heater leak has two bad shutoffs so the whole store had to be shut off💀 |
| 3950 | Adanel | 11/23/2025 | 10622 | -came to replace the baby changing table in the womens bathroom and it seems fine so ntf after talking back and forth with the manager.
-filled the hole in the wall in crew room |
| 3949 | Adanel | 11/23/2025 | 04205 | -repaired bumpbar cable on delivery screen |
| 3948 | Adanel | 11/23/2025 | 02038 | -Troubleshooted the kiosk number 7 and it had no touch so was while fighting with it and the ped needed a rescue and mid/tid reset soooo yeah it took a little while |
| 3947 | Adanel | 11/22/2025 | 11565 | -replaced mens bathroom faucet
-troubleshooted their hand blow dryer and er have to replace the board and heating element. |
| 3946 | Adanel | 11/22/2025 | 18364 | -finish grouting the 4 tiles |
| 3945 | Adanel | 11/21/2025 | 36960 | -installed a new led light in the kitchen
-replaced ballast and sockets for the light above the shake machine
-this was a movie🤣 a whole process. I bought a wet saw to cut the tiles and that was so smooth and amazing loved the machine, kinda slow you know but itsss fineeeee, it did its job. So with mortar i placed 4 tiles that fell and tomorrow im going to grout them an dmake them look pretty or at least try🫡 |
| 3944 | Brendan | 11/21/2025 | 16552 | -ABS warranty call, needs replacement current sensor on order |
| 3943 | Brendan | 11/20/2025 | 07417 | -installed cup holder blanks
-installed lobby ceiling tiles and painted some
-removed dish sink racks
-removed door closer from office door and replaced screws so the door wouldn't sag |
| 3942 | Waylon | 11/21/2025 | 18364 | -Instaleld new oep
-Installed new co2 alarm and tested |
| 3941 | Adanel | 11/20/2025 | 18364 | -tried fixing thr wall tiles, I took out ONE and 3 more fell down then i went to buy a tool to cut the tiles straight and how i wanted the tool ended up not working😤
Waster time so tomorrow imma give it another try in the old fashion way.
-according to brendan we have to switch from led tube lights to led lights because one the metal braket is bad and it fell today and the second one was smoking heavily so instead of tryinf fixing it just replace it and everyone happy.
-fixed all the moving chairs, had to take them all off and redo the little hole where the screw went in or i had to make another hole for them
-did a solid 15 minutes trying to follow a card reader cable which got disconnected and there was kinda a mess behind the soda machine sooooo you know.
-the first window doesn't latch because it needs a new spring inside
|
| 3940 | Waylon | 11/20/2025 | 07417 | -Fixed dry wall destroyed taped and mudded (painter is doing another muddling layer and painting )
-Took down shelves above dish sink for prep before diamond plate installed
-Cut and installed multiple lobby ceiling tiles
- replaced OEP
-Diagnosed bad table heater
-filled holes in the wall by dish sink
-Fastend down coke tank |
| 3939 | Adanel | 11/20/2025 | 16552 | -troubleshooted and tried calibrating the frappe machine but holly molly, thats a complicated one😅 called support and we are going to try replacing the scale to see if it fixes the issue. |
| 3938 | Waylon | 11/19/2025 | 17371 | -Camra upgrades do 3/4 of inside cameras got more inside work to do and lines but got the basics up and running
-Poossihky finally fixed the cabinet line filter board jumped out and started working gonna keep an eye on it |
| 3937 | Brendan | 11/19/2025 | 17371 | -installed all network equipment rack and installed all indoor cameras🥹 |
| 3936 | Adanel | 11/18/2025 | 18364 | -configured and replaced all printer except kitchen ones. Moved the working ones to the kitchen and threw away the bad ones.
-checked the women bathroom baby stall and its closing normally
-checked the light and its the ballast that its bad
-ordered the entrance sign
-ordered the toaster oep cord
-backdoor its closing
-
|
| 3935 | Adanel | 11/18/2025 | 36960 | -installed the last 2 ped in FC so jackson its all fone for
-helped brendan with the expansion barrel and watched him do the solenoids and water valve aswell. |
| 3934 | Waylon | 11/18/2025 | 00596 | -Turned off ice machine to do motor when ice melts
-fixed part in Qing oven then store lost all the screws to it sooo can’t even put it back together had a bad capacitor shorting fuses
-Replaced back window card reader
|
| 3933 | Brendan | 11/18/2025 | 36960 | -inboxed fryer and set up, just needs RTI to come out now
-replaced co2 fill solenoid left FCB barrel what a painnnn. Replace right barrel expansion tank. Water valve on right barrel was sticking from syrup buildup so took that apart to clean. All is working now |
| 3932 | Waylon | 11/18/2025 | 07417 | -Fixed fry station broken wire and abd socket |
| 3931 | Waylon | 11/18/2025 | 36960 | -Unboxed new fryer |
| 3930 | Waylon | 11/17/2025 | 04956 | -Installed new motor for grill was awful and took forever
-Replaced bump bar do desert monitor crimp
-NTF on cabinet not working
-Replaced grill screen
-order 4:1 fridge new door |
| 3929 | Brendan | 11/17/2025 | 18364 | -store does NOT need new emergency light they have an emergency light backup system already, whoever said they needed one was incorrect
-back door detex key is of course like the only key i don’t have so I’ll have to order |
| 3928 | Brendan | 11/17/2025 | 11565 | -replaced grill 2 standby button
-replaced two vats speakers
-ordered faucet for men’s room because someone stole it😑
-troubleshooted men’s room hand dryer but have to order special security key to open it up |
| 3927 | Brendan | 11/14/2025 | 04205 | -truck driver broken Coke tank dispense hose, repaired |
| 3926 | Brendan | 11/14/2025 | 21582 | -Repaired grill exhaust hood. Cable damaged from switch to disconnect. Cord was too short to cut back so had to go to the store to get new cord. Replaced with longer cord so wouldn’t happen again all setttt |
| 3925 | Brendan | 11/13/2025 | 02038 | -ABS arm not moving. Welp turn out check valve in multiplex failed so soda water was backing up into the co2 lines flooding the multiplex. Rebuilt the check valves and dried out air lines best I could
-noticed co2 test port had a leak, capped off |
| 3924 | Brendan | 11/13/2025 | 16552 | -took pics for water upgrade/abs |
| 3923 | Brendan | 11/13/2025 | 21582 | -repaired lobby door not locking |
| 3922 | Brendan | 11/13/2025 | 10544 | -replaced ABS turret pin and screen splash guard |
| 3921 | Brendan | 11/13/2025 | 21582 | -replaced water tube filet steamer
-replaced FCB flavor decals
-replaced hand sink batteries
-troubleshooted lobby music, believe it needs a new amp on order |
| 3920 | Brendan | 11/12/2025 | 21582 | -replaced McFlurry blender switch
-tightened dish hose |
| 3919 | Brendan | 11/12/2025 | 16552 | -ran network cable for new ABS
-replaced leaking valve in basement |
| 3918 | Brendan | 11/12/2025 | 36960 | -replaced handicap door transmitter
-troubleshooted epr, having a windows boot error had to reimage
-troubleshooted light in walk in, it’s an LED one needs new driver/led but the model is obsolete so ordered new unit |
| 3917 | Brendan | 11/12/2025 | 18364 | -fry station down. Switch was bad. Had to go to store to get replacement. Replaced switch and all burnt wire terminals |
| 3916 | Brendan | 11/11/2025 | 10544 | -drove from alton to milford to nashua to bring backup co2 tank
-fixed dt window 2 out of alignment |
| 3915 | Brendan | 11/11/2025 | 17371 | -troubleshooted other UHC. Loose connections causing heat causing breaker to trip. All fixed
-more troubleshooting on the trouble cabinet. Found the distribution cable missing a wire at the very end near the connector. Must have come defective like that from the factory |
| 3914 | Brendan | 11/10/2025 | 36960 | -store lost a phase of power so they are closed tried to see what I could find, ended up calling electrician. Even he was a little confused but we determined it to be a power company issue. They should hopefully be out today but they will keep me updated. Feels like such an unproductive day |
| 3913 | Brendan | 11/10/2025 | 02038 | -new oven install |
| 3912 | Adanel | 11/09/2025 | 00596 | -troubleshooted the ice machine in the lobby and the problem is that the motor is dead
-troubleshooted the qing oven and keeps blowing the fuse so i need a capacitance meter which i dont have so brendan is going to take care of it. |
| 3911 | Adanel | 11/08/2025 | 16552 | -tries fixing the frappe machine. Called and support was closed today, so i re-installed the belt again.
-installed 2 door hanldes in the bathrooms
-turned off ac/heating unit due to heavy smell of gas |
| 3910 | Adanel | 11/08/2025 | 11565 | -replaced washer lid lock |
| 3909 | Brendan | 11/07/2025 | 25383 | -called for ABS not dispensing soda water. I was in ALTON so I had to drive 2 hours to get here 😭 replaced carb water spring
-repaired right sprite lobby valve |
| 3908 | Brendan | 11/07/2025 | 17371 | -replaced ped15 cord
-another unsuccessful attempt at uhc |
| 3907 | Brendan | 11/07/2025 | 10622 | -replaced ABS ice gate |
| 3906 | Adanel | 11/06/2025 | 21582 | -troubleshooted the filet toaster and theres a hole in the hose so need replacement
-replaced light ballast above hlz
-added weather strip to back door
-troubleshooted the mcflurry mixer and the switch is bad |
| 3905 | Brendan | 11/06/2025 | 36960 | -grabbed cam footage for officer
-troubleshooted left grill, bad transformer will order
-troubleshooted kitchen fryers and it turns out the right frypot is condemned soooo need to work on getting a new fryer. Probably for the best with all the mouse nesting materials in there 🐀 🤢 |
| 3904 | Brendan | 11/06/2025 | 12272 | -sprite not working, co2 was unplugged…
-tech rack/orb clean out |
| 3903 | Brendan | 11/05/2025 | 21582 | -installed new filter system. Unfortunately one of the plastic connector pieces is broken so will have to order that before placed in service |
| 3902 | Adanel | 11/04/2025 | 12272 | -replaced all PEDs and replaced light bulbs in the back |
| 3901 | Adanel | 11/04/2025 | 18364 | -replaced 2 kiosks PED |
| 3900 | Brendan | 11/04/2025 | 21582 | -repaired fry station, replaced two sockets
-replaced OJ machine door latch |
| 3899 | Brendan | 11/03/2025 | 07417 | -replaced fc runner monitor. also installed Lenovo kvs bracket and fixed all the awful cable management |
| 3898 | Brendan | 11/03/2025 | 00596 | -replaced cabinet switch
-removed prong from outlet
-replaced office monitor vga cable
-replaced ped13 paddle |
| 3897 | Brendan | 11/03/2025 | 07194 | -repaired fry station lights
-ABS ice NTF
-Espresso machine NTF
-reattached CIP adapter wires |
| 3896 | Adanel | 11/02/2025 | 12272 | -replaced gasket on dish sink |
| 3895 | Adanel | 11/02/2025 | 36960 | -replaced relieve valve(i think thats the name) on frozen drinks |
| 3894 | Brendan | 11/02/2025 | 16552 | -office construction🫠 |
| 3893 | Adanel | 11/02/2025 | 16552 | -office remodel |
| 3892 | Adanel | 11/02/2025 | 11565 | Not even gonna talk about it |
| 3891 | Brendan | 11/02/2025 | 11565 | -crimped new bump bar connector |
| 3890 | Adanel | 11/01/2025 | 18364 | -replaced 4 tiles kn lobby
-replaced light on the toys section in lobby
-troubleshooted bathroom flusher, the battery was attatched right
-replaced 1 light lense
-fixed a printer with another printer a frankestain
-the apple pie had a cover and the light was working behind it so just removed it.
|
| 3889 | Brendan | 10/31/2025 | 00596 | -lobby door having issues latching shut. Broken spring. Had rebuild kit on me all fixed.
-installed replacement sharps container in men’s room |
| 3888 | Waylon | 10/30/2025 | 17371 | -Jad to pickup dish sink sprayer in epping installed the sprayer had to make a custom sized support rod but leak checked taped and dipped everything ran water for couple minutes should be all set
-Wejt to work on cabinet found out the one main part I needed was back ordered and just shipped out today so cabinet is still waiting sadly |
| 3887 | Adanel | 10/30/2025 | 16552 | -replaced the blender motor from the frappe machine(got interrupted like 15 times, they lost the bathroom keys and they learned later how to pry them
-took measurements of the doors for new locks |
| 3886 | Brendan | 10/30/2025 | 04205 | -replaced back door mortise lock set with push bar
-adjusted temp of kitchen hand sink
-autoadjust hotg screen |
| 3885 | Waylon | 10/30/2025 | 02830 | -HLZ needs new transformer and replaced fuse no voltage coming off transformer for board deep cleaned the inside was a mess |
| 3884 | Waylon | 10/30/2025 | 00596 | Hlz Newfie an taped of main lines that were pushed together |
| 3883 | Waylon | 10/30/2025 | 04205 | Installed new grill motor with Brendan and 4 new belts we used old grill motor to save money
-Fixed hlz cord frayed
Small rgr things |
| 3882 | Waylon | 10/27/2025 | 04205 | -had to source tiles for bathrooms
-polished down one men bathrokm mirror frame made it look brand new from graffiti just for someone to ruin the other one the next day
Had to get a new Sander since my brand new one broke after like 1 use |
| 3881 | Waylon | 10/28/2025 | 04205 | Spent a long ass time here working on the bathroom tiles had to be broken out and replaced and they were lik 20 pounds per tile had to mount to the wall and secure without falling - nightmare awful
-Had to create a metal plate to cover the door stopper where a tile was crack
-Had to sand down where old tiles were to put new
-Had to sand down door from burn marks
-Tried polishing and grinding down mirror to get etching out
Random miscellaneous things |
| 3880 | Brendan | 10/30/2025 | 04205 | -replaced broken hose in multiplex causing leak
-replaced right grill left zone motor and belts
-replaced HLZ side 2 cord |
| 3879 | Brendan | 10/29/2025 | 11565 | -FC ABS not working, thru beam sensor was missing its screws and hanging off. Redrilled holes and fixed |
| 3878 | Brendan | 10/29/2025 | 16552 | -measured for clearance for new ABS. Amazingly, the landing zone is movable. So they will need to move the Qing oven table, landing zone, bottle fridge, and register cart out for them to get clearance |
| 3877 | Brendan | 10/29/2025 | 04205 | -right grill left zone giving home switch error. Found motor bad, really grinding and not making it to home switch in time. Will return tomorrow morning with replacement |
| 3876 | Brendan | 10/28/2025 | 02038 | -tech closet cleanup
-calibrated OJ fill levels |
| 3875 | Adanel | 10/28/2025 | 16552 | -replaced the fryer dispenser power cable
-tried troubleshooted the abs but bruh didnt think that there was a reason kn why it had to be replaced so watsed time there
-troubleshooted the frappe machine with brendan and concluded on the replacemnt of the motor and belt |
| 3874 | Waylon | 10/27/2025 | 25383 | FCB barrel 1 refrigeration issue I believe strongly hot gas solenoid is leaking forced solenoids open and closed and the barrel actually started working so gonna replace both valves which is a pretty extensive process gonna probably take a full day and then for fcb barrel 2 had to recalibrate Coke into it and test BRIX levels took a while to do that |
| 3873 | Brendan | 10/27/2025 | 10544 | -replaced ABS turret door and hinges
-ABS arm stuck down, came unscrewed from the arm all set |
| 3871 | Adanel | 10/26/2025 | 11565 | -replaced 1 printer and installed one |
| 3870 | Adanel | 10/26/2025 | 10544 | -the new handle didnt match the old oneee soooo i had to make a couple of holes but now it looks fine and work aswell🤣 |
| 3869 | Adanel | 10/26/2025 | 25383 | -watched the repair of the leak above the multiplex
-learning moments with brendan😁
|
| 3868 | Brendan | 10/26/2025 | 25383 | -repaired leaking line above multiplex
-teaching moments with adanel |
| 3867 | Brendan | 10/26/2025 | 12272 | NTF |
| 3866 | Adanel | 10/25/2025 | 25383 | -tried fixing a leak and made a mess, the little valve broke and u know ggs💀 |
| 3865 | Adanel | 10/25/2025 | 07417 | -grouted all sink and where u put the mapple and a little bit of the fryer area missing grill. Was too tired to continue, follow for part 2
-installed the bumpbar for bakery screen |
| 3864 | Brendan | 10/24/2025 | 16552 | -checked out ABS not that the ice has melted. Ice bin AND drain pan cracked. Probably a 15k job or so there
-measured office for desk |
| 3863 | Waylon | 10/24/2025 | 10622 | Fixed backdoor side weather stripping per ecosure visit
-Fixed bump bar cable
-Foxed light going through back door hole covered with sheet metal
|
| 3862 | Waylon | 10/24/2025 | 04956 | -Fixed lobby stool falling off
-Fixed hlz not working
|
| 3861 | Brendan | 10/24/2025 | 12272 | -replaced bad ABS thru beam sensor. It’s as good as it’s going to get without spending 2k on a new drain pan
-repaired drive thru window again, replaced missing leveling bolt thing and leveled doors
-store hooked up root beer to tea brewer, flushed and sanitized lines |
| 3860 | Adanel | 10/23/2025 | 07417 | -replaced 5 tiles
-replaced one light lense
-replaced the lights in the freezer
-replaced a baseboard for lobby
-cuttes and threw away ALOT of wood/pallet
-secures light pole cover(ate 4 bits doing it)
|
| 3859 | Brendan | 10/23/2025 | 21582 | -cut out side of office desk
-replaced dt present bump bar and added new section on cord becuase it was too short to cut back |
| 3858 | Waylon | 10/23/2025 | 07194 | -Had to custom make hinges for ice machine
-Install new dry socket |
| 3857 | Brendan | 10/23/2025 | 07194 | -melitta milk NTF
-Troubleshooted lot merge camera. Opened up connector and water poured out. Had to replace connector and camera, also waterproofed better |
| 3856 | Waylon | 10/23/2025 | 18198 | -Installed new washing machine
-Fixed both coffee brewers one needs the blue spray head might have to order
The other needs the temp probe cleaned and wires fixed then tested it brewerrs |
| 3855 | Brendan | 10/22/2025 | 07417 | -moved giant pallet shipment in parking lot
-replaced and calibrated root beet valve on right tower that was brutally yanked off
-replaced mens left urinal flush head that was also brutally yanked off (and stolen, thats $900 they stole!) |
| 3854 | Waylon | 10/22/2025 | 10544 | -Installed back door pus bar with Brendan an made a metal plate to cover holes in door |
| 3853 | Waylon | 10/22/2025 | 16552 | -Went over tech rack office remodel with Brendan
Worked on multiplex frappe machine for blender motor locked got it cleared |
| 3852 | Waylon | 10/22/2025 | 11565 | Resecured walk-in hinge |
| 3851 | Brendan | 10/22/2025 | 10544 | -front hand sink, just needed batteries…
-replaced left fryer front computer
-installed new push bar left stock door |
| 3850 | Brendan | 10/22/2025 | 16552 | -planned out tech rack stuff
-troubleshooted ABS ice. The entire agitator motor and bracket somehow broke off. Have to come back when the ice melts to look at the inside to see if it’s broken |
| 3849 | Brendan | 10/22/2025 | 25383 | -replaced three syrup valves on FCB. First barrel has a refrigeration issue |
| 3848 | Waylon | 10/22/2025 | 18364 | -Fry station diagnose bad switch installed new works and running |
| 3847 | Adanel | 10/21/2025 | 00596 | -unclugged men toiled💀
-put a piece of log back that had fallen
-coulnt find the exact piece of deck for the corral(put what i found) |
| 3846 | Adanel | 10/21/2025 | 36960 | -removed Esmart printer along with the braket and filled the holes |
| 3845 | Brendan | 10/21/2025 | 04205 | -calibrated Diet Coke, high on syrup. Tastes fine now and it is temping out and pressures are good
-removed old oven from cart
-replaced dish sprayer hose |
| 3844 | Waylon | 10/21/2025 | 17371 | Welp installed the part for the cabinet formatter told me was wrong with it didn’t do jack shit still having the same problem intermittent as fuck and I’m running out of time for today just frustrated cause I’ve tried everything I can think of and just spent multiple days fixing their muffin toaster which everything kept breaking in so gonna order new communication board for them
Measured stuff for the new refreshers coming and clearance heights
|
| 3843 | Waylon | 10/21/2025 | 10622 | -Oven heating error nobody on the store knew about it so did a once over it all found nothing major sticking out found an element not being used because the wrong outlet is being supplied which means only 2/3 of the oven is heating which is probably where they saw a problem from but more like a hiccup since the oven has been working fine besides that only fix I see if this becomes more of a problem is change the electrical
-Fixed back door looks like it was kicked in stripped multiple screws in brand new push bar and bent door frame fixed the push bar and monted it with like 6 screws way more hardware can’t fix the bent frame door closes fully on it’s own |
| 3842 | Waylon | 10/20/2025 | 00596 | -Cut out part of office desk for tech rack initiatives |
| 3841 | Waylon | 10/20/2025 | 02038 | -Grill had a broken belt shorted on the element causing the relays to also blow so needed new belt and relays installed did food safety after and sat with it for a couple mins to make sure relays didn’t go again |
| 3840 | Waylon | 10/14/2025 | 04205 | Worked with Brendan on this day replaced
OEP tried to fix the cap just to start really need to find some type of spring puller tool cause winding a spring with your finger is really hard replaced the full oep
Went to store and got electrical outlet covers and fuses for table heater and outlet box in play place |
| 3839 | Waylon | 10/17/2025 | 12272 | RGR prep small random things like light bulbs egg crates ballast exc |
| 3838 | Waylon | 10/20/2025 | 18198 | Washing machine bad board needs to be replaced basically a death sentence for these cause the board cost 3/4 of a new one |
| 3837 | Adanel | 10/19/2025 | 36960 | -replaced the esmart clock
-removed kids tablets and put outlet covers |
| 3836 | Adanel | 10/19/2025 | 04205 | -Bruuuuuh finalyyy i finishheedddd. I was so unprepared for this one i went out line 20 times. My mistake was not looking at everything first and then fix. I went one by one and in every single one i had to go to home depot.
-replaced the light ballas and bulbs
-replaced the power cord of the frappe machine.(took the longest i didnt even have the tips/connector/ plugs for the frappe side
-replaced the battery on the back door alarm.
I got coocked today...
-tried fixing the diet coke, it was working fine but the taste is weird, so did a calibration and it didnt work. Problem for another day... |
| 3835 | Adanel | 10/18/2025 | 18364 | -drove to pelham to replace the coke valve but somebody went ahead of me and did the work👀 |
| 3834 | Adanel | 10/18/2025 | 36960 | -Did the kiosks PED |
| 3833 | Adanel | 10/18/2025 | 18364 | -had to run the cable for the cloud box music and replaced it. |
| 3832 | Adanel | 10/18/2025 | 16552 | -took the pictures of the tech closet
-they were missing the printers brackets but after a while we found them😅 and put them back on
-replaced the music box
-measured the cbb layout
-troubleshooted the scanner and i think is gonneeee so we need to order a new one |
| 3831 | Brendan | 10/17/2025 | 36960 | -ABS down, replaced carb water spring, all set |
| 3830 | Adanel | 10/16/2025 | 02038 | -reattached the sill that broke off along with 4 tiles. Holly work, scrapping that glue wqs crazyyy imma wake up with one arm strognwe than the other🤣
-replaced cash drawer |
| 3829 | Brendan | 10/16/2025 | 10544 | - |
| 3828 | Adanel | 10/16/2025 | 21582 | -troubleshooted men urinal and fixed it
-replaced bumpbar cable |
| 3827 | Waylon | 10/16/2025 | 12272 | -Installed new fry socket
-installed new ballast
-spent a while on dt curbing 2/3 look pretty the other one literally needs a new curb beyond fixing
|
| 3826 | Brendan | 10/15/2025 | 04956 | -repaired multiplex that was flooding the stock room
-troubleshooted door dash tablet turning off. Whatever charging cord they had plugged into it was shorting causing it to turn off. Replaced the cord, hopefully nobody messes with the cords again
-replaced missing blue FCB decal
-installed unified DisplayPort, just needs a crimp since I ran out, will drop one in on my way by tomorrow |
| 3824 | Waylon | 10/15/2025 | 17371 | Fixed water leak at washing machine
Installed muffin toaster snubber board and programmed installed new side panels
Fixed back sink not staying attached to wall
Fuck these fry master cabinets absolute nightmare says RANDOMLY display board 1 bad swapped the displays to see if issue followed then was like only thing besides that is the master control board swapped those seems to fix it and then found out that it didn’t which is because a random display strip can randomly give the error as it’s going bad so there’s no way to actually find out which one it is I think I narrowed it down to side 1 so replaced those 3 which they are the most used strips also needs a new ribbion cable |
| 3825 | Brendan | 10/15/2025 | 04205 | -was going to do oven install but this is the only one in the company that is single phase. Can’t convert it becuase the breaker still too small. Will probably have electrician come out to switch to 3 phase |
| 3823 | Brendan | 10/15/2025 | 10622 | -replaced card reader cable
-replaced lobby door dogging mech |
| 3822 | Adanel | 10/15/2025 | 02830 | - replaced the automatic flusher for a manual |
| 3821 | Adanel | 10/14/2025 | 21582 | -the men urinal has a bad solenoid. Waiting for one.
-the bumpbar has a bad cable im gonna ask for one. Tried multiple times and double checked the work.
-and the pie meh its just old. |
| 3820 | Adanel | 10/14/2025 | 00596 | -the dish pipe was broken so i took it out solder a new one and its working perfectly.
-Replaced P trap but didnt read that it was clogged and when i saw it, it didnt have anywater sooo i replaced the p trap and made water run to make sure of no leaks andddddd it was clogggeeeeed do had to take everything apart and do it again😭 |
| 3819 | Brendan | 10/14/2025 | 04205 | -replaced fuses for prep line heater
-repaired backup co2 regulator. Someone set it all the way high and stripped the knob so was blowing out the relief valve. While doing that I noticed that co2 was in constant demand. Found the frappe switches swapped, so none of the bags were able to pump and the empty ones kept pumping becuase they didn’t have a bag. This is probably why they ran out of co2 in the first place
-noticed multiplex heavily leaking water. Found the low pressure switch sprung a leak. Didn’t have one on me, so just bypassed and cut it out since this store is going in the trash soon
-was going to replace wheels for 10:1 freezer but apparently I ordered the wrong wheels… my bad, I’ll try ordering again.
|
| 3817 | Brendan | 10/14/2025 | 07194 | -replaced TSP
-looked for leak at washer but it was actually the water heater spraying from the boiler, death sentence, Rick replacing tomorrow
-re-paired handicap buttons |
| 3818 | Adanel | 10/14/2025 | 11565 | -fixed the hand washer, i crimped all the cables and it was still not working so i openend the power box and it had a couple cables out of the connected including the connector
-tried fixing the second hand washer but its missing the whole power box |
| 3816 | Waylon | 10/14/2025 | 07417 | -installed new table 1 heater and wired in
-Measured cup holders that need cover plate
-Went over two things from list with Drew |
| 3815 | Brendan | 10/14/2025 | 07417 | -replaced side 1 table heater
-installed mop holder |
| 3814 | Waylon | 10/13/2025 | 25383 | -Checked out lobby shades having the company do it needs two motors and bearings
-Went to recalibrate FCb and not a single mixer valve was working for calibrations all stuck high
And NtF on table heater |
| 3813 | Brendan | 10/13/2025 | 25383 | -troubleshooted lobby shades. Now both weren’t working. Amended up calling the company and said it sounded like bad motors, which I would agree with. They will be out at some point to repair
-troubleshooted FCB. Barrel 1 not freezing hardly at all. Found brix set really heavy on the syrup. Attempted to adjust but would not budge. So valves are defective on order
-breakfast cabinet NTF
-prep line heaters all working NTF |
| 3812 | Brendan | 10/13/2025 | 12272 | -replaced cracked prefilter bowl and placed back in service
-replaced bad carb A motor and rewired correctly. It was wired incorrectly to begin with |
| 3811 | Waylon | 10/13/2025 | 12272 | -Regrouted whole McCafé frappe area |
| 3810 | Adanel | 10/13/2025 | 36960 | -troubleshooted printers but idk why all printer were disconnected from the kitchen and restarted the spooler💀💀 |
| 3809 | Adanel | 10/13/2025 | 18364 | -Replaced pos 15 printer |
| 3808 | Adanel | 10/11/2025 | 12272 | -replaced 7 light lences
-tried finding a light ballast but wasnt able to so just ordered one.
|
| 3807 | Brendan | 10/09/2025 | 04205 | -troubleshooted oven not working. Motor is dead. Unit is from 1985 can no longer get parts for. New unit on order |
| 3806 | Adanel | 10/09/2025 | 18364 | -replaced front counter PED(not kiosk, missing data cables)
- troubleshooted the tea brewer but NTF or need a better explanation of whats the problem. The sugar eas working fine. |
| 3805 | Adanel | 10/09/2025 | 36960 | -troubleshooted the refrigerator and it took forever but got it working it was the PSU that was bad
-rebooted the MB which was frozen
-all the frozen flavors where off. |
| 3804 | Waylon | 10/09/2025 | 16552 | -More work on the oven - installed ordered parts relay and contactor just needs a new power cord and should be all set power cord is cut and has a wire barely making connection I taped of to cover don’t have time today to drive to Home Depot adj get supplies and back so hopefully it makes it till someone can get here |
| 3803 | Waylon | 10/09/2025 | 11565 | -Installed new fry hopper spring and was still temping so didn’t dive into a leak check |
| 3802 | Waylon | 10/09/2025 | 10622 | - was looking at prep fridge gasket not covering so wasn’t keeping its temp threw my gauges in just to be more confident that was the only problem found no gas in it so filled with gas then went and did a leak check found copper pipe midway through evaporate had a hole In it sent photos to Brendan and they’re ordering new
Ordering new probe for freezer it’s reading -1800 degrees lol
|
| 3801 | Brendan | 10/08/2025 | 17371 | -muffin toaster element swap stupidddddd |
| 3800 | Brendan | 10/08/2025 | 04956 | -installed walk ins and freezer cams |
| 3799 | Waylon | 10/08/2025 | 04956 | -Installed walk in and freezer cams |
| 3795 | Adanel | 10/07/2025 | 00596 | -"fixed" the leak under the sink
-my phone died while trying to buy p trap for hand washer soooo next time ill do it |
| 3794 | Adanel | 10/07/2025 | 07194 | -replaced power adapter on pos |
| 3793 | Adanel | 10/07/2025 | 18364 | -tried unclugging the prep station and frappe drain but wanst successfull
-replaced batteries on women bathroom and it works |
| 3792 | Waylon | 10/07/2025 | 16552 | -Found both contactors in bad shape and door switch was stuck closed so that could’ve been what’s intermittently causing problems just spliced door switch together and ordered new contactors |
| 3791 | Brendan | 10/07/2025 | 12272 | -cleared frappe drain pan and clogged line. When I pulled out the unit I noticed worm larvae swimming in the water. Then I noticed the espresso machine leaking as well. Pulled both units out and brought back so the store can deep clean the area and machines before we come back and grout
-readjusted ABS thru beam sensor
-window 2 sensor was catching its door closing so kept reopening. readjusted electric eye all set.
-store already took out dry socket themselves
-McCafé machine was on no power issues NTF
-re aimed a useless camera so it would catch front counter
-got called at 4am for breakfast cabinet not working. waterline was not plugged in, operator error |
| 3790 | Waylon | 10/07/2025 | 11565 | Recharged unit had no gas set to around 12-15 psi I believe there’s a small leak but would need to nitro test and leak search to find out and found why right side of fry hopper wasn’t working has a broken spring which is now ordered |
| 3789 | Brendan | 10/06/2025 | 04956 | -ran wires for walk in, window 1 hall, dish sink, lot plate, and merchandiser. Installed two cameras
-fixed fry hopper right side door stuck open
-installed delivery tablets |
| 3788 | Waylon | 10/06/2025 | 00596 | -Grill 1 pneumatic system had a leak needed new 3 way valve fitting and new 90 fitting since the line snapped off inside of it tested air time and tested food safety
-HLZ from the looks of it jsut needed a very deep cleaning around the air heater and the blower motor had gunk all stuck up in it
-Back hand wash sink leaking needs a new p trap original concern was clogged which store got unclogged just needed me to tighten part of it still needs a new p trap |
| 3787 | Adanel | 10/05/2025 | 36960 | -fixed a switch loop |
| 3786 | Adanel | 10/04/2025 | 16552 | -replaced the controller on the oven |
| 3785 | Adanel | 10/04/2025 | 18364 | -replaced fanta BIB pump |
| 3784 | Adanel | 10/04/2025 | 02038 | - replaced 1st window dt camera monitor |
| 3783 | Adanel | 10/04/2025 | 02830 | -treied fixing the toilet but it does work the problem is thattttt it keeps brakinggg sooo we are going to replace with a manual one! |
| 3782 | Brendan | 10/03/2025 | 18364 | -installed 3 cup tubes at ABS and corrected cup mapping
-installed bulk coke drain hose
-fixed office printer not printing, IP address was incorrect |
| 3781 | Brendan | 10/02/2025 | 11565 | -installed walk in cameras, side 3 b camera, and outdoor speaker |
| 3780 | Adanel | 10/02/2025 | 18198 | -upgraded all front counter PED!
-picked up some stuff |
| 3779 | Adanel | 10/02/2025 | 07194 | -Troubleshooted register 15 and found out the block was bad, replaced it with number 14s power block and now its working until i get another one. |
| 3778 | Waylon | 10/02/2025 | 11565 | Installed new speaker - on the side of building took forever
-installed camera for walk in and freezer |
| 3777 | Brendan | 10/01/2025 | 18198 | -printer testing for corp
-installed 4 printers that were just sitting in the office even though the printers all work. Pos1, and three grill printers
-cleaned out boxes |
| 3776 | Brendan | 10/01/2025 | 00596 | -soda syrup leaking by ABS again… this time it was the coke line that had burst. Cut back line and replaced with new section. Got rained on by soda syrup again😭 |
| 3775 | Brendan | 10/01/2025 | 12272 | -called for card reader issues. The power cord was not plugged in all the way…
-replaced hinge cover for prep fridge
-replaced grill fridge controller
-repaired sprite valve on the right tower |
| 3774 | Waylon | 10/01/2025 | 12272 | -Removed old GFCI breaker to small McCafé fridge and replaced breaker had to source breaker in Manchester took 3 different locations but got it cheaper than ordering online
-Brendan and I installed new controller for 4:1 fridge |
| 3773 | Waylon | 10/01/2025 | 04956 | -Hlz smoking was due to I believe a bad connection from relay to blower motor since it intermittently shuts off the blower motor causing heat to be trapped in the bottom creating the smoke they saw but was super intermittent replaced those terminals Lowe’s didn’t have the exact copy so had to create something to work |
| 3772 | Waylon | 09/30/2025 | 17371 | -Fixed muffin toaster againnnnnnn wires burnt off in element those wires weren’t even a week old so Brendan and I are beginning to think the element is going bad if it’s heating the wires up to breaking point but this thing is becoming a money pit |
| 3771 | Waylon | 09/29/2025 | 04956 | -Fixed fry station light broken
-Hlz looks to need a new computer board but got it running and then 3 hours later they said it was smoking I think they dropped something in it tbh or it gave the error code which shuts of the blower motor making it look like it’s smoking
-Waited with the 10:1 freezer said it was getting no power turned on for me and got down to 0 before leaving |
| 3770 | Adanel | 09/30/2025 | 11565 | -replaced door latch on men bathroom |
| 3769 | Brendan | 09/30/2025 | 16552 | -repaired water line for espresso machine, coffee stick was leaking too so replaced that |
| 3768 | Adanel | 09/30/2025 | 16552 | -fixes a water leak behind the frozen machine
-new leak, it needs a coffee stick |
| 3767 | Brendan | 09/30/2025 | 18364 | -replaced scraper blades and installed dispense valve rebuild on blue raspberry FCB
-adjusted lobby door closer |
| 3766 | Brendan | 09/30/2025 | 00596 | -removed abandoned prechiller for ABS, replaced and repaired leaking section of Diet Coke line |
| 3765 | Adanel | 09/30/2025 | 18364 | -helped by watching how to fix the frozen blue flavor
-put a screw on the air vent in 1st window |
| 3764 | Brendan | 09/29/2025 | 10622 | -replaced frappe machine condenser fan motor
-after plugging in frappe machine it worked. but I noticed the drain line was clogged. Went to go clear it when I realized their drain lines are infested with fruit flies and larvae. I will be ordering new drain lines, should not sell from this machine in the meantime
-troubleshooted bunn coffee brewer. Found the heater wires on the relay melted and broke off, so the wire fell and were touching each other causing the heater to constantly run which caused the water to boil causing constant water dispensing lol. the relay also was burned up so replaced the burn pieces of wire, board, and calibrated
-installed uber and door dash tablets |
| 3763 | Adanel | 09/28/2025 | 25383 | -completely fixed the water leak in the back near the multiplex
-fixed the frappe machin leak which was the preasure water regulator |
| 3762 | Adanel | 09/27/2025 | 16552 | -replaced all card readerd in front counter
-helped them open the vault(im the strongest🤣) |
| 3761 | Adanel | 09/27/2025 | 11565 | -troubleshooted boozer on the men bathrooms door and the problem is the latch so its getting ordered! |
| 3760 | Brendan | 09/27/2025 | 02038 | -frappe machine been working perfectly past two days apparently. NTF
-merge monitor at first window bad, will order
-installed uber tablet and mounts and charger to delivery cart |
| 3759 | Brendan | 09/27/2025 | 36960 | -ABS conveyor stall, index sensor wire fell out, all set |
| 3758 | Adanel | 09/27/2025 | 00596 | -replaced second window PED |
| 3757 | Adanel | 09/27/2025 | 36960 | -the abs was saying conveyor stall and the problem was that the negative was disconevted from the connevtor of the index sensor |
| 3712 | Adanel | 09/16/2025 | 04205 | -Replaced 2 cabinet strips
-pushed in the qing oven cord
|
| 3756 | Brendan | 09/26/2025 | 07194 | -finally got frappe machine up and running. It took replacing the screen, SD card, and UVC4 upgrade kit |
| 3755 | Jim | 09/26/2025 | 18364 | - cleaned old caulking around hand sink and re caulked |
| 3754 | Jim | 09/25/2025 | 07417 | - rebuilt corner trim on shed |
| 3753 | Adanel | 09/25/2025 | 18364 | -tried fixing the frozen blue but the motor calibration didnt work so its a refrigeration problem.
-Its a normla amount of grease in the floar |
| 3752 | Adanel | 09/25/2025 | 25383 | -drove to epping to look for a part for the water line in mildford but i took the wrong size so coulnt fix it
-the frappe machine has the water regulator bad its leaking but didnt have it so couldn't fix.
|
| 3751 | Jim | 09/25/2025 | 12272 | - re mounted cabinet door in office
- replaced and grouted lobby vestibule (DT side) floor tile |
| 3750 | Jim | 09/25/2025 | 00596 | - replaced floor tile under lobby table and grouted |
| 3736 | Adanel | 09/21/2025 | 11565 | -forgot to take a picture the oep cable so brendan can Order it |
| 3735 | Adanel | 09/21/2025 | 04956 | -came to fix the hlz which said prob, just turned it off and on and its working fine. |
| 3733 | Adanel | 09/21/2025 | 18364 | -replaced blade and cleaned the ice vin in the machine also replaced what spins on it.
|
| 3734 | Adanel | 09/21/2025 | 16552 | -the leak is coming from the union of the sink and pipie is probably a gasket but i don have it rn. So we ordered it |
| 3749 | Waylon | 09/24/2025 | 17371 | -Muffin toaster replaced
All elements wiring
New contactor
2 new relays
Main board
-Cabient replaced distribution board |
| 3732 | Adanel | 09/20/2025 | 25383 | -replaced front counter and kiosk peds |
| 3748 | Jim | 09/24/2025 | 16552 | - replaced two kitchen sink drains and also rebuilt the piping from the copper drain to the grease trap, checked all connections and found no leaks |
| 3747 | Adanel | 09/23/2025 | 04205 | -tried to fix the hole in the water line on the sink but ended up replacing the whole water hose.
-couldnt find the leak on the women bathroom. |
| 3746 | Adanel | 09/23/2025 | 25383 | -found the leak or so i think, brendan has the valve/connector maybe on my next working day ill pick it up and fix it
-put the screws |
| 3745 | Waylon | 09/23/2025 | 16552 | -Replaced abs cup
-investigated leak by fish vats found eater advised store to not keep linen buckets next to it and turned of the autmotisters should solve their problems |
| 3744 | Waylon | 09/23/2025 | 18364 | Arrived and frappe machine was working store just needs to calibrate since it’s too icy |
| 3743 | Waylon | 09/23/2025 | 00596 | -Fixed hlz taped off common short points and replaced fuse
-Bottled beverage fridge no gas added and took the leak detector to it came up empty but didn’t do a complete leak check came down to temp multiple times |
| 3742 | Waylon | 09/23/2025 | 04205 | -Fix phone line and call Comcast to change modems |
| 3741 | Jim | 09/23/2025 | 02830 | - plunged, snaked and poured drain cleaner into ladies room handicap toilet, all clear . Also replaced batteries on auto flush unit |
| 3740 | Waylon | 09/22/2025 | 16552 | -Diagnosed bad HPCO was staying open so cut off wires and linked together until repair to get frappe machine running and refrigerating |
| 3739 | Waylon | 09/22/2025 | 11565 | -Prep fridge not cooling call found old system R12 very excellent endive refrigerant found no refrigerant in system which led to doing a leak test with nitro since it was R12 I can’t use a sniffer gas so no using any probes just bubbles and going by hearing found a leak in access port which is part of the compressor so basically options are new compressor, top of with gas and keep doing that but leak seems too significant or find a special cap to go over the port letting rick deal with this cause retrofitting r12 to a drop in refrigerant is a lot of work and time consuming |
| 3738 | Jim | 09/22/2025 | 10622 | - installed new exit sign out front |
| 3737 | Jim | 09/22/2025 | 07194 | - repaired men’s room toilet door lock
- repaired Detex unit, issue was unable to remove key with out tripping alarm |
| 3731 | Adanel | 09/20/2025 | 07194 | -fixed lobby back booth
-replaced door handle on men bathroom
-fixed blue screen on pos2
-fixed the door alarm |
| 3730 | Adanel | 09/20/2025 | 07194 | -fixed lobby back booth
-replaced door handle on men bathroom
-fixed blue screen on pos2
-fixed the door alarm |
| 3729 | Waylon | 09/19/2025 | 10622 | Frappe diagnosed bad condenser fan tripping the whole system
Installed new condenser fan motor for fried products freezer in grill |
| 3728 | Brendan | 09/19/2025 | 25383 | -put hose on multiplex back on, was very difficult because I had to take the retaining bracket off but the screws were rusted on
-cleaned out my packages out back |
| 3727 | Waylon | 09/19/2025 | 00596 | Refrigeration call NTF upfront fridge at temp when arrived |
| 3726 | Waylon | 09/19/2025 | 21582 | -Fixed fry station broken wires inside |
| 3725 | Waylon | 09/19/2025 | 07194 | -Arrived to NTF sounds like intermittent problems but fry station was working |
| 3724 | Jim | 09/19/2025 | 02038 | - changed pre filter on multi plex
- patched concrete hole with asphalt patch
- re fastened crew room wallpaper
- filled holes in walls in crew room
- mounted “ fryer, griddle signs
- fixed Detex unit |
| 3723 | Waylon | 09/19/2025 | 11565 | -fixed electrical issue in frustration
-Remounted freezer door for side 3 small freezer ordering new hing short term fix is in place atm |
| 3722 | Waylon | 09/18/2025 | 16552 | -Replaced start components to refrigeration then it was being intermittent and not starting to find out from the tech support after messing with it for a while the compressor runs on 5 minutes in and 13 off cycles so waisted a bunch of time for a piece of equipment that’s inefficient as fuck
-got serial numbers for grills |
| 3721 | Adanel | 09/18/2025 | 02038 | -cut out a tile for the crew room
-NTF on the kios not reading cards
-NTF on kiosk 6 keep saying its open, but it is open and taking orders🤔 |
| 3720 | Adanel | 09/18/2025 | 12272 | -replaced 6 ceiling tiles
-the door was making the noise because it had like a metal piece sliding in the floor
-reattached the solenoid and latch in the dt window |
| 3719 | Jim | 09/18/2025 | 10544 | - sourced and replaced sink drain and reconnected sink to wall |
| 3718 | Jim | 09/18/2025 | 07194 | - installed new fry socket and bulb
- checked sink issue and checked with in store maintenance (Donald) and he said he tightened it the other day |
| 3717 | Jim | 09/18/2025 | 02038 | - replaced ceiling tile
- no bulbs available for beverage fridge |
| 3716 | Waylon | 09/17/2025 | 10622 | -scrapped old grill
-Installed new dish sink full setup with sprayer
-Diagnosed freezer bad condenser fan and ordered |
| 3715 | Brendan | 09/17/2025 | 02830 | -replaced D50 and harness in espresso machine. Cleaned machine and verified it works |
| 3714 | Jim | 09/17/2025 | 17371 | - replaced exterior door handle
- tightened other exterior door handle
- replaced men’s room toilet flush control unit
- cut and replaced lite lens in stock room
- dropped two packs of kitchen ceiling tiles (16 total)
- checked freezer door closet found no issues |
| 3713 | Jim | 09/17/2025 | 00596 | - installed two screws on lobby table |
| 3711 | Adanel | 09/16/2025 | 04956 | -ped didnt have a connection. Just grabbed the ethernet cable and plugged it in in the other port.(it was my bad)
-the alarm kept settting off because of the tamper switch was slightly pointing downwards.
-NTF on the cabinets |
| 3710 | Brendan | 09/16/2025 | 02038 | -replaced McFlurry spinner button
-replaced FFLS print head
-ordered bulbs for beverage fridge
-replaced PED paddle with new version and mounted bracket |
| 3709 | Adanel | 09/16/2025 | 36960 | -unclugged sink! |
| 3708 | Waylon | 09/16/2025 | 18198 | -Caulked dish sink and removed old moldy caulk
-Put concrete anchors into track for stock shelves took forever to drill through
-Replaced muffin toaster cord
-Fixed light electrical component outside office
- reinstalled clearance bars with new hooks |
| 3707 | Brendan | 09/16/2025 | 00596 | -everything is bone dry under the ABS. NTF.
-removed light bulbs off the list, the store is capable of this themselves. They are normal light bulbs just like you have at home. They do not need technicians to come and screw a lightbulb in… |
| 3706 | Jim | 09/16/2025 | 21582 | - sourced and replaced two flush control valves, one in men’s room and one is women’s room small stall |
| 3705 | Brendan | 09/15/2025 | 17371 | -replaced scraper blades, installed dispense valve rebuild kit, brixed, and calibrated motor for blue FCB
-troubleshooted espresso machine grinder, got it working
-muffin toaster amp drawing normal, no errors, NTF
-UHC not showing errors or anything too intermittent to diagnose, NTF |
| 3704 | Brendan | 09/15/2025 | 10622 | -got back door latch unstuck. Ordering new rim push bar so we don’t keep having to come back for it |
| 3703 | Waylon | 09/15/2025 | 02830 | Grill 1 platen 2 had a broken spring
10:1 freezer gave me a little bit of a mess so originally ran perfectly fine but then would stop once it hit desired temp and never turn back on found start components on the compressor bad but since I could only fit a hand in there it took forever to wire up a 3n1 starter once I did seems to be running much more smoothly and hitting temps repeatedly |
| 3702 | Waylon | 09/15/2025 | 00596 | -Moved ice machine for east coast emptied 3/4 ice filled some boxes for freezer left off so store can move back on their own when it’s empty
-Helped remove a couple screws for fry vat pan |
| 3701 | Adanel | 09/14/2025 | 11565 | -fixed their the conveyor, reset and its fineeeer |
| 3700 | Adanel | 09/14/2025 | 21582 | -fixed leak on the mop sink and the sanitizer one
-tried fixing the bathroom i tried swapping parts but i broke both now🤣(i got the main one to work again) its definitely the solenoid that is bad🤔🤔🤔
-fixed the window which was getting stuck(replaced the motor. |
| 3699 | Adanel | 09/13/2025 | 10622 | -leak under the ice machine, the hose for the soda waste was out of the drain
-replace the shelfs on the maintenence closet
-replaced a light ballast |
| 3698 | Waylon | 09/12/2025 | 16552 | -Diagnosed creamer dispenser bad start capacitor for refrigeration system
-Need to call Taylor for grill gonna wait till Monday though |
| 3697 | Waylon | 09/12/2025 | 18364 | -Installed new frappe machine ice motor |
| 3696 | Waylon | 09/12/2025 | 07417 | -installed new frystation socket
Diagnosed bad heater for side 1 table |
| 3695 | Jim | 09/12/2025 | 21582 | - found the leak from the Kay mixing system is one of their proprietary fittings
Advised manager to call them to take care of the issue
|
| 3694 | Jim | 09/12/2025 | 04205 | - sourced and installed two new bulb protectors in walk-in |
| 3693 | Jim | 09/12/2025 | 02038 | - cut and removed scrap wood in corral
- filled pothole in parking lot
- replaced light pole cover in parking lot |
| 3692 | Brendan | 09/11/2025 | 18198 | -replaced delivery printer cord |
| 3691 | Brendan | 09/11/2025 | 04205 | -went to Grainger to pick up and replaced sundae side two belts |
| 3690 | Brendan | 09/11/2025 | 12272 | -troubleshooted ABS. Main issue was the sensor was just dirty. Also adjusted cup fingers so it would stop double pulling, and adjusted grabber sensor so it would detect when cups are out
-remounted paper towel dispenser |
| 3689 | Waylon | 09/10/2025 | 18364 | Bun toaster was a lot of work had to swap fan and motor and IO board and display board just to get it running that’s taking parts out of Londonderry s backup to get it running the toaster that Pelham had the mechanical part of the top assembly needs to all be replaced for it to be even thought about fixing the rest of it so will probably scrap for parts
Fixed club slide bent up not letting buns through that part |
| 3688 | Brendan | 09/10/2025 | 02038 | -“fixed” two printers
-the lobby door issue was actually stripped keys, so gave them new keys
-repaired co2 line leak to frappe machine |
| 3687 | Jim | 09/10/2025 | 04205 | - replaced ceiling tile in lobby
- built missing bracket and installed two new bulb sockets , need to order bulbs |
| 3686 | Waylon | 09/10/2025 | 17371 | -Qing oven had bad diode by fry hopper
-Went to diagnose blue raspberry needs to be recalibrated and needs a new lever rebuild kit
-Taking bun toaster off list seems to be doing well since lubed the chain holding on to parts for now |
| 3685 | Jim | 09/10/2025 | 02038 | - ground edge of corral pad to prevent tripping hazard
- filled two holes in parking lot |
| 3681 | Adanel | 09/09/2025 | 36960 | -replaced frappe machine screen
-fixed the water connector to the screen
-added a drain line to the frappen machine |
| 3684 | Brendan | 09/09/2025 | 18364 | -replaced rootbeer co2 armature tip
-picked up bad I forgot
-noticed right coke valve was cracked and leaking. Turned valve off and ordered replacement |
| 3683 | Adanel | 09/09/2025 | 00596 | -their menu boards where disconnected, thats why they werent working
- |
| 3682 | Adanel | 09/09/2025 | 11565 | -replaced o ring on the frappe machine
-remade the bumpbar connector |
| 3680 | Adanel | 09/09/2025 | 18364 | -replaced the armature tip on the rootbear front counter |
| 3679 | Jim | 09/09/2025 | 00596 | - cleaned water off floor and put one gallon of drain cleaner in floor drain, looks like it may have worked
|
| 3678 | Jim | 09/09/2025 | 02038 | - filled holes in tile by drive thru one and o j machine
- R&R 4 baseboard tiles by office and grouted
- cut and installed new light lens above ice bin |
| 3677 | Waylon | 09/09/2025 | 17371 | -Emergency call for hun toaster not working lubed up chain and ordered parts working for now |
| 3676 | Waylon | 09/09/2025 | 07417 | -Fry station blew through another switch…. Found neutral side of switch not open or closing just stuck close went to go source new switch from Lowe’s which it said they had in stock but the worker was dumber then a bag of rocks so hard wired switch in and the breaker is the switch atm Brendan is ordering a better one from grainger that hopefully will hold up better |
| 3675 | Brendan | 09/08/2025 | 07194 | -installed new label maker
-troubleshooted frappe machine. Swapped in a new touch screen and SD card to eliminate that but I think it’s a UVC board issue. Will order |
| 3674 | Jim | 09/08/2025 | 21582 | - checked ladies room toilet , stopped continual flushing and changed batteries on flush control. Will not flush at all now may need new solenoid
- still waiting for vacuum breaker for slop sink
- pM’ed ice machine |
| 3673 | Jim | 09/08/2025 | 07417 | - R&R right hand sink drain gasket replaced |
| 3672 | Jim | 09/08/2025 | 04956 | - cleared urinal drain clog
- snaked and plunged men’s room toilet |
| 3671 | Adanel | 09/07/2025 | 11565 | -came to fix printers, fixed one. Replaced another one that brought and coulnt find the one in the video and they are still missing a printer
-found a blue screen, just restarted it and its workig fine same goes with the e production |
| 3670 | Adanel | 09/07/2025 | 36960 | -Printer replacement complete |
| 3669 | Adanel | 09/06/2025 | 11565 | -replaced all front counter printers! |
| 3668 | Adanel | 09/06/2025 | 00596 | -replaced all front counter card readers |
| 3667 | Jim | 09/05/2025 | 10544 | - retighten top pipe nut and stopped leak on hand sink
- painted crew room wall that was damaged
- worked with Brendan to run water line |
| 3666 | Waylon | 09/05/2025 | 25383 | -Grill platen 4 new relay new hi limit and put protective sheaths over wires then tested temps on 4:1 and 10:1 |
| 3665 | Brendan | 09/05/2025 | 10544 | -ran all new waterline to frappe machine, a lottttt of work and veryyyy annoying
-replaced FFLS print head |
| 3664 | Adanel | 09/04/2025 | 04956 | -replaced all kiosk's card readers
-started the installation of the 2nd bakery screen. |
| 3663 | Brendan | 09/04/2025 | 18364 | -replaced line and fitting for frappe water
-fixed pos1 bsod |
| 3662 | Waylon | 09/04/2025 | 18198 | -new vestibule emergency light dt
-new baked monitor
-new fc present printer |
| 3661 | Waylon | 09/04/2025 | 07194 | -new dt present monitor |
| 3660 | Adanel | 09/04/2025 | 18364 | -replaced drain pan
-when i was putting the frappe machine back the water line to it exploded.(the connector) so its not connecting well, it pops out when put in.
-the shot off valve wasnt crimped soooooo you might know what happened next...🏝💧💧🌊🌊 |
| 3659 | Brendan | 09/04/2025 | 11565 | -replaced allll the bad ABS parts, working great now |
| 3658 | Jim | 09/04/2025 | 07417 | - ground down sidewalk tripping hazard at drive thru side
- applied two stickers over scratches on long table in the lobby |
| 3657 | Waylon | 09/04/2025 | 02038 | -welded fry station hinge
-Tightened abs cover
-NTF on creamer
-Updated label maker |
| 3656 | Jim | 09/04/2025 | 10622 | - re attached trim on play place table |
| 3655 | Jim | 09/03/2025 | 36960 | - replaced and grouted baseboard tile behind shake machine
-repaired wallpaper in lobby behind trash bin
- re fastened drain pipe cleaner line to pipe fitting
- tightened table top |
| 3654 | Waylon | 09/03/2025 | 12272 | -fixed broken off dish sink faucet
|
| 3653 | Brendan | 09/03/2025 | 12272 | -replaced broken diverter valve for dish sink and repaired other leaks
-troubleshooted wall freezer |
| 3652 | Brendan | 09/03/2025 | 04205 | -replaced DVR hard drive |
| 3651 | Waylon | 09/03/2025 | 07417 | -Installed new power switch for fry station |
| 3650 | Waylon | 09/02/2025 | 04956 | -Fixed power issue in cabinet
-Fixed power issue in filet still needs new computer board on order |
| 3649 | Waylon | 09/02/2025 | 12272 | -Fixed freezer door fell of tried multiple things before welding since welding into the rust only last about a year everytime tried jb weld and tried brazing rods neither worked so welded and tapped holes
Ordered new faucet they snapped the whole faucet off
|
| 3648 | Jim | 09/03/2025 | 02830 | - replaced landscape cover at drive thru two
- welded fry hopper rack in multiple spots
- installed two screws on 10:1 fridge top rack |
| 3647 | Adanel | 09/02/2025 | 02038 | -replaced 6 tiles which they stepted on😭😭😭 and then grouted them.
-installed men bathroom toilet paper
-filled 2 holes next to the office
-replaced the lamp plastic part in the dt.
|
| 3642 | Brendan | 09/02/2025 | 21582 | -repaired burst water line going to OJ machine. Replaced line to the wall because there was no slack at all |
| 3645 | Brendan | 09/02/2025 | 11565 | -troubleshooted ABS has manyyyy problems. bad lift arm gets real stiff when going from top to home position, many bad cup fingers, inconsistent ice gate, missing medium cup retaining ring, destroyed turret pin. parts on order.
-fixed PED1 and 9 connecting |
| 3646 | Brendan | 09/02/2025 | 04956 | -replace pos2 printer cable that was sliced and kept rebooting the register
-cleaned out all of my boxesssss |
| 3644 | Brendan | 09/02/2025 | 18364 | -Dropped off sundae side freezer door
-troubleshooted soda syrup issues. Tea brewer was pumping because it was empty and using all the air. filled it up and also drained the air compressor because it was veryyy wet
-refund investigation |
| 3643 | Jim | 09/02/2025 | 02038 | - replaced and grouted six floor tiles by frappe machine
- cut and installed new lite lens above present window
- installed new toilet paper dispenser in men’s room
- filled two holes in wall next to office |
| 3641 | Jim | 09/02/2025 | 00596 | - checked floor drain under ice bin, poured 1/2 gallon drain cleaner in to prevent clogs |
| 3640 | Waylon | 09/01/2025 | 25383 | Filet steamer replaced main board, water solenoid, regusltor, and water inlet tube then had to diagnose for why I was losing half my voltage found broken wire pinched in metal
- grill needs new relay new hi limit and sheath covers for wires shorting |
| 3639 | Waylon | 09/01/2025 | 36960 | -Diagnsoed frappe bad screen touch panel
-Delibery monitor was working on arrival |
| 3638 | Adanel | 08/29/2025 | 17371 | -replaced 4 pieces of siding(12ft each distributed in a couple of parts of the building) |
| 3637 | Jim | 08/29/2025 | 17371 | -Replaced four pieces of siding on building |
| 3636 | Jim | 08/29/2025 | 00596 | - replaced two boards and refastened three others on corral |
| 3635 | Adanel | 08/29/2025 | 00596 | -replaced 2 boards and tightened 3 others |
| 3634 | Adanel | 08/28/2025 | 36960 | -installed 3 new printers |
| 3633 | Waylon | 08/28/2025 | 02038 | Ice machine had to adjust the ice thickness probe again I was rushed out of here the other day and I had it set a tiny bit too low causing the ice to melt before dropping in the harvest cycle so waited with this one to make sure it dropped thickness is about 2/16 and a half and the right side evaporator takes longer to drop in harvest I believe the evaporator is on its way out with all scale and plating being ruined but it’s still making ice for now |
| 3632 | Adanel | 08/28/2025 | 36960 | -replaced ice motor on front counter soda machine
|
| 3631 | Jim | 08/28/2025 | 04956 | -PM’ed and steam cleaned ice machine with Adanel.
- run wire and connect from chase by 10:1 fridge and sub panel in crew room |
| 3630 | Adanel | 08/28/2025 | 18364 | -The frappe machine needs the drip pan replaced
-the leak on the abs was NTF. |
| 3629 | Waylon | 08/28/2025 | 07194 | -Installed outside license plate camera |
| 3628 | Brendan | 08/28/2025 | 07194 | -installed license plate camera and neatened up wires in office. 100% complete |
| 3627 | Adanel | 08/28/2025 | 25383 | -replaced first window card reader |
| 3626 | Adanel | 08/28/2025 | 04956 | -Learner how to clean the ice machine |
| 3625 | Waylon | 08/28/2025 | 07417 | -Installed fry socket |
| 3624 | Brendan | 08/27/2025 | 25383 | -STRUGGLED with lobby shades (LP bottom left breaker)
-rebuild backflow by back sink
-replaced broken strawberry syrup connector
-troubleshooted filet steamer. Had no power. Fuse blown but can’t get it out, need to order new fuse holder |
| 3623 | Waylon | 08/27/2025 | 07194 | Lobby ice machine NTF
Changed batteries in thermostats |
| 3622 | Waylon | 08/27/2025 | 10622 | Grill 2 left platen home switch not seen meaning the whole platen has moved up to far away from the switch basically a death sentence for the platen |
| 3621 | Brendan | 08/27/2025 | 21582 | -troubleshooted zoom timer connection issue, all set
-repaired lobby come valve |
| 3620 | Jim | 08/27/2025 | 00596 | - rebuilt exterior door frame both sides
- removed blue covers from restroom lights
- added door sweep on fridge door
- added three mop clips at slop sink |
| 3619 | Adanel | 08/27/2025 | 00596 | -took out the blue light filter in both bathrooms
-cut and welded back a piece of metal where all the rust was in the outside dooor of the freezer.
-bought mop hanger and replaced the olld ones.
Cleaned the van for the rest. |
| 3618 | Waylon | 08/27/2025 | 17371 | Qing oven not heating found blown diode
Replaced diode
Replaced intermittent switch
Replaced front display top (wouldn’t let me access service menu) |
| 3617 | Brendan | 08/26/2025 | 07417 | -replaced muffin toaster motor. Whoever designed this machine needs to be fired because working on these is impossibleeeee |
| 3616 | Brendan | 08/26/2025 | 07194 | -installed walk-in cameras
-replaced cash booth camera monitor that went bad
-replaced TSP that had the bad VDB |
| 3615 | Brendan | 08/26/2025 | 21582 | -installed replacement water booster |
| 3614 | Jim | 08/26/2025 | 04205 | - ran drain cleaner down lobby drink station drains , all clear |
| 3613 | Waylon | 08/26/2025 | 21582 | Helped install water pump |
| 3612 | Jim | 08/26/2025 | 07417 | - installed two screws to tighten door so it will lock correctly
|
| 3611 | Adanel | 08/26/2025 | 07417 | - Womens bathroom door was hanging basically and could not close. But now its all fixed |
| 3610 | Waylon | 08/26/2025 | 02038 | Adjusted and cleaned ice machine probe and had to run multiple cycles to get the thickness proper
Had to break open tech closet door because xfinity couldn’t get in due to being locked and store not having a key |
| 3609 | Jim | 08/26/2025 | 04956 | - poured cleaner into men’s room urinal and plunged all clear |
| 3608 | Adanel | 08/26/2025 | 04956 | -plunged and added the acid to the urinal |
| 3607 | Jim | 08/26/2025 | 18364 | - checked all floor drains, poured cleaner down all
No clogs |
| 3606 | Adanel | 08/26/2025 | 18364 | -Checked all drains and added cleaner just in case
-coffe machine, the water was disconnected so now its working |
| 3605 | Jim | 08/26/2025 | 12272 | - removed hand sink , cleaned wall and bracket, re installed sink
- re caulked kitchen sink |
| 3604 | Adanel | 08/26/2025 | 12272 | -fixed the hand washer that was falling off, now is strong in there
-I did culking in the disk sink |
| 3603 | Adanel | 08/25/2025 | 36960 | -trued to replace ice motor in the front soda machine but the model was wrong so waiting on the right one to install. |
| 3602 | Waylon | 08/25/2025 | 04205 | -rerouted ice machine drain through the wall into dishwasher drain |
| 3601 | Brendan | 08/25/2025 | 00596 | -replaced and tapped new screw holes for ABS sensor |
| 3600 | Adanel | 08/25/2025 | 10544 | -Fixed dish sink sprayer
-fixed frappe machine water line leak
-fixed the kink on the frappe machine it should be able to drain |
| 3599 | Waylon | 08/25/2025 | 21582 | —Installed new relay for filet steamer since old was hanging in to dear life and found the no heat error problem was a broken wire deep inside machine that split from the hi limit cause no heating to be allowed to go through fixed that and did a layer of tape over the line since with heat those lines typically start breaking down
-Installed new qing oven door switch |
| 3598 | Brendan | 08/22/2025 | 18198 | -replaced burst section of waterline behind the ABS ice machine. It is IMPOSSIBLE to work behind there, there 0000 room without totally moving the ice machine. this is why we don’t work on ABS ice machines! |
| 3597 | Waylon | 08/22/2025 | 02830 | Installed grill electrode
Installed new regulator and on off switch for filet still need to spend more time on it to get to the route of the issues was just trying to get it to safety turn on
|
| 3596 | Brendan | 08/22/2025 | 04956 | -picked up spare and replace broken pump part for shake machine |
| 3595 | Jim | 08/22/2025 | 10622 | - cleared toilet clog in ladies room |
| 3594 | Adanel | 08/22/2025 | 11565 | -finally the moffat is workingggg. Replaced the last water sensorrrrrr🫡 |
| 3593 | Waylon | 08/22/2025 | 07194 | -Came back for the grill went under removed panel and insulation found all wires intact just in case I replaced the hi limit and swapped control board received a call this morning that POSSIBLY the control board I swapped yesterday needs to stay swapped for a couple days and might fix the issue cause issue is still occurring and there’s nothing left to check so all this leads back to the root issue of the grill is older then me and grills are supposed to last longer then 15 years SO LIKE COME ONNNNNNN |
| 3592 | Jim | 08/22/2025 | 18364 | - cleared clog under prep sink |
| 3591 | Waylon | 08/21/2025 | 07194 | -I don’t even know what to say with this grill FROM 1998 LIKE ARE WE SERIOUS intermittent issue of heats up fine once up to heat when they repeatedly cook on it and then temp drops the back heater doesn’t work
Everything I tried:
swapped computer board swapped interface board swapped thermocouple board swapped computer board cable to interface board swapped rubbish cable from computer board to thermocouple board swapped the relay
None of this fixed it then asked multiple Taylor technicians the only thing they could come up left I haven’t done is wires broke around the hi limit so I said I’ll check it tmrw |
| 3590 | Jim | 08/22/2025 | 00596 | - sourced and installed new flush control valve for ladies room small toilet |
| 3589 | Adanel | 08/22/2025 | 18364 | -unclugged a drain where the hand washer is |
| 3588 | Adanel | 08/22/2025 | 00596 | -replaced the whole flush system in the little stall in the women bathroom. |
| 3587 | Brendan | 08/21/2025 | 21582 | -troubleshooted water issues again. bad booster system, on order |
| 3586 | Adanel | 08/21/2025 | 21582 | -We gotta replace the motor and pump! |
| 3585 | Adanel | 08/21/2025 | 00596 | -tried fixing the bathroom not flushing but i think is the main sensor that is bad.
-replaced the power suply on the expresso machine and is now working fine |
| 3584 | Brendan | 08/21/2025 | 00596 | -replaced power supply espresso machine
-troubleshooted ladies stall flsuher |
| 3583 | Adanel | 08/21/2025 | 00596 | -replace water tube that was damaged because of the worms.
|
| 3582 | Brendan | 08/21/2025 | 10544 | -replaced coffee stick and reconnected juice machine |
| 3581 | Jim | 08/21/2025 | 04205 | -picked up and installed, repaired mirror, in men’s room |
| 3580 | Adanel | 08/21/2025 | 11565 | -the moffet controller we thought was bad but it was the eater probe that came deffective from factory(it was grounded) so we ordered one to replace. |
| 3579 | Brendan | 08/21/2025 | 11565 | -went to replace what though was a bad controller at the breakfast cabinet. but that didnt work and was having reaaaaly weird issues. I found that one of the new probes was already defective. on order... |
| 3578 | Jim | 08/21/2025 | 10544 | - steam cleaned frappe machine
- re aligned and glues roof drain pipe
- adjusted strike plate on lobby emergency door, closes and latches ow |
| 3570 | Jim | 08/20/2025 | 10622 | - cleared clog in ladies room toilet
- welded hinge on front counter door
- PM ed ice machine |
| 3577 | Adanel | 08/21/2025 | 16552 | -fixed a loose cable on the E-production screens |
| 3576 | Brendan | 08/21/2025 | 16552 | -eprod cord loose all set |
| 3575 | Adanel | 08/20/2025 | 11565 | -tried changing the probe on the egg heater machine but I believe its a bad controller, it kept shooting errors after errors. |
| 3574 | Adanel | 08/20/2025 | 16552 | -sprite wasnt coming out, unplug and plug the conector all done
-re-imaged e productions monitors. |
| 3573 | Waylon | 08/20/2025 | 02830 | -Install new condenser fan motor for the fry hopper and then 30 mins later they said it was broken again was not a refrigeration issue found the bottom part was weighing down the scale too much thinking there were fries in it all the time |
| 3572 | Brendan | 08/20/2025 | 17371 | -wasted two hours coming to an NTF call about the FCB…. |
| 3571 | Adanel | 08/20/2025 | 17371 | -NTF |
| 3568 | Waylon | 08/20/2025 | 10622 | -Fixed beverage fridge near fc
-Installed new thermostat for prep fridge and removed old system
|
| 3567 | Brendan | 08/20/2025 | 04956 | -repaired water leak at breakfast cabinet
-employee door NTF, did notice screw loose preventing it from closing all the way until you pulled it so I tightened that
-tables all working on arrival NTF |
| 3566 | Adanel | 08/20/2025 | 04956 | -Fixed a water leak
-NTF for all the other things |
| 3565 | Brendan | 08/19/2025 | 16552 | -repaired water line behind coffee brewer |
| 3558 | Adanel | 08/19/2025 | 16552 | -fixed leak behind the coffe machine
-troubleshooted E-production screens and needs USB in order to work.
-fixed printer(it was disconnected) |
| 3564 | Waylon | 08/19/2025 | 21582 | -Grill electrode Taylor sent me the wrong package
-Need new switch for qing oven
-Filet steamer needs new switch and regulator can’t diagnose further till then
|
| 3562 | Jim | 08/19/2025 | 04956 | - sourced and installed new mailbox post
- re mounted men’s room soap dispenser |
| 3561 | Waylon | 08/19/2025 | 10544 | -Replaced power distribution board on cabinet
-Kinda repaired the pipe for rain water it’s drip leaking needs a new section installed just don’t think I can do it alone with how big the pipe is |
| 3560 | Waylon | 08/19/2025 | 10544 | -Replaced power distribution board on cabinet
-Kinda repaired the pipe for rain water it’s drip leaking needs a new section installed just don’t think I can do it alone with how big the pipe is |
| 3559 | Jim | 08/19/2025 | 11565 | - cleared men’s urinal drain |
| 3557 | Jim | 08/19/2025 | 21582 | - sourced and installed ew washing machine
- ordered vacuum breaker for mop sink faucet |
| 3556 | Waylon | 08/19/2025 | 02830 | -Fry hopper not freezing found condenser fan motor not working and receiving power meaning the unit is going off on high head pressure everytime it try’s to run left unit off and ordered part checked capacitors too while I was there both within range |
| 3555 | Waylon | 08/18/2025 | 10622 | -Reset co2 alarm code
-Kitchen prep fridge charge is good and it seems to be temping find grabbed an apple juice box at 38 degrees does need a new digital thermometer old one is reading it’s negative temp and needs new gaskets
-Fridge for fc holds bottle water had no charge in I don’t believe or it had a couple ounces found the whole evaporator covered in a super thick ice block so no air was getting through left door open needs to melt can’t use a torch on it because theirs wires covered in the ice
Bottled dt fridge not templing really didn’t find anything tooncocnerneing add maybe 4 ounces of refrigerant but it was at almost 36 degrees when I left |
| 3554 | Waylon | 08/18/2025 | 10622 | -Installed new coffee brewer water inlet valve
-Reset co2 alarm code
-Went fro grills having problems same grill was having a problem as before and Taylor has the part on ordee |
| 3553 | Brendan | 08/18/2025 | 07194 | -troubleshooted zoom timer. Present loop detector not working. Need to replace TSP. on order
-troubleshooted merge camera. Apparently just needed to be rebooted |
| 3552 | Jim | 08/18/2025 | 02038 | - cleaned three lobby ceiling tiles and replaced three
- filling Hole in dumpster pad
- patched drive thru one transition
- tp dispenser on order from manager |
| 3551 | Adanel | 08/18/2025 | 02038 | -went a bought tiles so we can replace them. Replaced 3 tiles and cleaned 5.
-the men toilet paper dispenser is ordered
-clean and filled some holes outside in the drive trhu and in the corral. |
| 3550 | Brendan | 08/18/2025 | 02830 | -creamer not dispensing, armature came unscrewed all set |
| 3549 | Jim | 08/18/2025 | 02830 | - installed 2screws in top shelf of 10:1 freezer
- cut fallen tree |
| 3548 | Adanel | 08/15/2025 | 21582 | -pump came out of the motor in the water pressure in thr booster pump.
-Troubleshooted the washing machine and replaced the lid switch but i belive is a bad motor |
| 3506 | Adanel | 08/08/2025 | 07194 | -completed cameras |
| 3536 | Brendan | 08/15/2025 | 21582 | -troubleshooted water pressure issue. Booster pump came loose from motor. all fixed
-replaced lid switch for washing machine but realized after that it had a bad drum motor. Jim to replace on Monday |
| 3547 | Adanel | 08/12/2025 | 11565 | -installing cameras |
| 3546 | Adanel | 08/16/2025 | 00596 | -troubleshooted expresso machine and we believe that the power suply is bad
|
| 3545 | Brendan | 08/16/2025 | 00596 | -repaired printer
-troubleshooted melitta. Bad power supply on order
-had to call Comcast to fix phone |
| 3544 | Adanel | 08/16/2025 | 02038 | -replaced pan in the abs
-replaced printer
-fixed the lock on the office door |
| 3543 | Adanel | 08/16/2025 | 04205 | -replaced fused in the microwave/oven
-fixed water leak behind the tea brewer |
| 3542 | Brendan | 08/16/2025 | 04205 | -repaired tea brewer water lines
-replaced biscuit oven fuse |
| 3541 | Brendan | 08/16/2025 | 02038 | -replace ABS drain pan and sensors. works great now!
-fixed a few printers
-reversed office door handle |
| 3540 | Jim | 08/15/2025 | 02038 | - upon arrival I found the store had no ice , after checking the ice maker I saw it had a descale light flashing so I ran it through a clean cycle and it reset
- sourced and replaced office door and window as while changing the window out it fell and shattered. Replaced with plexiglass |
| 3539 | Jim | 08/15/2025 | 02830 | - worked on cutting up tree until the door store opened
|
| 3538 | Adanel | 08/15/2025 | 10622 | -Fixed water leak on the water pressure in the back
-Tried fixing the sensor "lost sensor" but we dont have any parts. |
| 3537 | Brendan | 08/15/2025 | 10622 | -replaced burst water line to IMF filter |
| 3535 | Adanel | 08/15/2025 | 16552 | -fixed a leak on the water pressure valve in the basement.
-fixed a leak behind the brewer machine and replaced the main connector.
-troubleshooted the co2 sensor and i think it needs to be replaced.
|
| 3534 | Brendan | 08/15/2025 | 16552 | -replaced burst section of line at booster and replaced broken flare washer
-replaced section of bad line and connections at left coffee maker |
| 3533 | Adanel | 08/14/2025 | 36960 | -installed pandors cloud box for music |
| 3532 | Adanel | 08/14/2025 | 11565 | -installed cameras today |
| 3531 | Jim | 08/14/2025 | 02830 | - worked on cutting downed tree from neighbor’s property , which took out our chain link fence. This is a property that I believe the owner at the time was advised of the dangerous nature of the tree.
|
| 3530 | Jim | 08/14/2025 | 02038 | - grouted floor area by fry station and vats
- installed and grouted base tile in center lobby bench
- replaced six ceiling tiles in kitchen area
- re fastened kiosk top face plates
- priced and ordered door for office |
| 3529 | Waylon | 08/12/2025 | 11565 | Camera upgrade got covered in rat shit all in my hair |
| 3528 | Waylon | 08/13/2025 | 10544 | Well I was in a rush and broke something installed 6 new cabinet strips and then shorted the cabinet so needs a new power board when I was putting the side panel back on
Fixed grill loose thermocouple
Fixed bump bar cables
Ordered parts for McCafé water line
Outsourcing grill fryer to Casco looks like bad transformer it’s just buried deep behind all the gas stuff
Fry fryer board wasn’t working unplugged and cleaned started working
|
| 3527 | Waylon | 08/13/2025 | 18198 | New side 1 monitor installed |
| 3526 | Adanel | 08/13/2025 | 21582 | - fixed and grouted 3 broken tiles |
| 3525 | Jim | 08/13/2025 | 21582 | - replaced theee baseboard tiles and grouted |
| 3524 | Waylon | 08/13/2025 | 17371 | Cut down fence by enter side of store
Installed new printer
Looked into qing oven problem they thought it was the outlet outlet was fine I inspected inside of qing oven and checked amperage nothing looked bad and it heated up fine |
| 3523 | Jim | 08/13/2025 | 00596 | - re mounted bar stool seat |
| 3522 | Adanel | 08/13/2025 | 00596 | -fixed the bar seat on the lobby |
| 3521 | Brendan | 08/12/2025 | 11565 | -camera upgrades |
| 3520 | Jim | 08/12/2025 | 21582 | - tightened eco sure fitting above slop sink ( had a leak)
- repaired two hand sink drains
- replaced base tile by side one hand sink
- sourced and replaced spray hose and spring
- Installed hose clamp on sink soap dispenser
|
| 3519 | Brendan | 08/12/2025 | 18364 | -replaced optional flavor peristaltic pump |
| 3518 | Jim | 08/12/2025 | 10544 | - installed check valve in slop sink soap dispenser line
- installed flex seal tape under middle and right hand sink joint |
| 3517 | Brendan | 08/11/2025 | 02830 | -troubleshooted optional shake flavor not working. Managed to get it up, sanitized, calibrated, and tuned up.
-replaced UHC power board
-fry hopper NTF
-AC unit was off on the roof |
| 3516 | Brendan | 08/11/2025 | 02038 | -tea brewer, co2 was off to sugar…
-hot water was off yet again to front hand wash sink… |
| 3515 | Brendan | 08/11/2025 | 12272 | -troubleshooted ABS. Conveyor veryyyy broken. New on order |
| 3514 | Brendan | 08/11/2025 | 16552 | -replaced co2 sniffer
-troubleshooted coffee brewer. Bad fill valve leaking |
| 3513 | Brendan | 08/11/2025 | 11565 | -replaced breakfast cabinet water temp probe
-installed co2 alarm power cord
-adjusted muffin toaster color |
| 3510 | Adanel | 08/11/2025 | 16552 | -grouted under the sink, kitchen and 2nd windown again this time i put some cardboard there so that can hold as much water as it can.
-put the screws on the poles.
-put in 4 ceiling tiles and dropped of 2 box of ceiling tiles for them.
-card read in pos 1 was off and loose.
-replaced print head, roller and blade on printer pos 13 and still it was shooting blank in one side. I just bent the metal that helps it close the lid and its working🤣 |
| 3512 | Waylon | 08/11/2025 | 10544 | Installed new co2 sniffer in basement other one was corroded from water leakage |
| 3511 | Jim | 08/11/2025 | 16552 | - replaced left hand sink drain
- repaired beacon street side door frame
- grouted by drive thru two and in front of fry vats
- removed signs from fry hopper door
- unclogged hand sink drain |
| 3509 | Waylon | 08/11/2025 | 11565 | -Fixed co2 alarms needing power and tested
-adjusted muffin toaster color
-moffit probe installed |
| 3508 | Brendan | 08/11/2025 | 04956 | -adjusted bathroom light sensor timers
-fixed kvs3 printer
-grill hand sink store already fixed |
| 3507 | Waylon | 08/11/2025 | 04956 | -Adjusted dimmer switch bathroom
-hand wash sink store replaced batteries working |
| 3505 | Brendan | 08/08/2025 | 07194 | -finishing up camera upgrades. all cameras are complete except for 1 lobby, 2 walkins, and 1 license plate cam. We ran out of cameras so ordered more.
-replaced side 2 monitor and office spot monitor |
| 3504 | Waylon | 08/08/2025 | 07194 | -installed monitor for side 2 breakfast
-installed camera monitor
More camera upgrades |
| 3503 | Adanel | 08/07/2025 | 07194 | -fixed cpi panel not turning on and the problem was that the fuse was dirty and it had a wired unplugged from the connector.
-did cameras part 1
|
| 3502 | Jim | 08/08/2025 | 10544 | - sourced and replaced battery in ladies room toilet
- sourced and replaced spray hose at sink
- re installed letter “P” in lobby
- sourced check valve for slip sink will install Monday |
| 3501 | Waylon | 08/08/2025 | 07194 | -Was put back on the list the drain I spent a while on was overflowing again… it was not. Got there and found the back flow preventer which has been bad for years so it always dribbles water down it all the time was not in the drain causing the floor to get wet the store wasn’t smart enough to look at the drain and see that either way I replaced the back flow that was bad since I noted it when fixing the drain and we ordered replaced backflow no longer leaking instructed store to dry out the area and put co2 tanks back to where they belong what’s everything is dry watched drain do its job perfectly fine the whole time I was there |
| 3500 | Jim | 08/08/2025 | 07194 | - repaired delivery door frame
- installed new door sweep on delivery door
|
| 3499 | Brendan | 08/07/2025 | 07194 | -repaired ABS thru beam sensor that fell off
-troubleshooted CIP panel not turning on. found wire pulled from terminal at the plug and a loose fuse holder
-replaced two bump bars
-camera upgrades |
| 3498 | Waylon | 08/07/2025 | 07194 | Camera upgrade part 1 half the store is almost done |
| 3497 | Brendan | 08/06/2025 | 07417 | -called for leak above multiplex. found water line on booster leaking. replaced hose. Also noticed that the pre filter was turned off and bypassed. When turning on the pre filter it was leaking from the built-in shutoff. New pre filter on order |
| 3496 | Brendan | 08/06/2025 | 02830 | -left lobby soda station troubleshooted. Found the transformer tripped so it would not dispense drinks. Narrowed down the culprit to a loose wire on one of the valves. Put the wire back on an reset the transformer all are now working
-troubleshooted fry hopper left side. Motor got stuck. Unstuck it and is now working normally
-troubleshooted IHC with slot temp error. Bad power board on order
-lemonade NTF
-creamer NTF was not freezing and was temping appropriately |
| 3495 | Brendan | 08/06/2025 | 11565 | -cameras got delivered to some random guys house in Lawrence even though the address was correct on the label. Had to go all the way there to pick them up and bring to the store |
| 3494 | Waylon | 08/06/2025 | 04205 | -cleared drain out back to the right of multiplex was clogged and filled with tons of rocks and pieces of tile after a lot of vacuuming finally broke my snake through and got the rest out and drain clean reset drain cap that was snapped of with concrete and filled around the cap with concrete set up snail fan to keep drying it for next 24 hours but it’s draining and hopefully sealed will last a year
-Cleared abs drain a straw was clogging it and a bunch of white crap |
| 3493 | Adanel | 08/06/2025 | 16552 | -replaced 9 tiles
-grouted the whole sink area
-grouted in front of the kitchen
-did some hw |
| 3492 | Jim | 08/06/2025 | 04205 | - isssue was wax seals , upon inspection found no leaks and all toilets tight, caulked all three toilets at floor |
| 3491 | Brendan | 08/06/2025 | 10544 | -handicap door NTF
-filet steamer NTF
-replaced POS CLD
-noticed pos2 printer was jammed and could not open. Had to open up the cutter mech to clean out to repair
-scoped out what I need for mop sink backflow |
| 3490 | Brendan | 08/06/2025 | 16552 | -troubleshooted co2 alarm. First of all it was in GERMAN, not even spanish lol. Changed it back to English/spanish and it told me sensor two was offline, and it was in fact dead. new sensor on order
-beverage printer was unplugged
-fixed ORB not working |
| 3489 | Brendan | 08/06/2025 | 11565 | -troubleshooted air issues. Line in multiplex has a hole causing there to be no pressure. Repaired the leak all set |
| 3488 | Waylon | 08/05/2025 | 00596 | Fixed middle cabinet UHC bottom row not working
-Looked in prep fridge for “ice block got nothing and they were using it so took off the lsit |
| 3487 | Waylon | 08/05/2025 | 02038 | - back in the same grill from yesterday found out something was shorting it ended up being the hi limit hitting bare metal replaced hi limit and relay which blew cause of it now it’s shorting on the opposite side after the hi limit which means it’s not blowing any parts so that’s good but there’s just literally no insulation left to seperste the metals from grounding to each other so leaving this for Taylor to fix not sure if they have to pull the whole motor and replace the insulation piece or if they have some type of alternative insulation fix |
| 3486 | Waylon | 08/05/2025 | 18198 | -Fixed camera dt monitor ans dt 2 monitor not working |
| 3485 | Jim | 08/05/2025 | 07417 | - cut and installed lite lens
- cut and installed two white wall tiles with grout behind the slush machine |
| 3484 | Brendan | 08/04/2025 | 18364 | -troubleshooted coffee brewers
-rescued ped6
-rebuilt blue raspberry valve |
| 3483 | Waylon | 08/04/2025 | 16552 | -Checked in with a couple follow up fixes
-Lobby seat ripped took up most of my time first time doing one and that was a mess but came out pretty well with only a couple battle scars from staples |
| 3482 | Adanel | 08/04/2025 | 16552 | -replaced the mirror in the men bathroom. |
| 3481 | Jim | 08/04/2025 | 07417 | - repaired two holes in wall by 10:1 freezer and slush machine
- installed 11 white wall tiles and five baseboard tiles and grouted |
| 3480 | Jim | 08/04/2025 | 00596 | - sourced and replaced flush control on large toilet in ladies room |
| 3479 | Adanel | 08/04/2025 | 07417 | -Cutout and installed 2 base tiles and grouted and replaced 4 lights bulbs in the freezer.
-Helped jim with filling the hole in the wall behin the slushie machine
|
| 3478 | Brendan | 08/04/2025 | 12272 | -repaired ABS thru beam sensor that snapped off |
| 3477 | Waylon | 08/04/2025 | 02038 | -Took a little longer cause store interrupted me for changeover 💀 but anyways needed two new relays for top platen installed tested VaC on coil and waited for it to come to temp then had them do food safety on 10:1 and 4:1 |
| 3476 | Adanel | 08/04/2025 | 36960 | -troubleshooted why blue sloshie wasnt miving nor dispessing and it said that it was out stock even thought the cage was full- the automatic change over valve was closed.
-the kitchen screens didnt have audio, the cable was disconnected. |
| 3475 | Waylon | 08/03/2025 | 04956 | This one took a little bit to get had to snake mop sink and dish sink drains and then once I cleared the block it was a very slow drain so had to snake again and then run 3 cycles of drain cleaner made sure mop sink could drain dishwasher could run and drain and washing machine could hold water and drain without backing up |
| 3474 | Waylon | 08/03/2025 | 18198 | Emergency drain service abs cleared and dumped 5 gal bucket down |
| 3473 | Brendan | 08/01/2025 | 00596 | fail |
| 3472 | Adanel | 08/01/2025 | 02038 | -replaced water pump on the multiplex that was leaking.
-tried replacing the abs drip pan, but the tube inside was kinked. |
| 3471 | Brendan | 08/01/2025 | 02038 | -repalced circ pump B that was leaking
-reaplced ABS drain pan, motors and sensors but the drain pan came defective with a kinked conduit. After two hours of trying to run the wire through the kinked hole decided to just call it and order a new one that hopefully does not arrive kinked |
| 3470 | Jim | 07/31/2025 | 17371 | - replaced exterior door handle
- adjusted door & closer and tightened top door hinge
- tightened dish sink faucet pipes
- replaced lite lens
- tightened nmens room door handle
-installed screw in exterior door crash bar cover |
| 3469 | Jim | 07/31/2025 | 04956 | - replaced left hand fry bulb socket
|
| 3468 | Brendan | 07/30/2025 | 11565 | -troubleshooted muffin toaster again, it refuses to come up to temp even though it seems to be burning muffins. ordering relays and new probes
-fixed EPR1 screens swapped issue
-fixed EPR2 on black admin screen
-fixed KVS5 on black admin screen
-was notified the camera system was beeping. Bad hard drive. We are fast tacking their camera upgrades to ASAP anyway since this system cannot be accessed remotely. Surveryed the store for equipment:
Indoor
5 basement
1 above stairs
1 back door/sink
1 side 3
1 office/walk in hallway
1 upstairs walk in
1 side 1
1 side 2
1 first window
1 office
1 HLZ/SAM
1 window 2
1 FC pos
6 lobby (like for like, locations are fine)
23 dome
6 outside
3 monitors
4hdd
Wall rack
Shelf
4 viewports
NVR
3AP
GATEWAY
SWITCH
HORN
PTZ |
| 3467 | Brendan | 07/30/2025 | 02038 | -wanted to take a second look at multiplex. Found a small leak in circ pump. Will fix that tomorrow to help improve the situation but still getting multiplex replaced due to the leaking caused by the water bin and insulation.
-fixed delivery monitor. Power and video were unplugged.
-hand sink hot water was turned completely off |
| 3466 | Jim | 07/30/2025 | 18364 | - installed new lite in lobby
- drain to left of stock room door cleared upon arrival
-tightened spray line to stop leak
- drain under multiplex, broke auger tried air pressure and plunging could not clear drain |
| 3465 | Adanel | 07/30/2025 | 18364 | - replaced lobby light
-tried unclugging the drain. Tried with the 25ft snake, it broke when trying to do it, tried with air gun, tried with a metal pipe. We did get a big ass brush out of it but still was clogged. |
| 3464 | Jim | 07/30/2025 | 16552 | - checked for leak in basement under ABS seems to be coming from a line in the bundle but can not see anywhere activity leaking
- dish sink leak is from the drain need new drain which will also fix the stopper issue
- insulation new baseboard tile and grouted
- mirror store doesn’t open till 8 AM , I will pick up mirror for next trip
- replaced batteries in back hand sink all good now
- checked stockroom drain leak , all dry |
| 3463 | Adanel | 07/30/2025 | 16552 | -checked the leak from basement(it seems to be from the hoses behind the ABS
-dish sink leak is coming from the seals connecting the tube under it(needs new drain)
-Replaced tile and grouted
-mirror will need to be picked up and replaced later.
-hand washer needed batteries
-the leaking behind the front beberage machine is due to the floor being open, like where the hoses go down theres no sealing or anything so when the floor get wet the eater start dripping thru the hole following the hoses and drain down. |
| 3462 | Brendan | 07/29/2025 | 07417 | -fixed broken thru beam sensor at ABS |
| 3461 | Jim | 07/29/2025 | 10622 | -Cut and installed new lite lense in kitchen
- repaired floor tile in play place
- cleared both urinals drains
- replaced sink nozzle
- installed new ballast in lite above trash door |
| 3460 | Jim | 07/29/2025 | 00596 | - tried to clear floor drain clog , could not reach the clog
- troubleshooted large toilet in ladies room , needs new flush valve
|
| 3459 | Brendan | 07/29/2025 | 18198 | -checked out stock shelf track, definitely not something thats a big deal we need to replace it for, nothing a few screws cant fix
-measured and took pictures of the walk-in freezer floor to set a refab requoted |
| 3458 | Brendan | 07/29/2025 | 00596 | -troubleshooted water coming from present window. ABS clogged drain pan. unclogged should be all set |
| 3457 | Adanel | 07/29/2025 | 00596 | Tried clearing the clogs on the drain and no luck.
Checked the ladies room flusher and it was the controle module. |
| 3456 | Adanel | 07/28/2025 | 02038 | Replace diet coke Armature
Added screws in the mccafe |
| 3455 | Brendan | 07/28/2025 | 02038 | -replaced ABS Diet Coke armature
-installed screws for McCafé screen door hinges |
| 3454 | Brendan | 07/28/2025 | 04205 | -removed stuck key from walk in door |
| 3386 | Adanel | 07/15/2025 | 36960 | -Fixed 4 printers |
| 3387 | Adanel | 07/15/2025 | 11565 | Fixed 3 printers |
| 3453 | Waylon | 07/28/2025 | 00596 | -Diagnosed hlz that’s wasn’t working due to sparking wasn’t the one that has a long term history of breaking jsut needed new power cord terminals and fuses tested and heated to desired temp
-table I guess not working was a bad led in the switch the switch itself still works they just said it was broken because it doesn’t light up not repairing turned on and made sure it heat up |
| 3452 | Waylon | 07/25/2025 | 07417 | Recharged freezer with a frozen evaporator suspecting a leak |
| 3451 | Adanel | 07/25/2025 | 11565 | -replaced and installed new toucless faucet |
| 3450 | Waylon | 07/25/2025 | 11565 | -Installed and sourced new men’s room sink new lines into it installed new power box for motion sensor someone ripped old out
-opposite men’s room sink wasn’t working at all upon arrival found twisted water line from solenoid fixed that and bad mixer valve replaced that and swapped water lines |
| 3449 | Waylon | 07/24/2025 | 18364 | -Fixed filet steamer new display board found a bad regulator not ordering leaving it fine it’s working it’s steaming not gonna spend more money if I don’t have too
-checked on multiplex to make sure she’s a happy girl she’s sitting between 33-36 perfect she’s happy |
| 3448 | Jim | 07/24/2025 | 02038 | - removed and replaced 21 floor tiles by front registers
- cut and installed black ceiling vent cover |
| 3447 | Waylon | 07/24/2025 | 04956 | -installed new time clock
-installed new qing oven touch panel |
| 3446 | Brendan | 07/23/2025 | 12272 | -mccafee fridge reset breaker and didn’t trip again NTF
-put chain back on dt2 window again
-replaced dt runner bump bar
-adjust walk in fridge door closer bracket
-ordered more soda nozzles |
| 3445 | Jim | 07/23/2025 | 16552 | - refastened rear cover on fridge unit by present area |
| 3444 | Waylon | 07/21/2025 | 18198 | - was really annoyed at the time so that’s why these are coming in late finished installing their compressor and charged the unit and it pulled a bacon meaning there was a clog somewhere was so beyond done running into problems with it so just had Rick take care of it they diagnosed a bad TXV valve which was what I thought was originally wrong with the unit but Rick’s guy told me compressor so was very annoyed but even professionals make mistakes sometimes so what can you do (lowkey should’ve trusted my gut diagnosis) but anyways |
| 3443 | Brendan | 07/23/2025 | 18364 | -replaced BAS sprite armature |
| 3442 | Brendan | 07/23/2025 | 11565 | -replaced music player
-tried to hunt down issue with no co2 alarms getting power. Traced out all the wires and found that a power cord is not even present! Will order
-water in basement by conveyor coming from foundation. Will have to call out contractors… |
| 3441 | Brendan | 07/23/2025 | 04956 | -time clock dead. Went to office to get a spare but I used up my two spares last week. Have a new one being rush shipped. Setup iPad to use for now |
| 3440 | Brendan | 07/23/2025 | 07417 | -investigating water issues with Ryan. Found a small leak behind dishwasher and fixed that. Will see if the water continues |
| 3439 | Adanel | 07/23/2025 | 11565 | Troubleshooted water leakage but its like behind the wall.
C02 sensors need a power cable
Replaced Siriusxm with pandora |
| 3438 | Jim | 07/23/2025 | 07194 | - sourced new screws and drilled& tapped new holes, re installed door closer |
| 3437 | Adanel | 07/23/2025 | 07417 | -replaced washer valves and selas that were leaking. |
| 3436 | Jim | 07/23/2025 | 07417 | - picked up and installed number three sign for drive thru spot |
| 3435 | Jim | 07/22/2025 | 02830 | - removed bench, straightened two “L” brackets, re installed bench a fastened in place |
| 3434 | Waylon | 07/22/2025 | 16552 | -filet steamer has INSANE amounts of tape inside it like fucking everything is taped which it isn’t even electrical tape it’s scotch tape I didn’t know that’s how we fix things should’ve picked up a thing or two from the last technicians dimbasses was shorted from a piece of tape anyways fixed that hi limit was tripped we are gonna get new hi limit new start relay
-Water faucet out back didn’t even mean to diagnose it was just trying to wash my hands 😭 needs new water mixer valve and new solenoid for faucet constantly running
-Oven found the old light switch receiving 120v swinging around inside it hoping that’s the last we hear about it electrocuting people cause everytime it’s something different from it being so old
-Took men’s room bathroom mirror in van
-ordered new hinges for abs soda to be welded on |
| 3429 | Adanel | 07/22/2025 | 10544 | Finished the fence |
| 3432 | Jim | 07/22/2025 | 10544 | - completed fence replacement in Nashua |
| 3431 | Adanel | 07/22/2025 | 02830 | Fixed the bad booth!!! |
| 3430 | Waylon | 07/22/2025 | 04956 | -Ordered wing oven touch panel bottom I had the top one so got confused coming in tmrw morning
-kitchen ice machine hinge replaced and gasket
-Beef drawer not closing properly took everything out redrilled holes put rivet nuts in and replaced all screws tested like 20 times |
| 3428 | Jim | 07/21/2025 | 10544 | - worked on fence with Adanel |
| 3427 | Brendan | 07/21/2025 | 07417 | -the hunt for water in grill continues. Opened up two walls, looked around in the ceiling, scoped more walls. Still nothing. Meeting Ryan on Wednesday to scope a few more drains. If we can’t find anything then we will have to have contractors come in |
| 3426 | Waylon | 07/21/2025 | 07417 | -Tried finding water leak in the wall / floor narrowed down to the corner of the grill but can’t find exactly where having east coast take a look
-Freezer not hitting temp literally just needed the thermostat adjusted |
| 3425 | Brendan | 07/18/2025 | 10622 | -replaced register that died from water damage |
| 3423 | Brendan | 07/19/2025 | 07417 | -Scoped the walls behind grill for signs of water leak. Still nothing found. I have no clue where it could be coming from..... |
| 3424 | Brendan | 07/19/2025 | 02038 | -ABS issues. This time it’s because thru beam sensor was loose. Beyond repair need to order new sensor and drain pan |
| 3422 | Waylon | 07/18/2025 | 07417 | Back up fry freezer was diagnosed a day or two ago by me bad defrost timer installed new and watched it drop from 78 degrees to 50 ltoldnstore to use if it goes below 10 and to notify Brendan what temp it gets down too
|
| 3421 | Waylon | 07/18/2025 | 18364 | On part like 6 of this multiplex causing problems got it vacuumed around 300 microns nearly perfect put a charge in it around 11 pounds 10 ounces and guessed the other 6 ounces since I had no pressure to force the refrigerant in on the scale, then walk away to start on the filet steamer come back at little later went from 95 to 58 but then back up to 64 was like what happened found the agitator stopped spinning then started up again then stopped pulled agitator out adgjusted the pipe so water was flowing through it then started going down again as I’m leaving it’s at 40.8 degrees should continue to go down just can’t baby sit it
Filet steamer replaced water solenoid which was what’s leaking but water solenoid went over main board and display board from leaking replaced main board since I carried one in van but don’t have a display so will order and replaced the water inlet to filet cause those always snap off when working on it from being crusty
-Leak tested multiplex with leak detector twice on bottom water bay came up with nothing and went on roof for Mac unit also came up with nothing should be all clear of any leaks of refrigerant |
| 3420 | Adanel | 07/18/2025 | 10622 | Replaced reguster 15 due to water damage |
| 3419 | Jim | 07/18/2025 | 10622 | - welded four bolts for new exit sign |
| 3418 | Jim | 07/18/2025 | 04956 | - re set two end posts in concrete on drive thru diversion rail
- checked fry lights left lite loose no issues |
| 3417 | Brendan | 07/18/2025 | 07194 | -replaced platen 2 left motor
-repaired leaking lobby rooter valve |
| 3416 | Adanel | 07/18/2025 | 07194 | -fixed rootbear leak, it had a bad seal.
-replaced grill motor
|
| 3415 | Adanel | 07/18/2025 | 25383 | -replaced the lock on the washer machine
-troubleshooted the shades and thry need a new switch
|
| 3414 | Brendan | 07/18/2025 | 25383 | -replaced washer lid lock
-troubleshooted blinds. Needs new switch on order
-replaced two kiosk help buttons |
| 3413 | Waylon | 07/18/2025 | 21582 | -Came back for side 2 freezer since it was an ice block yesterday added maybe 1.5 oz into system found 7-10 degree subcool which is idea it’s gone from 70 degrees to 11 so just told store to watch it and let me know if it gets not cold enough or excessively cold |
| 3412 | Adanel | 07/18/2025 | 00596 | -fixed hi c not dispensing, had a bad switch
-replaced the lock on the washer machine |
| 3411 | Brendan | 07/18/2025 | 00596 | -replaced washer lid lock
-repaired Hi-c valve in lobby. Bad microswitch |
| 3410 | Brendan | 07/17/2025 | 10622 | -relocated office printer to desk so it would stop getting killed by the water. Ran two internet lines for music and printer |
| 3409 | Waylon | 07/17/2025 | 12272 | -found multiplex with no charged at 95 degrees which originally we knew it was leaking but assumed it had been for a long long time and it was a small tiny leak but since after 2 weeks it’s got no charge began leak testing and after a bit of searching found a break in the line brazed it back together and then went to go use my vacumm to take the nitrogen out of the system and my vacation started to spit oil everywhere and still tried to get it to work put my micron gauge on yeah it was making the system have more air in it instead of taking it out need to come back after getting new vacumm pump and new tank of R404 |
| 3408 | Brendan | 07/17/2025 | 02038 | -ABS superseal kit came loose causing conveyor not to spin. Took off motor and tightened. Also replaced ABS conveyor because of a broken plastic piece
-mounted doorbell with screw |
| 3407 | Waylon | 07/17/2025 | 21582 | -Freezer took out charge weighed only had 5 ounces needs 12.5 to operate so put in 12.5 found high head pressure investigated more evaporator expansion valve was ice block so it’s sitting with the cover off dethawing |
| 3406 | Jim | 07/17/2025 | 25383 | - riveted exterior freezer door inner panel
- replaced exterior door lock for freezer |
| 3405 | Waylon | 07/16/2025 | 04205 | -Grill apparently not heating up(was perfectly fine and hitting temps)
-Grill platen 4 not going down all the way pulled grill out took of side panels adjusted regulator tested put back together food tested all good |
| 3404 | Waylon | 07/16/2025 | 00596 | -Weld fryer oil box pipe that was broken off
-helped build the new vacuum….
-Diagnosed washing machine bad lid latch
-Reboot outdoor menu boards
|
| 3403 | Waylon | 07/17/2025 | 18198 | -Installed new grill light had to mount junction box and splice electrical |
| 3402 | Jim | 07/17/2025 | 04205 | - men’s room toilet leak was repaired by in store maintenance |
| 3401 | Jim | 07/17/2025 | 02830 | - tightened hot water handle on kitchen sink
- frayed cord no longer in building |
| 3400 | Brendan | 07/16/2025 | 17371 | -repaired co2 leak on tank
-FCB NTF |
| 3399 | Adanel | 07/16/2025 | 17371 | -ntf on the slushie machine
-co2 leak fixed just had to tighten boly |
| 3398 | Brendan | 07/16/2025 | 10622 | -replaced music amplifier
-replaced women's stall solenoid and sensor head |
| 3397 | Adanel | 07/16/2025 | 10622 | -replaced audio amplifier
-troubleshooted and replaced solenoid in the womens bathroom it was continously flushing |
| 3396 | Jim | 07/16/2025 | 21582 | - grouted the two floor tiles
- cut and installed ceiling tile above multiplex |
| 3395 | Jim | 07/16/2025 | 07417 | - went to check on water leak issue
Checked floor drain clean out.
Also snaked kitchen sink drain with power auger found no clogs
Brendan said he would have someone come by |
| 3394 | Jim | 07/16/2025 | 21582 | - cut and replaced two broken floor tiles and grouted
|
| 3393 | Adanel | 07/16/2025 | 02038 | -abs machine needs a part for the conveyor that is broken.
-came to see a "broken register" but the major problem was that ut was off. |
| 3392 | Brendan | 07/16/2025 | 02038 | -went to replace register since it seemed bad as I was talking with the manager over the phone but all I had to do was literally press the power button.
-ABS trouble is that the plastic on the conveyor broke causing it to be askew and get stuck on the sensor. Will bring a new conveyor tomorrow when the office is open |
| 3391 | Waylon | 07/16/2025 | 07417 | -Freezer diagnosed bad defrost timer on order |
| 3390 | Jim | 07/16/2025 | 12272 | - reset and grouted baseboard tile at drive thru two
- replaced eco sure soap line for slop sink
- sourced and replaced hand sink drain
- installed new weatherstripping on delivery door |
| 3389 | Adanel | 07/15/2025 | 18364 | Fixed 4 printers |
| 3388 | Adanel | 07/15/2025 | 16552 | Fixed 2 printers |
| 3385 | Brendan | 07/15/2025 | 16552 | -water line blew off of DT carbonator. Replaced multiple lines that were broken or at risk of breaking
-noticed water booster was leaking in multiple places. replaced pump check valve and fittings. Also had to replace pressure relief that was leaking. Basement should be leak free over there now
-unsuccessfully tried upgraded firmware on receipt printers FC for the QR codes. will just replace with some extra Epson's I have laying around |
| 3384 | Brendan | 07/15/2025 | 04205 | -replaced basically the entire grill air system with Waylon what a pain
-replaced cbb bump bar |
| 3383 | Jim | 07/15/2025 | 11565 | - removed damaged edging on long table and one small one, cleaned and sanded
- repaired ceiling tiles and grade by office and grills
- tightened men’s room faucets
- filled pothole in front of corral
- patched cracks next to door frame by staircase |
| 3382 | Waylon | 07/15/2025 | 04205 | -Grill with Brendan installed new air compressor, new pressure switch, new cross Tee, new 3 way T, new airlines, and new regulator tested and worked closed in 3 seconds on both of them had in line reducers in but they came clogged so just left out and adjusted refukatorb |
| 3381 | Jim | 07/15/2025 | 02830 | - removed men’s room toilet and replaced wax seal and bolts |
| 3380 | Brendan | 07/11/2025 | 11565 | -replaced muffin toaster element with Waylon, wowwwww what a can of worms that project is, basically had to disassemble everything and put back together except its worse because you can't disassemble it because all of the screws are rusted tight or they are in a reaallllly inconvenient place |
| 3379 | Brendan | 07/14/2025 | 18198 | -troubshooted 3 menu boards not turning on. Just had to turn breaker off and on
-replaced permeate tank for filter
-troubleshooted emergency light in lobby vestibule. Somehow it was wired wrong. Corrected the wiring, but need to wait for the battery to charge to see if it will work. It could have killed the batter or lamps with how it was wired |
| 3378 | Adanel | 07/14/2025 | 18198 | -replaced filter tank
|
| 3377 | Jim | 07/14/2025 | 11565 | -removed damaged delivery door frame one foot up from the bottom.
Welded in new piece of frame, bonded and painted. Also installed new weatherstripping no light shining in anymore |
| 3376 | Adanel | 07/14/2025 | 21582 | -replaced light bulb socket from the fryer station |
| 3375 | Brendan | 07/14/2025 | 21582 | -fry station down, found burned crimp. replaced one socket and 4 crimps
-intalled outside freezer hinge cover |
| 3374 | Brendan | 07/14/2025 | 00596 | -troubleshooted doorbell. bell got knocked out of whack, adjusted volume all set
-reduced volume on lane 2
-replaced UHC switch middle cabinet
-troubleshooted oven. NTF. Temped out correctly, timer working accurately, even the pies in the merchandiser looked normal. |
| 3373 | Adanel | 07/14/2025 | 00596 | -replaced middle heater switch
-fixed alarm button
-troubleshooted microwave but NTF |
| 3372 | Waylon | 07/13/2025 | 25383 | -Found freezer with no charge in it thought was weird don’t have any nitrogen so put a charge in found the leak was between condenser bulb line and compressor vapor line they rubbed together due to vibration overtime and both got holes in it recovered the charge confirmed with leak detector it wasn’t just condensate dripping and gonna have to come back when I get a new tank of nitro since brazing without nitro can damage other components and make a simple fix turn more costly |
| 3371 | Waylon | 07/13/2025 | 18198 | -cut out and removed old compressor and drier filter brazed on the compressor line extensions and access port brazed on access port for filter drier ran out of nitrogen so couldn’t braze anymore set up all the new copper line and expanded line sets once I get the nitrogen just have to braze 4 more spots then pressure test then charge and it should be good to go |
| 3370 | Waylon | 07/12/2025 | 18364 | Stopped by to check on multiplex at 33.6 degrees and has a perfect ice bath going had to add 1 Lb the other day since the data plate calls for 11 pounds then you need to factor in 25 feet of line to the roof which is about a pound since .72x25 =18 ounces |
| 3369 | Waylon | 07/12/2025 | 36960 | Frappe machine refrigeration was too warm the back of the unit was upside down for starters so no airflow could get out of the condenser and then took out charge and re weighed new charge in been temping at 36 for 20 mins calling it good
Unit will need new EPRs I n future last company striped them |
| 3368 | Waylon | 07/11/2025 | 11565 | -New muffin toaster element with Brendan was an absolute nightmare having two experience techs trying to go as fast as we can and we had to basically dissemble the whole unit and rebuild it from a piece of metal |
| 3367 | Waylon | 07/11/2025 | 18198 | -Recovered all refrigerant in system about 12 Oz waiting for compressor to arrive and install for front refrigerator found out that because of the inefficient compressor it looked like a bad txv which does explain my 230 degree liquid line which I’ve never seen before
|
| 3366 | Waylon | 07/10/2025 | 04205 | Long time on the grills basically needs a whole entire new air system everything in there breaks whenever you touch it replaced all airlines and got no airflow to the regulator so gotta replace compressor all the way to regulator |
| 3365 | Brendan | 07/10/2025 | 02830 | -lemonade NTF AGAIN |
| 3364 | Brendan | 07/10/2025 | 02038 | -installed replacement smart clock
-cleared AC trap and drain |
| 3363 | Jim | 07/10/2025 | 11565 | - removed and replaced two wall tiles by Drive thru 1
- installed corner trim on lobby partition |
| 3362 | Waylon | 07/10/2025 | 07194 | Readjusted grease plates and sprayed lube on then gapped grill tested 10:1 and quarter food safe
Fixed fry monitor not being aligned up on screen |
| 3361 | Waylon | 07/10/2025 | 18198 | -Soent some more time on lees refrigerator in window put gauges on find super high low side and high head pressure checked and cleaned condenser this did help it like 10-15 psig but 105 for the low side when it should be around 55 is ridiculous so I’m thinking bad TXV but this is the second time ever working on a txv and first time was the multiplex this week so having Rick come and make sure I’m right before any further work |
| 3360 | Jim | 07/10/2025 | 02038 | - completed freezer door panel installation |
| 3359 | Waylon | 07/09/2025 | 18364 | -Had to drive around to get a recovery tank since mine was contaminated for 404a finally got it then found out that the store didn’t even have the multiplex on…… so they turned it on this morning and to get it cold faster they kept dumping buckets of ice in it….. so just messed up everything pulled the charge from it found out it was basically a perfect charge but I couldn’t know since they messed with it multiple times took out charge and put the charge back in and much literally took forever and vacuumed system down whole thing was a mess that the store could’ve easily solved if they weren’t being dumb |
| 3358 | Jim | 07/09/2025 | 02038 | - picked up and started to replace the inner freezer door panel |
| 3357 | Waylon | 07/09/2025 | 18198 | -Fromt dt window wall refrigerator not running at 75 degrees got it running installed a temporary 3 n 1 it’s held together by just electrical tape at the moment got the compressor running which originally it would turn off instantly went down to 60 degrees gonna check on it in a couple hours since it’s a txv system r404a so it’s regulated and not gonna instantly drop to its set point |
| 3356 | Jim | 07/09/2025 | 04205 | - sourced and replaced can lite in lobby |
| 3355 | Jim | 07/09/2025 | 21582 | - taped and caulked sink backsplash
- installed ceiling tile y fry hopper
- filled pothole by curbside spot |
| 3354 | Jim | 07/08/2025 | 04205 | - replaced ballast on can lite above frappe machine
- removed lobby ceiling tile that was filled with water
- preformed a trash door anectamee ( replaced the bottom 12 inches of the steel door frame)
|
| 3353 | Waylon | 07/08/2025 | 18364 | Spent a little while on the multiplex first real txv system I’ve worked on so was definitely interesting learned that you always need to weigh the charge on TXVs so was something overcharged the unit at first and had to take some out it’s actively gone from 96 degrees to 62 so we are leaving it and gonna check back since it still might be slightly overcharged right now |
| 3352 | Brendan | 07/08/2025 | 18364 | -multiplex refrigeration issues. What a dousey
-ordered parts filet steamer |
| 3351 | Brendan | 07/08/2025 | 12272 | -replaced bun toaster fan |
| 3350 | Waylon | 07/08/2025 | 12272 | Bun toaster fan |
| 3349 | Waylon | 07/08/2025 | 04205 | -Fixed roof leak from AC unit
Fixed coffee brewer no power |
| 3348 | Brendan | 07/08/2025 | 04205 | -roof leaking was told was a waterline but clogged trap on the roof. all set
-coffee brewer breaker was off no issues
-under ABS dry as a bone NTF
-SSBS leak needs a new drain pan. will try to order if still available no promises.
-bypassed clogged filter |
| 3347 | Brendan | 07/07/2025 | 07194 | -troubleshooted FFLS. cleaned screen and recalibrated touch screen working fine now. |
| 3346 | Waylon | 07/07/2025 | 21582 | On days like this I’m reminded that I’m not a plumber, but anyways took out old drains of 3 bay sink installed 3 new ones and silicones those on the top then had to replumb the whole thing back to the grease box was a hot mess and a lot of work and a lot of cutting plumbers make it look easy but good lord that was a lot and then leak tested by holding water 2 times in each bay for five minutes then draining them and checked for leaks then ran water from faucet down all the drains for another leak test after confirming no leaks found it should be good (praying no call back on this sink for the rest of my life cause that was miserable) |
| 3345 | Brendan | 07/07/2025 | 12272 | -bun toaster diagnosed. needs a new fan. on order |
| 3344 | Brendan | 07/07/2025 | 16552 | -troubleshooted bun steamer. Hi limit tripped, I reset it and it came up to temp and didn’t overshoot so hoping it was a fluke |
| 3343 | Brendan | 07/07/2025 | 11565 | -troubleshooted bake monitor, bumper switch in wrong position
-fixed pos1 bsod
-troubleshooted muffin toaster. Terminal melted off and then the element snapped off while trying to unscrew the nut. new element will be replaced tomorrow |
| 3342 | Brendan | 07/07/2025 | 18364 | -troubleshooted multiplex. Seems to be low on charge. Will return with Waylon to recharge. Also noticed the condenser is in verrrryyy bad shape.
-troubleshooted satelite brewer. NTF filling the dispenser totally normally
-troubleshooted bulk ice machine. Taking over 20min for a freeze cycle very slow. Probably low on charge as well |
| 3341 | Waylon | 07/07/2025 | 07417 | Was told ice machine wasn’t working after I went for it last week but got in took cover of it was full of ice asked if they filled it nobody knows / said no and then it literally made ice as I was standing there with will soooo NTF |
| 3340 | Waylon | 07/07/2025 | 18198 | -Automist line replaced new line and new clamps
-Store fixed grill grease trap
-Installed new cord for table heaters |
| 3339 | Waylon | 07/03/2025 | 02038 | I’ve machine service call for Libby left one was working and full of ice right one well evaporator was only getting to 60 degrees sounded like a roof problem went on the roof and you know got the cover off the unit was greeted by two wasp nest filled with wasp alright got wasp spray killed over 10 of them and sprayed 3 nest boom start diagnosing capacitor was good fan motor not running which is why it’s not cooling trying to grab amp draw boom 4 more wasp show up I’m doing laps around this roof cause that 4ultiplied okay kill some more decide that I def don’t get paid enough for this which I never say that but getting chased by swarms of wasp wasn’t on the bucket list so I’m going to get off the roof and AWESOME there’s a wasp nest on the roof hatch ladder then I start debating the fact I’m almost out of wasp spray odds were not looking good decided packaged up the unit put all the tools together and sprayed the rest and got off the roof as fast as possible
Respectfully I never wanna go on derrys roof again unless it’s winter because every unit has multiple wasp nest in it |
| 3338 | Brendan | 07/03/2025 | 25383 | -crimped new connector on dt runner bump bar
-added and aimed the remaining three cameras. Installed hdmi splitter for cbb merge monitor, and cleaned up wires in office |
| 3337 | Waylon | 07/03/2025 | 07417 | Ice machine down turned off and on to begin it was making ice coil getting to about 32 degrees on the dot was about 10 minute freeze time 1 minute harvest time which is in the areas of good for the ice machine adjusted thickness probe a couple times and had to wait for ice to be made on each time think I got it in the perfect spot for a good ice bridge to form gonna check back at the end of my day to make sure it’s full and didn’t error out on anything |
| 3336 | Waylon | 07/03/2025 | 18198 | -Told coffee brewer wasn’t working came in was in service mode unplugged and plugged back in and waited for it to warm up and brew 3 pots |
| 3335 | Brendan | 07/02/2025 | 21582 | -replaced water booster pump and check valve. Water pressure good all equipment working |
| 3334 | Waylon | 07/02/2025 | 11565 | -Fixed muffin toaster heat b failure waited for it to heat up which it did no error code workings great pulling 6.6 amps
-Orange juice new contactor I didn’t diagnose it soooo had to learn the stupid Taylor orange juice machine which is STUPID like top 10 dumbest designs which is why the NH stores don’t have that piece of trash but found the part replaced waited for cabinet temp to hit 40 and called it good (store had product sitting in it at 60 degrees for idk how long which sounds very food safe) |
| 3333 | Brendan | 07/02/2025 | 02830 | -these absolutely nonsense ABS calls have to stop. I get the text that the ABS is acting up. I immediately look at the cameras (because I know they are full of bologna) and notice that SHOCKER they are using it totally normal... Get to the store and still everything is perfectly fine. "Acting up" is not a valid ticket. Machines do not work perfectly 100% of the time, just like computers they need to be turned off and on once in a while. Literally I am writing someone up the next time someone puts such a preposterous ticket. This store is wasting everyone's time with these ridiculous tickets.
-Melitta critical error caused be hot water solenoid leaking onto flowmeter and causing the connector and harness to rust and fail. Parts on order |
| 3332 | Brendan | 07/01/2025 | 02038 | -was called for AC off and apparently the thermostats were locked. I arrived and the lobby was entirely off but the thermostat was not locked so not sure why they just didn't turn it on. Adjusted other temps to be bearable. hung around for a little to make sure it was cooling and it was... |
| 3331 | Brendan | 07/01/2025 | 04205 | -emergency call for stockroom flooding from back flow preventer but I arrived and there was nothing everything dry as a bone... |
| 3330 | Waylon | 07/02/2025 | 16552 | -Came for shake machine ice cream side not seeing door was working when I got there
-Spent some time looking for the other companies shake machine tune up kit that we want to return
-Store was saying that they were being shocked by the refrigerator in grill oven and moffat which I thought like shenanigans started with the fridge cause that’s what the store was convinced it was when checking the outlet found the ground in the outlet to be fully corroded away which if there was no ground couple be shocking the outside so that was a major problem thought that was it then when moving the oven got shocked so there was two major shocking problems found in the oven 120 VAC wire for the fan fell off wouldn’t of even been noticeable if it didn’t hit the side and zap you so cut off old metal terminal replaced with plastic hooked up tested all set then jumped into the moffat since I already went through 2/3 pieces mine as well be certain that everything all good did each leg to ground and ground to ground make sure no splits in the plug or anything moffat came back fine outlet for moffat was a little sketchy with L2 to ground but I think the plug is just getting old / dirty but nothing to be concerned about since it all came back good |
| 3329 | Jim | 07/02/2025 | 02038 | -tightened vacuum tube on men’s room toilet
- removed old water filter assembly and replaced with new unit for dishwasher
|
| 3328 | Jim | 07/02/2025 | 17371 | - cleared urinal drain
- installed two screws to freezer threshold |
| 3327 | Waylon | 07/01/2025 | 25383 | -had to pickup cameras and installed walk in camera, freezer camera, outside license plate camera, installed 4 hard drives and crimped camera wires just need to be programmed in and slightly adjusted |
| 3326 | Jim | 07/01/2025 | 02038 | - repaired hand sink drain leaks
- re caulked diamond plate at sink
- installed six new drive thru signs and 3 posts |
| 3325 | Waylon | 07/01/2025 | 21582 | -Fixed fry station another different issue then last first socket receiving power worked none after because a broken wire replaced and all came on
-Was originally gonna say order a new dish sink between the drains needing to be replaced and the welding for the sink and the pipes needing new fitting but talked to Brendan since McDonald’s may break down the wall next to it for a longer sink for the dishwasher it doesn’t make sense to order the exact same sink just to replace it with a bigger one in a couple years so gonna order new drains and redo everything when it all comes in |
| 3324 | Jim | 07/01/2025 | 10544 | Cut and replaced two kitchen ceiling tiles
- cut, installed, and grouted white wall tile
- filled three potholes in parking lot |
| 3323 | Jim | 06/30/2025 | 10544 | - straightened and packed posts in tight, all six drive thru signs
- filled 5 potholes in parking lot |
| 3322 | Jim | 06/30/2025 | 02038 | - installed new door bell and button
- filled pothole by entrance |
| 3321 | Waylon | 06/28/2025 | 04205 | -emergency drain service by water heater got that one snaked and put cleaner down it waitied 15 minutes and washed out cleared up super easy and was draining a 5 gal bucket no problem
Second drain for ice machine gave me a super hard time snaked and drain cleaned multiple times till I got it to not overflow at all got it so ice machine and drain all into it no problem or back spill showed Lynn how to use drain o thinking of having them make it a weekly routine to put some down the drain since they have had this happen multiple times |
| 3320 | Brendan | 06/27/2025 | 25383 | -replaced ped13. Also replaced and mounted new paddle |
| 3319 | Waylon | 06/27/2025 | 17371 | -installed new frappe motor was a pain doing it all blind and going off feeling
-Grill fridge water going everywhere was from multiple things I found so sweating compressor and wasn’t hot signs of someone who was here last over charged it, that itself can kill a compressor ohmed out compressor it was still alive and pulling amps took out a little bit of refrigerant to desired point still having the problem inspected evaporator fan and evaporator didn’t see anything sticking out so pulled the charge from unit and vacuumed down to 500 microns or less twice put in a new fresh charge turned on came down to temp then didn’t turn on found a bad 3n1 ofc something else broke replaced that came down to temp working fine messed with the thermostat gauge a decent bit found the perfect point between 34-40 degrees told them not to touch it it still ices up a tiny bit when compressor is calling but right after it hits desired temp any frost goes away without dripping any water vs the flooding before |
| 3318 | Brendan | 06/27/2025 | 10544 | Under ABS was leaking. The drain hose was entirely out of the drain |
| 3317 | Adanel | 06/27/2025 | 21582 | -troubleshooted oj machine and the problem was that the water pressure is to low so to fix it the water bosster pump is broken: needs replacement
-replaced batteries on water fountait senson |
| 3316 | Brendan | 06/27/2025 | 21582 | -troubleshooted OJ machine not dispensing. Found water booster with failed pump. on order.
-troubleshooted hand sink not working. Just needed new batteries. |
| 3315 | Brendan | 06/27/2025 | 11565 | -troubleshooted ABS cup jam error. Syrupy connector for lift cylinder sensor. Cut connector out and replaced with ICD crimp
-troubleshooted juice machine. Found a bad refrigeration relay. on order |
| 3314 | Adanel | 06/27/2025 | 11565 | Troubleshooted abs machine. The arm didnt want to close. The problem was that the connector was wrong.
Troubleshooted orqnge juice machine and the problem is the contactor. |
| 3313 | Jim | 06/27/2025 | 36960 | - cut, replaced and grouted two base tiles by delivery door
- cut, replaced and grouted two base tiles by coke tanks
- snaked hand sink by kitchen sink, could not clear clog will need to call east coast |
| 3312 | Jim | 06/27/2025 | 02830 | - installed new toilet paper dispenser in men’s room
- replaced and grouted 1 floor tile in front of kitchen sink |
| 3311 | Adanel | 06/27/2025 | 36960 | -Troubleshooted the fryer 2 and 4. 2 it looks like its clogged and 4 smokes when turned on.
-women bathroom vent is working fine |
| 3310 | Brendan | 06/27/2025 | 36960 | -troubleshooted fryers. Vat 2 and 4 need new return valves and vat 6 smokes when on for more than a few minutes so definitely calling IFES for that.
-looked at womens room exhaust but NTF |
| 3309 | Waylon | 06/26/2025 | 21582 | -Got grill to heat up and they are cooking 10:1 on it deep cleaned the flame igniter
-Fixed lobby table that fell off I will be very impressed if they break it again also got liquid nails in my hair 😭 |
| 3308 | Brendan | 06/26/2025 | 00596 | -troubleshooted Qing oven, found bad auto-transformer and replaced |
| 3307 | Brendan | 06/26/2025 | 02830 | -replaced ketchup BIB pump and broken co2 connector
-rebooted ped6 |
| 3306 | Adanel | 06/26/2025 | 00596 | -troubleshooted the microwave
-replaced the auto transformer |
| 3305 | Adanel | 06/26/2025 | 02830 | -replaced ketchup pump |
| 3304 | Jim | 06/26/2025 | 16552 | - replaced broken tile by lobby present area and grouted
- checked sink drain issue, left sink missing stopper, will pick up replacement drain for it
- caulked and painted exterior lite pole cover |
| 3303 | Waylon | 06/26/2025 | 12272 | -fixed back sink leaking
-fixed grill under cooking and temped
-fixed back window latch needed new
-fixed crack by back door just needs some grout to go around seal but can’t be done for atleast 24 hours
-fixed frappe water line hanging from ceiling |
| 3302 | Jim | 06/26/2025 | 36960 | - cut and replaced ceiling tiles by restrooms
-patched hole in wall to left of lobby trash bin
- re set drive thru order here clearance poles
- patched sidewalk cracks and in front of exterior freezer door
- filled pothole by drive thru side two
- installed weatherstripping on delivery door
- installed new door sweep on back door |
| 3299 | Jim | 06/25/2025 | 02830 | - replaced two by four light above present window
- re installed light in men’s room |
| 3301 | Waylon | 06/25/2025 | 00596 | Qing oven diagnosed bad auto transformer shorted between 230 to 0 |
| 3300 | Waylon | 06/25/2025 | 02830 | -Bought a new led troffer must have a miscommunication with jim since he already fixed it
-found bad ketchup pump and ordered |
| 3298 | Adanel | 06/25/2025 | 18364 | -replaced 3 board corral
-cleaned delivery doar and apllied bomdo and primed it
-Found and reolaced cover for thr drain next to the shake machine
-Replaced wather strip on the delivery door
-Grouted women bathrooms walls |
| 3297 | Adanel | 06/25/2025 | 02830 | -replaced led light. |
| 3296 | Waylon | 06/25/2025 | 36960 | Installed new grill 1 platen 1 interface board ($1100) got platen 1 working re leveled it about 5 times make sure nothing went wrong
-I guess platen 2 isn’t working now also whole different issue not reaching heat on the front I diagnosed to the extent of the heat relay which is heating so hi limit or had element called Taylor they can service it seems like it’s a full day of work just for that part
- diagnosed behind counter lobby soda auger was tripping breaker everytime found bad motor capacitor was still good ordered new was like 1200 think Brendan got for 600 but crazy how much money is going into the newest store we have |
| 3295 | Jim | 06/25/2025 | 18364 | - replaced three boards on corral
- prepped and applied bondo on delivery door bottoms
- sourced and installed cover for floor drain next to shake machine
- replaced delivery door weatherstripping
- grouted ladies room walls |
| 3294 | Jim | 06/25/2025 | 10544 | - replaced 13 floor tiles and 9 baseboard tiles and grouted by delivery door
- re set rear door latch
- sourced and replaced kitchen sink spray handle and hose
- installed a California patch in crew room wall |
| 3293 | Adanel | 06/25/2025 | 36960 | -unclugged frappe machine |
| 3292 | Brendan | 06/24/2025 | 18198 | -bought hose and sprinklers to set up on the roof for K1 condenser |
| 3291 | Brendan | 06/24/2025 | 07417 | -replaced FC runner monitor |
| 3290 | Waylon | 06/24/2025 | 02830 | -took out front dt light Jim picking up new tmrw
-installed 3 light lens
-Cut and installed 2 tiles and grouted |
| 3289 | Adanel | 06/24/2025 | 10622 | -troubleshooted coffee brewer and it has a bad high limit. |
| 3288 | Brendan | 06/24/2025 | 10622 | -frappe machine was working upon arrival NTF
-coffee brewer was giving no water error, turned the unit off and on and worked after that. Experience tells me could be an intermittent high limit though so I will order that since I ran out |
| 3287 | Brendan | 06/24/2025 | 02830 | -remounted booster pressure tank |
| 3286 | Brendan | 06/24/2025 | 21582 | -recrimped two bump bar connectors
-replaced pos13 cash drawer and cable
-set up tablet with MDM |
| 3285 | Adanel | 06/24/2025 | 21582 | -remade 2 bumpbar cables.
-Replaced cash drawer
|
| 3284 | Brendan | 06/24/2025 | 12272 | -store had no FC printer because one of them was hidden in a cabinet for no reason, and pos2 printer wouldn't print because it was not plugged in... |
| 3283 | Brendan | 06/23/2025 | 07417 | -Troubleshooted melitta critical error. Was complaining that y34 wasnt ticking the counter. though after testing y34 it was working fine. I replaced the homogenizer and cleaned the outlets but the error persisted. I eventually figured out that y34 was failing only after at the end of a cleaning cycle when it overheated from cleaning the whole time. Replaced y34 and ran two cleaning cycles successfully
-activated and aimed walk-in cameras |
| 3282 | Brendan | 06/23/2025 | 02830 | -replaced kiosk 8 controller
-replaced dogging mech on lobby door
-troubleshooted fryer power issues was a massive headache. Ended up being a charred terminal block in the Ansul chase but a big pain to work in but managed to get it |
| 3281 | Jim | 06/23/2025 | 18364 | - menu board repaired
- sourced and installed mixing valves in ladies and men’s room sinks
- adjusted water temp in hand sink by fry station
- welded plastic bag holder attached to the paper bag holder
- filled hole in sidewalk
- cut and installed three small tiles by booths
- installed new spray hose and spring |
| 3280 | Adanel | 06/20/2025 | 25383 | -troubleshooted multiplex that kept tripping the beaker. loose wire kept was touching electrical panel cover. all fixed.
-finished and aimed new lot cameras |
| 3279 | Brendan | 06/20/2025 | 25383 | -troubleshooted multiplex that kept tripping the beaker. loose wire kept was touching electrical panel cover. all fixed.
-finished and aimed new lot cameras |
| 3278 | Jim | 06/20/2025 | 10622 | - removed plastic stop on fry vat door, closes and latch’s fine
- re attached kitchen sink tower to wall mount and re fastened left soap dispenser
- repaired hole in crew room wall and sanded smooth |
| 3277 | Waylon | 06/20/2025 | 02038 | This was the definition of a waste of time just drove out here for frappe machine refrigerator not temping out and I walk in the cabinet and dispense head are at 36 degrees and 35 so like sick just drove out here on overtime for that to do nothing
Asked store sometimes they don’t fully close the door causing it to look like it’s not temping out right CAUSE THEY CANT CLOSE A DOOR are we serious |
| 3276 | Adanel | 06/20/2025 | 10544 | -we have to replace the gabinet strips
-we have to order a water hose for the dish sink
-ice machine hose was out. |
| 3275 | Brendan | 06/20/2025 | 10544 | -ABS under filling NTF
-water under ABS, ice bin pipe was not in the drain
-ordering dish sink sprayer hose
-ordering 4 cabinet strips |
| 3273 | Waylon | 06/19/2025 | 25383 | -Cameras outside work and freezer / walk in line runs
|
| 3274 | Waylon | 06/20/2025 | 18198 | -Installed abs drain had to braze fitting on and then crimp bottom hose to drain leak tested and sent video to Brendan |
| 3272 | Waylon | 06/19/2025 | 18364 | -Fixed dt runner monitor not working picked up a replacement just in case
-Disgnised ice machine rooftop refrigeration issue contacted company |
| 3271 | Waylon | 06/18/2025 | 25383 | -Camera installs and pulling wire |
| 3260 | Adanel | 06/18/2025 | 16552 | -Replaced hose and sensor for the water in the baseman
-fixed toaster chain was lose, needs bushing replacement |
| 3270 | Jim | 06/19/2025 | 04205 | - replaced emergency exit sign above delivery door
- lifted and secured ceiling over grills in three places
- installed two new bulbs in freezer light
- R&R kitchen hand sink. Remounted wall plate and installed new down pipe gasket and caulked sink to wall |
| 3269 | Jim | 06/19/2025 | 02830 | - replaced five floor tiles and grouted, 2 by fry vats , 2 in front of walk in, 1 in walk-in |
| 3268 | Adanel | 06/19/2025 | 00596 | -Went to see a door problem but apparently it was fixed by magic🤣 |
| 3267 | Adanel | 06/18/2025 | 25383 | -Helped install new camera system
-we still got some stuff to do |
| 3266 | Brendan | 06/18/2025 | 16552 | -replaced water line with hole and leaking pressure switch on water booster
-fixed bun toaster kind of. needs a new bushing but got it working for now |
| 3265 | Brendan | 06/18/2025 | 00596 | -door latch NTF |
| 3264 | Brendan | 06/18/2025 | 25383 | -camera upgrades. Inside complete, will return tomorrow to do outside and walk-in cams |
| 3263 | Jim | 06/18/2025 | 07194 | - re set do not enter sign
- changed spud assembly on men’s room urinal
-replaced cover on light pole
- re fastened foot rest next to kiosk (only on loose) |
| 3262 | Jim | 06/18/2025 | 02830 | - sourced and installed 5 new bolt caps at slat wall in lobby
- replaced and grouted one base tile behind bun racks
- grouted floor area by front ice bin
- replaced delivery door weatherstrip
— picked up 4-4 pals of kitchen ceiling tiles |
| 3261 | Waylon | 06/18/2025 | 36960 | -respectfully and kindly and sincerely fuck that grill such bullshit working on left platen grill 1 again got my parts in went down put in the motor board NOPE doesn’t fix it LIKE FFS then call Doug he said sometimes the motor before last doesn’t work cool awesome Brendan and I agreed valid replaced both motors NOPE and the whole time I was saying motors are fine it seems like a cord problem or main board down below but the motor was receiving power so it should be turning it wasn’t turning like my brain hurts from this grill so I’m ordering a cord testing kit for my van but to test their stupid bs cords WHICH THE MOUSE PROBABLY CHEWED with my luck and gonna order a main board praying it’s not the main board cause that’s 1100 either way whole lotta bullshit and it’s frustrating the amount of motors I’ve put into this stores grills I think I’m at 6-7 and they’re 300 a piece like fuck these grills and why are they gas like CMONDMFJDNSND |
| 3259 | Waylon | 06/17/2025 | 25383 | Emergency call for grill being down both platens got their knew it was a problem with the pneumatic system found compressor receiving power not running so needs a new compressor and ordering a new high pressure switch only because theirs burn marks on the side of the inside of it, it does work atm but that’s preventive care for a problem in the future |
| 3258 | Waylon | 06/17/2025 | 02830 | -Move crew rooms tuff to office
-Contacted Casco regarding all the fryer issues
-Fixed the thermostat in office problem
-grabbed a ceiling tile to get it matched
-Cleared the fc problem fixed it prior |
| 3257 | Brendan | 06/17/2025 | 00596 | -waterline exploded under the ABS had to replace the line that went from prechiller to ABS
-replaced frappe machine quick connect line and fitting on the machine |
| 3256 | Waylon | 06/17/2025 | 25383 | -Fry hopper added charge to it got it down to correct reading psig about 8-10 I have it at 11 incase theirs a small leak but makes the set point 0-5 degrees ish realistically anything below 10 I’m good while I was there went from 68 down to 22 originally didn’t do anything found 3 plastic gloves and a layer of dust covering the condenser coils did not deep clean it just brushed the front so I could feel air flow through
-Back dt heater found out tis not a heater it’s a god damn air handler in the ceiling which was very intimidating in the beginning but fixed that was shorting out and replaced wires that were shorted tested old ladies out back said they’re happy with it and all good |
| 3255 | Brendan | 06/16/2025 | 00596 | -removed a few wall shelves and stuff to make room for water upgrades. Will relocate them after finished. hung around for a while to make sure they didnt need anything |
| 3254 | Brendan | 06/16/2025 | 18198 | -finished running new ABS network wires, installed box and coms and left IP info for installers. Also turned off ice machine water |
| 3253 | Jim | 06/16/2025 | 10544 | - worked with Adanel on fence Got all but one hole dug. All holes had very large roots blocking them |
| 3252 | Adanel | 06/16/2025 | 10544 | -worked with jim in fences, digged holes. |
| 3251 | Waylon | 06/15/2025 | 02830 | Diagnosed sparking from the frystation got there and was told it was the fryer originally assumed sparking bursting outward outlet problem outlet and plug were fine breaker was tripped so reset and when heat was called contactor pulled and tripped bad contactor |
| 3250 | Waylon | 06/15/2025 | 36960 | -Grill platen 1 originally thought motor until when opening it up I saw the motor to be speculated bad was brand new within last year so started to poke around and I believe the motor supply board is bad and not the motor because when swapping the slot of which motor goes where on it everytime all motors worked except the one plugged into the motor supply 1 slot which gives me reason to believe that’s the route of the issues so ordered that and ordered all the motors I’ve used on these grills for van supply |
| 3249 | Waylon | 06/15/2025 | 16552 | -Chain came off one of the gears but getting it back on had to take off the top gear and between it being extremely hot and I don’t have any basic wrenches I had to do it with my finger and so it’s finger tight hopefully that keeps it on and together gonna order a new chain though since it was in rough shape
Not a fan of working in this store between it being extremely small and everyone bumping into each other and found multiple oeps missing screws holding the plug in which is an absolute joke and then the bun toaster has a drop down part that holds the display board as you work on it nope not this one this one has had it all removed and you have to hold up the display board as you work on it just a complete stupid joke |
| 3248 | Waylon | 06/15/2025 | 12272 | -Water line broke and my very smart self brought 2 out of 3 of the sizes of water line cause it looked small in the photo nope it was a 1/2 inch line so went to Home Depot got some pex found out pex isn’t like typical water line where you can put it in a cup of water and it’s flexible nope had to take out the torch and then crimp it on anyways water line is fixed and turned back on shut off valves no leak |
| 3247 | Waylon | 06/13/2025 | 21582 | Had Brendan show me how to do one of the new door push bars because the instructions were very intimidating and I didn’t wanna drill a bunch of holes in the door trying to get it right but fixed both back doors and installed one new push bar |
| 3246 | Waylon | 06/13/2025 | 02038 | -cleared drain by walk in
-Adjusted drain by ice machine the line going to the top box was off to the side dumping on the ground
-let adanel install new drain pan for frappe machine
-Cleared drain pan line |
| 3245 | Adanel | 06/13/2025 | 21582 | -Installed door pushbar
-exit device |
| 3244 | Brendan | 06/13/2025 | 21582 | -Waylon needed help installing new push bar and repairing old one on other door |
| 3243 | Adanel | 06/13/2025 | 02038 | -unclugged frappe machine
-installed drain part for the frappe machine |
| 3242 | Brendan | 06/12/2025 | 04205 | -attempt #3 at pickup up new washer. Successful this time. Picket up and installed |
| 3241 | Brendan | 06/12/2025 | 02830 | -wasted a whole trip. Was going to replace the fry computer that they said didnt have working buttons. But come to find out 2 of the buttons work perfectly, and one of the buttons works you just have to press a little harder. So they only have 1 broken button. There are 3 working buttons for only two spots to drop fries. Definitely not spending $2k on a computer to fix one button that will never get used anyway...
-was going to install kiosk controller but must not have arrived yet, will call to find out
-was going to finish replacing the two FC card readers for p400 upgrades but the store apparently lost them because they are not in the store anymore.........
-also ABS YET AGAIN working completely fine. They were using it the day the ticket was put in I noticed on the cameras. I should not have this many NTF calls to a store. if problem is intermittent enough to where it never happens when i'm here, it is intermittent enough to not be added to the list.... |
| 3240 | Adanel | 06/12/2025 | 02830 | NTF |
| 3239 | Brendan | 06/12/2025 | 00596 | -troubleshooted women’s room flusher. Thought it was the solenoid at first, so went to Grainger to pick up. Replaced the solenoid but then found out the magnet for the manual flush button fell off, so need to order that part |
| 3238 | Adanel | 06/12/2025 | 00596 | -replaced women bathroom solinoid, push button is damaged. Needs replacemnet |
| 3237 | Brendan | 06/12/2025 | 07194 | -replaced bump bar
-troubleshooted merge point camera. Dead camera. Will push this store next in line for camera upgrades |
| 3236 | Adanel | 06/12/2025 | 07194 | -replaced bumpbar
-troubloshooted dt camera, needs replacement. |
| 3235 | Brendan | 06/10/2025 | 04205 | -replaced side 2 breakfast monitor
-troubleshooted washing machine, in need of replacement. Went to stores to try to find replacement but not in stock until tomorrow
-troubleshooted mens faucets not working. Cold water handle was loose needed to be tightened but thats it |
| 3234 | Waylon | 06/11/2025 | 36960 | -got platen 1 on grill 1 display working now it won’t come out of auto level so I will have to go back for that problem
-Platen 5 grill 2 broke as I was working on 1 the motor locked up and needed new motor
Back to grill q when opening it searching through wires for the display found a mouse running around how he’s still alive blows my mind but he has been named Miguelito tried getting him out and it’s a little fast guy homie is in shape eventually gave up and decided he’s gonna chew or step on the wrong wire and kill himself but homie is a climber wondering if my second issue with platen 1 is because of miguelito |
| 3232 | Waylon | 06/11/2025 | 11565 | -Drain back up dish sink walked in and it was cleared just wish they told Brendan ran water through it to make sure |
| 3231 | Waylon | 06/11/2025 | 18364 | -Installed new ballast and new light lens since the other was already broken and falling out |
| 3229 | Waylon | 06/11/2025 | 12272 | -installed new UHC switch old one gave me a very hard time trying to rip it out and broke it into 3 pieces but was kinda ridiculous waited for it to come up to temp range |
| 3228 | Adanel | 06/10/2025 | 04205 | -Replaced kitchen monitor
-troubleshooted washer machine needs to be replaced |
| 3227 | Waylon | 06/10/2025 | 21582 | -fixed fry station broken wire going into first socket broke causing them all to go out
-Back door not latching for it to latch now it’s stuck latched cause the push bar is also broken lmao Brendan ordering for both doors cause the others doors latch is stuck in |
| 3226 | Waylon | 06/10/2025 | 10622 | -Installed grill relay came up to temp food safety checked ✅ good diagnosis yesterday |
| 3225 | Adanel | 06/10/2025 | 07417 | -installed freezer camera
|
| 3224 | Brendan | 06/10/2025 | 07417 | -ran wire and installed cameras in walk in fridge and freezer |
| 3223 | Waylon | 06/10/2025 | 18198 | -Lobby soda temping at 70 degrees installed new 3n1 kicked the compressor on which is great cause originally looked like a faulty compressor then compressor kept turning of which meant it was overheating when checking my pressure found 250’psig on high side which is excessive pressure pointed me toward the condenser coil brushed clean the whole outside condenser coils didn’t make a difference took nitro and blew through it sent dust everywhere but worked started to coming down in temp had to clean up the electrical and test the soda multiple times ran all the lines through to get fresh soda in all of them and at proper temp
Working when left - soda at 34,5 degrees found a small leak in refrigerant line capped it and leak tested will need to be fixed in the long run |
| 3222 | Waylon | 06/10/2025 | 18198 | -Lobby soda temping at 70 degrees installed new 3n1 kicked the compressor on which is great cause originally looked like a faulty compressor then compressor kept turning of which meant it was overheating when checking my pressure found 250’psig on high side which is excessive pressure pointed me toward the condenser coil brushed clean the whole outside condenser coils didn’t make a difference took nitro and blew through it sent dust everywhere but worked started to coming down in temp had to clean up the electrical and test the soda multiple times ran all the lines through to get fresh soda in all of them and at proper temp
Working when left - soda at 34,5 degrees found a small leak in refrigerant line capped it and leak tested will need to be fixed in the long run |
| 3221 | Waylon | 06/09/2025 | 36960 | What a headache
Believe girl 1 needs new main board plugged display into board next to it came on but in main doesn’t work
-Installed 2 motors into grill 2 platen 1 one was seized couldn’t turn and the screw to loosen it was locked underneath it took forever to get out was miserable and platen 2 was working fine and cooking proper 10:1 once fixed platen 1 took probably 20 mins to communicate doing food safety so I could leave 😭 |
| 3220 | Waylon | 06/09/2025 | 10622 | -Disgnosed grill after it tripped a breaker needs a new SSR |
| 3219 | Adanel | 06/09/2025 | 10544 | -fixed fuset
-insulated tubes under abs.
-installed door handle.
|
| 3218 | Brendan | 06/09/2025 | 10544 | -water leaking from ABS seems to be just condensation. Insulated the pipes so should be all set.
-replaced standpipes for back hand wash sink
-replaced entry door handle |
| 3217 | Brendan | 06/09/2025 | 11565 | -troubleshooted frappe machine not dispensing. An open BIB valve caused the pump to keep pumping with no valve and it stole the pressure. closed valves that were not in use and works now.
-PED rescued ped8
-fixed filet steamer leak, replaced cracked filter bowl
-troubleshooted PED 1 no network. forgot my cable tester at another store though unfortunately
-fixed BSOD POS 1 |
| 3216 | Adanel | 06/09/2025 | 11565 | -rescued kiosk 8 ped
-tried fixing register 1 ped.
-replaced filter in filet machine
-troubleshooted frappe machine |
| 3215 | Brendan | 06/09/2025 | 16552 | -leaking from carbonator pump. Crimp fell off, replaced water line and crimp
-fixed printer pos2 |
| 3214 | Adanel | 06/09/2025 | 16552 | -water pump was leaking
-it had a bad clamp, replaced it all working right now. |
| 3213 | Brendan | 06/09/2025 | 02038 | -RHS offline, indicated it was overheating. Somehow the fan fell off. Screwed back on all set |
| 3212 | Waylon | 06/09/2025 | 18198 | -Lobby soda not carbonated found refrigeration problem speculating bad compressor need to pick ups. 3n1 for final test |
| 3211 | Adanel | 06/09/2025 | 02038 | -troubleshooted rhs that was offline
-fan fell off
-everything working |
| 3210 | Adanel | 06/07/2025 | 02038 | Replaced all PED in the front counter and kiosk |
| 3209 | Brendan | 06/07/2025 | 02038 | -p400 upgrades |
| 3208 | Waylon | 06/06/2025 | 11565 | -Emergency drain call for frappe machine has to replumb it in |
| 3207 | Adanel | 06/06/2025 | 16552 | -Replaced card reader due to not being able to use the chip reader |
| 3206 | Adanel | 06/06/2025 | 21582 | -fixed phone line a cable was out of the connector |
| 3205 | Brendan | 06/06/2025 | 21582 | -phone line not working, the wires ripped out of the modem. Crimped new connector on, all set |
| 3204 | Adanel | 06/06/2025 | 12272 | -troubleshooted frier machine, bad board
-replaced multiplex thermometer
-fixed hme |
| 3203 | Brendan | 06/06/2025 | 12272 | -troubleshooted 3 cats not working. Calling casco
-replaced multiplex IBC probe and controller, and agitator motor
-fixed zoom timer, had an IP conflict |
| 3202 | Waylon | 06/06/2025 | 18198 | -Installed new electrical outlet for chill rail
-ran 2 new Ethernet wires for new abs installation from tech rack to abs top |
| 3201 | Jim | 06/06/2025 | 25383 | - replaced and grouted two floor tiles by delivery door
- replaced four bulbs in walk-in and freezer
- repaired landing zone cord
- cut and installed new lite lens above ice bin
- replaced three bulb ballast in Stock room |
| 3200 | Waylon | 06/05/2025 | 25383 | Installed new camera merge point box
-fixed leaking prep sink |
| 3199 | Waylon | 06/05/2025 | 10544 | -fence rebuild got one pole in 2 other holes started digging this is gonna take a long time
-Dish sink sprayer fixed |
| 3198 | Brendan | 06/05/2025 | 04956 | -replaced batteries in k1 sensor
-kiosk 6 jammed
-found source of co2 leak. Come tank co2 fitting loose. Vented tank and tightened |
| 3197 | Jim | 06/05/2025 | 10544 | - worked with Waylon on the damaged perimeter fence |
| 3196 | Jim | 06/05/2025 | 00596 | - re attached three boards on corral |
| 3194 | Brendan | 06/05/2025 | 07194 | -replace melitta spout cover
-fixed presell board not showing content |
| 3193 | Brendan | 06/05/2025 | 18198 | -picked walk-in lock |
| 3192 | Brendan | 06/04/2025 | 18198 | -measured for clearance for new ABS
-dt mirrored runner screen not working just on wrong input |
| 3191 | Brendan | 06/04/2025 | 07417 | -replaced dt window 2 motor and thumb lock
-replaced dead pos15 |
| 3190 | Waylon | 06/04/2025 | 21582 | Installed new oven had to do one leg at a time to install casters and jack it up moved old to trash corral and tested cookies in new oven
-Grill was working when I got there and Matt said he hasn’t had a problem with going too remove from list |
| 3189 | Waylon | 06/04/2025 | 10544 | -Abs leak, I couldn’t find anything definitive searched the whole bottom all set one hose wasn’t in the drain (could be problem) and tightened all the clamps incase it was leaking from a hose but couldn’t find a definite source was almost dry when I Got there
-Diagnosed ice machine not working seems to be a GFCI outlet behind coffee brewers needs to be fixed still (not doing till morning when I can shut off breaker from doing it at that angle seems dangerous live)
-grabbed measurements to order new door handle and push bar
-Fixed dish sprayer leaking still suggesting order a new one since it’s a tiny tiny leak now instead of spraying you in the face
-tightened woman’s toilet down
-Drive thru fridge is barelyyyyyy leaking water and still coming down to temp leaving to Rick if any other refrigeration issues pop up on that store really not a big deal |
| 3188 | Jim | 06/04/2025 | 02830 | - replaced 7 floor tiles in freezer and grouted
- replaced three floor tiles to the left of walk- in door
- repaired outside freezer door and painted
- fastened freezer threshold and & grouted floor tile |
| 3187 | Adanel | 06/04/2025 | 25383 | -troubleshooted dt camera. Part ordered
-replaced slushie blades
-frier was clogged
-replaced bulb on the emergency lights
-replaced emergency light cage
|
| 3186 | Brendan | 06/04/2025 | 25383 | -replaced two bulbs for emergency light in vestibule
-replaced emergency light unit near off
-replaced cherry FCB beater spinner parts
-troubleshooted camera monitor, seems like a bad power splitter box. on order |
| 3185 | Waylon | 06/04/2025 | 07417 | -Fixed broken pipe drain on grill sink
-Filled gashes in table with wood filler have to go back for sanding and to try and paint it |
| 3184 | Waylon | 06/03/2025 | 02830 | -Installed 4 tiles and grouted
-Fry station was a straight disaster needed 2 sockets a light broke in one then a 3rd socket broke on the inside the electrical was so backwards like the fact no one has been shocked is just straight lucky so had to fix all that and then switch was giving some trouble but got it to work
-Installed new card reader back window
-Fixed flap outside walk-in door screwed down and put liquid nails on it before screwing |
| 3183 | Adanel | 06/03/2025 | 00596 | -replaced transformer from the side 2 heater
-replaced water regulator inside frappe machine
-replaced co2 connector frappe machine |
| 3182 | Brendan | 06/03/2025 | 00596 | -replaced air connector frappe machine
-replaced water regulator
-replaced side 2 HLZ transformer |
| 3181 | Brendan | 06/03/2025 | 04205 | -replaced ABS drain fitting |
| 3180 | Jim | 06/03/2025 | 02830 | Cut out 4 floor tiles, one by front register, one by fry station, two by the fry hopper |
| 3179 | Waylon | 06/03/2025 | 10622 | -Looked at grill checked voltage at stepper motor came back good checked switch to make sure motor was hitting it to click was good inspected wires all good fixed a belt off the pulley could that be the cause maybe doubt it though they were using the grill when I walked in another intermittent problem… motor looks like it’s lived it’s life and from how they explained the problem makes me think motor but if it’s still working 90% of the time mines well keep going till it dies (motor is corroded and rusty from 2017) |
| 3178 | Adanel | 06/03/2025 | 11565 | -replaced conncetor in frappe machine
-troubleshooted camera dt
-everything working |
| 3177 | Brendan | 06/03/2025 | 11565 | -replaced air connector frappe machine
-troubleshooted dt cameras, crimped new connector |
| 3176 | Adanel | 06/03/2025 | 16552 | -installed the pump for the coke
-calibrated both abs and front beberage machine
-fixed abs arm |
| 3175 | Brendan | 06/03/2025 | 16552 | -installed BIB coke and calibrated both stations |
| 3174 | Waylon | 06/03/2025 | 17371 | -UHC call for distribution board ordered one last time I was here but it was working when I got to store and was working when j got to store today install distribution board based of good faith since it’s working everytime I’m here I can’t diagnose it I have one other theory on the power supply board being intermittent but for now gonna hope the error code was right and just needed a new distribution board |
| 3173 | Brendan | 06/03/2025 | 12272 | -troubleshooted multiplex. Bad IBC probe, unit was solid ice. also agitator was off. Bad carb A pump as well. On order and need to wait for ice to thaw
-ABS leak from clogged ice bin drain, all cleared
-reattached dt window 2 chain |
| 3172 | Adanel | 06/03/2025 | 12272 | -troubleshooted abs machine, it is a big block of ice. Coming back to fix the looping pump.
-Fix abs leakage. Ice drainer was clogged |
| 3171 | Jim | 06/03/2025 | 18364 | - snaked dishwasher drain and found silicone disc in drain ,
Let shift manager that the screen needs to be in drain pan always |
| 3170 | Jim | 06/03/2025 | 02830 | - installed ten floor tiles at walk-in entrance |
| 3169 | Jim | 06/02/2025 | 02830 | - cut out ten floor tiles at walk in and prepped floor , will install new tile in the morning |
| 3168 | Jim | 06/02/2025 | 25383 | - replaced main sink faucet complete
- removed and replaced parking lot wooden guard rail |
| 3167 | Jim | 05/30/2025 | 04956 | - replaced washing machine |
| 3166 | Waylon | 06/01/2025 | 25383 | -Diagnosed emergency light not working in vestibule bully charged battery no power to head after turning breaker checked power into head at board no power received bad board need new unit
-Noticed when testing first emergency light the officer door emergency light also not working with breaker off test same diagnosis as the vestibule one needs new unit 12v other 6v
-Fixed Ethernet cord crimped wrong on tech rack and reset and tested
-Window 1 changed from automatic to manual ripped out all the old saved good parts angle grinder motor bracket off and installed new plate
-Installled new manual handle for dt 1 window tested and showed manager all are tapped and screwed no rivets |
| 3163 | Brendan | 05/30/2025 | 11565 | -installed equipment for BIB coke, ran the syrup line, and brixed ABSs |
| 3165 | Waylon | 05/30/2025 | 18198 | -Installed 3 egg crates and sourced cut up 3 spares since they go through them so often
-installed new fry socket
-Went over if they need a ramp guess they don’t all of sudden removed from list
-Create a plan for electrical in grill ordered a 125 v oep and gonna rewire into that so we don’t need to add a whole new outlet in
-Helped open and dispose of an extra part ordered for simplified breakfast that was unnecessary |
| 3164 | Adanel | 05/30/2025 | 11565 | -installed pump and lines of coke. Everything is working right now. |
| 3162 | Adanel | 05/30/2025 | 04205 | -troubleshooted Abs
-replaced sprite sensor |
| 3161 | Adanel | 05/30/2025 | 02038 | -Troubleshooted sugar machine
-screen was broken
-replaced screen
-all working |
| 3160 | Brendan | 05/30/2025 | 04205 | -replaced sprite sold out switch fro ABS |
| 3159 | Brendan | 05/30/2025 | 02038 | -replaced sugar dispenser front panel and melted lid |
| 3156 | Adanel | 05/28/2025 | 11565 | -Troubleshooted motor
-replaced bad multiplex motor
|
| 3158 | Waylon | 05/29/2025 | 21582 | -fixed hlz was right about heat relay stick on replaced and tested
-welded table holders next to fryer |
| 3157 | Jim | 05/29/2025 | 02830 | -had to rebuild top of door frame due to screws being torn out. Tried welding holes but metal was too weak and blew out so I cut a square out and welded in new metal.
Drilled and tapped new holes and install new screws
Re mounted door closer |
| 3155 | Adanel | 05/29/2025 | 25383 | -installed tech rack
-troubleshooted abs system flushed
-multiplex motor bad needs replacement
-pump also needs replacement is leaking
-installed an access point
|
| 3154 | Brendan | 05/29/2025 | 25383 | -troubleshooted multiplex, bad circ pump causing breaker to trip. Will return to replace motor
-tech rack install |
| 3153 | Waylon | 05/29/2025 | 00596 | HLZ the cord was literally ripped out of it.. so would explain why it doesn’t work took it out put two electrical nuts in the sides to lock it into place yanked on it to make sure it was good then replaced fuse probing around was wondering why it wouldn’t turn on at the transformer the terminals were wiggly so k pressed my probe up to the right one and it turned on when pushing into it and turned off if I let up so held it there to keep it on ran it came up to temp no problems no short gonna order new transformer and hopefully that’s the end of this hlz being a problem
-Moved window signs up to the second to last chain link left the extra chain on the back of the sign since I get the feeling we will be asked to move it down in the future…
Followed up on rick taking care of the freezer found out there was miscommunication and no one texted him so texted him |
| 3152 | Waylon | 05/29/2025 | 18198 | -Walked in saw the frappe machine was still down little confused cause typically Taylor is out first thing in the morning for it so made sure a service call was submitted never was……………… and the machine was never cleaned……… asked Michael to have someone clean it
-Grill had runny eggs they asked me to gap check it I did but then found out they never tried scraping the grill for carbon build up… which it’s the middle of the platen and all the sides are fine. |
| 3151 | Waylon | 05/28/2025 | 18198 | -Chrcked pressure on frappe machine for not coming to temp had no charge unit dumped all refrigerant charge leaking EPR valve told store to call Taylor and put in a service call with them and to clean out the machine of all product so it doesn’t spoil and smell |
| 3150 | Waylon | 05/28/2025 | 02038 | -tried fixing freezer door that is destroyed just made it so no one else will hurt themseleves on it hopefully went to a sheet metal guy he said he can get to it next week we just have to install it
-Sugar dispenser actually gave me a run for my money on this one was receiving power and this things never break traced power through had to create a new Ethernet test connection to see if I was getting voltage to display board was receiving volts to display board but wasn’t working so bad display |
| 3149 | Brendan | 05/28/2025 | 11565 | -returned for soda water not working after getting new co2 tank. Carb motor died. Didn’t have a new one on hand so I took the old abandoned ones and it works, for now… taillight warranty on this one |
| 3148 | Adanel | 05/28/2025 | 25383 | -Replaced igniter
-tried fixing the window but coulnt.
-had motor and main board replaced(still not working) |
| 3147 | Brendan | 05/28/2025 | 25383 | -replaced igniter with correct part right fry vat
-replaced board on dr window 1 with no luck… frustrating… |
| 3146 | Adanel | 05/28/2025 | 11565 | -installing compresor |
| 3145 | Brendan | 05/28/2025 | 11565 | -installed air compressor |
| 3144 | Jim | 05/28/2025 | 21582 | - replaced two corner trim by rear hand sink
- repaired crack in FRP connector by trash door
- installed door sweep on outside of delivery door |
| 3143 | Waylon | 05/28/2025 | 17371 | -Came up for cabinet not working distribution board error tested voltage came to temp for me turned on and off 4 times came up to temp everytime no problem they showed me a video of it happening and said it happens every morning so gonna order a distribution board to lee and keep it in my van but not sure how much I trust it
-Gapped grills seems like the platen 3 doesn’t wanna hold gap to well but it’s cooking and the meat is food safe and looks good so not gonna dig into it more
|
| 3142 | Jim | 05/28/2025 | 04205 | - refastened railing by frappe machine
- adjusted front left leg. To hold sink stable
-replaced Damaged weatherstripping on trash door
- installed cork board and file basket by drive thru window one
- checked lobby door and it still closes with no issues, the threshold is visibly worn down.
|
| 3141 | Jim | 05/27/2025 | 25383 | - finished the repairs to the corral and remounted gate pins
|
| 3140 | Waylon | 05/27/2025 | 11565 | Frappe machine installed new drain removed old had to reconnect drain lines and clean out replaced co2 oring needs new co2 fitting
- helped retrieve co2 tanks from Pelham for store about to run out |
| 3139 | Brendan | 05/27/2025 | 04205 | -ABS sprite, working fine. NTF
-fryer outsourced |
| 3138 | Brendan | 05/27/2025 | 21582 | -was able to yank out cleaning brush from ABS staging tray, took a lot of force.
-diagnosed oven probe fail. Bad computer, on order. |
| 3137 | Waylon | 05/27/2025 | 18364 | -Grill platen 2 not cooking the times were set off and checked gap
-Filet steamer not working (hi limit tripped) once reset steaming stuck on turned off and back on and reset tested and worked recommended new regulator (broke can’t adjust psi), new water line looks on the verge of breaking and leaking plus no push connect end and new water solenoid - Brendan told me to hold off on that since it’s working atm
-Cream dispenser bottom is separating not fixable needs new one
-Ice machine cover taped up screw holes have been broken for a long time doesn’t sell that top anymore ice machine is from 2006 lived it’s life tbh
-Water backing up at dish sink into dish washer is a clogged grease trap outsourcing Brendan is calling |
| 3136 | Adanel | 05/27/2025 | 25383 | -second window camera monitor not working/replaced
-troubleshooted DT camera in the second window
-replaced monitor
-replaced cable tip
-working now |
| 3135 | Brendan | 05/27/2025 | 25383 | -worked on replacing fryer ignition control and igniter. Igniter was too short incorrect part so I have to order the correct part, but it does work so success.
-replaced bnc connector on dt merge monitor |
| 3134 | Waylon | 05/27/2025 | 02830 | -Abs cleaned sensors and test ran 9 sodas in a row no problem
-Gapped platen 2 and 3 had them food safety tested
-Qing oven handle loose tightened as tight as that will get without ordering a new one they are generally that loose though
-Talked with Mary and Anne regarding drier it was just a dirty screen has been working since Anne cleaned it so didn’t go into it any further |
| 3133 | Waylon | 05/27/2025 | 04956 | -Bent bun toaster metal piece back hopefully that fixes looked at doesn’t seem to be scraping at all told them to give it a shot
-Tried finding ice bin model number couldn’t find anything so gave Brendan the ice machine model and gonna see if he can find it
-Washing machine has a bad computer only works in one cycle
|
| 3132 | Adanel | 05/27/2025 | 02038 | -Troubleshooted abs machine, founs the ice paddle bent and replaced the ice gate. All working correctly! |
| 3131 | Brendan | 05/27/2025 | 02038 | -troubleshooted ABS ice gate fail. Replaced ice gate and found paddle was bent. Corrected, all working. |
| 3130 | Jim | 05/23/2025 | 21582 | - replaced two ceiling tiles that were missing
- cut and installed new ceiling tile above drive thru one
- installed ceiling tile above slop sink
- installed baseboard tile at hand sink and grouted
- installed baseboard tile in walk in on the right and grouted
- replaced three floor tiles and one baseboard tile and grouted behind 10:1 |
| 3129 | Waylon | 05/23/2025 | 21582 | -just helped him with building maintenance
-Welded muffin toaster
-Fixed dt corner coming out |
| 3128 | Jim | 05/23/2025 | 25383 | - repaired wallpaper in vestibule
- re attached trim in vestibule
- replaced threshold on street side exterior door
- re caulked present area floor tiles
- re installed three wall tiles and grouted in ladies room small stall |
| 3126 | Brendan | 05/22/2025 | 11565 | -troubleshooted satellite brewer not heating up. Eventually found the plug was not inserted all the way causing low voltage. Plugged in and tested |
| 3125 | Waylon | 05/22/2025 | 07194 | -Installed new hlz little weird it’s on like a plate heater but I mean what can you do just caught me off guard
-fixed fry station needed new socket new wire terminals and added spacers to stop it from shorting out from the poorly engineered sockets |
| 3124 | Jim | 05/22/2025 | 25383 | - installed new Formica on drink station door in lobby
- re installed metal trim on lobby closet door
- replaced four floor tiles in present area
- attempted to replace sink faucet, pipes in wall are one size larger then the fittings on the new faucet |
| 3123 | Brendan | 05/21/2025 | 00596 | -measured and planned for water upgrades
-troubleshooted frappe issues. Regulator diaphragm deformed, on order. Ordered new co2 inlet fitting for that issue |
| 3122 | Brendan | 05/21/2025 | 25383 | -diagnosed fry vat 3. Not igniting. Parts on order.
-diagnosed window 1 not opening. Root cause: being 23 years old… ordered parts |
| 3121 | Waylon | 05/21/2025 | 00596 | -Installed new freezer bar and curtain and cut curtain to size
-Installed new power cord for hlz and new fuse tested came to temp and was running good |
| 3120 | Waylon | 05/21/2025 | 25383 | -Lot light pole broke 6 drill bits so called top and clamped
-Side of dt building screwed down and caulked edge then caulked top of screws
-Diagnosed had light ballast going to rain tmrw and roofers haven’t came not fixing yet
-Hot water valve by dish sink works perfectly fine |
| 3119 | Waylon | 05/21/2025 | 04956 | -Installed new co2 alarm and crimped connectors and new 3 ways splitter |
| 3118 | Jim | 05/21/2025 | 18364 | - men’s room toilet fastened tight to floor
- pothole at entrance to parking lot repaired
- cleared hand sink drain by fry station
- cleared clog in dish washer drain pan
-foamed hole in wall by delivery door
- removed old detex unit and covered hole
- replaced ceiling tile in crew room
- need 5 corral boards light grey color trex |
| 3117 | Waylon | 05/21/2025 | 17371 | -New light lens
-Fixed vent for hvac duct
-Started to create a lip for the fry station made an outline need proper metal for it and mixed opinions on if worth fixing or buy new or it’s not a problem yet |
| 3116 | Waylon | 05/20/2025 | 17371 | -New co2 alarm central unit sniffer and new wires ran the person who installed Alton’s system didn’t follow code so had to move stuff around
|
| 3115 | Jim | 05/20/2025 | 21582 | - R&R nine(9) floor tiles by registers, coffee, and present areas and grouted
- sent picture of missing hinge cover to kolpak , waiting for pricing
- replaced two floor tiles by multiplex and stock shelves and grouted
- cut and installed new vent cover over rear of present fridge
- adjusted delivery door crash bar to close and latch properly |
| 3114 | Jim | 05/16/2025 | 07417 | - cleared drain and cleaned area |
| 3113 | Waylon | 05/20/2025 | 11565 | -Replaced baseboard tile by fcb
-Sealed wall next to fcb white ground
-Sealed corner by fcb black caulk (lowkey looks bad not my fault though every told from the passed company or construction is cut differently for lengths only way to fix is redo like 10 feet of tile
-back door tile by trash door replaced and grouted had to cut that one |
| 3112 | Brendan | 05/20/2025 | 11565 | -replaced ABS drain pan, sensors, and conveyor motor. Works great now!
-replaced frappe co2 o ring and gave store extras |
| 3111 | Waylon | 05/19/2025 | 21582 | Fry station wire burned off had to pull morning and replace switch and replace socket |
| 3110 | Brendan | 05/19/2025 | 00596 | -ABS, working and in use NTF
-grill platen 2, working and in use NTF
-motor out back working correctly, probably just not used to hearing it since it’s been broken for a while. NTF |
| 3109 | Brendan | 05/19/2025 | 10622 | -new fryer install!!!
-replaced bunn coffee pot board that had a bad transformer |
| 3108 | Waylon | 05/19/2025 | 10622 | -Helped install new fryer and take parts from old
-Helped move the electrical a little cause when we fryer in without changing the plugs it stuck out an extra couple inches
-fixed coffee brewer with Brendan |
| 3107 | Waylon | 05/17/2025 | 36960 | -2 cable pulleys broke on on each platen for emergency call pulled motor harness removed broke installed new on both platters |
| 3106 | Brendan | 05/16/2025 | 02830 | -repaired ABS conveyor not moving, remounted sensor
-fixed KVS 1 speaker not working
-ordered stock shelf clip and kiosk8 controller |
| 3105 | Brendan | 05/16/2025 | 36960 | -replaced coffee brewer cup for faucet
-Taylor part for frappe not in yet unfortunately |
| 3104 | Brendan | 05/16/2025 | 16552 | -dt monitor was unplugged even though I asked her last night to make sure everything was plugged in tight😭 |
| 3103 | Brendan | 05/16/2025 | 00596 | -repaired frappe co2 connector
-programmed fryer computer
-FCB NTF |
| 3102 | Jim | 05/16/2025 | 07417 | - cleared drain and cleaned area |
| 3101 | Jim | 05/16/2025 | 11565 | - snaked drain by oil tank and ran 20 feet, did not clear, let Brendan know and he is contacting east coast
- filled two parking lot potholes |
| 3100 | Jim | 05/16/2025 | 10622 | - cleared drain in left hand men’s urinal
- filled pothole on right hand side or building
- fryer moved in front of multiplex, by Stephanie and Matt in the store |
| 3099 | Waylon | 05/15/2025 | 21582 | HLZ installed new plate heater and new rtd probe since old one was frail and destroyed, all those parts work great hlz is still broken because since we have ancient equipment the wires on the plate heater relay shorted out since it’s bare wire from how old it is and that caused the relay to be stuck on 24:7 causing it to overheat which is awesome last time I was here it wouldn’t heat enough and now it overheats 🥳🥳🥳 |
| 3098 | Brendan | 05/15/2025 | 10544 | -repaired broken frappe water line
-replaced cash drawer pos1 |
| 3097 | Waylon | 05/15/2025 | 04205 | -Hot water heater pouring all over floor replaced pressure relief valve then was having problems lighting back up got that eventually
-Tried to snap drain next to hot water heater snake was just hitting something and not going anywhere told store to call east coast
-Adjusted thermostats since half were in heat still and went on roof to check units found 2 to be not running / not running up to par called Rick and gonna have him take care of it |
| 3093 | Brendan | 05/15/2025 | 02038 | -replaced Zoom time CU |
| 3092 | Jim | 05/15/2025 | 11565 | -installed five wall tiles by slop sink and grouted plus grouted floor in front of slop sink
- filled multiple holes by time clock and office
- replaced sink faucet
- re glued lobby baseboard by pick up window
- fills small pot hole by corral |
| 3091 | Waylon | 05/15/2025 | 18198 | -Office door stopper sourced
-Fry station NTF
-Libny shade gear and chain |
| 3090 | Jim | 05/15/2025 | 16552 | - cleaned drain under slushie machine
- replaced two belts on bun toaster |
| 3089 | Waylon | 05/14/2025 | 00596 | -Installed new fish button read multiple manuals couldn’t program
-Welded fry station wasn’t amazingly pretty but had to give it back for dinner made it safe of any surfaces people can slice their hands on
-HLZ off was a blown fuse dived in further to make sure latch relay heat relay air relay all functioning properly and came up to temp
-Installed new freezer lock cut off old and replaced all freezer lock screws
-Installed cabinet locks for office for uniforms so employs would stop taking them gave laurel 2 sets of keys for them
Did measurements for the prep fridge they wanna swap out won’t fit without relocating a single and tea brewer notified Tara regarding the matter
-Plug hanging out of wall literally just needed to be pushed in slightly tilted only because the cord weights so much and the outlet is in like the middle of the wall
|
| 3088 | Jim | 05/14/2025 | 21582 | - ground down curbing that was chipped in front of building and sidewalk side
- epoxied broken curb by sidewalk
- re installed kiosk disc at ceiling
- replaced two floor tiles on side two |
| 3087 | Brendan | 05/14/2025 | 16552 | -replaced 7 lobby soda valves, brixed and portioned
-replaced lemonade button panel and calibrated portion |
| 3086 | Jim | 05/14/2025 | 21582 | - installed repaired drain in ABS and reconnected drain line
- installed new exit sign above trash door |
| 3085 | Brendan | 05/14/2025 | 11565 | -repaired leaky co2 line frappe machine
-adjusted sensor at FC ABS but after realized the motor was loose and fell out of place. Removed the motor and found the screw holes rusted out. Will need to order drain pan to repair |
| 3084 | Jim | 05/14/2025 | 10544 | - replaced four batteries on hand sink unit
- cleared obstruction on hinge side of delivery door, closes and latches now
- fixed water leak on hose for smoothie machine |
| 3082 | Brendan | 05/13/2025 | 00596 | -car drove through the building!!!!!!!
-managed to get soda up and running |
| 3081 | Brendan | 05/13/2025 | 16552 | -replaced ped15 |
| 3080 | Jim | 05/13/2025 | 21582 | - replaced six floor tile by office |
| 3079 | Waylon | 05/13/2025 | 25383 | -Welded a fry hopper piece
-Installed new ballast for light
-Installed 3 new cabinet strips |
| 3078 | Brendan | 05/13/2025 | 02038 | -RHS not online, somehow network came unplugged
-replace ring jet nozzle for espresso machine |
| 3077 | Brendan | 05/13/2025 | 21582 | -replaced ped15 |
| 3076 | Jim | 05/13/2025 | 04205 | - repaired ABS drain
- R&R ladies room lg toilet spud , no leaks
- ordered new exit sign above trash door, will be in tomorrow |
| 3075 | Brendan | 05/13/2025 | 10622 | -worked on finding old circuits to make room for electric fryers |
| 3074 | Waylon | 05/13/2025 | 10622 | -went through breaker panels making room for electrician cutting out old unused crap
|
| 3073 | Jim | 05/13/2025 | 18198 | - cleared both toilets in ladies room |
| 3072 | Waylon | 05/12/2025 | 25383 | Corral project |
| 3071 | Jim | 05/12/2025 | 25383 | - worked on corral |
| 3070 | Brendan | 05/12/2025 | 00596 | -replaced booster pump and check valve
-replaced frappe o rings and co2 QDC again
-replaced Dr Pepper nozzle that was leaking |
| 3069 | Brendan | 05/09/2025 | 07417 | -finished replacing drain pan, superseal, motor, and sensors |
| 3068 | Brendan | 05/09/2025 | 02038 | -replace grill 4 broken spring |
| 3067 | Brendan | 05/09/2025 | 16552 | -replaced parts for frappe machine, rinses great now. Had to update software as well because it did not work with chocolate chip frappe. Also replaces the flavor nozzles upon request
|
| 3066 | Brendan | 05/09/2025 | 11565 | -troubleshooted co2 leak. Found frappe machine leaking from a split hose, repaired. Also noticed frappe pumps running for valves not used, turned valves off.
-went to replace flat washer on dish sink diverter but it uses an unusual type of cartridge. Will order replacement unit
-troubleshooted FC ABS. Sensor not installed properly. Will fix next week |
| 3065 | Waylon | 05/09/2025 | 25383 | -Installed and had to create a new securing function for the cabinet board working and up to temp
-installed new motor in window working
-
|
| 3064 | Jim | 05/09/2025 | 21582 | - removed old cup holder and made and installed new cover plate |
| 3063 | Brendan | 05/09/2025 | 07417 | -worked on replacing ABS motor/drain pan. I was able to get the drain pan screws drilled out, but not successful on the motor. Waylon will be coming by with more powerful tools to try |
| 3062 | Brendan | 05/08/2025 | 10544 | -troubleshooted ABS making drinks one drink off. Updated software just in case. Noticed 3 broken cup holders which I will order, but I believe the issue is the large amounts of ice in the drain pan causing the cup to not be read by the sensor
-breakfast cabinet issue was that the water line was not plugged in nor turned on
-handwash sink showed how to open the battery compartment |
| 3061 | Jim | 05/09/2025 | 11565 | - filled and packed down pot hole by drive thru |
| 3060 | Jim | 05/09/2025 | 10544 | - sourced and replaced spray handle , hose ,and spring
|
| 3059 | Waylon | 05/08/2025 | 25383 | -Walked in to see the cabinet I looked at yesterday to be off and then not using it which was weird I asked them about it found out they were using it all the way till close and then it stopped working diagnosed bad power supply board which is what I was looking into yesterday but it started working receiving 208 into it not giving the 5 volts it should part is ordered
-Diagnosed both windows for bad motors
-Repalced 4 tiles outback slightly concerned regarding how long it took for them to even start to set but left a blower fan to run on them all day
-Diagnosed monitor receiving power not working needs new
|
| 3058 | Jim | 05/08/2025 | 11565 | - partially filled pot hole by drive thru only had 2 1/2 buckets
Needs one or two more
|
| 3057 | Jim | 05/08/2025 | 16552 | -cleared drain clog in hand sink
- ABS ice machine won’t make ice unable to figure it out
Shut off and turned it back on
And reset to factory settings
No result |
| 3056 | Jim | 05/08/2025 | 04956 | - cleared clog in right hand ladies room sink
- grouted floor areas
- cleared out ice buildup on CO 2 tank and switched to back up tanks
- used Bluetooth speaker for lobby music
- installed new leg on lobby Bench
- swapped high chairs with Epping |
| 3055 | Waylon | 05/07/2025 | 04956 | Took eppings bump bar for tempering swapped with Raymond’s broken
Installed the rest of co2 link |
| 3054 | Waylon | 05/07/2025 | 25383 | -Replaced office printer
-Fixed grill platen 4 tripped breaker
-1 hour later platen 4 top was at 582 degrees set point 425 replaced relay working
-Cabinet not turning on traced through cabinet from transformer board loose connection
-Replaced 1 cabinet strip ordering more need 3 |
| 3053 | Brendan | 05/07/2025 | 18364 | -troubleshooted parking lot lights not working. Timer froze, reset and now works |
| 3052 | Jim | 05/07/2025 | 04956 | - installed light bulb and glass cover in freezer
- shortened wire on door side light in freezer
- made cover for electrical box in freezer
- sourced and replaced backflow preventer in slop sink
- sourced and replaced left hand sink hand free faucet in ladies room
- sourced and replaced mixing valve in left hand sink in ladies room |
| 3051 | Waylon | 05/07/2025 | 04956 | -Worked in freezer on electrical and lights
-Diagnosed with Jim bad mixer valve in women’s room
-Still need another part for water back flow Jim is taking to fw Webb to get the rest of the fittings no local store has |
| 3050 | Jim | 05/07/2025 | 21582 | 1 cut wall behind washer open to see if drain pipes were leaking, found pvc to steel into floor. Steel pipe at floor has some rust.
Ran snake in clean out about ten feet and pulled clog out.
Dried completely around affected area and ran wash cycle.
No water now !!!! Made diamond plate access panel.
|
| 3049 | Brendan | 05/06/2025 | 18364 | -tablet set up |
| 3048 | Brendan | 05/06/2025 | 16552 | -troubleshooted lobby soda station issues. I was troubleshooting the carb system because literally none of the soda there worked. I eventually found the carb unit was working fine but every single valve was sticky. got them loosened up but will order a new set just in case
-MTP conversion
-troubleshooted water pressure issue at frappe machine. adjusted up regulator all the way but also dont trust it so ordering a new one since the gauge is broken anyway. Nozzle is also stiff so it doesnt spin, on order as well |
| 3047 | Waylon | 05/06/2025 | 04956 | -Co2 coupler installed new none of the alarms lit up had to rerun new main line the old one got caught on a sharp piece of ceiling grid and cut it then found another part broken was the 3 way connector coupler it gave power to everything but wouldn’t tell the alarms to go off so ordered new coupler from Amazon will be here tmrw
-Water check valve leaking on mop sink need to rebuild a new one still had to screw old back on so store can make mop buckets tonight
-Installed new freezer curtain
-Installed 4 new cabinet wheels
-Went to try and fix electrical wire in freezer hanging loose need to wait for Jim to bring the new light and see if we need to fix old or if I can abandon it
Fixed filter leaking all over floor needed new o rings and lube
-Helped Jim with diagnosis on women’s bathroom in what to do he said the battery was the problem after walking through two test with him so ordered two new ones
|
| 3046 | Brendan | 05/06/2025 | 36960 | -repaired frappe machine. Needed new regulator and I flogged drain pan. Need to order sd card for new frappe |
| 3045 | Jim | 05/06/2025 | 00596 | - snaked floor drain, hit a hard blockage, store called east coast
- wire tied drain cup to hold in place , it kept falling over, all set now |
| 3044 | Jim | 05/06/2025 | 04956 | - painted ladies room large stall ceiling
- adjusted walk in door to close better
- ordered light cover for freezer will pick up Wednesday and install Thursday AM
- added diamond plate to bottom of freezer by hot water tank
- troubleshooted ladies room large flush control , Waylon ordered new battery, will install Thursday AM |
| 3043 | Waylon | 05/05/2025 | 04956 | -dt window latch fixed
-Co2 alarm sniffer moved need to come back tmrw with a coupling for the Ethernet lines |
| 3042 | Jim | 05/05/2025 | 04956 | - replaced and grouted 7 floor tiles around kitchen and stock room
- picked up paint for ladies room ceiling
- installed new seal on site shot machine
|
| 3041 | Jim | 05/05/2025 | 02038 | - installed bar seal on ice bin that fell off
- waited for contractor to come and repair stock room shelves |
| 3040 | Waylon | 05/05/2025 | 07194 | -New door window latch for first window snapped my rivet nut bit off so had to drill that out and redo with a smaller bit sadly
-Hlz went in to replace air heater found the main reason was maple syrup or some type of syrup had been spilled all over it basically gave a death sentence I spent a good amount of time trying to scrape it scrub it and used goo gone then was hoping it was enough put new air heater in instantly began to smoke so ordering new and scrapped for parts |
| 3039 | Waylon | 05/05/2025 | 18198 | Lees abs grout under for worms
Reset cod |
| 3038 | Jim | 05/05/2025 | 10622 | - re set rear delivery door crash bar |
| 3037 | Brendan | 05/02/2025 | 07417 | -replaced coke tank pressure relief that blew
-replaced Dr Pepper valve on left |
| 3036 | Brendan | 05/02/2025 | 00596 | -repaired ABS with the broken thru beam sensor
-replaced pos1 that was used for a swap
-replaced oven fan motor |
| 3035 | Brendan | 05/02/2025 | 04956 | -music working on arrival NTF
-co2 not iced up anymore
-replaced interface board on middle grill frypot, all set. |
| 3034 | Jim | 05/02/2025 | 04956 | - replaced 17 floor tiles and grouted
Still need to cut and replace five more but my grout cutting tool broke |
| 3033 | Brendan | 05/01/2025 | 04956 | -replaced two kitchen bump bars
-dt window works fine people just keep pressing buttons they aren’t supposed to🤬
-removed screws causing COD cladding to rattle
-troubleshooted fry vat 4. Checked contactors which checked out ok. Tested hi limit which checked out ok. Found the heat relay on the interface board was intermittently functioning. I could lightly tap the relay to get it to turn on. New board on order |
| 3032 | Brendan | 05/01/2025 | 07194 | -MTP transition
-replaced pos13 cash drawer cable and also properly fastened to the shelf so it would stop sliding around |
| 3031 | Jim | 05/01/2025 | 25383 | - worked on corral, replaced all damaged frame pieces, stripped the rest of the old boards, worked with Waylon to big in installing new boards |
| 3030 | Waylon | 05/01/2025 | 25383 | -Work on corral had to spend a long time cutting board doing more frame work on pieces that broke in the process of putting new boards on but got a little bit of new boards on |
| 3029 | Brendan | 04/30/2025 | 02038 | -zoom timer working fine, and times are consistent with OEPE on POS. NTF
-troubleshooted hot milk issues melitta. Ring jet nozzle cracked and leaking causing air to get sucked in. On order |
| 3028 | Waylon | 04/30/2025 | 12272 | This was absolutely miserable and more work then expected, lobby soda back draining into the lobby went under was getting stuck at the p trap from the first look pulled that off deep cleaned covered in mold and mold blankets clogging it all up reinstalled that tested still a problem had to then pull the whole pump disconnect the lines going in pull the pump and deep clean all of that which took forever with the amount of mold covering everything then had to rebook up ended up leaking from one of the fittings had to cut out one of the lines to tighten that fitting and put a new adjustable coupling on the cut line so the next person doesn’t have to cut any pvc |
| 3027 | Jim | 04/30/2025 | 25383 | - cut and replaced wall tile on menu board wall and grouted
- cleared urinal drain that was running slow |
| 3026 | Waylon | 04/30/2025 | 02830 | -Fry vat 2 plug ended up stripping back the cord a lot more the burnt wires were excessive had to cut out the old plug since the wire screws were burned and replaced with new tested contactor received 208 between all legs turned on waited to come up to temp
|
| 3025 | Waylon | 04/30/2025 | 04956 | -Wall freezer not coming down to temp it’s a newer one meaning it’s R290 I don’t have the equipment to work on a R290 system or the proper gauges to make it easier granted cause use a chart and convert it all over, my diagnosis is low on charge the system is less than a year old I believe has no accesss ports and I don’t have any R290’or a rack to even put it on so outsourcing |
| 3024 | Jim | 04/30/2025 | 10622 | - Replaced drain pipe, gasket, and collar on prep sink
- filled new power washer with oil
- epoxied men’s room toilet
- removed delivery door latch cover , missing screw caused door to stick |
| 3023 | Jim | 04/29/2025 | 02830 | - helped transfer freezer products to temp trailer and brought overflow to Hanover street |
| 3022 | Jim | 04/29/2025 | 04956 | - replaced 10 floor tiles in front of grills and fryers and grouted |
| 3021 | Waylon | 04/28/2025 | 10622 | Diagnosed old pressure washer believe I can fix for about 100$ gotta finish grabbing part numbers and order
Bought new pressure washer so they could have for their RGR and built it they just had to add oil and gas
-installed new bun toaster cord |
| 3020 | Jim | 04/28/2025 | 21582 | - adjusted trash door latch, door closes fine now |
| 3019 | Jim | 04/28/2025 | 04956 | - replaced 53 damaged tiles in front of sink and grouted |
| 3018 | Waylon | 04/28/2025 | 17371 | -Co2 alarm going off didn’t find any co2 leak tank is not frosted up went off before I got there ppm is down to normal range double checked wiring in co2 tried check altitude didn’t work so more worry about faulty sniffer but not enough clear evidence to say it’s bad NTF
|
| 3017 | Jim | 04/25/2025 | 21582 | - cut out two broken studs on welcome sign, re welded two new studs and re leveled sign |
| 3016 | Jim | 04/25/2025 | 25383 | - replaced men’s room changing station in men’s room
- replaced bathroom side vestibule ceiling tile
- re set drive thru clearance bar
- mixed and poured concrete for five corral posts
|
| 3015 | Waylon | 04/24/2025 | 17371 | -Had to source new PED for back cash not accepting cards |
| 3014 | Jim | 04/24/2025 | 25383 | - worked with Waylon to repair corral, delivery truck caused extensive damage, repair ongoing |
| 3013 | Waylon | 04/24/2025 | 25383 | -Worked with Jim on corral had to dig out the whole back of the corral and had to cut down trees to even get to it then all the ground had tree roots running through it had to saw it all off demoed back board of corral set up concrete footing finished 2 of them welded rebar to poles where Martin brower truck hit and drilled into concrete pad for rebar installed rebar on all the other footings
|
| 3012 | Waylon | 04/23/2025 | 02830 | -Doagnose fryer missing 129 volt leg found burnt plug ordered new |
| 3011 | Waylon | 04/23/2025 | 21582 | -HLZ so found out why it kept blowing fuses no screws in the bottom so when people would lean against it would instantly short and trip once I plugged it and it tried beating up noticed one was heating very slowly or not at all so took it apart again begin testing plate heater found it missing half the resistance amount it should be relay was working properly and latch relay properly bad heater plate |
| 3010 | Waylon | 04/23/2025 | 00596 | Installed multiplex capacitors had to rewire half the box from multiple daisy links
Cleaned multiplex condenser coil
|
| 3009 | Waylon | 04/23/2025 | 10622 | -Curtis coffee brewer parts installed new solenoid new board new spray head and programmed
-Filet steamer OEP replaced
-Pressure washer won’t start got it to start and ran for 20 minutes to get gas and oil flowing again
-Ice machine in lobby leaking took off cover found a constant drink under ice bin originally thought ice bin crack but it was a constant flow of water checked ice machine for a water reservoir crack no problem there ended up finding clogged drain hose in the drain cleared that and stopped the leaking |
| 3008 | Jim | 04/23/2025 | 17371 | - repaired fence pieces
- straightened out the door frame and re mounted the door closer on delivery door |
| 3007 | Waylon | 04/23/2025 | 04956 | -Call for creamer not working joins arrival found creamer and milk both off went to check voltage received none went to breaker panel found tripped breaker but stuck in on position so they would’ve never noticed it reset and working
-Installed new filet steamer oep |
| 3006 | Waylon | 04/22/2025 | 18198 | -Went to install new dt2 printer was working when I got there and printing
-was told abs drain clogged had to pull that undo clamps and pull line found what looked like a shit Tom of cat food in the line but smelled very pepper like anyways pulled and broke the clog in line then washed out tested and re tied up line |
| 3005 | Waylon | 04/22/2025 | 04205 | -Installed new washer latch switch
-Installed new muffin toaster cord and OeP zip tied the cord in instead of drilling a new hole and spending more money on a anchient muffin toaster surprised I’m still working on it
-Installed new display board into cabinet
-other cabinet item for strips on the list was lit up and working fine no trouble found |
| 3004 | Waylon | 04/22/2025 | 00596 | Pos 14 decided to die so swapped with pos 1 for the time being |
| 3003 | Waylon | 04/22/2025 | 07194 | -Cabinet turned off pretty sure when we ordered switches they sent us a bad batch cause this is the 3rd one to break within a month but they are cheap trash replaced switch and installed new fan
-Diagnosed HLZ air heater burned to a crisp causing burning smoke
-grill fryer installed both contractors and a new transformer tested came up to temp instructed manager (Kyle) to empty out the old oil put in new and they will be good
-Went around lot and spray foamed lot lights letting it sit so it fully cures and then will have to go back at some point to cut off the extra foam and make it look proper |
| 3002 | Waylon | 04/22/2025 | 25383 | Installed new grill button
Looked at shake machine vanilla syrup side couldn’t find any lube anywhere in the store so notified Sara that they just need to lube it |
| 3000 | Jim | 04/22/2025 | 04956 | - sourced and installed stainless plate over opening in front cabinet
- replaced lobby ceiling tile above registers
- took broken fridge to swap with one from Milford and returned Milford’s old unit to Raymond |
| 3001 | Waylon | 04/22/2025 | 10544 | -Same thing as yesterday cup arm screw came out how I’m not sure but hand tightened to the max i can do if it happens again gonna use loctite on it but preferably not since that screw will never be coming out in that case |
| 2999 | Waylon | 04/21/2025 | 04205 | Was installing capacitors for multiplex one came faulty was oozing liquid out of the top of it…. |
| 2998 | Jim | 04/21/2025 | 04956 | -installed new monitor bracket on chase by old egg cooker
- installed screws to secure diamond plate under freezer door |
| 2997 | Waylon | 04/21/2025 | 02038 | Grill platen 2 not working found broken belt and home switch loose tightened and replaced belt
-Prep fridge again worked for a week and something internally in the compressor went made sure with one of Rick’s guys since I thought it was crazy for that to happen a week after a new one |
| 2996 | Jim | 04/21/2025 | 02830 |
-Repaired drive thru curbing |
| 2995 | Jim | 04/21/2025 | 00596 | a- sourced and replaced electronic flush control for men’s room urinal |
| 2994 | Waylon | 04/21/2025 | 10544 | ABs cylinder arm not moving ended up being an Allen screw that fell off the cylinder connecting it to the arm took apart reinstalled tested all set |
| 2993 | Jim | 04/21/2025 | 12272 | - went to replace sanitizer sink seal and there was no issue
|
| 2992 | Waylon | 04/21/2025 | 07417 | Looked into lobby soda leaking can’t find anything especially since if there was a broken line it would be going everywhere ran and tests all the sodas no leak cleaned it up and disabled Dr Pepper found a small leak of soda water going down the handle but nothing massive most likely needs a new oring for it but Brendan was already planning on ordering parts for it since the syrup side gets stuck on sometimes |
| 2991 | Waylon | 04/21/2025 | 18198 | -New frappe water line o ring installed |
| 2990 | Waylon | 04/20/2025 | 04205 | Went to replace frappe water line so they can sell coffee tomorrow morning and frappe |
| 2989 | Brendan | 04/18/2025 | 10622 | -mtp transition |
| 2988 | Brendan | 04/18/2025 | 18198 | -printer 15 being really stubborn. Got lazy and just reimaged it which will hopefully fix |
| 2987 | Jim | 04/18/2025 | 00596 | - made stand for lobby drain pipe the restrict movement |
| 2986 | Jim | 04/18/2025 | 07417 | - re mounted men’s room toilet dispenser |
| 2985 | Jim | 04/18/2025 | 00596 | - replaced sink faucet completely
- ran new hot and cold lines, (mixed ) to sink soap dispensers. And added separate shut off |
| 2984 | Brendan | 04/17/2025 | 07417 | -replaced middle grill vat computer that had bad temp button. Programmed chicken strips, also noticed programming was off on other vats for assorted items so I corrected all vats and all items to current McD standards |
| 2983 | Brendan | 04/17/2025 | 10622 | -repaired tea brewer. The inside of the tank was all black sludge and even the probes were so sludgy. Cleaned out the tank real good and the probes, replaced the element and all better
-diagnosed Curtis coffee brewer. Brew solenoid went bad and killed the board. Ordered the board and solenoid, the sprayhead fitting and sprayhead because its really crusty and loose, and also a piece of tubing just in case it breaks when changing the solenoid |
| 2982 | Waylon | 04/17/2025 | 02830 | Installed new correct pie merchandiser parts
-Semi fixed shake machine plug they literally tore it out of the wall so screwed it in kinda rigged something up not the prettiest work but realistically needs to all be redone if they stop ripping a plug out of the wall 😭😭😭 |
| 2981 | Brendan | 04/17/2025 | 02830 | -mtp transition |
| 2980 | Jim | 04/17/2025 | 10544 | -installed new door handle on vestibule door
- got list of materials for fence repair |
| 2979 | Brendan | 04/17/2025 | 04205 | -troubleshooted multiplex. At first I thought was a bad compressor but I kept looking just in case and found both start and run caps bad. Will order the caps and hope the compressor ends up working. Also noticed primary carb motor seized, will also replace |
| 2978 | Brendan | 04/17/2025 | 04956 | -mtp transition
-installed printer bumpers and gave new door keys |
| 2977 | Waylon | 04/17/2025 | 07194 | Installed new transformer for grill vat turned on and still was having problems traced to contractor which bottom side was charred up ended up finding a short which was causing the transformer to short out so needs new transformer and contractors |
| 2976 | Jim | 04/17/2025 | 00596 | - wire tied lobby soda drain lines to stay aligned with drain cup
- replaced sink spray hose, old hose was actively leaking at top connection
|
| 2975 | Jim | 04/17/2025 | 07194 | - sourced and replaced fence post
- applied skim coat on delivery door sidewalk |
| 2974 | Waylon | 04/17/2025 | 04956 | -Chill rail which I was here for yesterday they sent a photo two hours I left of the screen blank so went back checked power didn’t have that plugged in after finding plug loose kicked right on then waited with it to come down to temp was at 40 when I left se point 35 so should keep going down |
| 2973 | Brendan | 04/16/2025 | 04956 | -found co2 leak under ABS, replaced fitting
-fixed dt window not opening, someone pressed the opening size button again
-disable heat plates left brewer |
| 2972 | Brendan | 04/16/2025 | 04205 | -mtp conversion |
| 2971 | Waylon | 04/16/2025 | 21582 | -Emergency call for two grills down for there only one platen was down the other is intermittent so not bothering with it the one that was down has a dirty flame igniter pulled out cleaned lit up it looks pretty rough so ordering a new one not sure how long just cleaning it will last |
| 2970 | Brendan | 04/16/2025 | 25383 | -replaced muffin toaster relay
-swapped out broken FFLS |
| 2969 | Waylon | 04/16/2025 | 04956 | Installed new condenser fan in chill rail had to unmount from the chill rail took Mike and I both to lift it back on so that was cool
Cleaned around old fan
Programmed new chicken strips in vats for them |
| 2968 | Jim | 04/16/2025 | 21582 | -filled holes in wall side two
- caulked by walk in door
- filled holes in walk in and freezer walls
- holes in delivery door filled
-four holes filled to left of delivery door
-trash door latch needed to be re-set
- installed new left hand weatherstripping on trash door
- c ill earned trash door threshold area to allow proper operation of door |
| 2967 | Waylon | 04/16/2025 | 17371 | -Installed new vat 3 AIF probe
-welder 2 grill brackets 4 welds total
-went around building with ty and counted siding to be replaced around 29 boards |
| 2966 | Brendan | 04/16/2025 | 10544 | -mtp transition
-replaced ABS ice gate
-replaced dogging by mech |
| 2965 | Jim | 04/16/2025 | 04956 | - cut and installed cover for old light switch in walk in
- applied diamond plate to left hand side of slop sink
- cut and applied diamond plate under freezer step
- cut and replaced two baseboard tiles by delivery door and grouted |
| 2964 | Brendan | 04/16/2025 | 12272 | -troubleshooted hot water. Bad flame rod, called Rick
-mdm transfer |
| 2963 | Brendan | 04/15/2025 | 10622 | -troubleshooted tea brewer, bad element. On order |
| 2962 | Waylon | 04/15/2025 | 02038 | -What a ficking day replaced compressor in salad fridge had to deal with the whole reclaim then vacuum then pull compressor out and wires cut old pipes off install new braze like 15 fucking stupid fittings using a 1000 degree torch in tight spaces do not recommend had to source new pipe new filter drier pipe bender and heat resistant putty finally got all that done charged unit with recommended 9.5 ounces wasn’t cooling added more charge ended up over charging unit anyways it’s fixed long day much bullshit live laugh love refrigeration would’ve been nice to go to a class for refrigerations and not AC units 💀 |
| 2961 | Jim | 04/14/2025 | 25383 | - replaced four floor tiles by delivery door
- cut and replaced vestibule ceiling tile
|
| 2960 | Waylon | 04/14/2025 | 07194 | -Qing oven main fuse blew tested 6 times worked all set
-Fry vat no power needs a new transformer thought Hanovers old fryer had one went scrapped it for parts found out gas and electric had a different type which is crazy for no reason
-Dishwasher plug swapped out tested and ran |
| 2959 | Brendan | 04/14/2025 | 00596 | -ABS grabbing many large cups, store solved before I arrived. NTF |
| 2958 | Brendan | 04/14/2025 | 04205 | -espresso machine water was off… again…….
-frappe was working fine, probably was unplugged when they added to list. NTF… |
| 2957 | Waylon | 04/11/2025 | 25383 | -Diagnosed muffin toaster one leg of relay wasn’t pulling 7 amps checked all legs to make sure wasn’t a burnt up connection ordered new relay |
| 2956 | Waylon | 04/11/2025 | 07194 | - walked lots and talked with electrician and diagnosis
- took fan out of UHC to try and find locally sourced
- had general manager call eco lab for tripping dish washer
|
| 2955 | Jim | 04/11/2025 | 21582 | - tightened diversion railing
- cut and installed new ceiling tile in vestibule
- installed new ceiling grid pieces and two new ceiling tiles above stock shelves
- cut and replaced 2x2 light lens above drive thru one
- regaled faux wood on bottom of McCafe wall |
| 2954 | Brendan | 04/11/2025 | 07194 | -met electrician for lot lights |
| 2953 | Jim | 04/11/2025 | 00596 | - assembled new stock shelf to replace coke tanks
- broke down a large pallet and trashed it |
| 2952 | Brendan | 04/10/2025 | 04205 | -printer upgrades. Had to run a new line again because one of the new ones was defective |
| 2951 | Waylon | 04/10/2025 | 10544 | -Chicken vat oil stuck open cleared metal from pipe
-Libby shade chain only found one stuck down asked manager and they said only that one is the problem fixed
-door not closing on cup storage needed to be hammered back into place all set might need to be welded in the future for a whole new hinge |
| 2950 | Brendan | 04/10/2025 | 21582 | -new fryer install |
| 2949 | Jim | 04/10/2025 | 04205 | - upon arrival was asked if I could fix water issue by multiplex, found ice bin drain pipe had shifted out of floor drain, re set
- filled numerous potholes in parking lot |
| 2948 | Waylon | 04/10/2025 | 21582 | -Helped Brendan install new dryer
Hlz not working blown fuse |
| 2947 | Jim | 04/10/2025 | 00596 | - filled potholes in parking lot |
| 2946 | Waylon | 04/09/2025 | 07194 | -Diagnosed lot breaker trip instantly went to poles undid wires still tripled tested breaker without wires worked fine so it’s getting shorted somewhere need electrician
-Isntalled new cabinet switch found a bad fan in it while installing new switch |
| 2945 | Jim | 04/09/2025 | 04205 | - partially filled one pothole with the last of my driveway patch |
| 2944 | Jim | 04/09/2025 | 07194 | - cleaned out and filled with concrete, hole in delivery sidewalk |
| 2943 | Brendan | 04/09/2025 | 10622 | -finished up repairing co2 leaks, rebuilt two regulators in frappe machine that came in |
| 2942 | Waylon | 04/09/2025 | 21582 | -left grill platen 2 not coming to temp gas burner was not heating properly due to it not even being on had a lose flame igniter after I checked everything else 😑
-Filled grout into a tile edge that was missed |
| 2941 | Jim | 04/09/2025 | 10544 | -filled potholes around parking lot |
| 2940 | Brendan | 04/09/2025 | 02830 | -frappe refrigeration training with Doug🎉 |
| 2939 | Brendan | 04/08/2025 | 04956 | -replaced pie warmer switch |
| 2938 | Jim | 04/08/2025 | 21582 | - replaced 4 floor tiles by coke tanks and sink , grouted all
|
| 2935 | Jim | 04/08/2025 | 04956 | - poured drain cleaner in 1st men’s room urinal
- cut out and installed new floor tiles and grouted by grills and vats (11)
- tightened men’s room partition |
| 2937 | Brendan | 04/08/2025 | 02830 | -troubleshooted frappe dispense head with Waylon - we were unable to get service ports working so called into Taylor, we well learn from them when they get there.
-troubleshooted pie merchandiser again, the model number on the sticker was incorrect so the parts ordered was for the wrong model… correct ones on order |
| 2936 | Waylon | 04/08/2025 | 25383 | -looked into FCB barrel freezing intermittent ordering new solenoids for it
-Charged shake machine
|
| 2934 | Brendan | 04/08/2025 | 25383 | -learning refrigeration with Waylon. Checked FCB cherry issues. Think it’s a sticky solenoid. Will order. Added gas to shake machine.
-troubleshooted ABS coke. Bad flow control. Replaced all set.
-crimped BNC on merge monitor line
|
| 2933 | Jim | 04/03/2025 | 04205 | Checked washer, changed left knob setting to regular and taped knob
Ran wash and it went thru cycle
Told Lynn if issue come back to put on list for replacement |
| 2932 | Waylon | 04/07/2025 | 02830 | -pie merchandiser
-cleaned fan motor blade
-installed new heating element
-installed new main board
-installed new temp probe
-Abs sensor adjusted and tested
|
| 2931 | Waylon | 04/07/2025 | 18198 | -Installed 2 new lobby shade chains
-Installed new filet steamer touch panel
-Put 2 screws in to hold bump bar for bakery eproduction monitor |
| 2930 | Brendan | 04/06/2025 | 07417 | emergency call fry station down. Switch replaced |
| 2929 | Jim | 04/03/2025 | 04205 | Checked washer, changed left knob setting to regular and taped knob
Ran wash and it went thru cycle
Told Lynn if issue come back to put on list for replacement |
| 2928 | Jim | 04/03/2025 | 10622 | - replaced sink spray line spring and hook ( corroded) also replaced mounting plate with set screws to hold assembly to wall
- removed ladies room left sink faucet control unit,
Disassembled and cleaned filter screens and pump impeller ( heavy coating of iron sediment) re assembled and re installed control unit
Good water pressure now |
| 2927 | Brendan | 04/02/2025 | 07194 | -replaced line for rootbeer in ceiling
-troubleshooted lot lights, believe a mouse got in the conduits |
| 2926 | Jim | 04/02/2025 | 12272 | - installed and adjusted walk in door closer, closes but slowly
- installed screw in left hand grill back plate
|
| 2925 | Jim | 04/02/2025 | 25383 | - unboxed assembled tech rack left it by the stock racks
- re set number one drive thru clearance bar
- installed new light lens in office lite |
| 2924 | Brendan | 04/01/2025 | 02830 | -replaced ABS index sensor and thru beam sensors |
| 2923 | Jim | 04/01/2025 | 00596 | - removed slat shades from lobby windows |
| 2922 | Waylon | 04/01/2025 | 17371 | -Grill PM with Jim had to gap and calibrate
-Installed new freezer cord and replaced burned up outlet how to swap plugs the first time around cause the new plug was too big |
| 2921 | Jim | 04/01/2025 | 17371 | - worked with Waylon to PM grill 1&2 |
| 2920 | Brendan | 03/31/2025 | 21582 | -troubleshooted FCB, unplugged and plugged back in and it worked. not sure why it thought the voltage was low, I tested out of the wall and out of the BNB but all was good.
-replaced breakfast side 1 monitor |
| 2919 | Waylon | 03/31/2025 | 02830 | -Installed new qing oven door, new switch, and new fuse had to rivet the handle on to new and tested working and running
-Diagnosed pie merchandiser bad main board and temp probe 15 degree difference beginning to be faulty and heating element screw snapped terminal off so ordered all of those |
| 2918 | Jim | 03/31/2025 | 10622 | —caulked sink backsplash and replaced GFCI outlet in wall
- grouted base tile and floor tile by frappe machine |
| 2917 | Brendan | 03/31/2025 | 18198 | -ABS not making drinks automatically, plug fell put |
| 2916 | Brendan | 03/31/2025 | 10622 | - replaced booster pump water lines that blew off
- spliced strawberry syrup line
- troubleshooted co2 leak, found a leak at frappe from regulator. Rebuilt two then ran out. On order |
| 2915 | Jim | 03/31/2025 | 00596 | - sourced and installed new battery backup for emergency list
Operate fine now |
| 2914 | Jim | 03/31/2025 | 00596 | - filled exterior freezer door bottom hinge hole with epoxy and reinstalled new screws
|
| 2913 | Brendan | 03/29/2025 | 10544 | -ABS not making soda water, bad CW1 solenoid. Replaced all set. Noticed ice gate incredibly slow. On order |
| 2912 | Brendan | 03/28/2025 | 00596 | -troubleshooted coffee brewer. Kept heating the water so it would boil and spray water out the overflow. Thought oh okay probably a bad probe or relay. But nooooo. I checked amp draw from the relay and it was 0, but still heating…. So I was like ummmmm ok this is weird. So I check amp draw at the power input and get 15amps and I’m like ummmmm this is even more confusing because the other end of the element is at the relay which is drawing 0. So I start to think something has to be grounded because it needs to be getting another leg somewhere. So turns out one of the elements was slightly grounded. By like 15ohm. So not enough to trip the breaker, but enough for it to power the element constantly. Coffee brewer is unapproved obsolete ones, not worth changing out elements.New Axiom on order |
| 2911 | Brendan | 03/28/2025 | 02830 | -coke leaking majorly from FCB. bad expansion tank but of course it’s the middle one which is a massive pain. Fixed that, extended middle tank co2 line, cleaned out regulator, all set.
-replaced Dr Pepper valve with touchless kit |
| 2910 | Jim | 03/28/2025 | 10622 | — finished diamond plate on sink for backsplash
- replaced three baseboard tiles and grouted by sink
- cut and replaced lite lens above ice bin |
| 2909 | Brendan | 03/27/2025 | 02038 | -checked out zoom timer issues. Looks like the pullout time was set way too low at 45 seconds so it though cars kept pulling out of line. Adjusted to 3min will keep an eye to see if that helps |
| 2908 | Jim | 03/27/2025 | 10622 | - prepped wall and installed two diamond plate panels behind sink |
| 2907 | Jim | 03/27/2025 | 21582 | - cleaned and applied caulking to frappe side wall at corner transition
- grouted baseboard tiles by frappe machine
- applied caulking around outlet under prep sink |
| 2906 | Jim | 03/27/2025 | 00596 | - removed men’s room toilet , cleaned bottom and found no issues with wax seal. Remounted toilet and while flushing noticed small leak at bottom connection of vacuum tube which Rand along toilet and liked like it was leaking from the bottom. Replaced vacuum tube bottom gasket and all is well
|
| 2905 | Brendan | 03/27/2025 | 12272 | -replaced a bunch of cup fingers, grabber cylinder, grip pads. Calibrated ice so drinks would fill properly. Machine needs ordered a small cup tube and grab block solenoid |
| 2904 | Brendan | 03/26/2025 | 21582 | -lots of work on RO system and melitta. Eventually got it working |
| 2903 | Jim | 03/26/2025 | 21582 | - re set delivery door latch
- welded grease tray on right side of left hand grill |
| 2902 | Jim | 03/26/2025 | 00596 | - replaced O’ring on frappe machine CO2 line, no leaks |
| 2901 | Brendan | 03/26/2025 | 04205 | -repaired right coffee brewer. Replaced membrane, back plate, and control board
-melitta critical error: caused by the water being turned off…
-frappe spinner not working. Water unplugged…
-sprayfoamed pass thru holes in McCafé fridge |
| 2900 | Jim | 03/26/2025 | 04205 | - adjusted street sign latch and the door closes and latches now with a slight gap |
| 2899 | Waylon | 03/26/2025 | 02830 | -Grill pm with jim left grill |
| 2898 | Jim | 03/26/2025 | 02830 | - worked with Waylon to learn how to PM left hand grill
|
| 2897 | Brendan | 03/25/2025 | 07194 | -soda water not working at ABS. Broken flow control spring. Replaced all set
-leaking syrup line by bib rack. Repaired |
| 2896 | Jim | 03/25/2025 | 10622 | - PM’ed ice machine
, major iron build up everywhere. All cleaned now
|
| 2895 | Jim | 03/25/2025 | 10622 | - re positioned soap line into washer drum
- cut and removed broken patio seat and related parts |
| 2894 | Jim | 03/25/2025 | 04956 | - re mounted table top to posts in lobby |
| 2893 | Jim | 03/25/2025 | 04956 | - re mounted table top to posts in lobby |
| 2892 | Jim | 03/24/2025 | 18198 | -PM’ed ice machine
- replaced left hand sink drain gasket. Also had to replace 2” PVC elbow and T along with related pipes to stop leak
|
| 2891 | Jim | 03/24/2025 | 12272 | - walk in door closer broken/ leaking oil and won’t close completely
|
| 2890 | Waylon | 03/23/2025 | 00596 | -Bump bar cable for kitchen side 1 initiator
-Soda for Hi-C took of switch wasn’t clicking pushed back down and made it click |
| 2889 | Waylon | 03/23/2025 | 21582 | -installed new side 1 runner monitor
-Installed 3 new cabinet strips and installed new display board
|
| 2888 | Waylon | 03/21/2025 | 17371 | Installed new filet parts store waiting on one back order
-Installed new fcb pump and pump blew on me and got soda all over me so fuck soda |
| 2887 | Jim | 03/21/2025 | 02830 | Mounted receipt holder at front bagging area |
| 2886 | Jim | 03/21/2025 | 00596 | - swapped Qing oven with Hooksett
- cleared sink drain.with plunging and then had to open drain pipes to snake and dislodged clog about six feet in hair and buildup. Also found needle cap and reported to manager |
| 2885 | Brendan | 03/20/2025 | 02830 | -replaced ped13 |
| 2884 | Brendan | 03/20/2025 | 00596 | -side 2 printers not working. Bad cord, had to run new cord from computer to switchbox |
| 2883 | Waylon | 03/20/2025 | 00596 | -dropped of parts for hinge cover and wing oven guide went over list with Jim made sure he was good and went over list with Jeremy and super |
| 2882 | Waylon | 03/20/2025 | 21582 | -Installed 4 new palm pilot cabinet strips |
| 2881 | Jim | 03/20/2025 | 00596 | - installed metal covers on register pass thru door lock
- replaced and grouted broken baseboard tile by breaker panel
- grouted by back sink
Adjusted door sweep on delivery door
- mounted hand sanitizer unit on wall by exit
- zip tied smoke alarm box back up in ceiling, it fell down while cleaning
- replaced broken floor tile in ladies room and grouted
-grouted a few areas in ladies room walls
- re grouted few seams between ladies and men’s room
- cut and installed and grouted base tile by frappe machine |
| 2880 | Waylon | 03/19/2025 | 00596 | -Had to source parts for cabinet and reinstall new strip / new bezel / new display board used parts from office
-Qing oven broken switch burned terminal frayed wire and blown fuse ended up fixing all that still having problems with the door clicking into switch found bad door which is a first ever
-Grouted area for baseboards behind oven for Jeremy
-went over FCB install pump with Brendan |
| 2879 | Brendan | 03/19/2025 | 04205 | -store claimed “normal water is coming out carbonated”. Well that was the complete opposite. Store was just out of co2
-troubleshooted coffee brewers. Replaced three probes, a hi limit, and a fill valve. Waiting on a board to arrive
|
| 2878 | Jim | 03/19/2025 | 12272 | - re mounted mailbox and called Londonderry post office to get mail service started again |
| 2877 | Waylon | 03/19/2025 | 17371 | -Talked with Brendan regarding Jeremy’s idea to move all power lines Brendan gonna talk with Jeremy regarding that just because either we have to swap all 20 amp plugs to 30 and rerun lines under table which would be a problem when moving tables or we run it under the bun rack where they move the bun rack consistently and it will probably eat up the cords so 🤷🏼♂️ idk what he wants to do
-filet steamer is waiting on a call back from Antunes regarding a part number bent back most of the parts trying to get a quote to see if it makes more sense to replace new
-Installed new oep for filet outlet
-diagnosed fcb bad expansion tank |
| 2876 | Jim | 03/19/2025 | 25383 | - PM ice machine
- installed cover on lite pole by corral
- re glued lifted Formica in lobby vertical slats
- installed and grouted five new floor tiles by delivery door |
| 2875 | Brendan | 03/18/2025 | 02830 | -ABS not grabbing cups, bad grabber block. Replaced grabber block, two fittings, conveyor deflector, grip pads, cup locator spring, and tightened conveyor |
| 2874 | Waylon | 03/18/2025 | 18198 | -Removed tracks for quarter fridge had to rivet nuts inside fridge 3 right side one left side and re screw in ended up being a little more involved then expected had to drill out the wholes a lot
-Fridge still isn’t down to temp at like 60 degrees waited a little bit with it gonna check back tmrw morning |
| 2873 | Waylon | 03/18/2025 | 18198 | -fixed screws in track for quarter fridge
—Went through the pier merchandiser since they keep adding to the list it keeps going of on not heating must be intermittent both times I’ve came it’s been in use working but tested both fans relay and temp checked the probe
-ordered fryer probes and contractors |
| 2872 | Brendan | 03/18/2025 | 21582 | -replaced frappe water oring
-troubleshooted espresso machine error, parts on order |
| 2871 | Jim | 03/18/2025 | 04956 | - ran snake hit something about five feet in then broke thru,
Also smelled sewage and sewer cover at drive thru one has standing water on it. Advised manager on duty to call the septic company to pump it out. She also stated it had been about theee months since they came out last
- tightened left hand table next to trash bin in lobby |
| 2870 | Jim | 03/18/2025 | 10622 | - grouted in front of , ice bin,fry vats, grill vats, slop sink,&washing machine
- tightened men’s room faucet
— installed new screws on four lite poles
- drive thru sidewalk patched with cold patch
- two floor tiles replaced and grouted in front of frappe machine |
| 2869 | Brendan | 03/17/2025 | 12272 | -pos15 not powering on, plug was not fully inserted…
-looked at two door freezer not cooling enough. Called Rick
-fridge under creamer no power, tripped outlet |
| 2868 | Waylon | 03/17/2025 | 02038 | Prep fridge not temping working with Rick’s guy on it ended up being inefficient compressor |
| 2867 | Brendan | 03/17/2025 | 00596 | -troubleshooted ABS initializing loop. Didn’t find any shorted low voltage things, rebooted pos14 and moxa. Found power supply board only giving 11.9 VDC, where it should be 12.9 which can cause this issue if it’s too low. Adjust up to 12.95 so should be all set |
| 2866 | Jim | 03/17/2025 | 00596 | - removed old camera and replaced black ceiling tile
- replaced ladies room door bumper
- installed new ceiling tile above soda bibs
- replaced and grouted floor tile next to washing machine
- removed old screws from wall by old coke bulk tanks and filled holes
- touched up ladies room ceiling
- leveled tool shelf above grills
- installed new lite ballast in stock room |
| 2865 | Brendan | 03/17/2025 | 21582 | -replaced bun toaster cooling fan
-replumbed SSBS drain lines
-FFLS update |
| 2864 | Waylon | 03/17/2025 | 07194 | -Qing oven call ended up being a bad breaker automatically tripping everytime so went and had to source it only one place carries that old of breakers in stock sourced and installed
-Adjusted thermostats to their liking since they said it was too hot
-Filet steamer hasn’t had any problems since I was here last so holding on to part for it
-sink leaking out of hot water store fixed on their own |
| 2863 | Brendan | 03/16/2025 | 25383 | -time clock reimage |
| 2862 | Waylon | 03/15/2025 | 04205 | -snaked drain multiple times couldn’t get it to clear and tried to drain it out with shop vac and bucket did not have any success we should really get a bigger snake |
| 2861 | Brendan | 03/14/2025 | 00596 | -installed blue filter lights in women bathroom
-replaced cabinet strip
-replaced frayed cord pos14
-replaced deliver door glass
-removed CIP equipment
-installed screw for sugar dispenser door
-replaced freezer door padlock passcode 0596
-replaced filet steamer OEP
-replaced 4 cup tube fingers on medium tube dt abs |
| 2860 | Waylon | 03/14/2025 | 00596 | -finished installing bathroom light fixtures with Brendan |
| 2859 | Waylon | 03/13/2025 | 00596 | -Installed new men’s bathroom lights with Brendan
-Installed new abs ice machine ice curtain and it made ice
-Installed new vent hood bar behind left grill |
| 2858 | Brendan | 03/13/2025 | 00596 | -installed all new recessed lights with blue filter in men’s room |
| 2857 | Brendan | 03/12/2025 | 04205 | -installed new McCafé fridge |
| 2856 | Waylon | 03/12/2025 | 04205 | -aided Brendan with the new fridge install putting on wheels and swapping machines over took old McCafé fridge to corral cut off cord and back dangling out |
| 2855 | Waylon | 03/12/2025 | 10544 | -Welded fry station door hinge and epoxy magnets for a door closer
-Rebuild kit on back dish sink drain was pretty rough time
-Fixed microwave door hanging offf
-Diagnosed lobby shade and ordered part |
| 2854 | Jim | 03/12/2025 | 02830 | - PM ice machine |
| 2853 | Jim | 03/12/2025 | 12272 | - pm ice machine |
| 2852 | Jim | 03/12/2025 | 02038 | - re installed door closer on men’s room door |
| 2851 | Brendan | 03/11/2025 | 12272 | -replaced bad circ motor with mag drive retrofit kit. Also noticed that primary carb motor was unplugged. Plugged it in to see if it worked which it does but the motor is bad since it was pulling 15 amps. Ordered a new motor that I’ll install next time. Also noticed a leak at the booster while I’ll also fix next time. Also noticed the the prefilter housing had a crack in it causing it to have a not so tiny leak. Bypassed that filter for now because it’s a ticking time bomb until new one I ordered arrives |
| 2850 | Jim | 03/11/2025 | 02830 | Re fastened threshold in freezer and adjusted door hinges along with
Top door closer ( combination of all three, perfect storm) |
| 2849 | Jim | 03/11/2025 | 17371 | - grouted floor by front ice bin and coffee makers |
| 2848 | Waylon | 03/11/2025 | 00596 | -No Rick call for ice machine not working bad ice curtain |
| 2847 | Waylon | 03/11/2025 | 00596 | -Installed new switch for middle UHC old would stay off in on position
-Diangosed ice machine ran in clean cycle nothin ice cycle took a look at board and then found ice curtain magnet to be missing needs new ice curtain
-Installed 2 new co2 signs one above time clock and one above office door |
| 2846 | Jim | 03/11/2025 | 00596 | - grouted floor tile by sink
|
| 2845 | Jim | 03/11/2025 | 04956 | -Re installed clearance bar on drive thru one |
| 2844 | Waylon | 03/10/2025 | 21582 | -Ice machine flooding?? Ran the drain cycle twice and took video to send Brendan was going down the drain perfectly fine no backup
-I got absolutely no idea what the whole grill grease trap thing is that ticket just didn’t make sense to me
-After playing hide and seek with a package and searching the whole store found the McCafé fridge hinge and installed |
| 2843 | Brendan | 03/10/2025 | 21582 | -troubleshooting leaks SSBS. Many problems. One of lobby valves was leaking behind shutoff block. Cleared drain pan for good measure. But the drain lines on the unit need to be replumbed and I have to order the special fittings
-troubleshooting melitta error. Took me a while to figure it out. Melitta wasn’t actually the issue, it was a clogged filter on the RO that was causing the issue. Took care of that so should be all set now
-troubleshooted bun toaster. Bad probe on order |
| 2842 | Brendan | 03/10/2025 | 02830 | -frappe machine training |
| 2841 | Waylon | 03/10/2025 | 17371 | -Grills 1-3 all needed to be gapped and checked motors on 1 but once I found out it was mainly a gapping problem just gapped them all and temp tested
-welded bacon rack and hash brown rack
-Jacked up tables and changed two wheels that were slanted
|
| 2840 | Jim | 03/10/2025 | 00596 | - reinstalled lobby deadbolt for pass thru door by registers
- replaced missing ceiling grid piece by kiosks
- replaced 18 kitchen and stockroom bulbs to match
- replaced 5 door stops in ladies and men’s room
- repaired all parking lot covers and caulked and touched up bottom of posts
- picked up door dash and lobby serving box from office to replace the customer damaged one
- replaced 4 floor tiles by sink (still need grout)
|
| 2839 | Brendan | 03/07/2025 | 25383 | -troubleshooted multiplex noise. Bad circ motor, on order
-troubleshooted kiosk lights, parts on order |
| 2838 | Jim | 03/07/2025 | 21582 | -trimmed rear door latch so door would close properly
- re set drive thru side public door closer cover |
| 2837 | Jim | 03/07/2025 | 00596 | - cleared men’s room clog |
| 2836 | Jim | 03/07/2025 | 12272 | - installed coat hangers by oil tanks to keep people out of office
- repaired wheel on oven
-need to find bracket for mailbox
—adjusted present monitor
|
| 2835 | Jim | 03/07/2025 | 25383 | - filed men’s room stall door latch , closes and opens smoothly
- straightened 4 wheel dolly wheel assembly
- re mounted bottom hinge on office cabinet
- installed screw on sink backsplash
- re installed clearance bar in lane two drive thru |
| 2834 | Jim | 03/06/2025 | 00596 | - installed three screws in outside freezer door hinge
- epoxied ice bin door , no more cracks
-replaced eight kitchen ceiling tiles marked by Tara
- removed and replaced five 5 floor tile and grouted in freezer
|
| 2833 | Brendan | 03/06/2025 | 02038 | -shamrock not calibrating. Pump speed set down too slow to calibrate. Adjusted to correct value and calibrated |
| 2832 | Jim | 03/06/2025 | 00596 | - installed three screws in outside freezer door hinge
- epoxied ice bin door , no more cracks
-replaced eight kitchen ceiling tiles marked by Tara
- removed and replaced five 5 floor tile and grouted in freezer
|
| 2831 | Jim | 03/06/2025 | 02038 | - re fastened table to post , caused by high school kids vandalism |
| 2830 | Jim | 03/06/2025 | 07417 | - plunged ladies room handicap toilet, cleared clog
- Jessie stated ice machine was making ice too thick, I adjusted the thickness sensor by turning the screw to the left ten turns |
| 2829 | Brendan | 03/05/2025 | 10622 | -replaced multiplex IBC probe
-replaced music amplifier |
| 2828 | Brendan | 03/05/2025 | 17371 | -multiplex error, replaced IBC probe and drained and refilled with clean water
-recrimped dt bump bar |
| 2827 | Waylon | 03/05/2025 | 00596 | Tried to weld filter box secured one whole part super well but the bottom on the pipe which is super thin metal just instantly melted on the lowest welding setting so ordered a new one
-Installed new needle box in men’s bathroom |
| 2826 | Waylon | 03/05/2025 | 02830 | -Grill fryer low temping checked contactor seemed to be working fine checked for heat call also good checked temps with meter to board found a 15 degree diff cleaned temp probe seemed to be working great since
-When I walked in asked about fry vat low temp was told it hadn’t happened in a few days and then as I was leaving saw it happen which not gonna take a fry vat down mid lunch 😑😑
-Printers not printing swapped side 2 back to the right side since they moved around and had Brendan send a test receipt
-Pie merchandiser checked temp was at 159 with set point of 160 so removed from list |
| 2825 | Brendan | 03/05/2025 | 18198 | -fixed ice cream side squealing really loud
-replaced time clock finger print reader |
| 2824 | Jim | 03/05/2025 | 00596 | - grouted all floor tiles. Between the bathrooms & had to re set two that got loosened.
- installed two lite bulbs above sink
- cut and installed new lite lens above ice bin
- epoxied inside of I’ve bin cover , will need to come back to complete as it takes p termite to harden completely.
|
| 2823 | Brendan | 03/04/2025 | 12272 | -multiplex making loud noise. Bad recirc motor. Ordered mag drive retrofit kit, store should be ok until it comes in |
| 2822 | Jim | 03/04/2025 | 00596 | - prepped and laid twenty tiles by bathrooms
Will grout in the morning |
| 2821 | Brendan | 03/04/2025 | 00596 | -calibrated lobby coke
-tried to put gels in recessed lights in bathroom but they kept breaking. Will have to get actual light fixtures
-measured for stockroom shelf
-tried to switch music to classical but store lost remote |
| 2820 | Brendan | 03/03/2025 | 04205 | -troubleshooted water pressure issue for melitta. Clogged filter on RO, replaced. Also removed coffee brewers from that line per their request
-crimped new connector on s1 lunch bump bar |
| 2819 | Brendan | 03/03/2025 | 07194 | -UHC issue no power. Replaced switch assuming that was the issue but it wasn’t. Someone used the wrong fuse so it wasn’t making good connection. Got it running but will order correct fuse |
| 2818 | Jim | 03/03/2025 | 00596 | - removed two coke tanks
-installed screws on walk in door sweep |
| 2817 | Jim | 03/03/2025 | 02038 | - replaced lite ballast above fry station
- measured stock room storage rack track and rollers for replacement |
| 2816 | Brendan | 02/28/2025 | 00596 | -installed coke BIB pump and lines, transferred everything over fully and calibrated
-replaced co2 qdc frappe machine
-grill NTF works fine and came up to temp |
| 2815 | Brendan | 02/28/2025 | 02830 | -replaced pos6 power adapter and paired card reader |
| 2814 | Brendan | 02/28/2025 | 10622 | -replaced circ pump but still did not work. I’ve come to the conclusion it must be freezing…
-repaired present window, replaced electronic eye cable, pulley, and adjusted sensor angle
-cleared frappe drain pan and drain line
-replaced two dogging mechanisms |
| 2813 | Jim | 02/28/2025 | 17371 | - lobby drink station drain completely blocked by sludge used drain cleaner and snaked drain to clear and hand removed all the sludge in the drain basin filling a 5 gallon bucket and wiped the area as best as possible |
| 2812 | Jim | 02/28/2025 | 02038 | - re applied caulking on corian top by registers |
| 2811 | Jim | 02/28/2025 | 04956 | - tightened table in lobby
- salted driveway due to very slippery conditions on drive thru side |
| 2810 | Brendan | 02/27/2025 | 10544 | -troubleshooted muffin toaster. Cleaned out fan all set
-troubleshooted and scoped fry vat drain. Metal from support rack stuck in drain. Got it out all set.
-adjusted door closer faster for delivery door
-ordered rebuild kit for dish sink waste valve
-put in service call for roofer |
| 2808 | Jim | 02/27/2025 | 07417 | - replaced all fry sockets and all wiring and connectors
- ran drain cleaner in kitchen sink and then water all drains run free |
| 2809 | Brendan | 02/27/2025 | 12272 | -co2 leak reported by Kris does not exits. Tank has normal out of buildup, checked all equipment and found no leaks. NTF |
| 2807 | Brendan | 02/27/2025 | 02038 | -replaced ABS agitator and turned ice maker back on
-stockroom shelf jumped track again. Took pictures of tracks and rails and emailed manufacturer
-checked that OJ machine is in fact down to temp |
| 2806 | Brendan | 02/27/2025 | 07417 | -right coffee brewer not dispensing. Bad brew valve. Replaced all set |
| 2805 | Jim | 02/27/2025 | 07194 | - checked water issue in cage , floor was dry.. I spoke to Linda and Donald they both said something about ice outside.
I found a large ice buildup one the electrical meter out back, it may have followed the conduit into the building, so I broke the ice off to the ground. I told Donald I cleared the ice buildup and will clear the issue. And if it comes back during the rain or thaw to put it back on the list |
| 2804 | Jim | 02/27/2025 | 04205 | - PM ice machine
- adjusted creamer temp / product was freezing
- due to inclement weather did not work on street sign cover |
| 2803 | Brendan | 02/26/2025 | 02038 | -troubleshooted OJ machine not temping. Found water bath filled only half way due to a bad fill switch. Replaced fill switch, filled up and started coming back down to temp
-looked into stock shelf coming off track. Track is definitely really flattened out. But I did find black spoons crush underneath wheels, I think it might’ve been causing the shelf to lift up and come off of the track. Sweeped the black spoons away from track and tested about 50 times without it coming off of the track
-turned off ice machine so I can replace agitator tomorrow |
| 2802 | Brendan | 02/26/2025 | 04956 | -troubleshooted coke coming out light in drive thru. Unable to calibrate up to spec. Checked flow controls seemed ok. Ended up replacing armature which seemed to fix the issue and was able to calibrate to spec
-recrimped connector on dessert monitor bump bar |
| 2801 | Jim | 02/26/2025 | 21582 | - wile running PM flush on ice machine the floor drain overflowed, using a wet vac I got the pM completed. Then I ran my snake in the drain and tested with. Five 5 gallons of water , had no issues.
Before snaking I ran two 2 gallons in and it overflowed.
Should be fine now. I advised Shannon to call east coast if it overflowed again.
|
| 2800 | Jim | 02/26/2025 | 07194 | - pm ice machine |
| 2799 | Brendan | 02/25/2025 | 00596 | -called for flooding underneath ABS. Took off line to leak test the drain but cracked the drain fitting in the process so had to replace. Eventually I realized the drain hose had come out of the drain |
| 2798 | Brendan | 02/25/2025 | 07194 | -lobby soda flat. Replaced circulator pump and water lines |
| 2797 | Jim | 02/25/2025 | 00596 | -Troubleshooting lobby drain float switch, found it to be bad and replaced
- snaked men’s room floor drain to no avail had Rene call east coast |
| 2796 | Jim | 02/25/2025 | 04956 | Tightened all screws on men’s room divider and added epoxy to one screw that would not tighten
- added two screws to re hang serve control up front prep area |
| 2795 | Jim | 02/25/2025 | 02038 | - repaired top of men’s room door from someone ripping the door closer half off the door. I installed two new door closing hinges to prevent this from happening again |
| 2794 | Brendan | 02/24/2025 | 00596 | -leak under ABS was because the drain hose wasn’t connected to the drain. It is inaccessible so replumbed whole thing.
-back sink was bone dry NTF
-replaced cbb printer USB cable |
| 2793 | Jim | 02/24/2025 | 02038 | - removed door closer on men’s room door and sourced and installed adjustable closing door hinge will need to repair top of door and cover with stainless plate |
| 2792 | Jim | 02/24/2025 | 12272 | - replaced walk-in light sockets and installed new bulbs with protective sleeves the ballast works fine, one of the sockets had shorted and melted causing issue |
| 2791 | Jim | 02/24/2025 | 00596 | - snaked men’s room toilet, went 20 ft, nothing. Told laurel to call east coast
- cleaned sump pump under lobby drink station and ran a gallon of drain cleaner and hot water through, works good now
- replaced washer on dish sink spray hose, no leaks
- removed elbow on drain in front of ABS and snaked line, cleared clog drains fine now , could not see where leak inside ABS is coming from.
-spray foamed hole behind oil tanks |
| 2790 | Brendan | 02/23/2025 | 04205 | -emergency call removed rocks from ABS |
| 2789 | Brendan | 02/22/2025 | 00596 | -ABS not making drinks in automatic, POS cable unplugged from SS board
-coffee brewer on left was acting up, seemed like bad hi limit, replaced.
-repaired cash drawer that kept thinking it was open |
| 2788 | Jim | 02/21/2025 | 00596 | - poured drain cleaner down both ABS drains and multiple pots of hot water to clear drain. Also added pipe tape to front drain to stop leaking
- welded and leak tested fry skimmer bucket, all set
- un plugged and re plugged in coffee left hand coffee maker no issues with outlet
- installed six screws in ABS vent panel
- applied new caulking on window frame at second drive thru
- re set baseboard tile by frappe machine
- checked all other lobby drink station doors for chips, none found
- tightened sink spray hose, no leaks |
| 2787 | Jim | 02/21/2025 | 07417 | - replaced fry socket and wire |
| 2786 | Waylon | 02/20/2025 | 10544 | -Grill 3 not cooking meat call ended up just needing to be gapped took of cover to watch motors run though went through about 10 levels while gapping front motor seems to be on its way out but it’s not dead did food safety checks with GM
-Took pics of tech racks for McDonald’s |
| 2785 | Waylon | 02/20/2025 | 04205 | -Wired in electrical for new stock room light - tied into light breaker (2)
-Installed new monitor for cameras |
| 2784 | Brendan | 02/19/2025 | 02830 | -installed tech accessories on DAC
-p400 upgrades |
| 2783 | Waylon | 02/19/2025 | 12272 | Burning smell from bad light socket in freezer ordering parts for it socket is charred ballast is anxhiebt and going bad someone knocked over one of the light bulbs and shattered it 😑 so had to clean that up second light in walk in also gonna replace ballast and possibly light bulbs flickers purple in the beginning which is a typical sign ballast is going and from the looks of it both of those ballast are really old |
| 2782 | Jim | 02/19/2025 | 00596 | - cut and installed new laminate on lobby drink station door
- replaced bottom exterior hinge on freezer door |
| 2781 | Waylon | 02/19/2025 | 21582 | -installed 5 new cabinet strips
-grill call internet turns off ver very intermittent did a couple basic test but can’t find the problem without going through every part one by one which isn’t worth it |
| 2780 | Jim | 02/19/2025 | 02038 | - replaced stock room light ballast
- installed and grouted three baseboard tiles in kitchen by two drawer fridge |
| 2779 | Waylon | 02/19/2025 | 07194 | -Fry station new socket installed and adjusted wires covered with liquid electrical tape |
| 2778 | Brendan | 02/18/2025 | 00596 | -went on wild goose chase for getting music speakers in bathrooms working. Ended up having to run a new wire. Also fixed two broken lobby speakers
-fixed kiosk 6 printer issue |
| 2777 | Brendan | 02/18/2025 | 02038 | -tech training
-replaced exit sign battery |
| 2776 | Jim | 02/18/2025 | 04956 | - PM ice machine
- shimmed drive thru side two tower box to stop it from moving
|
| 2775 | Waylon | 02/18/2025 | 25383 | -Grill needed a cylinder rebuild was an absolute pain in the butt and had to get help from Alex and some of the store just to get the kit in there was a total mess and not even feeling 100% sure it’s gonna workout cause of how much the gaskets had to be fixed
-Took clearance bar down for lane 2 can’t fix in the bad wind but can take it down so it doesn’t go flying into someone’s car |
| 2774 | Jim | 02/18/2025 | 18198 | - replaced men’s room sink drain And covered all pipes an lines under sink
- replaced vestibule door closer cover
- used flex tape to repair left hand sink pipe leak |
| 2773 | Brendan | 02/17/2025 | 18198 | -ABS arm not lifting. There was so much syrup buildup in the lift guides that it was gummed up and could barely move. So had to replace that. Also had to replace grabber block because it was leaking when grabbing cups. And also had to replace umbilical because the wire on the inside was broken
-power outage corrupted pos1 all fixed |
| 2772 | Brendan | 02/17/2025 | 04956 | -replaced fuse for music amp
-fixed camera monitors not turning on after power outage |
| 2771 | Waylon | 02/17/2025 | 07417 | -Refrigeration call diagnosis is low on charge low side line 70 degrees high side 150 degrees freezer only getting down to 50 cleaned condenser got it down to 20 still not in threshold compressor and fan running notified Rick and was correct about Hanovers freezer call after talking to Rick it was low on charge
-Installed new moffit oven cord and left uncoiled so they could do with it as please let store know |
| 2770 | Brendan | 02/14/2025 | 17371 | -FCB apparently leaking from inside. Yea no leaks here from this machine. NTF
-ped2 not loading. Network cable just unplugged |
| 2769 | Brendan | 02/14/2025 | 10622 | -men’s room faucet slow flow. Found both sediment strainers plugged up on the unit and the mixing valve. Cleared out and running well now |
| 2768 | Jim | 02/14/2025 | 02830 | -Assembled prep table for front area |
| 2767 | Waylon | 02/14/2025 | 07194 | -Filet steamer (not steaming?) turned on hi limit switch was tripped heated up steamed 3-4 times tested, Adjusred regulator was set at 80 psi should be 20-30 set at 22
I was here 10 days ago reset hi limit so intemeittent hi limit will order and going to replace relay while in there possibly recommend a new power cord replacement filet steamers tend to melt power cord so might make more sense to replace at the same time |
| 2766 | Jim | 02/14/2025 | 00596 | - worked on laminate and had problems with it, need to order more to finish the job
- grouted floor area by rear sink
- re mounted pay here and pick up here signs
- cut and replaced ceiling tile by office |
| 2765 | Waylon | 02/14/2025 | 21582 | Refrigeration call
-Freezer not coming to temp compressor is over working not a ton of air flow through condenser and evaporator coil is only at approximately 40 degrees
Compressor and fan both running
Diagnostic would be to me low on refrigerant and dirty condenser coil have notified Rick of my finding and gonna see what their diagnostic is left freezer unplugged to keep compressor from overheating and burning out
|
| 2764 | Waylon | 02/14/2025 | 12272 | -Came to install cylinder for grill but part hasn’t arrived yet and Taylor doesn’t give any tracking info sadly
-put abs sensor back on with epoxy used lightly and told store to give it 20 mins before operation |
| 2763 | Brendan | 02/13/2025 | 07417 | -replaced ped13 not accepting contactless pay
-installed ped mounts for front counter |
| 2762 | Brendan | 02/13/2025 | 02830 | -coffee brewers store already fixed NTF
-vats are filtering perfectly fine NTF |
| 2761 | Brendan | 02/13/2025 | 04205 | -shake side frozen, store fixed NTF |
| 2760 | Brendan | 02/13/2025 | 00596 | -called for shake machine sundae side not dispensing issues. Store stated they replaced the o rings 4 times. One o ring was entirely missing causing the issue
-investigated lobby ceiling leak. Coming from hvac, Rick called. |
| 2759 | Brendan | 02/12/2025 | 04956 | -installed dispense touchless retrofit kit for sprite valve that kept sticking on |
| 2758 | Brendan | 02/12/2025 | 25383 | -troubleshooted cream not dispensing. Plunger came unscrewed from pincher. All set.
-replaced PSU battery |
| 2757 | Brendan | 02/12/2025 | 02038 | -troubleshooted exit sign, bad battery on order |
| 2756 | Waylon | 02/13/2025 | 07417 | -Snaked p trap for sink drain they already snaked before according to store and got a decent size blockage up we were just never notified but to make sure it was all set snaked down from sink to p to wall |
| 2755 | Waylon | 02/12/2025 | 04956 | -tracks for grill fridge screws were stripped and fallen out had to retap holes and source screws made a hopefully long term solution with Brendan regarding those since they break so often
-cut ceiling tile for tech rack
-briefly looked at sprite in lobby needs a new switch |
| 2743 | Waylon | 02/10/2025 | 02830 | -Installed new heater board for cabinet
-this shouldn’t of taken as long as it did was just ridiculous installed new diamond plate for outside freezer door to cover rust was supposed to be 48 inches was cut to long from Lowe’s so had to grind down the sides to make it fit the door and then cause if the plate door doesn’t lock as good so need to dremel out the lock but it works and covers the rust |
| 2752 | Waylon | 02/11/2025 | 18198 | -Finished install for grill on the grill solenoid started to release air still wasn’t releasing air as well average time to close was about 4.8 seconds or a little over was way to high searched all lines for a leak sprayed with degreaser to see bubbles light bubbles around solenoid not enough for it to be a serious problem took off elbow fitting into cylinder replaced since fitting was partially broken - took elbow fitting off pneumatic block tested straight from block airflow seemed pretty low took out block cleaned with a pick still continued problem
Gave Brendan the rundown he’s gonna double check the bad block since it’s over a grand to replace and I want a double check before spending that much |
| 2754 | Waylon | 02/12/2025 | 00596 | -Grill blower failure when arrived grill was off but they said they had been using it and said went off on ignition failure turned on grill came up to temp checked all relays, checked contactor voltage, checked voltage from board, checked power supply voltage, took of side panel after having a lot of trouble with gas line , watched blower motor turn on and spin properly no problems came up to heat after turning on and off 4 times, main problem found was a gas leak at line into grill have called Taylor regarding that since it has to do with gas
Calling a NTF diagnosis besides gas line for this if anything I’m thinking a control board could be bad giving faulty errors but not positive
-HLZ blown fuse went a little further to check why it was blown seems like plate heater relay is starting to go faulty but it’s definitely still doing its job just not as well so gonna leave it alone
|
| 2753 | Jim | 02/12/2025 | 00596 | - replaced two floor tiles under lobby table
- installed new light bulb in simplified breakfast cabinet ( second bulb was broken upon removal from the box
- tightened ladies room handicap toilet seat |
| 2751 | Brendan | 02/11/2025 | 10622 | -troubleshooted shake machine. Shake side all froze up. Called Taylor since the part it needs is under warranty still |
| 2750 | Brendan | 02/11/2025 | 18198 | -troubleshooted grill to verify, indeed a bad manifold block. On order.
-left coffee brewer working upon arrival NTF |
| 2749 | Brendan | 02/11/2025 | 04205 | -replaced power supply and mounting screws for oven timer |
| 2748 | Jim | 02/11/2025 | 02830 | - disassembled the shake machine outlet and rebuilt electrical box and remounted outlet back into position.
|
| 2747 | Jim | 02/11/2025 | 00596 | - replaced baseboard tile and grouted by smart clock
- installed and grouted tile in front counter area
- - repaired FRP trim in multiple areas
- grouted ladies room walls as needed
- installed new wax seal on men’s room toilet
- filled holes in stall doors in both bathrooms
|
| 2746 | Brendan | 02/11/2025 | 00596 | -replaced terminal block and rewired broken wires. Vat heats as expected
-had to clean up a while vats worth of oil that I drained on the floor because the filter pan was full😭😭😭😭
-crimped new QDC for frappe co2 |
| 2745 | Jim | 02/11/2025 | 00596 | - replaced baseboard tile and grouted by smart clock
- installed and grouted tile in front counter area
- - repaired FRP trim in multiple areas
- grouted ladies room walls as needed
- installed new wax seal on men’s room toilet
- filled holes in stall doors in both bathrooms
|
| 2744 | Jim | 02/11/2025 | 00596 | - cleaned and re caulked sink backsplash and mop sink
|
| 2740 | Jim | 02/10/2025 | 00596 | - Installed door sweep on exterior vestibule door drive thru side
- replaced left hand side weatherstripping on delivery door
- installed pvc cover over long crack on FRP to the left of the sink
- adjusted lobby drink station drain
- cut and installed new baseboard tile by frappe machine & grouted
- grouted baseboard tile by crew room
- installed trim above present baseboard tiles
- replaced five baseboard tiles by coke tanks and grouted
- picked up 24 kitchen ceiling tiles left in crew room
- replaced spray hose on kitchen sink |
| 2742 | Brendan | 02/10/2025 | 04205 | -troubleshooted oven timer, bad power supply. On order |
| 2741 | Brendan | 02/10/2025 | 00596 | -water pressure issues; filter clogged, all set
-frappe rinse spinner not spinning, just dirty. All cleaned
-assembled new bib rack, slid over BRP and remounted |
| 2739 | Waylon | 02/10/2025 | 12272 | -Cylinder rebuild for grill
-Installed new toilet paper dispenser |
| 2738 | Brendan | 02/10/2025 | 04956 | -coffee brewer no power, bad board. Replaced and calibrated |
| 2737 | Jim | 02/07/2025 | 00596 | - snaked 20 feet and poured a gallon of drain cleaner into ladies room floor drain
No luck this time |
| 2736 | Jim | 02/07/2025 | 12272 | - poured drain cleaner and snaked ladies room floor drain
Seemed to clear clog about 15 feet in, checked with five toilet flushes in a row, no backup anymore |
| 2735 | Jim | 02/07/2025 | 04205 | - got to second street to reset roof top heating units and ricks guys were there troubleshooting the units to see why they had no heat |
| 2734 | Jim | 02/07/2025 | 00596 | - cleared drain issue in lobby drink station and adjusted drain lines for one inch gap
- trimmed pvc pipe to allow one inch gap for drain at prep sink |
| 2733 | Jim | 02/07/2025 | 04956 | - removed and replaced six floor tiles and grouted, by fry station
- replaced battery in Detex unit by delivery door |
| 2732 | Waylon | 02/06/2025 | 07194 | Grill call for no heat error faulty element or shorted probe: got there grill was up to temp and in use to make sure grill was fine checked
Contractor voltage : 208
Relay voltage : 208
Amp draw on main legs: 27 per leg
Overall diagnosis: NTF
screwed down freeze door step plate |
| 2731 | Waylon | 02/06/2025 | 18198 | -Diagnose grill not latching looks like a bad solenoid checked air relief on top of cylinder was doing good when swapping. Lines from cylinder 1-2 probably only stayed on solenoid 1 ordered new solenoid and elbow for quick disconnect
-2 drawer fridge by FC top drawer broken again they keep putting a ton a ton of stuff in the drawers weighing them down bending the screws out so then it catches… removed drawer after much difficulty took out bent screw and other screws on bracket loctited new and screwed in if breaks again probably just gonna weld it on at this point |
| 2730 | Brendan | 02/05/2025 | 21582 | -troubleshooted OJ machine temping too high, water solenoid stuck closed so water bath wouldn’t fill. Tapped a few times to get unstuck. Both cabinet and product is temping out now
-crimped new connector on cbb bump bar
-ordered hinge for McCafé fridge door |
| 2729 | Brendan | 02/05/2025 | 00596 | -right grill PM
-replaced detex battery
-went to replace fry vat 2 contactors, wires were really crumbly so had to change them. Buttttt when I took the wire out of the terminal block, the terminal block totally disintegrated so will have to order that |
| 2728 | Jim | 02/05/2025 | 00596 | - filled holes in delivery door
- filled holes in wall above mop sink
- installed new hanger for front fire extinguisher
- replaced 4 bulbs in kitchen
-replaced light lens in kitchen light
- replaced kitchen light with led unit
Installed new T8 24 inch bulb in double fridge up front
|
| 2727 | Waylon | 02/05/2025 | 00596 | -South willow grill PM |
| 2726 | Jim | 02/05/2025 | 21582 | - hand sink temp issue is due to main tank being unable to keep up during high hot water use.
The current tank is a residential unit with maximum capacity of 50 gallons, all other store have commercial units and they are 80 gallon models with faster recovery rates.
- cleaned frappe drain to prevent a drain clog |
| 2725 | Jim | 02/05/2025 | 07194 | - filled holes in ladies room wall and put hand wash sign over it
- soap dispenser remounted
- re temped hand sink
- replaced baseboard tile by entry to tea brewer and grouted
- replaced ceiling tile in lobby |
| 2724 | Waylon | 02/04/2025 | 07417 | -Snaked and cleared drain in men’s bathroom shakes an extra time then used drain cleaner and dumped two 5 gal buckets down drain |
| 2723 | Brendan | 02/04/2025 | 00596 | -troubleshooted CIP panel, will transition to BIB coke
-got nugget freezer working, idk if it will stay so keep an eye on it
-unclogged grill hand sink, full of recons lol
-troubleshooted platen 1, adjusted Venturi seems okay now
-replaced cup finger large cup tube ABS |
| 2722 | Jim | 02/04/2025 | 21582 | - replaced ballast on side two landing zone light |
| 2721 | Waylon | 02/04/2025 | 18198 | Front drive thru window just put back together didn’t see any significant break could be wrong was doing it quickly |
| 2720 | Jim | 02/04/2025 | 07194 | - picked up and replaced men’s room mirror
- removed old and installed new laminate on lobby drink station doors
- cut and replaced 2 ceiling tiles outside ladies room
- installed new holder for walk in curtain |
| 2719 | Waylon | 02/04/2025 | 07194 | -Welded hand rail bars back on and primed / painted
-Installed new 3n1 for fridge it’s already down 25 degrees told the store to keep an eye on it to make sure that was 100% the problem |
| 2718 | Brendan | 02/04/2025 | 07194 | -replaced ABS drain pan and sensors |
| 2717 | Brendan | 02/03/2025 | 07194 | -troubles Zoom timer, when I replaced the TSP I swapped the present and cash window. All set now, my bad.
-replaced cup fingers large cup tube ABS and replaced broken gripper pad
-removed SSBS door, I was worried because the color of the new Formica looked different than the existing but was just the lighting lol |
| 2716 | Brendan | 02/03/2025 | 10622 | -repaired exploded water line in the multiplex, unfortunately it killed the motor under it. Replaced the motor which took forever because I had to grind off the bolt because it was stuck. Then after all the the spare motor I had on me was defective… on order |
| 2715 | Waylon | 02/03/2025 | 07194 | -Filet steamer heating error was a tripped hi limit they said it was pouring out the sides with water checked water lines and regulator and ran for an hour no leak found
-HLZ new cord installed
-installed changing table in men’s room needed new holes drilled took forever to get through the tile only did 2 new holes
-Diagnosed prep fridge not coming to temp was a bad 3 in 1 going into compressor, tested compressor tested all good
-installed new grill pulley and screw then tested and gapped grill
-Had to drill out a qing oven screw broken and replace
-Door handle for first tbh don’t think this will last more than a day really needs to be riveted I think or new holes in general but put 1/4 screws in and loctite |
| 2714 | Brendan | 02/03/2025 | 04956 | -repaired sprite lobby valve
-disassembled and reassembled ice chute for store so they could clean
-adjusted ice gate that kept getting stuck open |
| 2713 | Jim | 01/31/2025 | 00596 | - sourced and replaced sink drain pipe on men’s room sink |
| 2711 | Waylon | 01/31/2025 | 25383 | -Grill 4 needed to be gapped way way off regapped old grills so was a pain in the ass in the middle of gapping one side the opposite side had an electrically spark then the grill began to heat over set point looked at relays one was letting 50 volts passed it and the other was stuck open so had to install 2 new relays and finish gap then temp checked temped out raised temp by 2 seconds at 47 because the right corner was at like 150 degrees the platen has excessive carbon build up on so let store know but seems like more carbon problem then gap |
| 2710 | Jim | 01/31/2025 | 21582 | - removed delivery door crash bar and re set dogging device to latch
Works fine now |
| 2709 | Jim | 01/31/2025 | 04956 | -replaced 11floor tiles and grouted |
| 2708 | Brendan | 01/30/2025 | 02830 | -replaced Fanta bib pump |
| 2707 | Waylon | 01/30/2025 | 17371 | Caulked holes by dish sink
Looked at both freezers prior to Doug coming ended up being right on both my diagnostics of them but went over everything with Doug when he got there and he showed me how to test a compressor and more about how freezers work because they are different then basic refrigerators
Ordered parts for one Rick can deal with cleaned the condenser coil off on the other |
| 2706 | Jim | 01/30/2025 | 02038 | -PM kitchen ice machine |
| 2705 | Brendan | 01/30/2025 | 00596 | -troubleshooted middle fry vat, butttt then fire alarm went off so had to evacuate and we were waiting forever, turns out our alarm panel isn’t connected to the fire dept? Anyway problem is bad contactor, on order
-replaced o ring on frappe machine water line |
| 2704 | Brendan | 01/30/2025 | 25383 | -mobile code troubleshooting. Sorry had to bill, was more time consuming than expected |
| 2703 | Jim | 01/30/2025 | 12272 | - sourced and replaced two fluorescent bulbs in light above drive thru one
- replaced two floor tiles under grill left side and grouted
- grouted two baseboard tiles one in office and one under hand sink
- re attached present window chain |
| 2702 | Brendan | 01/29/2025 | 10622 | -completed p400 upgrades
-troubleshooted dt window. Replaced motor that was going bad. Door ate up sensor cord, needs new sensor. Also needs new kilrol pulley as it’s pretty stiff. On order |
| 2701 | Waylon | 01/29/2025 | 17371 | -replaced outside door handle
-Uninstalled walk in door handle that arrived broken installed new door handle and tested gave return box to Brendan for shipping
-Cut out two wall tiles and grouted the whole section under breaker panel
-Grouted vestibule spots
-Caulked multiple holes outback
-working with Doug (HVAC) on rooftop units and he was teaching me some of the basics
Turned hvac fan to on 24/7 which according to Doug is how they are supposed to be then went on roof and checked contractors pulling in for fan to run
-put a screw in freezer door for hinge not sure how well it’s gonna hold up to be honest it’s just a sheet metal screw
|
| 2700 | Brendan | 01/29/2025 | 17371 | -replaced FFLS print mech
-replaced coke tank head |
| 2699 | Jim | 01/29/2025 | 12272 | - replaced ballast in ladies room handicap stall
Replaced base tiles in office and under hand sink
- straightened bun chute so it won’t fall off when touched
- replaced two walk- in bulbs
- replaced # 40,42 double breaker for lot lights
- tightened screws on quarter pounder drawer handle |
| 2698 | Brendan | 01/28/2025 | 02830 | -network rack cleanups
-replaced carb b motor
5hrs + 2.5hrs differential |
| 2697 | Brendan | 01/28/2025 | 21582 | -was going to replace oven probe but was told the oven has been normal since last time, will keep an eye.
-replaced hi limit, crimped burning connector, and removed obsolete parts on left coffee brewer |
| 2696 | Brendan | 01/28/2025 | 04956 | -replaced faulty ped13
-replaced FFLS print head |
| 2695 | Waylon | 01/27/2025 | 02830 | Diagnosed cabinet with Brendan new cabinet neither of us have had to work on before really not a fan of the setup on it cause there’s a lot of extra things that are unnecessary lost half our voltage at heater board 1 causing it to give the error code so we believe bad board
-Started building tech rack but found the one in the closest already should work since theirs conduit under the rack that was missed McDonald’s will have to be okay with it got rid of the wood en pallet that the ne wrack came in cut up and trashed
|
| 2694 | Brendan | 01/27/2025 | 02830 | -replaced lobby mop sink cartridge
-prep for network rack cleanup |
| 2693 | Jim | 01/27/2025 | 12272 | - set hand sink temp, all good now
- cut and replaced two lobby ceiling tiles
- cleaned and re caulked sink backsplash
- adjusted and caulked wall trim piece on side 2 |
| 2692 | Waylon | 01/27/2025 | 17371 | -Installed new door latch for walkin door both sides and it ended up coming broken with the key snapped off found when testing after install 😐
-Installed new drip tray for McFlurry mixer
-looked at sticker machine not printing right reset multiple times recalibrated and cleaned sensor couldn’t fix it pretty sure Brendan’s gonna take a look for further diagnosis
-Welded nugget basket back together kept it very light on welds and power gonna see how it holds up since I didn’t wanna melt the whole thing
-looked into fry vat not sensing the bin was working correctly when I pulled it out and put it back in multiple times |
| 2691 | Brendan | 01/27/2025 | 00596 | -removed prong from plug socket
-looked at dt speaker greeter. Messed around but seems like working as designed
-co2 leak due to bad coke tank nozzle, replaced all set |
| 2690 | Jim | 01/27/2025 | 07194 | - added final coat of mud on crew room entrance
- finished grout at walk- in and crew room entrance
— gave Donald (4)o’ rings for the coke tank connection
- installed new cover on Main Street sign
- replaced two base tiles by small door near bulk coke tanks and grouted |
| 2689 | Brendan | 01/27/2025 | 07417 | -replaced fry bulb socket, also added a 5th socket that was requested |
| 2688 | Brendan | 01/24/2025 | 02830 | -replaced carb b probe harness
-multiplex water bath probe error was due to the sensor being misaligned and consumed by ice. Realigned all set
-HiC working NTF
-troubleshooted lobby mop closet faucet, ordered new cartridge |
| 2687 | Brendan | 01/24/2025 | 10544 | -completed p400 upgrades |
| 2686 | Jim | 01/24/2025 | 02038 | - removed and installed new wax seal and closet bolts on men’s room toilet |
| 2685 | Jim | 01/24/2025 | 07194 | - installed air fresheners in men’s and ladies room
- remounted ice bucket and scoop to better areas
- dropped men’s room mirror off at Queen City glass
- repaired crew room entrance, needs final sanding
- replaced two baseboard tiles, one at crew room entrance and the other at walk in they still need grout |
| 2684 | Brendan | 01/23/2025 | 21582 | -troubleshooted oven. Going to order a new probe
-installed fryer splash guards
-cleared out my box of presents |
| 2683 | Brendan | 01/23/2025 | 00596 | -oven store already fixed
-back faucet NTF |
| 2682 | Brendan | 01/23/2025 | 12272 | -repaired oven door latch
-unclogged McCafé ice bin drain
-repaired dt window 2 chain fell off
-adjusted walk-in door closer |
| 2681 | Brendan | 01/23/2025 | 02038 | -troubleshooted multiplex warm, low on gas. Rick called
-troubleshooted leak in the wall. Due to old abandoned coffee brewer line that instead of being capped off, was just kinked and zip tied… properly capped off and removed line from wall. |
| 2680 | Waylon | 01/23/2025 | 02038 | Right qing oven new blower motor installed other was faulty and wobbled heating problem was a bad magnetron replacing that was a decent bit of work |
| 2679 | Jim | 01/23/2025 | 21582 | -replaced light ballast on light above sink
- checked TP dispensers all secured |
| 2678 | Jim | 01/23/2025 | 04205 | - cut and installed two new lobby baseboard tiles and grouted
- replaced baseboard tile underneath dishwasher and grouted
- found leak on dishwasher and Lynn called eco lab as their part is leaking
- hung new ceiling light in stockroom |
| 2677 | Waylon | 01/23/2025 | 18198 | -Abs said not working literally always works when I’m there but seems like it’s getting stuck when grabbing cups the theory is whenever it gets too cold the arm gets stuck down from the metal shrinking but threw two washer in hopefully to create a gap from metal to arm tested worked good now we will see if something happens, I’ve taken two Quick Look’s at it Tuesday and Wednesday but it always works for me and I make multiple drinks each tkme |
| 2676 | Waylon | 01/22/2025 | 04956 | -New grill cord was a little more work than expected
-9 cabinet strips was awful |
| 2675 | Jim | 01/22/2025 | 00596 | - R&R men’s room toilet, remove and clean old wax seal and floor area, install new wax seal, reconnect all plumbing & test, All set
- installed azek trim piece above base tiles behind oil tanks to seal openings |
| 2674 | Jim | 01/22/2025 | 02038 | - sourced and replaced three lobby light bulbs to match others
- removed and replaced three White wall tiles, tried to see if I could find in wall leak, there is a black hose running down from the ceiling it is a Coca Cola line. The only access is from the ceiling and to repair will require a large area of the wall to be removed and replaced.
|
| 2673 | Brendan | 01/22/2025 | 17371 | -recrimped bump bar connector
-replaced part on walk in handle. Unfortunately will need to order new handle
-reinstalled light lens |
| 2672 | Brendan | 01/22/2025 | 04956 | -looked into exhaust issue. Motor is seizing then cutting out on overload
-D1 at 54°
Called rick for these |
| 2671 | Brendan | 01/21/2025 | 04956 | -repaired oven. Installed new relay/contactor retrofit kit to replace esafe relay. Was such a pain, I had to drill new holes to mount, had to rewire most of the oven and crimp like 14 crimps
-strawberry shake NTF |
| 2670 | Jim | 01/21/2025 | 12272 | - replaced two seals on delivery door, looks like it got hit by the electric pallet jack
- repaired cover on ice bin
- covered seam on vestibule wallpaper, seam opened up |
| 2669 | Waylon | 01/21/2025 | 07194 | -Grill Pm then noticed wasn’t heating up fast and left motor wasn’t gapping went to replace motor further investigated heating found broken wire Brendan did the wire repairing I took the whole motor harness out replaced motor this isn’t a permanent fix for the wire we ordered new harness cables and then when putting back together screw head broke inside the pulley so now the pullley is broken too I don’t carry any of those so that’s a special order to Taylor
This pm led to a lot of broken equipment that’s why PMs sucks
-Had to clear ice out of evaporator cause it got blocked up
-replaced cabinet switch |
| 2668 | Brendan | 01/21/2025 | 07194 | -Left grill PM. Found a bad motor so worked on replacing that. Also found that top platen was heating very slowly due to wire being broken. Repaired that. Unfortunately a screw broke in the pulley so they’ll be down that platen until a new one comes in
-replaced cam lock on happy meal toy display with correct size |
| 2667 | Jim | 01/21/2025 | 17371 | - cleaned outside overhang and removed mud hornet nest on entry window
- painted coin box at drive thru one |
| 2666 | Jim | 01/21/2025 | 04956 | - plunged and cleared men’s room urinal, added drain cleaner, works fine now.
|
| 2665 | Waylon | 01/20/2025 | 17371 | -swapped 3 door knovs inside out and had to grind latches down for two
-installed new fridge cord
-installed new Dr Pepper head bib
-grouted woman’s bathroom corner |
| 2664 | Brendan | 01/20/2025 | 25383 | -ABS soda water issue. Was just ice built up in nozzle due to cold weather. Rinsed with warm water all set |
| 2663 | Brendan | 01/20/2025 | 00596 | -crimped new connect dt present bump bar |
| 2662 | Brendan | 01/20/2025 | 07194 | -fingerprint scanner NTF
-replaced defective booster storage tank and charged
-replaced defective RO permeate pump |
| 2661 | Waylon | 01/20/2025 | 18198 | -Frozen hinge on corral doors |
| 2660 | Brendan | 01/19/2025 | 04956 | -troubleshooted oven “runaway” error. esafe relay bad and bypassing so it keeps heating. Conversion kit on order, should arrive wednesday |
| 2659 | Brendan | 01/19/2025 | 04205 | -emergency call soda water not stopping, all set removed rock causing the issue |
| 2658 | Jim | 01/17/2025 | 17371 | - installed bolts in tool trays above the grill to make them level again
- painted the trim around both entrances and sanded the grey plate for the first drive thru Ronald McDonald house charity change holder
- found cover for the waterlines at the frappe machine and shake machine |
| 2657 | Brendan | 01/17/2025 | 07417 | -replaced brew solenoid left coffee brewer
-noticed neither brewers had their warmers disabled, not sure how they never got marked off on it. All disabled now |
| 2656 | Brendan | 01/17/2025 | 18198 | Fixed ABS not grabbing cups |
| 2655 | Jim | 01/17/2025 | 10622 | - cut and installed two aluminum corner trim at ice machine
- cut and installed one aluminum corner trim by frappe machine
- straightened four curbside signs
- repaired lobby picnic table top
|
| 2654 | Jim | 01/16/2025 | 04205 | - re attached counter top next to lobby drink station
- replaced faucet on hand sink to hands free unit |
| 2653 | Brendan | 01/16/2025 | 12272 | Gas |
| 2652 | Brendan | 01/16/2025 | 21582 | -replaced muffin toaster motor |
| 2651 | Brendan | 01/16/2025 | 21582 | -replace breakfast toaster motor |
| 2650 | Brendan | 01/16/2025 | 07194 | -installed and adjusted new breakfast toaster
-replaced cbb printer cord |
| 2649 | Brendan | 01/16/2025 | 00596 | -troubleshooted grill in ignition failure, adjusted venturi valve and got it working |
| 2648 | Waylon | 01/16/2025 | 02038 | -Qing oven burn smell and not heating so blower motor is definitely bad I checked transformer, fuses, capacitor, and diodes only thing I didn’t was the magnetrons there is a small heat issue that has been going on for a while I guess but I need a properly working blower motor first to finish the test either way ordered parts for store and for van so hopefully with van stock I’ll have all the stuff |
| 2647 | Brendan | 01/16/2025 | 12272 | -fixed pos12 touch screen
-ordered lot light breaker |
| 2646 | Jim | 01/16/2025 | 04205 | - re attached counter top next to lobby drink station
- replaced faucet on hand sink to hands free unit |
| 2645 | Jim | 01/16/2025 | 02830 | - replaced men’s room sink strainer and drain pipe assembly
|
| 2644 | Waylon | 01/16/2025 | 18198 | -Installed new egg crate in lobby
-Used quick set epoxy to put the sink cover back down
-Removed old co2 alarms and lines up to ceiling
-caulked a ton of holes
-Libby blind installed new chain the chuck seems to be going soon to but would prefer to save my other one incase emergencies |
| 2643 | Brendan | 01/15/2025 | 18198 | -replaced ABS sprite solenoid
-tightened shutoffs in ABS
-troubleshooted shake machine not giving ice cream, found barrel frozen up and pump tripped out. Reset pump and thawed barrel seems to be working fine now |
| 2642 | Jim | 01/15/2025 | 17371 | - got paint for exterior trim and siding all completed, left paint in closet by drive thru 1
Called Kason about the wrong lock set that was sent, they stated they will research and get back to me |
| 2641 | Brendan | 01/15/2025 | 10622 | -water coming from water softener, calling gilford well
-breakfast cabinet overflowing in the morning. Float switch a bit stiff due to lime buildup. Cleaned float and troff, moves a lot better now
-reaffixed hi limit panel in fryer
-added Michael’s problems to list |
| 2640 | Jim | 01/15/2025 | 17371 | - got paint for exterior trim and siding all completed, left paint in closet by drive thru 1
Called Kason about the wrong lock set that was sent, they stated they will research and get back to me |
| 2639 | Waylon | 01/15/2025 | 18198 | -Installed new plywood and carpet for freezer pit adhesive to the board so waiting for it to set and then sealing it
-Wiped back of ice machine just incase
-used some white paint to try and cover a broken tile chip
Removed bathroom battery pack under men’s room faucet |
| 2638 | Jim | 01/15/2025 | 18198 | - helped Waylon with plywood for temporary freezer flooring
- replaced three light lenses on side 2 in kitchen
- straightened and re-fastened ramp in walk-in to freezer |
| 2637 | Waylon | 01/13/2025 | 18198 | -fixed ansel system safety attachment
-Broken tile in crew room
-Grouted bathroom
-Had to source a similar ceiling tile
|
| 2636 | Waylon | 01/14/2025 | 18198 | -ice machine pm was already in really good shape
-Made 2 drawer fridge close properly still semi slanted but closes smoothly
-Sanded door latch down closes properly now
-cut metal for a cover in lobby
-Replaced ceiling tiles and moved 2 around
-had to replaced cord on HLZ shocked someone was frayed |
| 2635 | Jim | 01/14/2025 | 10622 | -finish coat of drywall mud applied to crew room wall |
| 2634 | Jim | 01/14/2025 | 17371 | - applied bondo to numerous areas on exterior trim and siding, and sanded
- added stud and nut to CO2 tank leg ( left tank rear leg)
- ordered part for walk in inside latch
- re drilled and hung pay here sign
- ladies room water temped fine 104
- replaced kitchen sink spray nozzle |
| 2633 | Jim | 01/14/2025 | 10622 | - applied drywall mud to large hole in wall
|
| 2632 | Brendan | 01/13/2025 | 18198 | -replaced cbb bump bar
-abs soda leak is a mess, don’t have parts since they are all in my van which is in the shop |
| 2631 | Brendan | 01/13/2025 | 02830 | -replaced cbb bump bar
-NTF co2 tank |
| 2630 | Brendan | 01/13/2025 | 25383 | -called for no soda. Working upon arrival, checked it out didn’t see anything amiss. NTF |
| 2629 | Jim | 01/13/2025 | 10622 | - re attached the stainless steel panel to the wall at the slop sink
- filled hole in wall in crew room |
| 2628 | Brendan | 01/13/2025 | 00596 | -got copies of shed key that the didn’t have only to find out the wrong lock is on the shed and it’s the old key that they already had on their keychain |
| 2627 | Brendan | 01/13/2025 | 21582 | -troubleshooted muffin toaster, bad motor
-replaced bugged freezer handle what a pain |
| 2626 | Jim | 01/13/2025 | 17371 | - replaced one Drive thru corner trim and applied bondo to seam and other corner trim, once hardened I will sand and paint to match
- did PM on kitchen ice machine, needed extra time to remove buildup
|
| 2625 | Brendan | 01/13/2025 | 04205 | -repaired leaking water line for frappe
-pos14 touch screen needed to be unplugged plugged back in |
| 2624 | Brendan | 01/13/2025 | 07194 | -checked out cracked kiosk screen, took info to send for repair
-checked drink printer, definitely all plugged in. May need new cord but don’t have any since van is in shop |
| 2623 | Brendan | 01/10/2025 | 25383 | -replaced kiosk6 controller
-repaired emergency light |
| 2622 | Jim | 01/10/2025 | 17371 | - grouted in front of griddles, fry products vat, in front of ice machine, and by walk in door
- replaced broken floor tile and grouted
- grouted white wall tiles (4)
- relocated wire shelf to left of walk in door
- set all faucets with Alex for proper temps
- swapped mixing valve and waterline for men’s room sink |
| 2621 | Waylon | 01/10/2025 | 18198 | -Glued bolt for co2 tank
-new fry monitor eproduction
-Filled holes by maint closest
-Went over RGR stuff with Jeremy Drew and Michael goal is to have them done by Monday |
| 2620 | Brendan | 01/09/2025 | 10622 | -replaced biscuit oven switch |
| 2619 | Brendan | 01/09/2025 | 07194 | -replaced TSP
-p400 upgrades complete |
| 2618 | Waylon | 01/09/2025 | 18198 | -Installed monitor for side 1 breakfast
-Installed fire extinguisher and made a makeshift label
|
| 2617 | Jim | 01/09/2025 | 17371 | - grouted floor in front of fryer
- cut and replaced 11 kitchen ceiling tiles
- cut and replace two vestibule ceiling tiles |
| 2616 | Waylon | 01/09/2025 | 04205 | -Grill emergency call gas was shut off they figured it out before we got there |
| 2615 | Brendan | 01/08/2025 | 10622 | -by the multiplex was bone dry with no signs of leak
-adjusted schedule for K1
-repaired dt automatic window |
| 2614 | Jim | 01/08/2025 | 04205 | - adjusted faucet in men’s room for temp and pressure, need new faucet for right side sink
- replaced weatherstripping on trash door, door frame needs to be rebuilt sometime, |
| 2613 | Waylon | 01/08/2025 | 07194 | -Grill platen 1 not going down fully was a grease shield getting stuck took of back and cleaned tested and now going down
- took of wheel and installed new one problem is I thought it only need one wheel due to how the list phrased it but needs 2 one of each back left and right so gonna order more wheels and in cases where the rubber is causing the wheel to not roll gonna replace both back wheels
-had manager run food safety on grill and tested voltage at contractor because the plugs are pretty awful |
| 2612 | Brendan | 01/08/2025 | 17371 | -cash drawer pos13 they already fixed themselves.
-leak by ABS was clogged drain pan, all set |
| 2611 | Jim | 01/08/2025 | 17371 | - removed and straightened electrical panel in crew room
- filled holes between shake and frappe machines
- grouted wall tiles in ladies room
- filled hole to right of walk-in
- cut and installed 3 white wall tiles in crew room next the power panels
- replaced white wall tile under electrical panel next to time clock |
| 2610 | Brendan | 01/07/2025 | 04205 | -replaced dead hotg monitor |
| 2609 | Brendan | 01/07/2025 | 00596 | -coffee brewer “smoking”. Apparently it was just steam they’ve been using all day NTF |
| 2608 | Waylon | 01/07/2025 | 18198 | -Root beer in lobby wasn’t working no had a bad switch on it and need recalibration |
| 2607 | Jim | 01/07/2025 | 17371 | -sourced, cut and replaced 14 light lenses. All were either cracked or warped |
| 2606 | Brendan | 01/07/2025 | 02830 | -tea brewer not priming. found co2 changeover switch was flipped in-between, so it wasn't getting full pressure. all set
-put in fry basket supports
-fixed cab printer not printing |
| 2605 | Waylon | 01/07/2025 | 04956 | -Grill platen 1 needed a new belt installed
-Ordered new 12/5 cord for frayed grill cord at the moment it isn’t broken or causing any problems so taped and waiting for new one to come in
-Installed new cabinet switch other was stuck on 24/7 |
| 2604 | Brendan | 01/06/2025 | 07417 | -installed replacement pos2 that someone killed with hot chocolate 🫣 |
| 2603 | Waylon | 01/06/2025 | 18198 | -Lingest solo grill on ever was a actual mess
-New grill wheel. Installed
Had to regap the whole grill and did temps
-Installed a new extension to abs drain line with 90 hopefully we can put a grate cover in for that drain to keep all the pipes in there in the future |
| 2602 | Jim | 01/06/2025 | 17371 | - sourced and installed two light lenses and mop holder by walk in |
| 2601 | Jim | 01/06/2025 | 10622 | - removed men’s room faucet electronic control and disassembled, cleaned screens and reassembled
Works fine |
| 2600 | Brendan | 01/06/2025 | 02830 | -replaced IBC probe |
| 2599 | Jim | 01/06/2025 | 02038 | - replaced lite lense in kitchen
- trimmed door latch on delivery door |
| 2598 | Jim | 01/06/2025 | 21582 | - replaced door sweeps on both rear doors
- checked urinal flush, works fine, in store maintenance repaired it |
| 2597 | Brendan | 01/04/2025 | 04956 | -cherry Fanta leaky, rebuilt dispense valve and replaced pressure relief |
| 2596 | Brendan | 01/04/2025 | 07194 | -replaced hot water handle right brewer
-rebuild kit hot water dispenser left brewer. Water line was too long causing it to raise and not dispense well so corrected that.
-replaced dt window 1 handle
-reaffixed ped13 paddle
-installed new insulation back ice bin lid
-troubleshooted muffin toaster, bad infinite control causing it to constantly heat until the hi limit trips. Also 3 bad elements. Toaster is no longer approved so new toaster on order |
| 2595 | Brendan | 01/04/2025 | 02830 | -emergency call no carb water at ABS multiplex E7 E9. Motor was locked up removed pump and reassembled and worked🤷🏻♂️chocking it up as a fluke. Need to replace IBC probe will follow up on Monday
-tightened loose dish washer sprayer head
-installed cbb printer/bump bar mount
-replaced broken Dr Pepper nozzle |
| 2594 | Brendan | 01/03/2025 | 21582 | -emergency call, water spraying from carbonator. Replaced probe and pressure relief all set
-installed CLD bracket |
| 2593 | Brendan | 01/03/2025 | 00596 | -replaced oven switch + addition troubleshooting |
| 2592 | Jim | 01/03/2025 | 18198 | - cut out and replaced two lobby floor tiles and grouted
- installed wall trim piece over damaged FRP
- remounted corner baseboard by sink and grouted
- cleaned and grouted kitchen floor tiles by fry hopper |
| 2591 | Brendan | 01/02/2025 | 10544 | -repaired dt window: chain, cable clamp, microswitch, solenoid
-p400 upgrades on 4 kiosks
-dt fridge NTF
-OJ NTF
-ordered rebuild kit for dish sink valve |
| 2590 | Waylon | 01/02/2025 | 00596 | Coffee brewers NTF
-reprogrammed cabinet
-bump bar cable fixed and tested
-oven new switch ordered
-fridge hole can’t weld or it will burn up I think didn’t try the metal is just very slim so instead used epoxy to fill the area and made it look like it’s part of it |
| 2589 | Jim | 01/02/2025 | 10622 | - trouble shot men’s room faucet
Brendan is picking up part will install tomorrow |
| 2588 | Brendan | 01/02/2025 | 25383 | -fryer computer was just frozen, just had to be turned off and on again… |
| 2587 | Jim | 01/02/2025 | 18198 | - replaced wall outlet in kitchen as it fell apart when I removed the cover plate
- replaced floor tile by registers and grouted
- spoke to Drew about FRP replacement and he said I could use a wider trim piece to cover damaged strip of existing FRP
I will source and install tomorrow 01/03/24 if possible |
| 2586 | Waylon | 01/02/2025 | 07417 | -swapped outlet for fridge in grill and moved to new spot
-pickup palm pilot
|
| 2585 | Brendan | 01/02/2025 | 02830 | -hic water NTF |
| 2584 | Brendan | 12/31/2024 | 04205 | -shake machine issues, just needed the nozzles to be cleaned
-middle vat in grill would drain to pan, clogged due to lack of cleaning. Unclogged all set
-troubleshooted middle fry vat. Not getting pilot light, will call for warranty service when they open on friday |
| 2583 | Waylon | 12/31/2024 | 25383 | -office light ballast
-UhC switch |
| 2582 | Brendan | 12/31/2024 | 02830 | -replaced AIF probe left fry vat
-troubleshooted ped13, plugged into wrong network port |
| 2581 | Waylon | 12/31/2024 | 18198 | -Had to snake urinal take off the wall and reline pipes and pipe and dope |
| 2580 | Waylon | 12/30/2024 | 07194 | -This was the definition of a pain in the ass fry station that I just fixed the opposite side broke so first step was found the broken wire and bad socket replaced both then it kept tripping the breaker so reopened found a switch stuck open 24/7 went to store bought new switch replaced worked for a little tripped again found another bad socket ohmed out was reading faulty then tripped again was like how literally how started going through every wire redid multiple connections and nothing was shorted then finally noticed the clearance of the sockets to the roof the terminals were hitting and shorting from that so multiple things broke one after another taped over the wires working at the moment gonna throw nuts as a buffer on the rods for a long term fix
Installed new cabinet switch |
| 2579 | Waylon | 12/30/2024 | 10544 | -installed new motor for grill 3 left motor that part wasn’t bad another problem came up the platen was sticking which is a grease shield problem so had to find out which one ended up being front one sprayed down with lubricant and had to retake apart front one and scraped both sides screw back together
-Ordered parts for lobby blinds new gears
-Sink looked at leak not significant at all like a drip I think the goal is to just get it by till we do the new dishwashers |
| 2578 | Brendan | 12/30/2024 | 10622 | -repaired right lobby Coke valve
-p400 upgrades, still need to do two kiosks since the brackets are backordered |
| 2577 | Brendan | 12/28/2024 | 21582 | -emergency call broken water line flooding stockroom. Repaired all set |
| 2576 | Brendan | 12/30/2024 | 04956 | -replace faulty breakfast cabinet controller
-troubleshooted kiosk8 screen. The screen itself is bad, have to have par come out to swap
-pos1 just needed a reboot
-fixed cameras not showing up after power outage
-rbd |
| 2575 | Brendan | 12/27/2024 | 18198 | -was called for door not latching, it latches fine just need to shut it harder because the weather stripping is tight
-installed replacement bump bar side 2 breakfast |
| 2574 | Waylon | 12/27/2024 | 17371 | -Installed fryer board other was intermittent so gonna test new see if problem rolls over or not keeping old
-Fixed muffin toaster working and tested |
| 2573 | Jim | 12/27/2024 | 00596 | - filled all kitchen drains with water to make sure the traps were full to make sure the smell was not from a dry trap.
Also plunged men’s room toilet and cleared drain
All set |
| 2572 | Brendan | 12/27/2024 | 04956 | -FFLS and walk in power just breakers turned off |
| 2571 | Jim | 12/27/2024 | 18198 | - replaced light lens in stock room area
- welded, drilled, tapped and installed new adjustable legs for broken lobby bench
- cut and installed new egg crate vent cover above shake machine
- coordinated with Alan to have all scrap metal removed from corral
Just had him check with Brendan about simplified bun rack |
| 2570 | Brendan | 12/27/2024 | 02830 | -repaired all vats, all vats now working |
| 2569 | Waylon | 12/27/2024 | 02830 | Helped Brendan install new heating element |
| 2568 | Brendan | 12/26/2024 | 04205 | -water survey
-removed broken walk-in camera |
| 2567 | Brendan | 12/26/2024 | 25383 | -replaced middle fry vat computer
-replaced RO pump and fittings, no more leak
-ordered UHC switch |
| 2566 | Jim | 12/26/2024 | 18198 | - cut and replaced four lobby ceiling tiles
- replaced weatherstripping on delivery door
- filled all holes in kitchen walls
- grouted baseboard tiles by delivery door |
| 2565 | Brendan | 12/26/2024 | 04956 | -replaced FCB transducer board and put back in service |
| 2564 | Jim | 12/26/2024 | 00596 | - tightened last table legs all completed |
| 2563 | Brendan | 12/23/2024 | 17371 | Flood |
| 2562 | Waylon | 12/23/2024 | 07194 | -What a day grill needed new thermal couple only took like 2 weeks to come in and had to take off all the panels run the new wire through the platen and down then test
-Ice machine was having a problem was timing the cycles between freeze and harvest after a little bit of the same error was thinking a refrigeration problem but then stopped having an issue eventually I looked inside the evaporator found a massive chunk of ice build up which was causing the ice to not fall into the bin and was what I believe is the source of the problem waited for it to make a lot more ice and has been working since
-Ice machine needs PM
-Grill needs new wheels |
| 2561 | Jim | 12/23/2024 | 18198 | - replaced base tiles by rear door
- replaced base tiles by ladder
Did not grout as glue was very cold from being in truck and want it to harden before grouting
- installed screw in Honeywell box in kitchen |
| 2560 | Jim | 12/23/2024 | 10622 | - tightened men’s room faucet
- re attached kitchen sink spray pipe to wall and tightened faucet nuts to stop leak
- replaced hand soap dispenser by office hand sink |
| 2559 | Jim | 12/23/2024 | 00596 | - drilled and set studs in epoxy, needs minimum 15 hours to harden, then can be tightened.
Will return Thursday 12/26 to complete |
| 2557 | Brendan | 12/21/2024 | 07194 | -emergency call ABS, but working perfectly fine NTF
-noticed leaking under ABS though, cracked drain pan. On order |
| 2558 | Brendan | 12/21/2024 | 04956 | -replaced FFLS touch screen |
| 2556 | Brendan | 12/20/2024 | 04956 | -troubleshooted FCB. Bad transducer board. On order. Not sure how it only broke after Ken’s did their PM…
-installed HDMI extension for camera system
-hooked up speakers to amp
-troubleshooted fryer apparently low temping. Checked contactors and elements which checked out fine. Dropped basket of nuggets and gave no alarm or anything. NTF
-installed replacement stool foot |
| 2555 | Brendan | 12/20/2024 | 02038 | -troubleshooted OJ coming out watery. Just a bad bag. Cleaned nozzle too
-troubleshooted fax, no dial tone even when hooking up telephone. Something wrong on the ISP side of things |
| 2554 | Brendan | 12/20/2024 | 25383 | -troubleshooted fryer, needs new computer, on order
-troubleshooted leak on RO, needs new pump, on order |
| 2553 | Jim | 12/20/2024 | 00596 | - worked in tables in lobby, have eight studs epoxied in the floor,
Need to drill tiles for second table and set last eight studs for that table.
|
| 2552 | Brendan | 12/20/2024 | 02830 | -troubleshooted middle fry vat constantly high temping. After going on a goose chase it turns out the element was the wrong part for this fryer… thanks Casco… new element on order. Temp probe was also jumpy, cleaned up connector and spread its pins to make better connection
-looked at grill fryer filling the wrong vats, filtered some vats with no issues NTF
-kitchen fryer 1 constantly complained of low oil level even when full. New probes on order |
| 2551 | Waylon | 12/20/2024 | 17371 | -Diagnosed muffin toaster looks to be a bad relay going to order
-Two water lines were light clogged j think just tested water and started working for frappe machine and simplified breakfast cabinet
-Fryer heater up vat 5 perfectly fine checked board lights looks all good issues seems to be super intermittent and don’t wanna just throw parts at it had them cook 2 things and watched the temp go up and hit limit and turn off perfectly |
| 2550 | Jim | 12/19/2024 | 00596 | - removed two lobby tables and retitled four floor tiles w/grout
- installed new window sill and apron
- filled holes in partition wall, still need to color match after it dries |
| 2549 | Waylon | 12/19/2024 | 18198 | Right Grill PM |
| 2548 | Waylon | 12/18/2024 | 02830 | -Installed woman’s bathroom solenoid and tested
-Ice machine abs not making ice really really hard to get to control board so had to unplug it and pull all the wires out then ran into and went on the roof to make sure everything was good with the condensers made about 4 sheets of ice for me told them to keep an eye on it but roof was cleared contactor tested fine switch was working to power contactor it was pulling in compressor turning on I believe there’s a time delay on the fan so that turns on at a certain psi after the compressor which it did |
| 2547 | Jim | 12/18/2024 | 00596 | - worked on the remodel of lobby |
| 2546 | Waylon | 12/18/2024 | 18198 | -Installed new dt side door lock after having to cut it with the angle grinder to get it to the right size 😐 got it and then took me a little bit to realize that it has to be put into the latch a certain direction for it to open and close properly anyways made 12 new keys gave them to Jamie and tested alk the keys |
| 2545 | Waylon | 12/17/2024 | 00596 | -installed new temp probe still kept heating up tested contractor looked good still had trouble getting to it and it wouldn’t be heating if it was a bad element so Brendan and I are thinking Casco wired the inside wrong since one contactor is always pulled in we think Casco wired part of it to the wrong contactor which causes it to always heat so we have to go in and check all the wires in the box |
| 2544 | Waylon | 12/17/2024 | 18198 | Abs drain clogged and cleared ended up being a large cup |
| 2543 | Jim | 12/16/2024 | 00596 | - removed 4 benches and two table tops, also 4 embedded posts. Removed 7 damaged floor tiles and replaced with new floor tiles and grouted |
| 2542 | Waylon | 12/16/2024 | 10544 | Repaired dt door screws were bent from people yanking on the door so got new long screws so they can’t slip out loctite on the screws so once that dries they can’t wiggle out and I did a back layer of epoxy where the lock meets the door frame |
| 2541 | Waylon | 12/16/2024 | 07194 | -Fry station half of the bulbs were out inside had a broken neutral terminal which is what kept those two bulbs together so installed a new socket and ran a new glass wire line old wire was melted
-back door detex tamper screw was loose and tested
-Still waiting on grill part parts town only says in process |
| 2529 | Jim | 12/11/2024 | 02038 | - replaced lobby slop sink door slab
- re fastened deliver door handle
- replaced slop sink soap dispenser |
| 2540 | Brendan | 12/13/2024 | 21582 | -replaced bulk coke pressure relief
-couldn't find door handle, had to re order
-searched and ordered splash caps for fryers and lamp guard |
| 2539 | Jim | 12/13/2024 | 10544 | -plunged drain and adjusted water flow for men’s room urinal |
| 2538 | Jim | 12/13/2024 | 07417 | - replaced baseboard tile by office and grouted
- repaired chip in lobby tile
-filled sidewalk cracks
- re fastened ceiling vent in ladies room toilet |
| 2537 | Brendan | 12/12/2024 | 07417 | -hunted for co2 leak, of course I found it on the very last thing I checked. cap for test fitting behind tea brewer causing it to leak
-replaced water QDC fitting for frappe machine that would not auto shut off |
| 2536 | Waylon | 12/12/2024 | 02830 | -Re diagnosed the toilet women’s room problem was a bad solenoid
-Also looked at fryer after Casco insane quote I’m leaning towards more of a temp probe problem so order one of those contractors look fine couldn’t test heat contactor cause how the fryer is set up would’ve had to move fryer out and take up the way mid lunch so not ideal |
| 2535 | Brendan | 12/12/2024 | 00596 | -manchester waterworks survey
-replaced PED15 and paddle
-fixed pos1 BSOD |
| 2534 | Brendan | 12/12/2024 | 04956 | -looked at roof leak in women’s stall near exhaust vent. Went up on roof and found the fan not even running. Called Rick for it, if the water isn’t from the unit I’ll call the roofers |
| 2533 | Brendan | 12/12/2024 | 18198 | -looked at shake machine, Taylor issue under warranty
-checked out roof leaks, calling roofers |
| 2532 | Waylon | 12/12/2024 | 18198 | -Lovby curtain took apart guess was half hanging and they just pulled the rest out (definitely wouldn’t advise this) in doing that they snapped a part of the gear and now we have to order a gear |
| 2531 | Jim | 12/12/2024 | 21582 | -snaked slop sink drain found small amount of hair poured degreaser in drain, let it sit for 15 minutes, then tried one kitchen sink half full and it started to come out of copper wall drain and from under slop sink
- re connected prep sink drain pipe by chicken fryers |
| 2530 | Waylon | 12/11/2024 | 10622 | Installed men’s room toilet button
-Installed new water pump for ice machine
-Ice machine pm literally scrubbed it for hours because of the hard water it still doesn’t look that great but not the end of the world ran two cleaner cycles through it for extra cleaning and a sanitizer cycle threw it then cleaned the whole bin out waited for a couple runs of ice to be made melted the ice to make sure no cleaner got in any ice and told them to give it some time to make ice |
| 2528 | Waylon | 12/11/2024 | 17371 | -Finished probe install for fryer they’re waiting for rti to fix their motor so can’t fill vat and test
-Looked into frappe machine leak honestly looks more like normal operation cause it’s tilted back so it drains properly and never overpools so looks reasonable to me |
| 2527 | Jim | 12/11/2024 | 12272 | - replaced back door weatherstripping
- snaked and poured drain cleaner down lobby drink station, ran the ice machine to drain, all clear |
| 2526 | Jim | 12/11/2024 | 21582 | - checked all three sink drains and pipes and found no leaks , verified with amber in store
|
| 2525 | Waylon | 12/10/2024 | 17371 | -Installed new sprite pump
-Installed new fryer probe missing a pin pusher for it to connect in so ordered that but all the hard stuff is done just needs to be connected
*ordered pin pusher* |
| 2524 | Brendan | 12/09/2024 | 04956 | -network rack install, and unifi install. Whatttttt a torturous task, can’t wait to do 13 more🫠
+5.5hrs differential |
| 2523 | Brendan | 12/09/2024 | 10544 | -troubleshooted dt window, needs many parts, will order
-replaced broken card reader and paddle |
| 2522 | Brendan | 12/09/2024 | 12272 | -installed cutter cover cbb printer
-installed screws for detex |
| 2521 | Brendan | 12/09/2024 | 10622 | -troubleshooted kitchen ice maker, definitely bad water pump. Has very little flow even with distribution tube off and cleaned, on order
-troubleshooted lobby ice maker, reset and it made 6 batches perfectly fine and freeze/harvest times were good
-troubleshooted men’s toilet flush issues. Manual override button missing and stuck down, on order
-replaced dt present bump bar |
| 2520 | Jim | 12/09/2024 | 02830 | - installed new doorbell
- replace two light lenses in kitchen |
| 2519 | Jim | 12/09/2024 | 07417 | - sourced and installed stainless steel panels around meat freezer
-Tightened water line to hand sink by kitchen sink
-installed vent cover on double fridge
- cut and installed threshold in walk in side of freezer
- replaced two wall tiles by office |
| 2518 | Waylon | 12/09/2024 | 07194 | -Came to put in a new thermal couple for grill took of half the grills covers removed motor harness finally got to the bad thermal couple cut it and unscrewed but when trying to install the new one noticed it was the wrong one so I dropped the ball I typed one wrong number on parts town so got a thermal couple for a different grill ordered new one left out motor harness so install will be easy and fast when part comes in got half the hard stuff done |
| 2517 | Jim | 12/06/2024 | 07417 | - PM, ed ice machine |
| 2516 | Brendan | 12/06/2024 | 02038 | -gave store replacement iPad that they dropped in the fryer and showed how to use
-repaired leak on waterline for breakfast cabinet
-troubleshooted lobby ice maker issues, both roof issues, i called Rick to fix |
| 2515 | Jim | 12/06/2024 | 00596 | - replaced batteries in ladies bathroom large toilet
- PM’ed ice machine |
| 2514 | Waylon | 12/06/2024 | 18198 | -Finished tracing electrical issue for plug ended up being a wire nut in the oep box then added all new screws for the box since it was barely holding up
-Took fried mouse 🐀🐀 out of breaker panel took a little bit homie was curled in between wires
-took old taper screws out of shelf in wall and replaced with new wall anchors |
| 2513 | Waylon | 12/05/2024 | 07194 | -Grill bad thermal couple top back ordered parts
-Gapped left tplaten on grill and tested quarter temps |
| 2512 | Brendan | 12/04/2024 | 04956 | -replaced cabinet temp probe fry freezer |
| 2511 | Jim | 12/04/2024 | 25383 | PM’ ed ice machine, very dirty |
| 2510 | Brendan | 12/04/2024 | 02830 | -right grill cert
-replaced grill vat 3 linear actuator |
| 2509 | Waylon | 12/04/2024 | 02830 | -Pm right grill
-Replaced 2 motors right platen only one was bad and the other was on its way out but had to take out the motor harness so just replaced both all new motors in that platen within last 2 months |
| 2508 | Jim | 12/04/2024 | 10544 | - deep cleaned ice machine and PM’ed also
- present window, need new chain and related parts, had to reinstall right side wheel and guide bar for window to operate correctly
|
| 2507 | Brendan | 12/03/2024 | 04956 | -tech rack install/assembly. Will return on a night for the overnight work part |
| 2506 | Waylon | 12/03/2024 | 04956 | Helped build the tech rack and go over plans |
| 2505 | Jim | 12/03/2024 | 12272 | - replaced two lobby ceiling tiles above registers
- PM ‘ed ice machine |
| 2504 | Waylon | 12/03/2024 | 18198 | -installed a new wheel for track system inside of window
-Installed new outlet for new breakfast cabinet
-Did half the diagnosis for a plug it’s not receiving one phase of power and it’s receiving it at breaker panel so gotta do some searching in the ceiling and need to switch off like 6 breakers of equipment so that’s waiting for tmrw morning early ish |
| 2503 | Jim | 12/03/2024 | 02830 | - replaced men’s room lock
- checked ladies room toilet flush control, need new internals, on order
- PM’ed ice machine |
| 2499 | Jim | 12/02/2024 | 04205 | -sourced and replaced hot and cold faucet handles and cartridges
- did PM on ice bin |
| 2502 | Brendan | 12/02/2024 | 17371 | -replaced pos1
-repaired leak on water booster, bypass valve cracked
-replaced muffin toaster probe 1+2
-troubleshooted fryer more, temp probe is a bit slow I suppose, will order and hope that fixes
-noticed help button on kiosk 7 stuck down, unplugged and will order replacement |
| 2501 | Waylon | 12/02/2024 | 12272 | Grill call went in first thing I checked was voltage at contractor not there checked plugs was unplugged so beyond stupid call waste of my time waited for it to heat up and did temps on 10:1 and quarter all came back good |
| 2500 | Waylon | 12/02/2024 | 00596 | Hlz no power tested blown fuse replaced ran up to temp then waited a little and let them use it to see if the fuse would blow again did not blow |
| 2498 | Waylon | 12/02/2024 | 07194 | -Fryer new cord 6 gauge then had to drive half an hour to get a o ring terminal for the ground since I couldn’t splice the new and old due to the wires being to big and typical don’t work on awg 6 so don’t have any terminals but I do now
-fixed ladies room door latch hanging
-picked up window parts for lee |
| 2497 | Jim | 12/02/2024 | 02038 | - replaced rubber hose on water supply to sink soap dispensers
|
| 2496 | Brendan | 12/01/2024 | 02830 | -lobby leak NTF
-dt runner bump bar NTF
-replaced filet steamer OEP
-troubleshooted vat 3 not holding oil, needs new linear actuator, will order |
| 2495 | Brendan | 12/01/2024 | 10544 | -replaced pos1
-cleaned out my boxes
-replaced top trip on ice machine
-installed replacement beef drawer handle, had to drill larger and install rivet nuts since the threads were also missing
-bun steamer breaker just tripped, working fine
-rbd |
| 2494 | Brendan | 12/01/2024 | 07194 | -frappe machine had two leaks, had to replace water QDC and cleared drain pan
-took pictures of menu board that was shot so strata can come out |
| 2493 | Brendan | 12/01/2024 | 04205 | -strawberry syrup not pulling, yes it is, making strawberry shakes just fine. NTF
-repaired lobby rootbeer valve |
| 2492 | Brendan | 12/01/2024 | 21582 | -checked out co2, everything working properly just a bad gauge |
| 2491 | Brendan | 11/27/2024 | 04956 | -replaced Coke Zero bib pump |
| 2490 | Brendan | 11/27/2024 | 21582 | -installed replacement pos1 |
| 2489 | Brendan | 11/27/2024 | 07194 | -internet issues. Appeared to be a bad network switch, called ATT to have them replace. Proceeded to spend hours doing extra unnecessary troubleshooting just for them to arrive at the same conclusion…. They will be here Saturday to replace.
-troubleshooted and replaced dt window 2 motor |
| 2488 | Jim | 11/27/2024 | 07417 | - re wrapped water line to OJ machine with insulation
- re did concrete work on drive thru side walkway
- replaced egg crate vent cover by bathrooms |
| 2487 | Jim | 11/26/2024 | 02830 | - sourced and replaced washing machine
|
| 2486 | Brendan | 11/26/2024 | 12272 | -troubleshooted breakfast cabinet, bad motor bearings, replaced motor
-all grill platens were working upon arrival NTF |
| 2485 | Brendan | 11/26/2024 | 18198 | -ran wire and installed breakfast cabinet. Luckily didn’t have to fix any of Ken’s leaks today! However they didn’t order the bun rack kit so we are stealing that from Alton. Also need to order OEP since that also comes with the bun rack kit.
-Troubleshooted ceiling leak, pipe burst for roof hydrant, just turned it off for now since it is going into winter, will repair in the spring
-troubleshooted dt window, bearing pretty stiff, will order
-replaced bulk coke tank connector and o-ring |
| 2484 | Jim | 11/26/2024 | 10622 | -Worked on removing clog on chicken vats drain pipes, got it cleared and tested drain and fill, works fine now
|
| 2483 | Brendan | 11/25/2024 | 17371 | -replaced cracked water line in coffee brewer
-replaced two microswitches in lobby valves
-replaced muffin board control board
-swapped fryer computers around to see if issue follows
-looked at lobby ice machine, curtain got stuck down. Cleaned and put back hopefully that’ll last |
| 2482 | Waylon | 11/25/2024 | 02830 | -Washing machine agitator scraping metal on metal inside it basically a death sentence a new agitators cost more than half of a new one would also struggle to even start the agitator up and when it did metal was scraping
-Filet steamer with no power the oep is destroyed and burnt up prong and the outlet is half blow up so ordered both of those |
| 2481 | Waylon | 11/25/2024 | 12272 | -Platen 1 raising slowly normally it’s the pneumatic lines ended up being the cylinder so had to take the cylinder out and do a rebuild on it took forever and was awful
-Took the freezer doors off the list because it opens and closes perfectly fine for me and stays closed |
| 2480 | Jim | 11/25/2024 | 02830 | - repaired sidewalk crack
- checked washer could not replicate issue |
| 2479 | Brendan | 11/25/2024 | 10622 | -replaced lobby door dogging mech
-troubleshooted grill vats not filtering oil, I scoped it and found a napkin packed in a 90° fitting. Was unable to remove with hook attachment, will be back tomorrow to remove fitting to clean out
-troubleshooted monitor screen discolored. Bad wire in the ceiling, will replace another time |
| 2478 | Jim | 11/25/2024 | 17371 | -repaired lobby chair
- grouted in front of fry vats and sink |
| 2477 | Brendan | 11/25/2024 | 00596 | -lobby door not latching, moved latch lower and out all set |
| 2476 | Brendan | 11/25/2024 | 02038 | -replaced carb water flow control spring ABS
-measured and ordered lobby maintenance door and laminate |
| 2475 | Waylon | 11/25/2024 | 18198 | -Regung shelf that fell out of wall
-Adjusted muffin toaster quality
-Saved Jim from locking himself on the roof lmao |
| 2474 | Jim | 11/25/2024 | 18198 | - replaced roof hatch handle and latch |
| 2473 | Jim | 11/25/2024 | 07417 | - tightened “J” bolts in overhead to not allow any space for sign clips to pop off in the wind on windows one and two |
| 2472 | Brendan | 11/22/2024 | 04956 | -replaced McFlurry spinner switch |
| 2471 | Brendan | 11/22/2024 | 02830 | -replaced fc runner monitor
-noticed that side 1 breakfast monitor was discolored, and would flicker off if touched. Replaced VGA cable to fix
-noticed pos1 BSOD, all fixed
-noticed ped7 froze, rebooted |
| 2470 | Brendan | 11/22/2024 | 25383 | -troubleshooted fry hopper no power. Cord broken, had to go to the store and replaced.
-got kiosk 6 printer door unstuck |
| 2469 | Jim | 11/22/2024 | 07417 | - cemented sidewalk on drive thru side to eliminate tripping hazard
- made and installed cover for electrical access on light pole |
| 2468 | Jim | 11/22/2024 | 02038 | - replaced sink strainer and both pipes to fix leak
- checked delivery door, found no issues and talked to maintenance man seems to have fixed itself
- tighten door frame in lobby maintenance closet , needs new door slab to close properly |
| 2467 | Waylon | 11/22/2024 | 02038 | -Extended bum toaster cord and zip tied all the cords down to look neat
-angle grinded lock off the safe Kristin said she would replace lock since they lost the key too it
Did not get to do the orange outlet since got here too late to shut the computer system down to do it |
| 2466 | Jim | 11/22/2024 | 25383 | - cut and installed two pieces of Formica on lobby partition |
| 2465 | Jim | 11/22/2024 | 04205 | - cut and replaced weatherstripping on trash door |
| 2464 | Jim | 11/22/2024 | 00596 | - measured and figured I need 30 floor and wall tiles in the MCD approved substitute tiles Color: Cloudsky and I need 10 of the dark grey tiles to add baseboard to where the wall mounted benches are.
The partition has Formica |
| 2463 | Brendan | 11/21/2024 | 07194 | -got power switch from Lowe’s and replaced fried product freezer switch
-stopped at Londonderry to pickup sundae side freezer door to drop off |
| 2462 | Waylon | 11/21/2024 | 18198 | -added McRib to their menu on UHCs |
| 2461 | Waylon | 11/21/2024 | 02038 | -Disassembled and reassembled filet steamer to replace the whole cord so it’s now long enough to reach plugs
-removed old and installed new cord for muffin toaster so it can reach plugs |
| 2460 | Jim | 11/21/2024 | 21582 | - purchased and installed new cam lock set for toy display |
| 2459 | Brendan | 11/21/2024 | 02038 | -co2 issue. Looks like coke messed it up, had to correct pressure back up to 105psi, was set to 70 |
| 2458 | Jim | 11/21/2024 | 25383 | - re built backflow preventer by main sink
- installed new ballast in crew room light
- replaced top bulb in simplified cabinet ( put extra bulbs in left upper cabinet in office, in a white three drawer case )
- installed breaker lock on panel PL-1 # 16, always on
- replaced emergency light in vestibule on Drive thru side
|
| 2457 | Brendan | 11/20/2024 | 10544 | -troubleshooted OJ not dispensing, managed to get it working but noticed a leak coming from the CFV. took out dispense platform, cleaned out molded interior and platform and unclogged drain. ordered new fitting |
| 2456 | Brendan | 11/20/2024 | 12272 | -breakfast cabinet install/electric. Had to fix Ken’s leaks again
-replaced bun toaster oep with 4 pin |
| 2455 | Jim | 11/20/2024 | 12272 | - re routed water line in ceiling to extend to simplified breakfast machine
- replaced and grouted five floor tiles by present window
- adjusted and re installed light shroud above lobby drink station |
| 2454 | Waylon | 11/20/2024 | 17371 | -Muffin toaster had the same problem again no definite way to say it’s thermocouples or the board so gonna order both
-Installed new oep for old egg cooker outlet
-Looked at fryer staying heated checked with temp probe turned off back on and went back to being normal |
| 2453 | Jim | 11/20/2024 | 02038 | - tightened hand sink drain pipe by office
- replaced one small table in play place ( large top came with the small one but there are no large table tops that need to be replaced in the play place, and the top is rounded more then the tops in the lobby. I left the extract top in the store by the ice bin
- replaced four legs on the front unit by the landing zone area
|
| 2452 | Waylon | 11/20/2024 | 18198 | -Abs ice machine massive build of ice tried to force a harvest cycle wasn’t getting any hot refrigerant to the evaporator to melt the ice off notified Rick since nothing I can do about it only 2 weeks into class lmao |
| 2451 | Brendan | 11/19/2024 | 04205 | -repaired bricked frappe machine and upgraded
-replaced dead cbb monitor |
| 2450 | Jim | 11/19/2024 | 18198 | - re fastened FRp to wall by drive thru one
- replaced base tile by walk in and grouted |
| 2449 | Waylon | 11/19/2024 | 02038 | Installed 2 cabinets… |
| 2448 | Brendan | 11/19/2024 | 02038 | -installed two new cabinets, scrapped old 3 cabinets for parts. What a hassle. Need to order new brackets though because the old ones aren’t compatible. Had to extend cords for printer/bump bar to accommodate shortening the line. Will need to extend OEPs another day.
-replaced faulty GFCI in prep line
-replaced ABS touch panel
-troubleshooted grill vats not disposing, the key for the fill/dispose switch got turned off lol |
| 2447 | Brendan | 11/18/2024 | 21582 | -troubleshooted melitta but of course while I was in the middle of it McD recalled all the machines lol
-McFlurry mixer NTF
-pos1 issues |
| 2446 | Jim | 11/19/2024 | 04205 | - grouted along top of baseboard tiles behind frappe machine and and smoothie machine too |
| 2445 | Jim | 11/19/2024 | 00596 | - no sewage smell upon arrival, spoke with Jessica and she said she sprayed and it went away
- straightened electrical panel in grill area and epoxied to post in floor
- re hung crew room coat hanger
- replaced clip on top connector of flag pole, to hold flag properly |
| 2444 | Waylon | 11/18/2024 | 00596 | -Installed new switch in cabinet
-Grill middle platen was not heating up in a timely manner checked plugs and did a little diagnostics but it’s under warranty most likely thinking bad relay or thermal couple but under warranty so Taylor called
|
| 2443 | Brendan | 11/18/2024 | 04205 | -troubleshooted frappe machine, really weird issue tried reloading sd card but still a no go. According to the flow chart needs a new touch screen, so ordered new touch screen and sd card and blender pitcher |
| 2442 | Waylon | 11/18/2024 | 10622 | Stopped in assumed it was a bump bar cable but sounds like soda was dumped on it which means board is most likely fried so ordering a new one and giving bump bar to Brendan to see if he can fix |
| 2441 | Brendan | 11/18/2024 | 12272 | -register working upon arrival NTF
-replaced push bar end cap
-reset tripped GFCI for McCafé fridge |
| 2440 | Waylon | 11/18/2024 | 17371 | -Looked at muffin toaster message was a thermocouple problem but when I walked in the toaster was in use either way still looked at it ohmed out thermo couple didn’t find any problems with it then also checked all the heated wires also found no problems
-Cream dispenser cleaned up all the solenoid and plunger dissembled and reassembled and worked like a gem
-ordered oep to store
-Took pictures and looked into possibly adding another outlet per Ty’s request |
| 2439 | Brendan | 11/15/2024 | 02830 | -ketchup dispenser line pinched shut on landing zone
-replaced oven controller |
| 2438 | Brendan | 11/15/2024 | 18198 | -someone accidentally popped the drives on the server. Had to rebuild raid |
| 2437 | Jim | 11/15/2024 | 10544 | - checked exit sign, found loose connection at sign, all fixed
- repaired two fence posts, fence is nearing its end of life stage |
| 2436 | Waylon | 11/15/2024 | 07417 | Side of abs put a screw in to keep it on
1 cabinet strip bottom row middle cabinet
Removed old co2 central unit covered with a blank outlet cover |
| 2435 | Waylon | 11/15/2024 | 00596 | Originally had a ticket for the grill having a probe failure Brendan told them to check the plugs Wednesday and they said they were too busy and would let him know on Thursday never heard back from them so came out here just incase so they didn’t go into the weekend without a platen but got here and it’s all set was a plug problem they just didn’t text us back 💀 |
| 2434 | Jim | 11/15/2024 | 07417 | - re laminated first stall door in ladies room and tightened hinge screws
- ice bin was frozen so I set it to clean and cleared blockage, then powered off and on to reset system |
| 2433 | Waylon | 11/15/2024 | 18198 | -Haven’t gotten stumped in a while tbh so for lees window diagnosed with bad motor since it was detecting current which replaced motor today the window closes almost all the way instead of at the half point but there’s still a gap, Brendan’s spent more time on the windows this is like my second time ever so I asked him to take a look and see if I messed something up or if the board is bad cause it’s detecting current and the sensor works and it’s hitting the micro switch in the back so only thing I can think about is a board problem or the track |
| 2432 | Brendan | 11/14/2024 | 07417 | -installed mirrored bake monitor |
| 2431 | Brendan | 11/14/2024 | 04956 | -troubleshooted melitta. ACS was way off calibration so I fixed that. Does seem to need a PM though so I will order a kit
-troubleshooted shake machine. Freezing up again. Am going to put a new viscosity sensor in |
| 2430 | Jim | 11/14/2024 | 18198 | - cut and installed baseboard tile by delivery door and grouted
- installed new safety bar on roof access ladder
- egg crate vent cover completed on arrival |
| 2429 | Brendan | 11/14/2024 | 02038 | -ABS conveyor stall, adjusted sensor all set. Also noticed it was pulling 4 small cups at a time so adjusted the fingers
-cabinet not turning on, replaced switch all set |
| 2428 | Jim | 11/14/2024 | 07417 | - installed two new hand sanitizer dispensers at hand sinks
- cut and replaced Formica on two lobby drink station doors
- installed shut off on water line to sink dispensers
- cut and installed base tile by slop sink door |
| 2427 | Jim | 11/14/2024 | 00596 | - measured for the new piece of corian for window sill, Counter Pros
Manchester, NH Color: Dove 11’ long , 4 3/4 “ wide, 1/2” thick with round over edge on one long side |
| 2426 | Jim | 11/13/2024 | 10622 | - re set latch on delivery door |
| 2425 | Brendan | 11/13/2024 | 07417 | -p400 upgrades, replaced 6 |
| 2424 | Waylon | 11/13/2024 | 07417 | -Installed 6 new cabinet strips had to readdress two cabinets multiple times then had to reprogram cabinets multiple times ran into a broke display board in one of the slots had to go to office to get one and then install that and replace the strip on that
Anyways all cabinet strips working there’s 1 left on the middle cabinet bottom slot that looks like it’s on its way out but I’ll replace closer to RGR time since it works at the moment |
| 2423 | Brendan | 11/13/2024 | 17371 | -troubleshooted coffee brewer smelling like electrical burning and not powering on. Transformer on board died, replaced board and calibrated
-noticed hot water valve on right coffee brewer was loose and not working well. Installed repair kit and tightened
-recrimped two bump bar cables💀
-adjusted hinge of espresso milk fridge to get rid of gap
-reimaged pos1
*measure 51” clearance for DAC and juice cart* |
| 2422 | Jim | 11/13/2024 | 25383 | - replaced men’s room faucet with hands free unit
- shimmed corral wall all set
- removed conduit and electrical box and light from corral ( old compactor power) and capped stub
|
| 2421 | Jim | 11/13/2024 | 10544 | - snaked drain and went five feet, drain runs good now
|
| 2420 | Brendan | 11/12/2024 | 07417 | -replaced kiosk7 printer door
-troubleshooted OJ not dispensing water, bad dispense valve, replaced all working |
| 2419 | Brendan | 11/12/2024 | 07417 | -wild goose chase for a breaker lock because the goofy fire dept will be back tomorrow |
| 2418 | Brendan | 11/12/2024 | 07417 | -left grill PM |
| 2417 | Jim | 11/12/2024 | 12272 | - re set drive thru curbing |
| 2416 | Jim | 11/12/2024 | 12272 | - re set drive thru curbing |
| 2415 | Waylon | 11/11/2024 | 21582 | -Grill not heating up fully was just a plug problem was not getting 208 between L1 and L2 after originally checking relays cause typical relay problem especially when they told me they checked plug and turned on and off.. |
| 2414 | Waylon | 11/11/2024 | 12272 | -Welded hinge for freezer door made sure I cleaned it up good since it rusted used loctite on the screws hoping that will expand to fill out the area incase the weld rust and I used a little bit of epoxy around the hinge so no water can leak down into it starting rust to form
-Drive thru side push bar was a mess very very old model so had to drill holes for new lock and the metal plate that stops it from sliding off was stuck in a spot it couldn’t stay in since the new lock had to go in so had to break that out and weld it into a different spot and while putting it back together the back handle of the push bar screw broke the plastic so that needs to be ordered but the push bar works opens and closes and locks great gave the new keys to Dawn
|
| 2413 | Brendan | 11/11/2024 | 00596 | -FCB cherry fill error. Erroneous error, did not reappear after resetting
-coffee brewer fill error. After resetting error I literally brewer a dozen pots with no issues
-set pull forward message for cod2 |
| 2410 | Jim | 11/11/2024 | 04205 | - replaced GFCI outlet behind coffee brewer’s
- re installed slat wall behind frappe Machine |
| 2412 | Jim | 11/11/2024 | 02830 | - tried to replicate loud pipe issue to no avail, spoke to Ann and Mary and they seem to be describing a intermittent water hammer.
|
| 2411 | Jim | 11/11/2024 | 10622 | - cut and replaced 8 egg crate vent covers throughout store
- replaced left sink strainer gasket and reinstalled, no leaks
- added three screws to the faucet spray nozzle stand pipe |
| 2393 | Jim | 11/06/2024 | 04956 | - shimmed railing/fence on drive thru side and installed screw
- poured drain cleaner and plunged urinal drains fine now
- re set GFCI and plugged in cord , did not pop seems to operate fine |
| 2409 | Brendan | 11/08/2024 | 10622 | -troubleshooted multiplex. At first I believed it to be the board because it wasn’t sending voltage to the contactor, but then I realized it was the hpco that was tripped but it doesn’t make it throw an error. Rick will have to replace that part. Must’ve failed because it had one bad condenser fan motor. I went to replace it but the one I had on me was broken out of box AGAIN for the second time this month! So Rick will just do that at the same time. Set the pos to dispense lobby drinks at the abs for now until he fixes it next week
-replaced two loose outlets behind OAT |
| 2407 | Brendan | 11/08/2024 | 25383 | -replaced batteries on two emergency lights, struggled so hard to close the enclosure back. One of the emergency lights is dead dead though and needs to be replaced
-replaced exit sign drive thru side |
| 2408 | Jim | 11/08/2024 | 02038 | - repaired hand sink drain by office
- swapped soap dispenser at slop sink |
| 2406 | Jim | 11/08/2024 | 25383 | - cut new light lens for light by prep table
- re fastened diamond plate on wall in
- repaired drive thru side outdoor faucet and siding , and painted
|
| 2405 | Waylon | 11/07/2024 | 07194 | -Installed new temp probe for filet steamer correct diagnosis ran into another problem the wires were so frayed and bent on the relay between switch and board kinda had to mess around with it for a little to get it to work I recommend a new power cord and those lines all ran new in the future |
| 2404 | Brendan | 11/07/2024 | 17371 | -troubleshooted fry hopper not cooling. It was really tricky to trace down but there was a small section of chafed wire so the compressor wasn’t getting any power. Repaired all set
-troubleshooted cream not dispensing, plunger came unscrewed from the pincher, all set
-repaired women’s toilet, replaced override button, controller, and solenoid. Toilet is now finally working |
| 2403 | Waylon | 11/07/2024 | 00596 | Installed new o ring for filter drain was thinking it was gonna be a small o ring easy pop in nope nope it’s massive and connected two massive pipes that aren’t even lined up properly 😭 |
| 2402 | Jim | 11/07/2024 | 00596 | - snaked and plunged men’s room toilet and found yogurt cup lodged in drain |
| 2401 | Waylon | 11/07/2024 | 21582 | -Fry station not working no breakers were tripped tested switch after pulling it out was working and it it per down the whole top found a burned off neutral coming from the main electrical had to remove all the old electrical and put in new cause there wasn’t enough slack to cut back wires then someone wire nutted in it which melted to dust basically so fixed all those wires to just be one cord of glass wire
-grill was working in use when I arrived to store and throughout my time in store |
| 2400 | Jim | 11/07/2024 | 25383 | - replaced four baseboard tiles by hot water tank and grouted
- cut and replaced two ceiling tiles, one above simplified and one in vestibule
- painted and installed five corner guards, one by multi plex and four around post by bulk coke tanks |
| 2399 | Brendan | 11/06/2024 | 25383 | -replaced Qing oven blower motor, cord, OEP plug, and OEP receptacle
-hung clearance bar back up
-wrote out grill cert |
| 2398 | Waylon | 11/06/2024 | 25383 | -finished welding the ice bin cover honestly gave up on it was burning through the metal so it doesn’t look pretty it’s not jagged and snapped off anymore but it’s not pretty the cover is over 25 years old….
-went through qing oven wiring diagram since it was making a weird buzzing noise after Brendan installed the new fan (didn’t have anything to do with the new fan motor) took everything off made sure it was all good tested and noise went away
-fixed outlet cover in crew room
-removed some of corner stripping found we have the wrong one so took pics of spots and Jim’s gonna take care of them with the couple times he has left |
| 2397 | Waylon | 11/06/2024 | 10544 | -Drive thru side push bar originally went to weld trillion holes closed in it but then found the welds weren’t adhering to the door at all then we had to move the whole push bar over to the left so it could probably latch needed to cut the push bar down 5/8 of an inch on the frame and push bar so two very precision cuts and then had to go get a metal bar to push out the closer 3/4 of an inch then cut to fit that install it to the door either way took a long time to fix a push bar but either way it’s fixed and works tested |
| 2396 | Waylon | 11/06/2024 | 10544 | -Drive thru side push bar originally went to weld trillion holes closed in it but then found the welds weren’t adhering to the door at all then we had to move the whole push bar over to the left so it could probably latch needed to cut the push bar down 5/8 of an inch on the frame and push bar so two very precision cuts and then had to go get a metal bar to push out the closer 3/4 of an inch then cut to fit that install it to the door either way took a long time to fix a push bar but either way it’s fixed and works tested |
| 2395 | Brendan | 11/06/2024 | 10544 | -annoying push bar with waylon |
| 2394 | Jim | 11/06/2024 | 07417 | - installed one hand sanitizer on sink by office ( searched the store and shed still need two more)
Replaced J pile on front hand sink leak fixed |
| 2392 | Waylon | 11/06/2024 | 04956 | Diagnosed bad GFCI outlet switched plugs for abs for now don’t have time to replace the outlet behind the coffee brewers would have to turn off probably the whole chassis |
| 2391 | Waylon | 11/06/2024 | 18198 | Walked in instantly asked why the grill won’t come out of auto level I told them it’s probably just unplugged so pulled out the grill plugged it in started to heat up waited for it to get out of auto level and said they are good to use it
-Wish they would’ve texted me at like 5 am so they weren’t down a grill all morning but whatever 😭 |
| 2390 | Brendan | 11/05/2024 | 02830 | -troubleshooted strawberry shake syrup not pumping. Found a few issues. Replaced peristaltic pump tube and a quick connect o ring. Someone along the way had switched strawberry and vanilla syrup lines so the vanilla was the one without the quick connect instead of the strawberry. Swapped back since seeds tend to get stuck in the quick connect. Calibrated both syrups |
| 2389 | Brendan | 11/05/2024 | 17371 | -put parts in toilet flusher, unfortunately the actual problem was the override button magnet fell out and the control box intermittently working. Because of course it’s the less common issues lol |
| 2388 | Waylon | 11/05/2024 | 02830 | Replaced 3 motors in grill 1 platen 1 one motors was dead and two were ok their way out so just max’s the decision to do all 3 instead of going back for another call in like a couple weeks to a month |
| 2387 | Brendan | 11/05/2024 | 10622 | -computer in office not working, found that the USB extender cable went bad. It’s pretty long and I don’t have an extra so I stole the extender from dual point for now |
| 2386 | Brendan | 11/05/2024 | 04956 | -troubleshooted shake machine shake side not dispensing. Believed it to be due to freezing. Viscosity Wes set way too high, lowered that down and verified proximity sensor calibration. Believe it should be okay now |
| 2385 | Waylon | 11/05/2024 | 18198 | -Diagnosed window not working looks to be a bad motor no clear indication signs because it’s doing most of its job but stops a little to early which most of the time means bad motor cause the motor senses current to stop working
-grill not latching problem it was working perfectly fine open closed it about 10 times no problem manager said no problems this morning
- looked into electrical fire in two drawer fridge I couldn’t find anything burnt or charred at all no smoke residue no nothing all wires looked good compressor was working and fan was spinning made sure it go down to temp told them to clean it and run it see what happens |
| 2384 | Brendan | 11/04/2024 | 07417 | -Raymond frappe upgrade. They had micro sd card so I had to go to the store to find one, then it didn’t work so I had to fix the corrupt files so annoying |
| 2383 | Waylon | 11/04/2024 | 25383 | -Installed new electrical was easier than normal cause all we had to do was a run a new line to box and tie everything in and a hole was already made tested and works
-Fixed and diagnosed the qing oven wasn’t heating went in found a blown fuse replaced blew again but that blowing told me what HV system to look into so it was either a bad transformer or a capacitor tested capacitor came back good and transformer was reading a little questionable but wasn’t saying it was dead so ran it a little and transformers have a distinct smell and smelled that so replaced it worked great but while I was in the Qing oven found the blower motor hanging on for dear life it was cracked and very wobbly so ordering a new one and found the cord to be wrapped in electrical tape and a broken oep so ordered all that stuff
-started welding the top of abs cleaned up the two corners that were cracked apart my grinding disc got used up so stopped there welds are in they just aren’t made pretty yet will come back to when I come back for qing oven |
| 2382 | Brendan | 11/04/2024 | 04205 | -replaced ABS breaker
-installed frappe upgrade sd card and gave store instructions when they turn it back on |
| 2381 | Brendan | 11/04/2024 | 25383 | -ran oep circuit to correct panel
-removed breakers for compactor and corral lights so Jim can remove
-noticed dish sink backflow leaking, will order repair kit |
| 2380 | Brendan | 11/01/2024 | 02038 | -updated frappe machine
-replaced emergency light bulb |
| 2379 | Brendan | 11/01/2024 | 10544 | -replaced PW1 solenoid ABS
-replaced remaining condenser fan motor |
| 2378 | Brendan | 11/01/2024 | 25383 | -troubleshooted lane 2 canopy power; checked all the breakers, contactors, electrical boxes and everything but I believe there to be a break in the wire underground
-repaired Coke Zero lobby valve
-troubleshooted shake machine, shake side barrel is freezing. Called into Taylor |
| 2377 | Jim | 11/01/2024 | 10622 | - snaked ladies room toilet found needle flushes fine now |
| 2376 | Brendan | 11/01/2024 | 04205 | -replaced hi-c bib pump
-coffee brewer was working upon arrival |
| 2375 | Jim | 11/01/2024 | 07417 | - replaced two baseboard tiles at delivery door and grouted
- re installed pay here sign, J bolt stripped out |
| 2374 | Jim | 11/01/2024 | 07194 | - replaced what wall tile by prep table and grouted
- replaced three floor tiles by fry vat and grouted |
| 2373 | Brendan | 10/31/2024 | 02830 | -grill working on arrival so will wait for Waylon to get back to switch out motors
-oven NTF
-fixed cameras not showing on app. Something stole its ip |
| 2372 | Jim | 10/31/2024 | 17371 | - replaced delivery door sweep, tightened frame side of closer, and adjusted closer the latch correctly
- repaired crew room chair with parts from third chair , will find proper clamp and install next time I come up |
| 2371 | Jim | 10/31/2024 | 10622 | - sealed sink drain pipe with blue glue, was dripping
- replaced ladies bathroom toilet water valve and flush control valve, flushes better but not as hard as the other toilets
- adjusted closet on drive thru side
-set temp on hand sink and replaced gasket on down pipe lock nut
- re attached blank cover at drive thru 1
|
| 2370 | Jim | 10/31/2024 | 00596 | - sealed plate under hand sink by office, eco lab issue |
| 2369 | Jim | 10/31/2024 | 12272 | - refastened control box at drive thru 2
- refastened FRP at Drive thru 2
- tightened electric eye strip at drive thru 2
-Grouted behind small ladies room stall door |
| 2368 | Brendan | 10/30/2024 | 04956 | -repaired dt window 2, bent metal overlap removed and re-leveled doors, opening size was also set correctly |
| 2367 | Brendan | 10/30/2024 | 02038 | -troubleshooted tea brewer, co2 just got unplugged
-troubleshooted emergency light, blown bulb. Went to auto part stores to buy new set. Butttt silly ole me accidentally bought red colored bulbs. Will bring correct bulb next time
-repaired hand sink pipes leaking |
| 2366 | Brendan | 10/30/2024 | 10544 | -replaced multiplex fan motor. One of the motors had a stuck fan blade that I was unable to get off. One of the new fan motors also arrived defective with its bearing detached, so replacement fan and blade on order. It will cool down with just one it just won’t be very fast
-ABS was unexpectedly a very different issue, CW1 solenoid died so it was only dispensing 20% of the required water. I swapped it out for the plain water solenoid so they could sell sodas normally, just not hi-c. Also changed the armature tips while I was in there. Replacement solenoid on order to fix PW1 valve |
| 2365 | Jim | 10/30/2024 | 04205 | - snaked twenty feet hit nothing plunged and poured a gallon and a half of sulfuric acid into the drain it went down quite a bit.
Told Hope to monitor and call Brendan for advice if it comes back up again |
| 2364 | Jim | 10/30/2024 | 21582 | - unclogged ladies room handicap toilet, by snake and plunging
- fabricated hinged cover for delivery door window |
| 2363 | Brendan | 10/29/2024 | 12272 | -push bar was made before 1995 so apparently has a different style dogging. Was able to order retrofit kit |
| 2362 | Brendan | 10/29/2024 | 00596 | -abs issue just sensor out of alignment. All set.
-coke issue at ABS was just because syrup deflector missing, replaced
-fixed savers entrance can not working, rebooted all set |
| 2361 | Jim | 10/29/2024 | 07417 | - filled sidewalk cracks with poly sand
- replaced 5 wall tiles behind meat freezer and grouted
- replaced two wall tiles at corner by meat freezer and grouted
- filled three potholes in parking lot
- installed covers by ABS and coffee brewers
-installed new cover on light pole by storm drain
|
| 2360 | Brendan | 10/29/2024 | 04956 | -replaced fry freezer power switch and plug |
| 2359 | Brendan | 10/28/2024 | 04956 | -replaced cartridge washers at dish sink
-replaced leaking Dr Pepper nozzle
-troubleshooted fry freezer, bad power switch, on order |
| 2358 | Brendan | 10/28/2024 | 10544 | -troubleshooted melitta. So many issues, bad inlet temp probe, bad milk conductivity sensor, and bad flow meter/harness. On order
-troubleshooted multiplex, two bad condenser fan motors. On order
-troubleshooted front door not unlocking from outside. Due to poor installation, the cylinder stem doesn’t even line up with the push bar mechanism. Will require moving the push bar and latch to the correct position. Will have to order a new cylinder since the stem isn’t long enough, then wait for Waylon to get back since will need welding.
-menu board 2 was off, turned back on
-merge monitor was unplugged, plugged back in |
| 2357 | Jim | 10/28/2024 | 00596 | -helped Tara move security lot monitor to allow the maintenance of the Main Street sign
- sourced and installed new grease interceptor tank along with all plastic plumbing leading to the tank |
| 2356 | Waylon | 10/28/2024 | 07194 | Filet steamer relay was bad was receiving voltage on input but output was not getting anything after replacing relay turned it on waited for it to heat up got to like 320 then went down and then started reading 60 degrees so definitely a bad temp probe since I stuck the pyrometer in and it was reading 250 so ordered that
-Fixed door hinge falling off fridge just retapped holes and put a bigger screw not sure how it’s gonna hold up should probably be welded but not gonna weld in the middle of lunch |
| 2355 | Waylon | 10/28/2024 | 18198 | -Diagnosed washer flooding the floor plastic broke on the agitator and causing it to leak through needs a new washer |
| 2354 | Brendan | 10/25/2024 | 04205 | -recrimped bump bar
-fixed hi c not working
-noticed they took strawberry shakes off the menu because it wasn’t working. The bag was unplugged…
-noticed they took mango pineapple off the menu because it wasn’t working. The bag was in the wrong spot… |
| 2353 | Brendan | 10/25/2024 | 00596 | -repaired bump bar cable
-troubleshooted ice cream machine. O ring broke in pump so it wasn’t pumping ice cream… |
| 2352 | Brendan | 10/25/2024 | 04956 | -replaced oven controller, all set |
| 2351 | Jim | 10/25/2024 | 07417 | - cut and installed new kitchen ceiling tile
- cut and installed two lite lenses
- cut and installed egg crate
- sprayed flex seal on prep sink drain |
| 2350 | Jim | 10/25/2024 | 04205 | - installed new baseboard tile in office and grouted
- replaced bottom bun toaster belt |
| 2349 | Waylon | 10/25/2024 | 04956 | Removed old power switch for cabinet and installed new now working still need to get a part from the office for the cabinet strip harness |
| 2335 | Jim | 10/21/2024 | 12272 | - replaced dish sink faucet and sprayer unit
- replaced the welcome sign panels , still need to do the thank you sign at route 102 and the one at the bottom of the long ramp to the side street entrance |
| 2310 | Jim | 10/17/2024 | 00596 | - got to store and ladies room toilets had no issues. Men’s room toilet was closed so I plunged and snaked, found two will sock’s flushed and they had two needles in them.
|
| 2308 | Jim | 10/17/2024 | 21582 | - replaced two baseboard tiles one outside and one inside walk-in and grouted
- grouted baseboard tile by kitchen hand sink
-adjusted. Trash door closer and latch
- sourced and installed chain to secure CO2 tanks in corral |
| 2273 | Jim | 10/09/2024 | 21582 | - loosened center screw on egg cooker to hold cover
- repaired siding on drive thru side and sanded
- purchased pac of kitchen ceiling tiles and installed missing one |
| 2348 | Jim | 10/25/2024 | 10622 | - replaced solenoid and piston on small toilet in ladies room, still not evacuating the bowl completely with the water flow wide open |
| 2347 | Waylon | 10/25/2024 | 18198 | Fixed 10:1 cabinet buttons |
| 2346 | Waylon | 10/24/2024 | 18198 | -Ran electrical was broken in part of the line so blew up when the breaker was turned on had to find the break and fix
-Electrical was for new oven which is now up and running all set no problems
-Installed new oep block that the electrical was ran into |
| 2345 | Brendan | 10/24/2024 | 17371 | -breakfast cabinet install. Had to run electrical and install new box. And then the hot was shorted to ground due to chafing so had to fix that, what a day… |
| 2344 | Jim | 10/24/2024 | 04205 | - filled large void in wall in office (need to return to install baseboard tile after it foam hardens up |
| 2343 | Jim | 10/24/2024 | 07194 | - painted stain in ladies room ceiling
- adjusted latch on toy display door lock |
| 2342 | Jim | 10/24/2024 | 25383 | - replaced three ceiling tiles above simplified breakfast unit
- replaced three floor tiles at drive thru one
- sourced and replaced corner guard at crew room entrance |
| 2341 | Brendan | 10/23/2024 | 12272 | -replaced kiosk 7 controller |
| 2340 | Brendan | 10/23/2024 | 02830 | -breakfast cabinet install. For once Ken’s didn’t leave me with a leak! But I did have to raise side 1 initiator monitor to be able to fit the bun rack which was obnoxious |
| 2339 | Waylon | 10/23/2024 | 10544 | -Welded fry station door hinge on which went on fine no problems at all threw door on then ran into the problem the door wouldn’t stay close which there was a old broken latching mechanism installed before so went and bought a magnet closing system then had to weld the magnet to the door then found out when magnets get heated up over 177 degrees they basically break and lose magnetism so that was a whole situation took forever ended up using one of the brackets I bought and two of Jim’s strong earth magnets and welded metal plates on to the door and now it stays closed
-installed new water regulator for filet steamer and water solenoid in filet steamer took a little bit first time doing a water solenoid but wasn’t too bad used the old wires to trace the new ones in and then it was just couple connections and screws and tested it |
| 2338 | Jim | 10/23/2024 | 10544 | - removed old exit sign , prepped mounting plate. Welded new studs on plate to accommodate new bolt pattern for new sign, wired new sign.
|
| 2337 | Jim | 10/23/2024 | 12272 | -replaced thank you signs at rout 102 exit
Replaced four baseboard tiles in office and grouted |
| 2336 | Jim | 10/23/2024 | 02038 | - replaced welcome sign panels |
| 2331 | Jim | 10/21/2024 | 00596 | -Worked in hand sink by office, tried liquid to help soften clog.
Then opened drain and ran snake about five feet and pulled clog out. Then ran five gallons of very hot water down with no issues
|
| 2334 | Waylon | 10/22/2024 | 07194 | Grill 3 call for top not staying down was a bad inline flow restrictor in the pneumatic system |
| 2333 | Waylon | 10/22/2024 | 18198 | -Needed a female OEP swapped from 30-20 amp installed that and tested |
| 2332 | Brendan | 10/21/2024 | 21582 | -breakfast cabinet install
-installed new pos15 and cable managed the cart |
| 2330 | Waylon | 10/21/2024 | 07194 | Side 2 landing zone replaced cord and fuses would’ve put a new plug on it but it’s like a specialty plug that I don’t carry reused old and waiting for it to heat up to temp |
| 2329 | Waylon | 10/21/2024 | 18198 | -Fixed hole in the wall behind pos 14/15 and behind the coffee brewers was a very interesting morning the coffee brewers quick connects broke leading to water being sent everywhere so that was amazing Brendan came and replumbed those and helped me move the table out had to disconnect everything in that area move it out to spray foam 3 conduits and the hole in wall then tiled over it and regrouted a 8x5 area |
| 2328 | Brendan | 10/21/2024 | 18198 | -cable managed and helped move back all the equipment |
| 2327 | Jim | 10/21/2024 | 04205 | - removed hand sink by prep station, all drain pipe and sink strainer were replaced with proper parts, also the new faucet was damaged upon opening, so I replaced with a hands free unit I had in the truck.
All connected, temps and works fine now. |
| 2326 | Brendan | 10/21/2024 | 10622 | -replaced leaky check valve in multiplex causing co2 leak
-replaced booster motor and replaced burnt wire
-troubleshooted ABS but found nothing conclusive. Such an intermittent problem that I can’t come to a diagnosis and I’m not going to go replacing 1k worth of parts for something that’s intermittent |
| 2325 | Brendan | 10/21/2024 | 18198 | -helped Waylon move up front equipment to access big mouse hole in wall
-replaced two coffee maker water lines and QDC |
| 2324 | Brendan | 10/18/2024 | 00596 | -replaced office printer |
| 2323 | Brendan | 10/18/2024 | 04205 | -card reader NTF, looks like stuff was spilled on the plug which was probably the issue
-fryer not filtering, cleaned the filter strainer but the pump has no suction, probably needs new motor, store will need to call in warranty service |
| 2322 | Brendan | 10/18/2024 | 07194 | -replaced cord and mounting bracket ped15 |
| 2321 | Brendan | 10/18/2024 | 10622 | -replaced filet water tube that was calcified, had to drill out the hole that’s how bad it was lol. Also had to tighten clamp on inside since it was leaking |
| 2320 | Brendan | 10/18/2024 | 17371 | -unclogged frappe drain
-replaced front handwash faucet
-replaced left coke tank figal connector |
| 2319 | Waylon | 10/18/2024 | 07417 | -Welded fry station door hinges on to the door took forever kept having gapping problems finally got it might need to go back to weld the part on the fry station but it was closing properly and looks good
-Welded new covers onto the trays in the veveeage fridge that had holes in it |
| 2318 | Jim | 10/18/2024 | 10622 | - adjusted water flow no change, looks like it needs a new flush diaphragm as it does not allow the water to flow with force even though the water shut off is fully open
I sent a text to Brendan with a picture of the unit |
| 2317 | Brendan | 10/17/2024 | 07417 | -replaced vizion permeate tank
-replaced all Dr Pepper bib compenents-new pump, changeover valve, lines, nozzles, and o rings. It is now maintaining suction and not foaming from air ingression 🎉 |
| 2316 | Jim | 10/18/2024 | 18198 | - completed all floor and wall tiles on list and grouted |
| 2315 | Waylon | 10/17/2024 | 18198 | This was so so so stupid, went to replace the FCB power cord first off this machine has two powers cords who would’ve known a cord on the inside that goes from the main computer to underneath machine back up into into an auto transformer female end then from the auto transformer to the wall fantastic and all first off took like 35 feet of cord to replace all of it took 2 new plugs like around 100$ in total all because the reason it needs to replace is we believe it was Glen the maintence guy decided to but a 6x4 awg cord on to a 10/3 cord which is insanely wrong and extremely unsafe first off the cord he replaced it with literally had an extra wire which he electrical taped over and secondly he wire nutted two cords together to make an extension cord then put tape all over it like if you don’t know what you are doing just don’t do it or Atleast ask us how to properly do it and wiring inside the auto transformer was just a nightmare first off it’s 35 pounds that you have to lift off and move with one hand then you can fit like 3 fingers inside it to wire it was just a mess anyways all fixed and 100% safe now |
| 2314 | Brendan | 10/17/2024 | 04205 | -troubleshooted moffat really loud, motor bearings completely detached. replaced motor, all set
-troubleshooting missing rootbeer, found a fitting to be leaking inside of the multiplex causing the multiplex to be FILLED with rootbeer syrup. CRAZY! So I repaired the leak, drained the multiplex, washed it out, and refilled it. Had to go to the store to buy a hose because the store didn't have one |
| 2313 | Jim | 10/17/2024 | 18198 | - removed and replaced three wall tiles in men’s room
- installed wall door stop in men’s room |
| 2312 | Waylon | 10/17/2024 | 10544 | -Leak coming from ABS ended up being a clogged drain behind the ice bin moved a couple things wet vac a lot of the water up two times to see the drain then snaked it at a very awkward angle could barely reach down there went 25 feet down the pipe cleared a little bit up since it started draining normally it’s like an inch and a half pipe and my snake is like 1/4 inch so I advised Annabelle to put draino or some type of drain cleaner down it to make sure it stays clear test ran a gallon bucket and ice machine clean mode that dumps water down the pipe
-Went to weld dry station doors first played a fun game of search through the whole store for them then found them only did the right side cause that was a part that was a weld on the door I refuse to do the left door in the middle of lunch with Lobby open so that’s gonna wait till a early morning day since god forbid someone gets blinded by the welding arc you know |
| 2311 | Brendan | 10/17/2024 | 04956 | -present screen no power, was just a tripped breaker but to be fair the breaker didn’t look tripped so can’t fault them for that
-breaker in hole tripped from plugging space heaters in and they couldn’t find the tripped breaker. Yet again just a breaker that doesn’t show when it’s tripped. Like we told Michael before their remodel their panels should have gotten replaced, this is what happens.. |
| 2309 | Waylon | 10/17/2024 | 21582 | -Had to steal a hood clip from south willow for Hanover RGR so uninstalled and then reinstalled hood clip have to pull out the grills to get to and typically get covered in yuckies but it’s done |
| 2307 | Waylon | 10/16/2024 | 18198 | -Installed new Coke Zero pump due to leaking co2 out of fitting
-Inspected hole in the wall to create some type of game plan |
| 2306 | Brendan | 10/16/2024 | 04956 | -ABS NTF
-looked at the shake machine failing heat cycle, was wayyyy over filled and failed to get down to temp so I put it at the right level and see if it goes through, if not they can call Taylor in the morning. I heard they need a new machine so it could've lost refrigerant |
| 2305 | Brendan | 10/16/2024 | 21582 | -replaced 2 ceiling tiles
-searched for condenser cover butttt was taken to office lol |
| 2304 | Brendan | 10/16/2024 | 00596 | -need new office printer
-fixed shake machine, mix draw tube fell out of pump |
| 2303 | Waylon | 10/16/2024 | 10622 | -Fixed men’s bathroom stall door not being able to lock
-fixed health department complaining about the filter not having an air gap so now there’s a 2.5 inch and 3 inch air gap on both lines |
| 2302 | Brendan | 10/16/2024 | 02038 | -replaced ped8
-replaced defective surge tank |
| 2301 | Jim | 10/16/2024 | 21582 | - installed soap dispenser in men’s room
- picked up gallon of grey exterior paint
- replaced weatherstripping on trash door
- mounted w/ screws PVC baseboard pieces at frappe machine
|
| 2300 | Jim | 10/16/2024 | 04205 | - cleared drain clog behind frappe machine , fed all lines into drain and lined up ice bin drain
- cleared slop sink drain clog
- replaced four 4 lobby ceiling tiles
- installed two pieces of weatherstripping on trash door |
| 2299 | Waylon | 10/15/2024 | 18198 | -Dr pepper pump replaced |
| 2298 | Waylon | 10/15/2024 | 00596 | -Diagnosed and fixed HLZ
-gave Laurel an update on Taylor coming out for that left grill which is what I assumed the problem to be a warped cook surface in the back but would prefer to have them tell Michael the grill is dying then me in hopes it actually does something |
| 2297 | Brendan | 10/15/2024 | 04956 | -replaced present monitor, poor thing got put out of its misery at almost 20 years old |
| 2296 | Brendan | 10/15/2024 | 10544 | -moffat cabinet install, had to fix yet another one of Ken’s mistakes |
| 2295 | Jim | 10/15/2024 | 21582 | - grouted baseboard tiles in crew room
- grouted floor at ice maker all the way past the nugget fryer
- grouted along grills up to fry hopper
- grouted in front of ice bin and cc frappe machine
-fastened wall paper at seam and in corner by lobby trash bin
-replaced two lobby ceiling tiles
-fixed rear delivery door and also the trash door,
Both needed latch to be shimmed so latch will engage correctly |
| 2294 | Brendan | 10/15/2024 | 07194 | -finally got melitta part in, replaced CBO and cleaned a few times
-replaced dt window electric eye |
| 2293 | Waylon | 10/15/2024 | 21582 | -Installed new yellow oep plug
-installed co2 sign
-fixed grill button |
| 2291 | Jim | 10/14/2024 | 21582 | - replaced rear hand sink drain pipes due to someone putting butter and clogged the pipes
- grouted back floor by stock shelves
- replaced 5 baseboard tiles in crew room
- grouted floor in front of ice bin |
| 2292 | Brendan | 10/14/2024 | 04205 | -attempted to clear mop sink drain, pulled out one linen with a snake, still slow so had to call east coast
-installed missing fc printer
-installed new fc picklist printer
-troubleshooted hand sink water, definitely needs a new faucet, can’t replace cartridges since the handle is seized. Need to see if we have one on one of our trucks |
| 2290 | Brendan | 10/14/2024 | 02830 | -replaced IBC probe
-repaired leaky backflush line in ceiling
-replaced broken dish sink hot water handle |
| 2289 | Brendan | 10/12/2024 | 17371 | -repaired numb bar wire
-repaired sanitizer bay stop valve
-troubleshooted handwash sink, new faucet on order |
| 2288 | Brendan | 10/12/2024 | 10622 | -searched for co2 leak, found in multiplex fitting between carb b tank and check valve. Will have to return on a morning to repair
-troubleshooted filet steamer, water tube clogged up solid with calcium, will need to order replacement and drill the old out |
| 2287 | Brendan | 10/12/2024 | 04956 | -power outage cause monitor to turn off, all I had to do was reboot which I asked them and they said they did🤥😑 |
| 2286 | Brendan | 10/11/2024 | 00596 | -ran wire and set up new cameras with danger zone monitors
-troubleshooted coffee brewer unplugged and plugged back in and brewed 6 pots with no issues🤷🏻♂️ |
| 2285 | Waylon | 10/11/2024 | 25383 | -well ran electrical new line from panel to the new oep bracket which was also installed but fun part was after all that install we found out the fucking panel only had one phase going to it means everything could only be 120V when all oeps are basically 208 SO LIKE GREAT FANTASTIC what electrician runs a sub panel with only one phase like what’s the flipping point for sweet potato’s so basically a waste of time need to run it to a new panel to get 208 😭😑 |
| 2284 | Brendan | 10/11/2024 | 25383 | -replaced camera monitor
-installed mirrored bake monitor and bump bar above grill
-installed ped standoff bracket ped1
-ran new circuit and installed new OEP box - BUT it ended up being a total waste of time because the panel we ran it to only had one phase… who runs a one phase panel in a McDonald’s?!?!?!?! Extremely irritating, will have to come back a different day to rerun the circuit to the center island panel which has more than one phase. What a total waste of a day🤬😭 |
| 2283 | Jim | 10/11/2024 | 21582 | - cut out 4 cracked floor tiles by CO2 tank, took exceptionally long time due to limited access and tiles did not want to cooperate, kept breaking into small pieces.
- installed three base tiles by frappe machine |
| 2282 | Waylon | 10/10/2024 | 25383 | -Fixed HLZ needed a new air heater so my diagnosis was correct last time I replaced the temp probe while I had it opened up because those like to go bad and it will just give a small prob error the air heater was probably the worst thing in the landing zone to replace its at the bottom of it so gotta remove couple parts just to get to it
-installed new exit sign drive thru vestibule |
| 2281 | Jim | 10/10/2024 | 07417 | - assorted floor and wall tiles replaced and grouted
- took down wall paper entering crew room and painted wall,also added corner guard. used some wall paper to cover crew room window.
- remounted bug lite in crew room |
| 2280 | Brendan | 10/10/2024 | 21582 | -replaced rollers for dt window, adjusted, cleaned track, replaced nylon guide, adjusted pitch, replaced broken handle. Now closes by itself
-installed printer pos2
-replaced membrane and pump on RO, should be all fixed now
-repaired trash door not unlatching |
| 2279 | Brendan | 10/10/2024 | 07194 | -troubleshooted leak under ABS. Cleared drain pan just in case but it’s an ice machine issue
-troubleshooted dt window, beam box on order |
| 2278 | Jim | 10/10/2024 | 02038 | - grouted in front of and under ice bin and coffee brewer
- today’s morning in store maintenance man found hose behind hot water tank area that was dripping, I installed two hose clamps and looks like it worked |
| 2277 | Waylon | 10/09/2024 | 10544 | -Installed new water line for filet steamer was leaking out of the line coming right after the ceiling tile so replaced the whole line
-Went to go run filet steamer found out the regulator is bad reading 80 psi when it’s turned off and water solenoid isn’t clicking at all not letting any water through need to order both the amount of money put into this steamer is insane we should’ve just bought a new one
-Looked at fry hopper compressor not running so wasn’t keeping temp just moved the compressor plug and it clicked rigjt on hoping that was the only problem it just needed a little jump start since it instantly started cooling down |
| 2276 | Brendan | 10/09/2024 | 04205 | -fixed French fry vat error, needed to press reset button on motor
-new breakfast cabinet installed
-coffee brewer now working
-both hand wash faucets are working fine NTF
-all shakes and ice cream working fine NTF
-we went over this leak before the RGR, the leak under lobby sodas is because someone turned the snail fan off, I turned it back on
-the leak by the ice machine we aren’t doing anything about because it’s a small leak and an expensive fix, we had a snail fan back there too before the RGR but idk where it went
-noticed a printer on front counter completely missing, no idea why or where so if you could find it and put it back please
-I couldn’t fix the root beer because store is all out of root beer |
| 2275 | Jim | 10/09/2024 | 02038 | - welded oil pan wheels bracket back on and also welded multiple areas to prevent leaks. Welded drain pipe back on oil pan.
- ladies room toilet removed, old bolts replaced, new wax seal installed. Put it back together and it leaked when flushed, so removed toilet again and added extra wax seal. That fixed the problem and I re caulked the toilet to the floor |
| 2274 | Waylon | 10/09/2024 | 02830 | -Went to look at grill originally thought bad motor based of photos but got here and it was working and in use so took off cover watched it auto level 2 times the left motor was in question right motor was making some not so promising sounds but it auto leveled 2 times leaving it alone since if we can get some more life out of those motors mine as well recommending that both get replaced when one dies since it’s a pain in the butt to get to the back ones anyways
-Installed new 10:1 freezer cord gave a extra couple feet of slack so it can be pulled out
-Installed new parts for roof hatch new springs and handle bar
|
| 2272 | Brendan | 10/08/2024 | 07417 | -repaired dt lane 1 speaker not producing sound |
| 2271 | Brendan | 10/08/2024 | 17371 | -replaced front door handle
-troubleshooted muffin toaster. Broken wire again… I checked amp drawer and temp probes and they are all okay so can’t find any reason why it burnt off |
| 2270 | Jim | 10/08/2024 | 10544 | - removed one each old enter / exit signs on east hollis entrance and welded new bolts and completed install . Also removed enter sign and replaced with new enter sign , was able t to use existing bolts
Need to get another extension cord and roll of welding wire to complete last exit sign |
| 2269 | Brendan | 10/07/2024 | 04956 | -replaced cash drawer 15 and repaired cash drawer 1
-installed new gasket on fc bottle fridge
-vga cord loose side 2 lunch |
| 2268 | Brendan | 10/07/2024 | 12272 | -called for dead monitor and printers. All they had to do was press the power button… and the printers weren’t working because they were deliberately unplugged… |
| 2267 | Jim | 10/07/2024 | 10544 | - sourced and installed piece of drywall in lobby closet and applied coat of mud |
| 2266 | Brendan | 10/07/2024 | 21582 | -troubleshooted Hanover espresso, bad milk pump replaced, caused by leak on a fitting, on order
-replaced McFlurry spinner motor |
| 2265 | Jim | 10/07/2024 | 25383 | - cut and installed 13 floor tiles by delivery door and grouted
-cut and replaced 3 vestibule ceiling tiles |
| 2264 | Waylon | 10/07/2024 | 00596 | Went for a grill call on an infinite gap (regret staying home since I’m sick) so absolutely lost with what to do on this grill so the grill works perfectly fine on everything except folded egg on folded egg with the black bracket down it hits the bracket and gets stuck up which I was like okay probably the gap adjustment for just folded egg I adjusted it to the exact same as the platen next to which was running perfectly and still same issue alright then was thinking maybe the belts checked the belts nope all perfectly fine one looks basically brand new went through all the settings made sure everything lined up perfectly as it should then scrapped the back grease plates cause maybe it was getting caught up on grease but nothing adds up since it works great on everything else so gonna give dug a call tmrw regarding it since I can’t talk at the moment and see if he has ever had this problem before I’m weighing it down to I think it’s either motor going bad slowly, warped back platen or I had a 3rd idea and forgot either way I feel useless right now P.S these grills suck are the oldest and should’ve been replaced like 10 years ago 😭 I’ve barely spent much time on the infinite gaps
-Picked up cash drawers for Raymond |
| 2263 | Brendan | 10/07/2024 | 02830 | -soda not working. Multiplex had multiple issues. Recirc B line had a hole in it, recirc B motor was dead and overheating causing the carb B motor to thermal cutout, and IBC probe needs replacement. I replaced the broken line, recirc motor, and recirc B temp probe. All soda is up now, will need to return to replace IBC probe once ice bath has thawed |
| 2262 | Brendan | 10/04/2024 | 17371 | Replaced Big Mac wallpaper, what a project. Never again, never again… |
| 2261 | Waylon | 10/04/2024 | 17371 | -Installed Big Mac wallpaper had to sand wall down prime then install wallpaper took a while
|
| 2260 | Jim | 10/04/2024 | 21582 | - installed new flush control solenoid on ladies handicap toilet
- painted and installed corner guard by drive thru one
- replaced FRP trim piece by kitchen sink and filled holes
- drive thru safety rail tightened
- re fastened wall paper in crew room
- cut and installed base tile and grouted by hand sink in kitchen by fry hopper |
| 2259 | Brendan | 10/03/2024 | 21582 | -repaired coffee brewer, replaced lots of parts, temp probe, level probe with their associated harness, board, and fill valve
-disabled all coffee pot warmers |
| 2258 | Waylon | 10/03/2024 | 17371 | -Screw contactors had to replace the heat contactor in vat 1 that was miserable like always is but it’s just a remind how much it sucks since everything is crammed in a little box and you have to crawl under the fryer and get grease all over you
-Took out ketchup in lobbby with Jim’s help
-replaced water fill solenoid in coffee brewer and leak tested rwice |
| 2257 | Brendan | 10/03/2024 | 02038 | -replaced dispense head thermistor, all working |
| 2256 | Jim | 10/03/2024 | 17371 | -helped Waylon remove two ketchup dispensers in lobby drink station
- removed old wallpaper and prepped wall as directed in instructions
While applying primer for new wallpaper the primer cracked and peeled in many places. I removed lifted primer and redid the prep steps again , it happened again. Looks like a professional paper hanger will be need to complete.
- filled and color matched holes in lobby where TV was. |
| 2255 | Jim | 10/02/2024 | 17371 | - snaked 15 ‘ and plunged, finally got the toilet to fully flush
- got info on needed items for wallpaper replacement |
| 2253 | Waylon | 10/02/2024 | 18198 | -removed old office monitor and installed new monitor and mounted to wall
-had to pull more of the vga cable from ceiling for office computer
-Installed a new cord on 2 drawer fridge upfront 20 foot power cord so it can run behind all the equipment with their setup
-Picked up supplies to do the frozen beverage machine but didn’t get to it
-Installed mount for monitor upfront waiting for the monitor to come in mail specialty monitor for the old camera system cables |
| 2254 | Waylon | 10/03/2024 | 18198 | Installed monitor for cameras upfront |
| 2252 | Brendan | 10/02/2024 | 02038 | -replaced tea brewer board and track, working good now
-tried to recrimp bump bar side 2 breakfast but wire was crumbling apart, had to replace whole wire |
| 2251 | Brendan | 10/02/2024 | 07417 | -installed breakfast cabinet, but oep went missing so will need to do that when I get one in. Had to fix Ken’s mess because they left the new filters leaking🤦♂️ |
| 2250 | Jim | 10/02/2024 | 10622 | - Installed screws in all crew room seats. Apparently someone has been unscrewing the screws during a shift, no camera in crew room, so I installed screws and ground the Phillips heads so they can’t be unscrewed.
- removed and installed new enter and exit signs. Had to weld all new studs due to sever corrosion. |
| 2249 | Waylon | 10/01/2024 | 02830 | -Replaced front motor in grill 4 was automatically dropping the platen lower then gap and turned wayyyy to easily like something snapped in it for a motor which normally takes a good amount of strength to turn
-Back right of platen was getting stuck up then dropping when weight was put on was just grease build up on the shields |
| 2248 | Jim | 10/01/2024 | 18198 | - re fastened threshold on drive thru vestibule
- cut and installed baseboard tile by slop sink
- took pictures of all damaged tile on list to take and match |
| 2247 | Jim | 10/01/2024 | 10622 | - plunged ladies room toilet and adjusted water to highest level, also changed batteries, still flushing weak.
May need solenoid or diaphragm.
I left it on the list as Venus stated it clogs very easily under this condition.
|
| 2246 | Waylon | 10/01/2024 | 21582 | -grill PM with Brendan
-Installed co2 sign |
| 2245 | Brendan | 10/01/2024 | 21582 | -right grill cert |
| 2244 | Jim | 10/01/2024 | 04205 | - checked men’s room toilet for clog, found no issues. Flushed multiple times to try and replicate stated issue and checked all connections, |
| 2243 | Jim | 10/01/2024 | 21582 | - replaced six floor tiles by sink and slop sink area and grouted |
| 2242 | Brendan | 09/30/2024 | 04956 | -fryer filter speed NTF
-repaired beef drawer not closing properly
-measured return duct size because the remodelers didn’t bother butting a return pan and just left hanging in the ceiling…. |
| 2241 | Brendan | 09/30/2024 | 02038 | -troubleshooted tea brewer. Bad triac and board, board is only outputting 60v to the triac, which must’ve killed it because it won’t switch on. On order
-troubleshooted frappe machine refrigeration, dispense head shorted probe. On order |
| 2240 | Brendan | 09/30/2024 | 12272 | -fixed kiosk 6 not turning on
-fixed ped7 not turning on
-troubleshooted coffee brewer. Part on order |
| 2239 | Brendan | 09/30/2024 | 21582 | -grill cert
-major RO work, looks like it needs a new pump since it’s bypassed |
| 2238 | Waylon | 09/30/2024 | 21582 | -Grill PM with Brendan
-Welded one bolt that snapped as Jim was installing the new sign
-Cut hole in old RO tank to drain out store said they have a scrap person for it so it’s in the corral |
| 2237 | Jim | 09/30/2024 | 04956 | - adjusted mix of hot and cold water on both hand sinks, now temping at 104 degrees
- fastened seat cushion on lobby bench seat |
| 2236 | Jim | 09/30/2024 | 02830 | - sourced and replaced stock room ceiling light fixture with new led |
| 2235 | Brendan | 09/28/2024 | 10622 | -breakfast cabinet issue wasn’t really an issue, someone just dislodged the drip pan on the door; all set
-kiosk screens NTF |
| 2234 | Brendan | 09/28/2024 | 21582 | -repaired back door that wouldn’t unlock
-troubleshooted coffee brewer. Parts on order |
| 2233 | Brendan | 09/28/2024 | 04205 | -troubleshooted soda issues. Had to dial up the coke calibration a little. Other water issues caused by bad booster pump that keeps clogging the filters. Bypassed filter for now to get all equipment running so should be okay until I receive the new filters and pump. Only downside the clear drinks may be slightly discolored.
-office door not latching closed; ground out strike plate latching now |
| 2232 | Waylon | 09/27/2024 | 04956 | Programmed fryers
Had to replacee one cabinet strip and swap the sides since last time I went here I swapped them so their side 1 could work all set now might need a cowl assembly which I would have to get at the office cabinet which office is closed by now |
| 2231 | Waylon | 09/27/2024 | 00596 | -Installed new rocker switch for cheese fridge
-Installed 2 new cabinet strips and had to diagnose further found the display board on the strip to be broken had 3 small burn marks where the cabinet strip plugs into took so hopefully Brendan can sauder it replaced with one from my van last one I had
-Replaced filet steamer regulator and recipes waterlines inside ran 3 times to leak test all set |
| 2230 | Jim | 09/27/2024 | 10622 |
- made Swahili for water by drive thru number one parking spot, so water runs off parking lot
- replaced light in stockroom with new led, old cover was broken
- cleared clog in ladies room toilet
-cleared gutter above walkin &swept standing water off roof
- checked soffit lights could not find issue |
| 2229 | Waylon | 09/26/2024 | 17371 | -Fixed muffin toaster originally thought it was a bad element a couple days ago went to install a new element found a frayed wire deep inside it that you could only find when taking apart the whole top of it so repaired that with a new terminal and tested so we now have a spare element which is fine one will go bad in one of the stores so save it for that
-was told the fryer kept low temping time after time so dived into that got grease in my hair 😡😡😡 but found a bad contactor only one leg was pulling to heat gonna order both contractors since im already doing one down there
-Installed a new printer and picked up old one to give to Brendan for repair |
| 2228 | Jim | 09/26/2024 | 02038 | - grouted under fry hopper and double fridge
- grouted from in front of walk in to dishwasher
- check hand sink found no leaks
- tree room window sill,
Left side was dug out so I cleaned and filled with drywall compound.
Sanded and found no mold or active fruit flies |
| 2227 | Jim | 09/26/2024 | 10544 | - replaced six tiles by trash door and grouted
- installed cement board in maintenance closet by sink
- grouted multiple areas of store |
| 2226 | Waylon | 09/25/2024 | 10544 | -Installed exit sign had to weld and run electrical for
-Swapped a vent hood bracket from an old one to one above grill took a while cause those aren’t supposed to be removed and reused more so replaced when gone
Had to cut metal and weld a tiny cover piece in oven
-filled crack in picnic table which should be replaced cause concrete caulk to any gonna fix that but hey 🤷🏼♂️ |
| 2225 | Jim | 09/25/2024 | 10544 | - repaired rot on delivery door frame
- replaced latch side weatherstripping on delivery door
- replaced 5 floor tiles and grouted by walk in
- prepped exit sign plate for install
- installed two covers on light poles
- cut and installed six ceiling tiles
|
| 2224 | Brendan | 09/24/2024 | 02038 | -replaced water temp probe breakfast cabinet |
| 2222 | Waylon | 09/24/2024 | 10544 | -Installed new enter sign sawed off all the bolts on the exit sign to just need to replace had to rerun electrical through it and weld the putter plate down
-Grouted floor by washing machine still needs more ran out
|
| 2223 | Waylon | 09/24/2024 | 10544 | -Installed new enter sign sawed off all the bolts on the exit sign to just need to replace had to rerun electrical through it and weld the putter plate down
-Grouted floor by washing machine still needs more ran out
|
| 2221 | Jim | 09/24/2024 | 10544 | - worked with Waylon on replacing the enter and exit signs
- replaced six floor tiles ( four in front of walk in and two by the grill
And grouted)
- grouted by ice bin up front and in front of nugget fryer |
| 2220 | Brendan | 09/24/2024 | 10544 | -tried to find leak under SSBS very small leak but i think it’s coming from two of the valve fittings, on order |
| 2219 | Brendan | 09/24/2024 | 25383 | -no soda in store, multiplex breaker kept tripping due to a faulty recirc pump. Replaced the pump and had to dry out all the electrics really thoroughly |
| 2218 | Jim | 09/24/2024 | 04956 | - sourced parts and repaired leak under sink , also installed isolation valves for future repairs |
| 2217 | Brendan | 09/23/2024 | 07417 | -troubleshooted shake machine beater overload. Looks like bad gear box, motor intermittently pulling too much current, but it also looks brand new, so will ask Doug in the morning because one of them worked on it last I believe. |
| 2216 | Brendan | 09/23/2024 | 21582 | -troubleshooted ABS. lift sensor had syrup shorting it out, cleaned up with a generous dose of contact cleaner all set
-installed quick connect fitting on new fryer
-troubleshooted McFlurry spinner, bad motor assy again. On order
-ordering side panel for prep fridge |
| 2215 | Waylon | 09/23/2024 | 10544 | Filet steamer relay
3 cabinet strips
Mounted hand sanitizer dispensers
Fixed water leak back sink just tightened fittings
Screws for coffee brewer
Mounted fry station salt shaker holder
Gapped grill #2 and food safety tested by Annabelle
Took picture of curbside sign need to be pickup at office
Fry station doors test fit found like 1 inch 7/8 gap between doors looks pretty ghetto waiting on Brendan to get back to me regarding if Drew still wants them installed
Should be able to get a 4-5 inch clean out for woman’s room next time |
| 2214 | Brendan | 09/20/2024 | 10544 | -cherry FCB was working fine
-troubleshooted filet steamer. This thing is a money pit, relay bad keeps tripping high limit
-breakfast cabinet survey
-beef fridge handle on back order
-ordered UHC strips |
| 2213 | Brendan | 09/20/2024 | 02038 | -cleaned and calibrated FFLS screen
-troubleshooted moffat cabinet, bad computer. New one being sent under warranty |
| 2212 | Brendan | 09/20/2024 | 04205 | -replaced home switch platen 3 |
| 2211 | Brendan | 09/20/2024 | 02830 | -troubleshooted FFLS, sticker got stuck on paper sensor. Had to take apart to remove. All set |
| 2210 | Jim | 09/20/2024 | 10622 | - replaced light ballast in light above the slop sink |
| 2209 | Brendan | 09/20/2024 | 18198 | -ABS working perfectly fine as soon as I put the conveyor on. NTF. Did replace grip pads though.
-ordered part for roof hatch leaking
-was told the fridge was freezing lettuce. They showed me lettuce the thought was “frozen” but looked like normal lettuce to me. Temped lettuce at 36° so I think they’re just crazy |
| 2208 | Jim | 09/20/2024 | 07417 | - checked all toilets found ladies handicap stall locked
Adjusted the flush control flow and works fine now |
| 2207 | Jim | 09/20/2024 | 04205 | - re set men’s room urinal flush control valve as someone seemed to have yanked it sideways and caused the water to leak |
| 2206 | Jim | 09/20/2024 | 00596 | - installed new clearance bar at Drive Thru
- repaired and remounted door guard on men’s room stall door
-remounted lobby McDonalds brothers plaque
- replaced top transition strip on left hand gate |
| 2205 | Waylon | 09/19/2024 | 17371 | -DT window bump bar
-muffin toaster diagnosis bad heating element need to order
-pulled old platen off installed new ran new wires had to undo electrical redo had to re hookup springs and reinstall all the stuff taken out the other night food safety tested and watched motors run all looks excellent
|
| 2204 | Brendan | 09/19/2024 | 00596 | -repaired ABS thru beam sensor
-simplified breakfast cabinet install
-repaired cbb printer
-ordering power switch for cheese fridge and filet steamer regulator |
| 2203 | Jim | 09/19/2024 | 00596 | - got text from Laurel asking if I could go help them turn the outside water on. Upon arrival I found the issue was they did not have a four way faucet wrench.
We looked in the office file cabinet and found what they needed.
All set |
| 2202 | Jim | 09/19/2024 | 21582 | - grouted in front of ice bin
- replaced three floor tiles and grouted by time clock
- grouted area by sink and area by syrup boxes
|
| 2201 | Waylon | 09/18/2024 | 07194 | -Ran diagnostics on frappe machine motor lock according to Linda and Kayla hasn’t happened once during their shifts only night side shifts but just to double check anyways probed shaver motor almost everything read as it should be questioned one thing a little bit but not enough since the problem was a 24/7 motor lock it coincidentally only happens at night all tested fine then stress tested it by shaving a whole bucket worth of ice
-Fixed plug for breakfast steamer the cord doesn’t have much slack so it seems they kept pushing it away and that slowly caused the wires to come undone from the plug I locked the wheels and told Linda if she sees it consistently be a problem of people pushing it back we will have to run a new cord for it with more slack
- abs was getting caught that there was a cup in front of the sensor it was just the clear plastic covers removed and worked fine told them they can wash them and try to reinstall them but if not just leave it out doesn’t make a difference |
| 2200 | Jim | 09/18/2024 | 21582 | - installed ceiling grid piece on side 2
- cut and filled 2 large cracks on corral apron
- repaired FRP trim on side 1
- foamed & cemented foundation under drive thru window 1
- screwed and filled cracked and uneven corner boards by emergency exit door and sanded |
| 2198 | Waylon | 09/18/2024 | 21582 | -went for a bun toaster call of sensor a failing got here it was running fine just to make sure it was fine ohmed the thermocouples all read about the same meaning they were all fine and one didn’t go bad none were stuck open so that’s good they told me that they hadn’t changed the tethlons in a long time and all the metal was fraying off so potentially could’ve caused the sensor to trip |
| 2197 | Waylon | 09/17/2024 | 10544 | -Filet steamer got the best of me and took forever had to dissemble the whole thing installed new
Main board
Computer
2x new switches
New power cord
Swapped oep from old to new power cord
Got stuck up for two hours because it kept tripping the breaker whenever power was added found out it was because the circuit board was touching metal causing it to trip and spark multiple times but I didn’t catch on to that for a while so i traced all my wires back to make sure none of the connecting were hitting bare metal just for it to be that….
Also the switch pops out a little cause it jeeew 90 degree terminals on it but that’s a fix at a later date it’s pretty secured just noticeable if you look into it
Installed new water line in steamer |
| 2196 | Waylon | 09/17/2024 | 00596 | -Diagnsoed abs bad sensor need to order - Brendan will install
-Filet steamer leaking the leak was the plastic cover for the filter washed and screwed back on tiny leak on the water hose having Laurel keep an eye on it for 1-2 days I think it’s a very very very baby leak it’s not worth buying a whole new hose for
-Caulked sink by the sticker printer cause water was dripping from the side used caulk that was left out by Debby so in question how good it is tbh but hopefully it’s fine |
| 2195 | Jim | 09/17/2024 | 10544 | - replaced 16 floor tiles in front of right hand grill and grouted
- replaced 16 floor tiles in front of left hand grill and grouted |
| 2194 | Waylon | 09/16/2024 | 17371 | Installed new right motor for platen two grill had to removed the whole entire harness disconnect all the wires and then put everything back together and gap when putting back together a small screw broke that keeps the belt in place made a makeshift piece of metal to fix it
-went to go install new platen found out it’s definitely not a one person job called Doug after I got halfway into the project he said I was on the right track recommended ordering new hall motor lines and the process of putting in a new platen is insane I removed belts and removed the whole harness for all the motors taped of all live wires took out handle still need to take of plates on platen then cut old harness out and then rerun all new wire to both legs of the grill so still a lot of work left have to call Taylor tomorrow to order those two new wires then when those come in will come back left them without that platen since the grill is taken apart but made sure it’s safe so no one can get hurt |
| 2193 | Jim | 09/16/2024 | 21582 | - replaced two messed up floor tiles by fry station and grouted
- re fastened wallpaper in lobby and vestibule
- installed new ceiling tiles in lobby and vestibule along with grid piece
- unboxed fryer and moved to crew room
- fiberglassed trash door holes
|
| 2192 | Waylon | 09/16/2024 | 10622 | -Grouted underneath abs hard to reach area got to the back wall and under soda lines not the prettiest job with how dirty it was but every tile is grouted left snail fan on it and told them to leave ice machine off for another 2 hours so the grout can set |
| 2191 | Jim | 09/16/2024 | 10544 | - cleared drain on men’s room urinal
- adjusted rear trash door to close on its own
- replaced three handicap sighs and new handicap stickers on doors |
| 2190 | Jim | 09/16/2024 | 12272 | - checked door latch, worked fine no issues
- replaced leaking sink spray nozzle and flex line, were leaking bad |
| 2189 | Brendan | 09/13/2024 | 02830 | -repaired melitta, my initial diagnosis of defective flow meter was correct. Replaced flow meter, covered with plastic so water won’t get in it anymore. made a few drinks working great
-installed speakers on KVS 1 and 2 |
| 2188 | Brendan | 09/13/2024 | 17371 | -fixed many issues with FCB, replaced cherry syrup valve, coke expansion tank, and coke draw valve rebuild kit
-replaced Dr Pepper nozzle |
| 2187 | Waylon | 09/13/2024 | 10622 | Set up snail fan under abs to dry it all out
Moved water line across store to the convo oven
Welded the fried product filter box corner was splitting off welded and grounded down outside and welded inside can’t grind down cause of area restrictions |
| 2186 | Brendan | 09/13/2024 | 10622 | -simplified breakfast cabinet install
-ABS no cracking in ice bin that’s good. Believe the issue was a wire in the way of the ice bin drain was causing the water to follow the wire down underneath. Moved the wire and leaking seems to have slowed. Put snail fan underneath to dry it out, instructed them to leave the ice bin empty until Monday when Waylon comes back to grout |
| 2185 | Jim | 09/13/2024 | 21582 | - replaced 4 floor tiles and grouted by fry station
- fixed delivery for latch and Detex works fine now
- installed chain around small CO2 tanks
- repaired ladies room ceiling vent |
| 2184 | Waylon | 09/12/2024 | 10544 | -Filet steamer needs 3 new parts wanna replace switch that is in bad need of repair needs a new power cord install all wires are fraying needs a new computer board that is fried and a main board should be order because it’s charred pretty bad
- grill was giving home switch not seen error the motor wasn’t turning back into the switch but upon removing the switch a screw was loose causing it to push away to much so it wouldn’t be seen originally looked like a bad motor cause when the switch is pressed or not pressed motor moves up or down was working fine randomly shut off when I was about to leave turned back on fine not sure if someone accidentally hit it but the computer is definitely in question of being bad working as of now though
-Friar fished metal out of the disposal drain causing it to not close at all then filled and made sure it came to temp |
| 2183 | Brendan | 09/12/2024 | 10622 | -investigated worm issue again, ABS leaking. Think it may be coming from cracked ice bin. Turned off ice maker and will return tmr to see.
-dt window working perfectly fine NTF
-shake machine leaking vanilla, o ring completely missing. All set now
-troubleshooted grill open probe. Connector was slightly disconnected from computer causing the issue |
| 2182 | Waylon | 09/12/2024 | 02038 | -looked at ice bin and sent video to Brendan I did not see any cracks or damage in the bin itself
-Looked at slow drain the drain is perfectly fine the problem is stuffing 3 drain lines into a small hole talked to Brendan about it I removed the funnel that was there cause it was causing water to splash out the sides drained fine for me without it rinsed ice machine 3-4 times to dispense a lot of water at one time looked good
-Small leak under abs drain pan drain needs to be adjusted probably but it’s a tiny leak and peak lunch is probably not the ideal time to disconnect drains
-Abs cups were getting stuck for small cups removed one of the turret sleeve and bent the prongs ran 5-8 test cups through and was good
-Installed co2 sniffer and tested all alarms since the last one got water into it I put a line of electrical tape over the new one and move it to a different spot
- replaced part of frappe machine water line that was spraying water everywhere up and running all set
-Added another co2 alarm sign above office door so there’s 2 now one old one new since I heard Shannon wants to see the new ones |
| 2181 | Jim | 09/12/2024 | 21582 | - found washing machine issue, drain under stock room rack was snaked and cleared clog
- painted and installed five corner protectors
- re installed top plate on kiosk
- replaced and grouted three floor tiles under sink
- helped clean what stain off exterior tiles in front of building
- filled hole in trash door |
| 2178 | Waylon | 09/11/2024 | 04205 | -Took apart grill because home switch not seen yesterday, measured VAC across terminal block checked out perfectly then watched the platen go up and down heard the switch click multiple times and you can see where the motor hits it so that’s all set they’ve been using it all morning the switch does look like it’s lived a solid life so I asked Brendan to order another but for now they’ve been using the grill fine |
| 2180 | Brendan | 09/11/2024 | 07194 | -fry hopper of confusion… definitely something on compressor side of things. Rick supposed to come out tmr |
| 2179 | Waylon | 09/11/2024 | 25383 | -Gave Jim some building supplies (Frp and plastic glass)
-Fixed qing oven needed a new door switch
-Pit a new OEP on the end of the qing oven that Brendan stole for the convection oven just needs electrical ran so it can be plugged in
-Diagnosed HLZ and fixed a part of it so HLZ was missing the wire grommet that holes the wires still so one of the female terminals popped off causing the spark so I drilled the hole bigger to fit a grommet since they don’t seek the ones for the landing zone anymore then added all new terminals to the power cord and waited for it to heat up the air heater temp was stuck at 170 should be 220 so started diagnosing air heater relay looked good so leaves us with the RTD probe and air heater itself went to measure resistance from the air heater should get 22-26 ohms got 68 ohms means it’s not doing it’s job so gonna order a new one |
| 2177 | Brendan | 09/11/2024 | 02830 | -ABS arm slow, had to replace lift cylinder and also umbilical as it was in really bad shape |
| 2176 | Jim | 09/11/2024 | 25383 | - caulked holes in lobby wall
- cut and installed new weather stripping on delivery door
- cut and installed outside light covers |
| 2175 | Jim | 09/11/2024 | 12272 | - men’s room toilet, had to R&R toilet as one of the closet bolts popped out so replaced closet bolts with larger ones and replaced seal.
|
| 2174 | Brendan | 09/11/2024 | 02038 | -replaced bump bar and recrimped cable
-unclogged frappe drain pan
-plug by trash can in play place is working, it is connected to a nighttime light breaker that’s why it was off |
| 2173 | Brendan | 09/11/2024 | 12272 | -multiplex leaking, replaced recirc line strainer bowl/gasket
-noticed IBC went bad last time, replaced today. Working properly and relocated probe to correct placement |
| 2172 | Jim | 09/11/2024 | 10622 | - installed new left soap dispenser
- tightened faucet spout
- re installed wall tile and grouted above front area
- unable to install new enter and exit signs: one has no studs or bolts to attach the new sign. The other has two studs that broke and the other two just spin.
Will need to get with Waylon so we can weld the studs we need to install |
| 2171 | Waylon | 09/10/2024 | 07194 | -Installed 2 new relays for platen 4 was only a pain cause the nuts holding the relays in no tool was skinny enough to grab ended up using an extension on my impact and a nut driver to get it off
-spent time on the fry hopper found it to not be the switch that’s the problem seems to be a bad compressor but Brendan’s gonna double check that tomorrow |
| 2170 | Brendan | 09/10/2024 | 04956 | -crimped milk bag connector back on melitta |
| 2169 | Brendan | 09/10/2024 | 02038 | -shake machine training (only charging half labor since it was shared with training 2nd st) |
| 2168 | Waylon | 09/10/2024 | 18198 | -Replaced springs in dt beverage fridge
-Abs arm stuck mid lunch got that
-Got 3 access panels for behind washing machine had to cut to fit all 3 and two had to cut the holes basically 2 times bigger since the access panels were all certain sizes |
| 2167 | Brendan | 09/10/2024 | 04205 | -shake machine training (only charging half labor since it was shared with training derry) |
| 2166 | Jim | 09/10/2024 | 17371 | - - mounted new #2 sign
-fixed perimeter fence
- fixed what plastic fence
-grouted tiles in men’s room
- adjusted freezer door so it will close by itself |
| 2165 | Brendan | 09/10/2024 | 12272 | -fixed ped2, bakery carts crushed one of the ports so using spare port
-fixed POS not sending orders to ABS
-repaired dt window 2 chain that fell off track, need to stop being so rough with the window please
-looked at meat freezer lid issue, new lid on order
-looked at multiplex leaking. Has two issues, leaking strainer bowl and bad IBC probe. Turned off refrigeration and will need to return on a morning so I can turn soda off
-repaired lobby door not opening, screw fell out. Replaced and also adjusted door closing so it would latch automatically
-fry hopper was fine just assembled incorrectly. Funnel not completely clicked into place |
| 2164 | Jim | 09/10/2024 | 07417 | - checked men’s room urinal and the drain cleaner I used yesterday seems to have done the job, drains fine now |
| 2163 | Jim | 09/10/2024 | 07417 | - picked up and installed new spud nut on left side men’s room urinal
- R&R men’s room toilet, was told it smelled after flushing. Upon removal I found the wax seal missing and the floor broken, so I cleaned the area out and added fast set concrete to facilitate the new toilet ring and seal.
|
| 2162 | Waylon | 09/09/2024 | 17371 | -Fixed hot water mop sink
-Replaced GFCI outlet behind 10:1 freezer and taped off inside electrical box
-Diagnosed platen 2 looks to be another bad motor where the wires go into the motor wires are becoming frayed when tugged on causes motor halt
-Replaced motor in platen 4 because of the same issue with platen 2 I just don’t have another motor so ordered that |
| 2161 | Brendan | 09/09/2024 | 18198 | -replaced ped13
-found no mold on FCB
-coke tank needs new connector, store needs to let me know when that tank is empty so I can replace it
-tablet won’t charge because they are using the wrong cord/brick. I just bought the store a new cord and brick last month so they need to only use that one |
| 2160 | Brendan | 09/09/2024 | 17371 | -ABS not dispensing soda water, bad armature. Replaced all set
-troubleshooted FCB leaking. Found 3 problems. Cherry syrup valve broken and leaking. Coke expansion tank ruptured and leaking. Coke draw valve also only intermittently dispenses. Parts on order
-ordered 5 drawer inserts
-measured BIG MAC wallpaper for replacement |
| 2159 | Jim | 09/09/2024 | 07417 | -replaced sink gasket on right hand sink
- made and installed cover over clean out in lobby |
| 2158 | Waylon | 09/09/2024 | 18198 | -Was told iPad wasn’t working at all tooo a charger from my car plugged it in said it was charging sat with it for a while it turned on they just weren’t being patient with it and I assume they thought when a tablet is dead it magically turns on instantly
-Lonby root beer wasn’t working cleaned armature arms off was only dispensing syrup now working fine takes a second for the solenoid to clock on most likely needs a new armature tip but I don’t have one in my van so will have to wait but is working now after cleaning it |
| 2157 | Jim | 09/09/2024 | 21582 | - replaced washing machine
- shined railing by drive thru
- re attached wallpaper on drive thru side vestibule |
| 2156 | Jim | 09/09/2024 | 00596 | - cut and installed light lens by sink
-re installed light lens in stock room above CO2 tank
- cleaned and installed egg crate vent cover |
| 2155 | Brendan | 09/06/2024 | 04205 | -added air gap for ice machine per health dept |
| 2154 | Brendan | 09/06/2024 | 02830 | Very upsetting day. Arrived to fix melitta with a rusted off connector on flow meter. Replaced wire harness and flow meter. Found where leak that killed it was originating from. No problems. Except that the new flow meter arrived DOA!!! Very unfortunate will have to order replacement… |
| 2153 | Brendan | 09/06/2024 | 10622 | -replace Abs Ice gate |
| 2152 | Waylon | 09/06/2024 | 12272 | - cut to fit and weld another piece for closet
-Replaced light ballast by bathrooms
-had to get another ballast from grainger replaced by main entrance vestibule
-cut to fit a tile and grouted
FREEDOOM ALAS |
| 2151 | Waylon | 09/05/2024 | 12272 | -Caulked men’s bathroom toilet
-Men’s bathroom not working replaced bulbs still no good found it to be a bad ballast had to dissemble the whole light through Sheetrock to replace the ballast
-Installed men’s room toilet dispenser
-fixed bottom plate threshold for bathroom side lobby door had to pull up drill concrete put tapcons in and then used concrete crack filler caulk to fill the edges
-Replaced bottom of entrance door sweep strip kinda a hit or miss did it at 8 pm can’t see light through I think it’s good the plate threshold is bent super bad but added too last minute to pull that up and replace
-welded closet doors a new metal plate welds are pretty shit cause it’s aluminum and burns instantly basically so it’s welded and painted over I would say looks pretty good better than a full rusted out door
-Helped Tara paint over it b
-Traveled to kamco to try and get a ceiling tile match they gave me something close didn’t really look to well when I got back gonna try to get one in the morning
-Caulked holes in the wall where tv mount was then put up a sign over them per Michael request
-Caulked frp in back cash around electrical outlet and the new cut to fit frp piece
-Helped Mike in grill fix a dangling sign that was very messed up out of shape
-Replaced muffin toaster power cord and turned on to make sure it’s all set
-Dug up and straightened pull forward sign 5
-Helped Shannon really briefly struggling with taking apart frappe machine bolts
-add a bunch of random side task added throughout the day that didn’t take significant amounts of time that I can’t remember right now
-Spent over half an hour scraping my windshield clean because Kris thought it would be funny to spray goo gone all over my windshield at the beginning of the day and never cleaned it up so the sun baked it on and couldn’t see anything it’s still pretty mid but I wanna go home so not scraping it anymore |
| 2150 | Brendan | 09/05/2024 | 07194 | -troubleshooted grill, two bad SSR on order |
| 2149 | Brendan | 09/05/2024 | 00596 | -Troubleshooted coffee brewer, couldn’t find anything wrong. Ran some pots and “ready” light was lighting as expecting. NTF
-troubleshooted side 2 prep line heater. Working as expected. Switch is good and consistent, element measuring 100ohm and drawing 1.2amp, heating as expected. NTF |
| 2144 | Brendan | 09/03/2024 | 12272 | -removed installed siding
-replaced 6 lobby ceiling tiles
-installed ice machine panels and screw receptacles
-tightened coke tank bolt
-cleaned filter screen at back sink sprayer
-replaced hinge on washing machine door
-replaced curbside sign |
| 2148 | Brendan | 09/05/2024 | 02830 | Troubleshooted melitta. Leak from manifold block caused connector to rust off. On order |
| 2147 | Waylon | 09/04/2024 | 12272 | -Finished siding and predrilled holes for nails then nailed
-Broke apart 2 pallets with saw
-reset toilet had to take all part and install new screws and wax ring wasn’t sitting right so took extra long tested no leaks
-picked up Brendan from tire shop
- talked with Casco guy regarding phantom buttons of the friar and the diagnosis
-started to weld metal for electrical closet but got interrupted from drive through way to many times so gonna wait till tmrw morning
|
| 2146 | Brendan | 09/04/2024 | 12272 | -FRP 1st window
-replaced delivery door plexiglass
-fixed zoom timer
-cut sheet metal for kickplates and grinded doors to bare metal |
| 2145 | Waylon | 09/03/2024 | 12272 | - ripped out old corner and angle grinded parts left over off
-Built a new corner and had to seal it used roofers caulk which is pretty messy so it not the pretties but it’s to keep it sealed from rain and snow
-Samded down the corner boards so it can be painted if it’s wanted
-filled concrete crack that went through the drive through and covered with plywood
-Cold patch asphalt in drive thru stamped it a ton then had Alex stamp a ton since it kills your hands then drove a car over it about 50 times
Built pressure washer for them
-tore out pieces of siding and replaced with new siding all had to be cut to fit and going to have replace one of the new ones tmrw since the nail cracked it as I was leaving 😭
Bought tons of supplies for them like pressure washer and Brendan installed the hinge for washing machine door but locked that up |
| 2143 | Brendan | 09/03/2024 | 02038 | -troubleshooted oj machine leaking water everywhere. Found float switch connector with water ingress causing it to continue filling. New switch on order. Disconnected for now so they can run it
-ordered bump bar |
| 2142 | Brendan | 09/03/2024 | 07194 | -troubleshooted melitta not turning on. Internal breaker kept tripping due to CBO being bad. New CBO on order
-replaced fry hopper power switch |
| 2141 | Brendan | 09/03/2024 | 04205 | -shake machine training buttttt rescheduled because everyone called out…. And the shake barrel has a refrigeration issue….
-coke tank NTF |
| 2140 | Waylon | 08/30/2024 | 10544 | Co2 sign
Door latching mechanism install |
| 2139 | Waylon | 08/30/2024 | 12272 | -Lot of curbing in drive thru that just kept getting hit after doing it ….
-Cut out hole in wall because of electrical problem with window than re dry walked the hole needs frp
-Did a walk through with Michael
Ordered ice machine parts |
| 2138 | Brendan | 08/30/2024 | 00596 | -back door strike loose, tapped hole a size bigger all tight and secure now |
| 2137 | Brendan | 08/30/2024 | 12272 | -cut open wall at first window with Waylon to find old electric wires that causing breaker to trip
-cut away burned bun steamer water line
-replaced FCB condenser fan motor, quiet as a mouse now 🐁
-replaced zoom TSP
-troubleshooted ice maker, wire on sensor broken, Rick coming Tuesday
-cleaned out my boxes |
| 2136 | Waylon | 08/29/2024 | 12272 | -Fixed double light ballast removed old replaced with 4 lamp and required
-Went to install new ice machine parts found one part to be missing so have to order that part which keeps everything together
- installed new light lense and left spare out back
-Diagnosed quarter monitor needs replacement power going into blow but 0 power out of block on opposite side |
| 2135 | Brendan | 08/29/2024 | 07417 | -intermittent issues with lights not turning on in office, crew room, and office. Was able to recreate the issue, it was a tricky one. Wire going to the contactor for the EMS very burned. Luckily there was a spare terminal so I didn’t have to buy a whole new contactor. Cut wires back and attached to spare all working great now
-repaired frayed UHC cord
-looked into many bathroom problems. They will need to call east coast. They said the flush is too short but it is matched up to the required flush for the toilet soooo no idea what they’re talking about |
| 2134 | Brendan | 08/29/2024 | 21582 | -replaced washing machine lid lock, tested all set
-OJ and lemonade just coming out syrup, clogged filter all set |
| 2133 | Brendan | 08/29/2024 | 04205 | -troubleshooted card reader, network cable lost its clip and fell out. Crimped a new connector and also refastened card reader to paddle
-replaced flow control for coke @ ABS and calibrated. All working |
| 2132 | Waylon | 08/29/2024 | 04956 | -Installed new lobby window chain took a little longer than thought first time doing one and testing the sensor out was being a little finicky
-Snacked urinal snake got stuck on a bunch of plastic like a wire brush in there got a chunk out drains now I recommended using some drain O just to fully clear up any left over debris but is def draining |
| 2131 | Brendan | 08/28/2024 | 10544 | -was planning to fix lobby door issue BUT apparently 3rd shift messed with it and lost the strike plate entirely... I redrilled the holes and added rivet nuts so when the new strike comes in waylon will be able to slap it in no problem. 3rd shift will have to deal with it being unlocked until then, luckily its a 24 hr store...
--apparently 3rd shift got angry and punched the fry monitor... So I replaced the screen... |
| 2130 | Waylon | 08/28/2024 | 12272 | -Had to cut out and chisel tile by the co2 tank was basically under the leg so kinda hard to get out with the angle grinder and had to regrout since I didn’t have black grout on me (small little drip in the corner from co2 tank need snail fan)
-Fixed baseboard stock room sticking out into shelves
-Tore out old light that had 2 ballast bad in it and 6/8 sockets were all fried up so it would’ve cost as much to fix as to replace but took a while to tear out cause the ceiling is a jungle
-Installed new light led troffer and ran into a electrical box where it is connected and covered safely
-Installed new light lense outside manager office |
| 2129 | Brendan | 08/28/2024 | 25383 | -replaced sundae side pump motor. Also had to install pump tuneup kit
-replaced leaking prefilter. Had to rework some of the plumbing since the new filter are flow directional, the old ones weren’t. |
| 2128 | Waylon | 08/27/2024 | 18198 | -Ripped up 6 tiles by OJ machine all had small cracks took a little bit since I had to chisel them out
-Tested hand wash sink up front they never use it so it goes into a battery saving mode and takes a little longer to start up once it does it’s all good though
-Jim call back for the outside door latching mechanism Brendan is going today to rivet I set it up so it could lock for tonight but definitely a security issue
- changed out Hi C bib pump |
| 2127 | Brendan | 08/27/2024 | 02038 | -replaced TSP
-troubleshooted lot light breaker, pulling 70amps so definitely a fasttracks problem
-dt lane 1 speaker stopped working while I was there. Seems like the speaker died, Jim from yes! will be here tomorrow at around 9 |
| 2126 | Waylon | 08/27/2024 | 21582 | -Moved office camera for security reasons (did not replace the old tile it was in because there are wires that lead to a electrical box not sure what they go to though)
-Double checked diagnosis on washing machine and ordering new latch switch |
| 2125 | Brendan | 08/27/2024 | 12272 | -troubleshooted FCB being really loud. Bearing gone bad on condenser fan motor, on order |
| 2124 | Waylon | 08/27/2024 | 12272 | -Installed new bun toaster cord
-Fixed co2 problem tested and all running
-Dug up and adjusted the stop sign that was knocked over by Martin browner than rebooted two new bolts than filled back in hole it’s impossible to straighten it with just a shovel that I dug around it with |
| 2123 | Brendan | 08/26/2024 | 25383 | -troubleshooted ice cream pump not pumping, motor drawing 3 amps so it’s popping the overload. Will see if I have an extra at the office tomorrow and be back. If not I’ll have to order.
-troubleshooted oj mix. Booster unplugged and bypassed. It looks like the QMC guy did it so he could turn off the leaky prefilter. I will
Come back during a morning so I can turn off the water to replace the filter head |
| 2122 | Brendan | 08/26/2024 | 02830 | -replaced creamer condenser fan
-fry hopper works fine, just assembled incorrectly. The funnel was popped out of its socket. Also could use a defrost
-attempted repairing drain hose for filter. Was unsuccessful, new breaks just kept showing up, will need to replace the whole line. Job for a different day. Unplugged so it will not keep leaking in the meantime |
| 2121 | Brendan | 08/26/2024 | 10622 | -repaired back door not latching
-replaced breaker and installed/adjusted new breakfast toaster |
| 2120 | Waylon | 08/26/2024 | 12272 | -Diagnosed co2 alarms not working list originally said sniffer but all the alarms are down had to dig through their ceiling because it’s a disaster and found a water leak dripping on to the connection caused the wires to burn up hopefully it didn’t short circuit the alarms and break them all will need to come back tmrw for a part and shroud to cover |
| 2119 | Brendan | 08/23/2024 | 07417 | -replaced Qing oven door switch |
| 2118 | Brendan | 08/23/2024 | 02038 | -reattached door closer to door frame. Had to install rivet nuts but because it has been redrilled so many times I could not drill the holes bigger. So the screws are downsized. Hopefully they will hold up
-troubleshooted zoom timer. Needs a new TSP, on order.
-troubleshooted McFlurry spinner not powering on, loose wire. All tightened up and working |
| 2117 | Waylon | 08/23/2024 | 18198 | -Filet steamer had to take everything apart inside of it to get the cover off replaced a new cord and swapped oep from old to new
-In steamer replaced the water flow tube that crusted away had to grind out hole from build up
-Replaced main board in steamer causing display to flicker |
| 2116 | Brendan | 08/23/2024 | 04956 | -troubleshooted dt window 2. Chain snapped, on order. Trim on door bend causing it not to be able to lock, that’s all fixed |
| 2115 | Brendan | 08/22/2024 | 10622 | -repaired delivery door that was not latching
-replaced 2 kiosk light poles, one kiosk though has a bad button controller so will need to order that |
| 2114 | Waylon | 08/22/2024 | 02830 | -Had to re gap grill it was half slanted when I got there originally was told it was a bad motor popped the top off motor was running perfectly fine so we gave gapping a shot fixed it first try and ran two runs 10:1 didn’t squish any so hopefully that was the only issue |
| 2113 | Waylon | 08/22/2024 | 02038 | Fixed cabinet was receiving power but not turning on ended up being a very finicky power switch all terminals reading 120 as it should but when touching probes cross the terminals turned it on so replaced that working all set
Installed new ballast in grill and rewired |
| 2112 | Brendan | 08/22/2024 | 21582 | -installed new fry station door
-replaced melitta milk pump and grounds container holder |
| 2111 | Waylon | 08/22/2024 | 18198 | Walked in fryer was having problems couldn’t add any oil to vat 1 after drained and was saying service required needed a new AIF board had to crawl underneath get that new guy in than waited for it to heat up and it’s all set still needs LON board disabled but need to shut power off in the AM
-started on filet steamer had to leave cause emergency filet steamer gonna take probably 2-3 hours needs new main board and new power cord and replacing those power cords is a STRUGGLE |
| 2110 | Waylon | 08/21/2024 | 00596 | AGGGG screw this supposed to be an easy above the grill attach to the hood install not a single hole lined up and there was so much grease up there and my drill bits were dull so my arms were slipping and sliding and the drill bits were literally ALL DULL like 🤦🤦 ugh
-replaced power switch in UhC
-Instlaled new bun toaster
-Diagnosed and fixed sink faucet was batteries again stop buying cheap ones
-cut dead tree down and put in dumpster |
| 2109 | Brendan | 08/21/2024 | 04956 | -installed and adjusted new breakfast toaster |
| 2108 | Brendan | 08/21/2024 | 04205 | -put back together shake machine, had to replace shake pump tuneup kit and spinner coupling fell off |
| 2106 | Brendan | 08/21/2024 | 02038 | -ran electrical and installed new breakfast cabinet with waylon
-looked at co2 alarm error. The sniffer died due to automist leaking on it🙃 on order |
| 2107 | Waylon | 08/21/2024 | 02038 | -Has to run new electrical for convi iven first popped off breaker panel took out old breaker double 20 put in a new double 20 ran 12/3 from panel to OEP box in ceiling Brendan did connection for the oep box and set up convi oven while I did all the electrical in the panel
Convo oven is up and running and tested resistance on wires and VAC on oep before plugging anything in for safety |
| 2105 | Brendan | 08/20/2024 | 07417 | -ran cord and replaced music player
-attempted to repair Qing oven but has an obscure proprietary screw, had to order bit for it |
| 2104 | Jim | 08/20/2024 | 10622 | - replaced sink spray head and faucet, also new support for complete setup
- cut and installed two new light lenses |
| 2103 | Brendan | 08/20/2024 | 04956 | -replaced side 2 sink solenoid |
| 2102 | Waylon | 08/20/2024 | 25383 | -Installed new muffin toaster and adjusted color setting to muffin 500 and bagel 300 showed two managers how to operate and clean
-picked up two breakers for Derry tmrw |
| 2101 | Brendan | 08/20/2024 | 10544 | -replaced two handicap buttons
-troubleshooted grill. Just unplugged
-installed Qing oven handle
-hi-c needs new bib pump but I ran out 😒
-OJ is calibrated good NTF |
| 2100 | Waylon | 08/20/2024 | 04956 | Went to work on cabinet closest to Hlz originally thought a board was bad so swapped board seems to fix the problem with one strip plugged in found when replacing the other sides strips it wasn’t the board the menu button was stuck down causing it to only half function
Replaced 4 cabinet strips and one came faulty from factory and I have no more cabinet strips so 3 slots work perfectly fine left bad slot unplugged for time being
-Fixed woman’s restroom toilet flusher the power from the battery in it was frayed off stripped wire wrapped it around electrical tapped it in then tested flushed great then replaced screws on it cause that’s why the whole problem happened people kept taking it off idk why tho |
| 2099 | Brendan | 08/20/2024 | 04205 | -replaced DVR hard drive |
| 2098 | Brendan | 08/20/2024 | 07194 | -looked at fry hopper, new switch on order |
| 2097 | Jim | 08/20/2024 | 00596 | - poured 1/2 gal drain cleaner down men’s room toilet, all cleared |
| 2096 | Jim | 08/20/2024 | 02830 | - sourced and installed light ballast in crew room |
| 2095 | Brendan | 08/19/2024 | 10622 | - Sprite is all set
- both dt windows are all set
- frappe machine leak all set
-installed new breakfast toaster but the breaker is bad so I will be back in a few days to put it in and finish up |
| 2094 | Waylon | 08/19/2024 | 25383 | -Qing oven not heating had a blown out fuse was all black replaced fuse ran 4 test runs cooked all good all 4 times
-Showed Sara and Xander how to use the M/R list
-Went to swap the grill to make 4:1 but Katie already did it so left it all alone |
| 2093 | Jim | 08/19/2024 | 12272 | -sourced and replaced electrical panel cover and caulked around edge as old panel was overall larger |
| 2092 | Waylon | 08/19/2024 | 02830 | -installed new cabinet strip that was said by Shannon to be pealing |
| 2091 | Waylon | 08/19/2024 | 02038 | Disabled nrbes coffee brewer heating plates
-Found out UHC cord was fixed by me earlier in the year
-Went to install enter exit signs found that I only have enter with arrow pointing right and exit with arrow pointing right so both signs would be missing half of it
-found the kitchen sink drain to be cross threaded needs a new p trap and drain can’t deviate from my plan today to fix it |
| 2090 | Jim | 08/19/2024 | 17371 | -replaced the two faucet handles and cartridges on slop sink |
| 2089 | Brendan | 08/19/2024 | 21582 | -replaced cherry expansion tank FCB
-repaired stock door not unlatching
-unclogged frappe condensate drain
-muffin toaster NTF
-troubleshooted espresso machine not dispensing milk. Milk pump bad, on order |
| 2088 | Waylon | 08/19/2024 | 04956 | -Removed fry bulb socket that was stuck inside of it and replaced new fry bulb
Originally went for a new UHC strip but I thought I had some left and guess I didn’t every other strip I got just no arrow strips so ordered some |
| 2087 | Waylon | 08/19/2024 | 07417 | -Replaced switch inside Qing oven then found that the switch was bad and they broke the handle by slamming it so many times it warped the bottom teeth of the handle that tells the Qing oven it’s closed then I have one of those on the van but found out you need a special screw driver for Y screws which Brendan said he has the bit so he’s gonna finish that |
| 2086 | Brendan | 08/19/2024 | 12272 | -turned register on with broken power button
-verified creamer was at temp
-verified all bump bars had all buttons
-replaced fry hopper right side keypad who’s power button was not working |
| 2085 | Jim | 08/19/2024 | 07417 | - cleaned and remounted trim above windows in lobby |
| 2084 | Jim | 08/16/2024 | 07417 | - snaked drain seems to run ok now
- worked on lobby trim need extra set of hands due to limited access
|
| 2083 | Jim | 08/16/2024 | 10544 | - grouted by time clock
- replaced 4 white wall tiles and grouted
- grouted in front of fry vats
-Painted where the sign board was at drive thru |
| 2081 | Brendan | 08/15/2024 | 12272 | -replaced bun toaster fan
-troubleshooted cream dispenser temp. It was set all the way warm, lowered it and will wait to see if it comes down
-brought in new drive thru window and checked for damage
-ordered ice machine top panel, front panel, and both screw receptacles (backordered) |
| 2080 | Jim | 08/15/2024 | 02830 | - grouted the lobby wall
- took pictures of the roof latch for Brendan |
| 2079 | Brendan | 08/15/2024 | 07417 | -realigned ice machine bin with drain
-looked for leak in SSBS. slow drain, will send Jim tomorrow |
| 2078 | Jim | 08/15/2024 | 10544 | - removed sign board on drive thru side , getting paint for it
- replaced three floor tiles by sink and grouted
- installed 6 base tiles behind syrup rack and grouted
- repaired roof drain pipe and added bracket to standpipe
|
| 2077 | Brendan | 08/14/2024 | 18198 | -installed new muffin toaster |
| 2076 | Brendan | 08/14/2024 | 17371 | -replaced lid lock washing machine
-replaced filet steamer display
-repaired lobby door hard to turn key to unlock. Mechanism all gunked up.
-replaced kiosk 6 scanner
-leak behind frappe machine, espresso machine hose was not in drain |
| 2075 | Jim | 08/14/2024 | 10544 | - grouted area around ice maker and prep sink |
| 2074 | Jim | 08/14/2024 | 02038 | - Removed and filled 7 well lights
- grouted by frappe machine
- secured lobby closet frame, door slab needs replacement 78” H X 36”W
LH swing |
| 2073 | Brendan | 08/13/2024 | 02830 | -replaced D51 and its wiring harness, ACS calibration
-installed second grill bump bar
-looks like RHS had ADjoin issues, being weird, might just reimage it after I make a drive
|
| 2072 | Brendan | 08/13/2024 | 02038 | -disconnected well lights from breaker
-tried to figure out the mess in the light control panel. Controller is bad
-have ABS a much needed tune up. Grabber arms bent outward causing grip issues, calibrated sensor, replaced a bunch of cup fingers. |
| 2071 | Jim | 08/13/2024 | 21582 | - picked up and installed new men’s room mirror |
| 2070 | Jim | 08/13/2024 | 12272 | - added pipe to connect to roof gutter
- wire brushed base of welcome sign and repainted
- curbing by drive thru done
- grouted under ice bin, no worm issue |
| 2069 | Jim | 08/13/2024 | 00596 | - filled cracked with.mortar at drive thru area
- cut and installed wood ceiling tile in lobby |
| 2068 | Jim | 08/12/2024 | 07417 | - removed well lights and filled holes with sand& concrete
Nine lights in total |
| 2067 | Jim | 08/12/2024 | 04956 | -cleared urinal drain clog, with chemical and plunging |
| 2066 | Brendan | 08/10/2024 | 04956 | -replaced oven door latch
-cut and installed fry bulb grate
-replace ice cream pump o ring |
| 2065 | Brendan | 08/10/2024 | 00596 | -replaced cash drawer pos15 |
| 2064 | Brendan | 08/10/2024 | 04205 | -troubleshooted ABS coke issues. Bad flow control definitely but was able to adjust it
-replaced and adjusted cup tube fingers
-McCafé fridge kept tripping plug, bad gfci. Just put in another outlet |
| 2063 | Brendan | 08/10/2024 | 07194 | -installed run capacitor for multiplex and wired back up
-window 2 NTF |
| 2062 | Brendan | 08/10/2024 | 07417 | -disconnect well light circuit so they can be cemented in |
| 2061 | Jim | 08/09/2024 | 21582 | - removed mirror for repair
- hole in present area already filled
- sent pic of turn sign sent to Brendan
- in house Maintenance did ceiling tile ( gave him four more)
|
| 2060 | Waylon | 08/09/2024 | 07194 | -Replaced nugget fryer cord wasn’t bad just a massive electrical cord and had to take some stuff off the old cord got slimed by grease a couple times but made it out alive all set and running |
| 2058 | Jim | 08/09/2024 | 25383 | - reattached wallpaper on crew room window
- taped and painted top of crew room window frame
- installed cover over wallpaper hole |
| 2059 | Jim | 08/09/2024 | 10544 | - removed and replaced wall tile in men’s room stall |
| 2057 | Waylon | 08/08/2024 | 25383 | -Well this was interesting grill platen down no power at all I just assumed they were being dumb and a plug or something simple nope was receiving power traced it through the whole system found a bad computer which is really surprising cause those don’t go bad often I had one in my van but it’s got old programming on it works for 10:1 and breakfast stuff but doesn’t have any quarter, so Brendan’s checking if we can buy a software update usb or if it’s too outdated and need a new computer. Had to swap the speaker from the bad computer to the one I have since we used that part from it in the passed
-Installed second quarter monitor bump bar
-Disabled coffee breweries heat per nrbes
Checked breakers and took what we need to order for new oep to go in all new electrical |
| 2056 | Brendan | 08/08/2024 | 02830 | -melitta error again. I was wrong last time. The impeller is bad. The connector broke off of it so it was detecting water usage. On order |
| 2055 | Brendan | 08/08/2024 | 02830 | -installed replacement parts for multiplex and had to recrimp lots of connectors. Neglected to realize that there was a bad run cap…. On order |
| 2054 | Waylon | 08/08/2024 | 10544 | -Ordered a new handle for Qing oven since they lost the screws for it… would’ve ordered ahead of time if they added to list
-Replaced Qing oven cord and OEP was burning inside OEP why it was smelling bad tested one burrito cooked all set and fine visually inspected inside for burning on any terminal was all set
-Grouted 5x10 tile area around ice bin drive thru then they spilled water on it so had to fix half of it has set but it’s still a little wet in the area requesting they order an ice bin cover since they don’t have one causing ice to sit and melt on the side ruining grout
-Took mirror since it had graffiti on it
-HLZ breaker was tripped and the breaker panel itself was falling off the wall had to make a trip to Home Depot for breaker panel screws since I can’t leave this off if someone on accidentally stuck their hand under the table and got zapped would’ve been bad
-Visually inspected tiles with graffiti Jim was supposed to come out and do Brendan had me double check found one spot to the left side of the toilet and took the mirror
|
| 2053 | Jim | 08/08/2024 | 12272 | - repaired crack along length of drive thru side
- rebuilt curb by drive thru door |
| 2052 | Jim | 08/08/2024 | 02038 | - filled multiple cracks by play place & drive thru side walkways |
| 2051 | Jim | 08/08/2024 | 07417 | -cleaned and repaired cracks and a hole in corral concrete pad |
| 2050 | Brendan | 08/07/2024 | 25383 | -installed staging cabinet. Stole one of their Qing oven plugs for now, will come back to run a new OEP after NRBES stuff is over
-replaced UHC monitor
-looked for leaks BIM. unit was tilted forward causing it. All set |
| 2049 | Jim | 08/07/2024 | 12272 | - repaired concrete by drive thru, on parking lot sidewalk, and by drive thru railing
- repaired FRP
- caulked around both capped pipes on side two wall
- removed 24 hour sign and installed electrical box for wires
|
| 2048 | Waylon | 08/07/2024 | 17371 | -Replaced dt runner monitor
-fixed bump bar cable and took bad bump bar serve button is stuck down
-Hung co2 alarm sign up
-Ordered part for washing machine bad latch switch from the looks of it
-Looked at freezer door hinges the adjustment screw is stripped Brendan told me to let Rick deal with it
-Ticket for prep fridge leaking pulled it out looked behind no water it drips a little when you move it out and back but that could just be regular condensation or melted ice
|
| 2047 | Jim | 08/07/2024 | 02830 | - painted enter sign
- filled hooked no wall between hand sink & fry hopper
- sourced and replaced hand sink trap
- painted ladies room door repair and men’s room stall door
- remounted walk in threshold
-applied caulking at front counter next to shake machine |
| 2046 | Brendan | 08/06/2024 | 02830 | -replaced RHS
-set up xclarity for both servers
-repaired McCafé machine, ran through cleaning cycle, and tested
-troubleshooted kitchen screens not beeping. Speakers blown, on order
-troubleshooted creamer temp, lots of frost build up and a bad fan motor, on order |
| 2045 | Waylon | 08/06/2024 | 25383 | - replacing enter exit signs supposed to be very very easy like takes maybe 10 minutes tops per sign I’ve done it before easy peasy well thanks to Milford’s sign frames being bent out of shape AND the company sent signs 1/4 inch to big for the frame so had to cut to fit 3 out of the 6 signs which was free hand with the angle grinder and those signs are like 250$ a piece so very scary mistake if I messed up
Anyways got those in took had to be hours a lot of beating with a wrench and physically exhausting myself from pushing and pulling it in
-Looked at ice machine drain backing up wasn’t the drain at all looks like the water line is not popped out of the water reservoir causing the water to just spray everywhere and leak down the back side of the abs causing it to seem like it was the drain
- while looking into drain found the abs staging tray wasn’t even in the drain so also could’ve easily led to the problem
Barely touched my list of things to fix in this store cause of these 2 stinky stupid things 😡🤬 |
| 2044 | Brendan | 08/06/2024 | 07194 | -troubleshooted flat soda. Multiplex start relay melted. Looks like it was due to a bad fan motor drawing too much amps. Parts on order |
| 2043 | Brendan | 08/06/2024 | 07417 | -replaced burst tea water line |
| 2042 | Jim | 08/06/2024 | 04205 | - sourced and replaced toilet spud nut assembly and re installed toilet pipes |
| 2041 | Jim | 08/06/2024 | 12272 | - installed new bulbs in light above drive thru 2
- grouted in front of sink
- grouted in front of and under ice bin
- grouted by slop sink
-capped off two pipes in wall
- replaced lobby ceiling tiles
|
| 2040 | Waylon | 08/06/2024 | 07194 | -Installed quarter screen second bump bar which took an extended amount of time since drilling it in snapped 2 tapper bits and stripped 3 screws…
-Got model number and cord awg for Brendan to order
-picked up 2 monitors from crew room
|
| 2039 | Waylon | 08/06/2024 | 18198 | -bump bar button was stuck down bunch of stuff has been spilled on it swapped with side 2 for the time being
-Order new mix bin for co29 |
| 2038 | Brendan | 08/05/2024 | 18198 | -installed mini-orb components
-replaced kiosk 6 scanner
-installed pos15 scanner |
| 2037 | Waylon | 08/05/2024 | 00596 | -Fixed back sink not working
-Found a tile need a saw to cut it so stopping by tmrw
-Tighten woman’s sink
|
| 2036 | Brendan | 08/05/2024 | 04956 | -installed two scanners in dt
-replace scanner pos2
-oven latch missing, ordering replacement
-ordering replacement ice machine cover
-ordering replacement fry bulb grate |
| 2035 | Waylon | 08/05/2024 | 21582 | -installed new bottom cabinet strip side 2 was flaking off per NRBES visit
-Installed a second grill monitor bump bar had to create a daisy link cable for it also had to fix the original grill bump bar cable was becoming super frayed |
| 2034 | Jim | 08/05/2024 | 25383 | - reattached wall paper in crew room
- scraped window area and applied joint compound in crew room
- tightened front monitor bracket
- check lobby for loose stool found none |
| 2033 | Jim | 08/05/2024 | 10544 | - replaced theee ceiling tiles in crew room
-installed new pipe covers in men’s room sink
- no graffiti found in men’s room
|
| 2028 | Jim | 08/05/2024 | 02830 | - taped off exit sign and spray painted the post and frame black
- filled holes in tile by 10:1 freezer
- fastened walk in and freezer thresholds
- removed graffiti from men’s room wall
- repaired women’s room door
- filled holes in office FRP |
| 2032 | Brendan | 08/05/2024 | 00596 | -looked for leaks in front dt. Nothing coming from equipment. It looks like it’s all coming up from cemented drains
-repaired kiosk 6 scanner |
| 2031 | Waylon | 08/05/2024 | 10622 | -Looked into grill error open probe tested all the probes average was 13.6 ohms the top was 16.7 all look fine screwed down tight and double checked ribbon cables all look good so should be fine they’ve been using it all morning
-Installed 3 new tiles had to break 2 up with hammer went super slow and angle grinder the last out
-Took pictures of enter exit sign for Brendan |
| 2030 | Brendan | 08/05/2024 | 04205 | -fixed register power button not working
-replaced printer 14 with printer 2 because I’m not giving them new stuff
-McCafé fridge plug just tripped |
| 2029 | Brendan | 08/05/2024 | 02830 | -RHS down. Power supply went bad. Overnighting new server. Was able to add lunch items back from outage though |
| 2027 | Brendan | 08/04/2024 | 10544 | -replaced dt present monitor
-replaced root beer bib pump
-looked for leaks in dr put couldn’t find any. Replaced a kinked section of hose
-got details of enter/exit signs
-get details for fry station doors
-repaired root beer lobby valve
-disabled coffee warmers
-noticed handicap button barely hanging on. Missing screws and holes stripped out. New push plates on order |
| 2026 | Brendan | 08/02/2024 | 04956 | -replaced Fanta bib pump
-replaced milk nozzle mccafe |
| 2025 | Brendan | 08/02/2024 | 21582 | -replaced washer inlet valve |
| 2024 | Waylon | 08/02/2024 | 04956 | Ice machine said wasn’t making ice went there watched it drop ice 2 times adjusted ice thickness probe since it seemed like half the ice fell into the water reservoir from being to thin to go into the bin |
| 2023 | Brendan | 08/02/2024 | 04205 | -gray water, replaced filters and unplugged booster |
| 2022 | Brendan | 08/02/2024 | 02830 | -first time diagnosing melitta. I believe it is a bad tamp. Will order |
| 2021 | Waylon | 08/02/2024 | 12272 | New co2 alarm
Set up snail fan under ice bin to keep everything bone dry |
| 2020 | Waylon | 08/02/2024 | 04956 | Training gym on bulk ice machine pm |
| 2019 | Waylon | 08/01/2024 | 12272 | -Geill Pm with Brendan
- had to fix abs drain that was leaking from pan and from the kinked hose that overtime broke (soda went everywhere was a mess got covered in Fanta great day
-replaced oring for dish sink so it would hold water wasn’t a perfect match but seemed to hold water pretty well compared to before
|
| 2018 | Jim | 08/01/2024 | 18198 | - repaired main sign post and primed |
| 2017 | Jim | 08/01/2024 | 17371 | - replaced batteries in ladies bathroom small stall toilet
- checked fry socket, all good, just changed bulb
- repaired damaged corner of building at drive thru 1 |
| 2016 | Brendan | 08/01/2024 | 12272 | -right grill PM
-adjusted ABS index sensor |
| 2015 | Brendan | 07/31/2024 | 07194 | -basically rebuilt entire water booster what a project
-looked at ice machine leaking. Pipes not lining up with drain, store will have to let machine run empty and move the bin back.
-adjusted hand wash sink temp |
| 2014 | Waylon | 07/31/2024 | 00596 | - finished installing new light had to take it out rerun cable to it than wire into a box and finally connect the wiring in the box to power than cover box also straightened out ceiling grid
-Abs leak was coming from the drain for the drain pan tightened the fitting it was beyond disgusting underneath it so got what I could off with a linen so I could work on it I ran water had no leak but there’s a ton of extra fittings where there shouldn’t be so I told Laurel to keep Brendan posted just in case |
| 2011 | Waylon | 07/30/2024 | 18198 | -Replaced monitor for beverages
-Wired in and replaced a new cord for frappe machine
-Looked at ice gate for lobby ice machine with Brendan
-a light broke while I was there went to store ti install one after wiring directly into it from ceiling found out that due to wire sizes you’re supposed to wire it from ceiling to box and box to light future and the light wasn’t fitting properly into the grid so became a whole project I left it wired in so they would have light going back next day to fix properly |
| 2013 | Jim | 07/31/2024 | 10622 | - installed new window handle at drive thru 1
- re installed caster wheel on bun rack
- color matched building and corral colors and dropped off six gallons of paint
|
| 2012 | Brendan | 07/31/2024 | 04956 | -programmed round egg clams |
| 2010 | Jim | 07/31/2024 | 00596 | - sanded men’s room stall door
- re mounted window sill on drive thru side vestibule |
| 2009 | Brendan | 07/30/2024 | 07417 | -replaced left barrel expansion tank |
| 2008 | Brendan | 07/30/2024 | 00596 | -FCB replaced middle barrel expansion tank. Added service loop since they aren’t nice enough at the factory to do that lol |
| 2007 | Jim | 07/30/2024 | 04956 | - cleared clogged urinal, drains but slowly. Had quite a mess to clean up
- hung two letter holders for Mike in the office |
| 2006 | Brendan | 07/30/2024 | 21582 | -troubleshooted washing machine leaking water everywhere. Pinhole leak in inlet valve. Replacement part on order should be there tomorrow |
| 2005 | Waylon | 07/30/2024 | 02830 | -Qing oven no power at all, wasn’t a hard diagnosis it was a bad 30 amp fuse I skipped the fuses to begin so took a minute to get back to since I was following voltage through ti see where it dropped it but when checking the fuses by putting the two meter prongs across the fuse it read voltage but the fuse was blown anyways had to go to store for the fuse and bought extra for van stock
Tested 2 times before leaving |
| 2004 | Brendan | 07/30/2024 | 02038 | -diagnosed alll the water issues:
1. Multiplex heavily condensating. Front panel bowed out may be indicative of a crack. Regardless insulation is so deteriorated causing it to condensate. Not fixable, only solution to replace.
2. Ice machine on top of ABS rotted out so it does not have the bracket to keep the door on tight and keep the water in. Don’t believe this is fixable but store can ask Rick for opinion.
3. ABS ice bin heavily condensating causing pooling and leaking underneath. It is possible but expensive to fix. In limbo right now.
4. Fridge in drive thru dripping water, store to call Rick.
5. Water dripping from ice bin scoop and ice bin also a contributing factor, though nothing can be done about that |
| 2003 | Jim | 07/30/2024 | 25383 | - installed new spray nozzle at left side sink faucet
- ran snake at ABS system, hit something at about 8-10 ft and punched thru ran five more feet, no resistance. Turned on ice maker no leaks
|
| 2002 | Brendan | 07/29/2024 | 04956 | -ABS was just missing washers. All set |
| 2001 | Brendan | 07/29/2024 | 02830 | -troubleshooted washer. Watched for multiple loads, ran diagnostics mode. Diagnostics came up with no errors. There were also no errors previously. Loads ran as expected not tripping breakers and completed just fine. NTF |
| 2000 | Waylon | 07/29/2024 | 04205 | -Had to replace 6 custom baseboard tiles which there was no wall to put on so had to spray foam in a back board and then cut that down
-Had to replace one floor tile that had water on it but didn’t wanna come up and it was behind the washing machine so wasn’t much room to work
-Replaced all tiles then grouted everything |
| 1999 | Jim | 07/29/2024 | 10544 | - sourced post and sign and installed new # 2 drive thru sign |
| 1998 | Jim | 07/29/2024 | 25383 | - cleaned and epoxied frappe machine drain hole and crack
- found all parts to repair spray nozzle on left side of sink
|
| 1997 | Brendan | 07/29/2024 | 07417 | -troubleshooted FCB leaking. Burst cherry expansion tank. Extra one from south willow coming in tomorrow. |
| 1996 | Brendan | 07/26/2024 | 10544 | -troubleshooted frappe water. Dialed regulator down and replaced armature
-replaced fry hopper compressor relay
-hlz side 2 breaker was just off
-dish sprayer already fixed
-replaced ped13 |
| 1995 | Brendan | 07/26/2024 | 04205 | -investigated leak by dish sink, opened up wall and determined it to be caused by ice machine leaking and running under the wall
-outlets in lobby not working, gfci tripped |
| 1994 | Jim | 07/26/2024 | 00596 | - cleared lobby drink station drain issue |
| 1993 | Jim | 07/26/2024 | 12272 | - counter tile replaced & grouted
- lobby wall tile installed &grouted
- filled hole with cold patch in front of the corral
- filled cracks in cement at drive thru area
- filled broken concrete at drive thru entrance |
| 1992 | Waylon | 07/25/2024 | 02830 | -went for qingoven not counting down
It was counting down it just randomly stops like super random I went through 5 cook cycles and it didn’t stop once so it’s super inconsistent I am making an assumption on the diagnosis because realistically theirs nothing I can test for this problem until it because faulty regularly it’s just a hypothesis right now I put in a new button panel because I believe it has a faulty stop button which pauses the timer cause then you can hit resume and it resumes fine so I assume that’s the problem
-While diagnosing found the door switch is starting to go bad so installed a new door switch (with relay board)
|
| 1991 | Brendan | 07/25/2024 | 07194 | -ran wire and installed another eproduction monitor above grill
-replaced side 2 monitor |
| 1990 | Waylon | 07/25/2024 | 00596 | -Insralled new ice bin with Brendan was pretty hard taking it apart and out but the new bin went in pretty smoothly
-Looked into GFCI outlet not having power making the assumption that somewhere in the ceiling it got grounded since it’s receiving power from panel but getting stopped somewhere
-Ime monitor for McCafé is dead needs to be ordered receiving 120 but no power |
| 1989 | Brendan | 07/25/2024 | 00596 | -replaced SSBS ice bin with Waylon, what a massive pain.
-troubleshooted FCB leaking coke, bad expansion tank on order.
-replaced optional flavor air solenoid shake machine
-reaffixed printer sled to front counter
-fixed NVR not connecting to app |
| 1988 | Jim | 07/25/2024 | 12272 | - cleaned, taped and caulked sink and backsplash
- installed door sweep and latch side weather stripping
|
| 1987 | Jim | 07/25/2024 | 04205 | - checked ladies and men’s room toilets for leaks, none found
- spray foamed abandoned pipe on floor by front hand sink
- grouted under hand sinks on floor
- cleaned under lobby drink station and put air dryer under cabinet
- re mounted drop at second drive thru
- installed pins in FRP by Drive thru two window |
| 1986 | Brendan | 07/24/2024 | 07417 | -dr pepper not working right, just a lot of air in line since bag was kind of caved in
-screwed office door hinge in with longer screws so it doesn’t drag on the floor
-replaced cash drawers 1 and 13 |
| 1985 | Brendan | 07/24/2024 | 04205 | -looked for leaks under SSBS. found three causes. Old insulation on drain lines, old insulation on drain troff, and the main cause a cracked ice bin on ice dispenser. Will not be repairing but will have Jim put a snail fan under there tomorrow when he is here
-repaired leaking smoothie water line
-attempted to repair push bar outside knob not working. Unsuccessful. It’s some obscure door knob with off center mounting holes that they probably don’t make anymore. Technically it’s supposed to be a dummy handle anyway. Will not be repairing
-looked at water “not draining all the way”. The water being referred to is the trap. Water is supposed to always be there to prevent sewer gas from escaping |
| 1984 | Waylon | 07/24/2024 | 02038 | -instaled new drain hose for multiplex was a pain to reach and get to since it was all moldy and gross underneath some swears were said…
- installed egg crate above drive thru window 2
-Fixed McFlurry mixer cord was frayed replaced and was a pain to wire since only one hand could fit inside it and random terminals kept breaking
-Broke up 2 tiles and regrouted 3x3 area around
-Removed ketchup in lobby had to rip out all the lines and tried taking the bolts off to the valves literally wouldn’t budge at all pulled out the 12 inch wrench and didn’t do anything so resolved the problem with the angle grinder left small marks can be buffed out if they really want this ketchup took a fat minute to do and then I had to go back and clean up the area from ketchup |
| 1983 | Waylon | 07/23/2024 | 04205 | Snaked floor drain did not need to be snaked the drain is at it’s set water level cause that’s where the P trap begins it’s perfectly fine you can dump a bucket of water down it and drains fine
-Looked at leak under ssbs I’m not seeing anything that’s insane Brendan’s gonna take a look cause rn it’s just a massive optical illusion I believe the lines above the back right corner are slowly dripping from the lines sweating but Brendan’s gonna double check my thesis |
| 1982 | Brendan | 07/23/2024 | 12272 | -water line leaking by booster, replaced line all fixed
-installed new flagpole door
-fixed grill slips
-paired ped6
-mccafe fridge not turning on, tripped plug |
| 1981 | Waylon | 07/23/2024 | 10622 | -Installed new power cord for frappe machine
-installed new button for grill black standby
-Had to remove 2 ballast in one light and replaced with 4 light ballast had to rewire the whole thing so took a minute
-Resecured wall with a screw then put liquid nails on the side so the screw can come out in the future
-another part of the front has an air bubble in it which upon further investigation found the frp piece is just a little to big for the area but its behind the machines so no one will ever see it |
| 1980 | Jim | 07/23/2024 | 00596 | - replaced door closer on vestibule interior door
- poured hot water down ABS front drain, four times and used air pressure to help clear. |
| 1979 | Jim | 07/23/2024 | 07417 | - grouted behind front coffee counter, in front of fry station& hand sink,in front of kitchen fryer, and by CO2 tank |
| 1970 | Brendan | 07/18/2024 | 02038 | -looked for leak by multiplex. Unit has lots of condensation but also somehow the drain tube is completely missing
-removed broken fry bulb from socket
-noticed co2 alarm no power. Tripped breaker |
| 1978 | Brendan | 07/22/2024 | 10544 | -fixed all problems with lobby push bars One of the push bars one of the mounting screws was stripped so it fell out and jammed itself in so you couldn’t push the push bar. I put a rivet nut on so that’s all set Then on two of the push bars, the mounting holes were drilled like 1/4” off so when you pushed the push bar it the end cap would bind up against the right side mounting bracket so it was hard to push and unlock. Had to shim the end cap out with washers. Not ideal unfortunately but it works.
-hand sinks NTF. All working and accessible
-troubleshooted fry hopper not cooling. Relay was stuck. Tapped to to get it unstuck but not sure how long in will last, on order |
| 1977 | Brendan | 07/22/2024 | 07194 | -lobby ice machine leaking NTF
-care reader unplugged plugged back in
-mccafe fridge has water in it not the machine, store can ask Rick |
| 1976 | Brendan | 07/22/2024 | 10622 | -repaired back door that would not unlatch
-repaired drp lobby valve
-installed scanner window 2 |
| 1975 | Waylon | 07/22/2024 | 04956 | -Installed 2 new contactors in fry vat 1 and 2 and yes I had to whip out like every tool in my van all for different screws and yes I was covered in grease from head to toe and yes my hair now looks like I dumped a bottle of hair gel in it from grease wooohooooo happy Monday!!
Was a good learning experience on friars though |
| 1974 | Brendan | 07/22/2024 | 17371 | -troubleshooted ABS grip fail, syrup shorting out connector. All cleaned up and working. Also replaced missing/broke parts cup location spring, conveyor deflector, and grip pad
-realigned freezer door hinge so closes properly now
-frappe machine drain was cleared before I arrived |
| 1973 | Jim | 07/22/2024 | 07417 | - cleaned and grouted floor area from rear hand wash sink to washing machine
- cleaned and grouted floor area up front fromshake machine to present window |
| 1972 | Waylon | 07/19/2024 | 02038 | - Grill was not heating up to temp at all looked in found a frayed wire coming from contractor the relay wasn’t receiving 208 which means it’s not gonna work so no heat = no grill
-Repalced frayed wire with terminal than the contractor block T1 screw was destroyed no flat head at all so had to replace the contractor than was all set
-Electrical taped a wire off for there extension cord to McFlurry mixer that shouldn’t even be an extension cord so they added it to the list for a new cord I don’t have time today to get to it |
| 1971 | Jim | 07/19/2024 | 12272 | - installed delivery door bottom sweep
- grouted ladies room door frame on both toilets
- caulked slop sink
- replaced lobby ceiling tiles
- repaired sidewalk tripping hazards |
| 1969 | Waylon | 07/18/2024 | 04205 | Co2 alarm signs screwed all in and mounted 2 new ones |
| 1968 | Waylon | 07/18/2024 | 10622 | -Installed new light ballast in back stock room sadly had to do it live since none of the breakers were turning it off
-installed co2 alarm signs for 2 alarms
-Installed muffin toaster bindings |
| 1967 | Jim | 07/18/2024 | 12272 | - installed sheet metal over unused cup dispenser
- installed weather stripping on delivery door
- installed screw in nugget freezer to hold shelf
- replaced the following tiles
4 for tiles by shake machine
3 for tiles by perp sink
1 baseboard tile on side 2
3 baseboard tiles by rear freezer door |
| 1966 | Brendan | 07/18/2024 | 02830 | -front monitors not working after spilling iced coffee urn. Tripped outlet |
| 1965 | Brendan | 07/18/2024 | 00596 | -completed setup and aiming of cameras
-troubleshooted chocolate syrup. Bad solenoid on order |
| 1964 | Waylon | 07/18/2024 | 04956 | -Learned troubleshooting friars with Brendan was 2 bad contractors
-Replaced grill board had to swap for platen 1 Brendan moved the speaker over between boards and I swapped out |
| 1963 | Brendan | 07/18/2024 | 04205 | -replaced print head FFLS
-corrected co2 central unit to show correct number of sensors
-frappe water not working, was just unplugged |
| 1962 | Brendan | 07/18/2024 | 04956 | -troubleshooted fryer teaching Waylon
-replaced speaker and swapped platen 1 controller |
| 1931 | Jim | 07/11/2024 | 04956 | - applied duct seal to conduit for roof cameras
- grouted by fry station and back sink |
| 1961 | Brendan | 07/17/2024 | 07417 | -replaced ABS syrup diffuser
-installed eproduction printer
-troubleshooted espresso machine not working. Found connector on cord was broken, likely due to the cord being so short. Installed longer cord and new connector |
| 1960 | Brendan | 07/17/2024 | 04205 | Label maker NTF |
| 1959 | Brendan | 07/17/2024 | 10544 | -replaced frappe machine drain pan and installed 90
-replaced leaky frappe machine regulator
-replaced ORB scanner and touch screen
-replaced cracked ABS turret door
-installed second grill bump bar |
| 1958 | Waylon | 07/17/2024 | 00596 | -Finished installing two outdoor cameras took a while and a 2 foot drill bit to get through the wall was a mess and 85% sure I destroyed the chuck on my drill so that’s fantastic means gonna need a new drill most likely
- looked into door closer slamming the doors having a new one ordered since it’s got grease coming out of it
-Looked at 2 OEPs not having 208v only read like 10 volts meaning either both wires aren’t touching in the OEP or breaker looked into breaker panel found them to both be tripped…. The store should he capable of checking a tripped breaker |
| 1957 | Jim | 07/17/2024 | 12272 | - filled two pot holes in drive thru by first window |
| 1956 | Jim | 07/17/2024 | 07417 | - snaked ladies room toilet, all clear flushes fine
- grouted under the shake and frappe machines |
| 1955 | Brendan | 07/17/2024 | 25383 | -repaired cracked water line causing flood
-noticed cracked co2 line causing leak, repaired
-replaced pos1 scanner
-replaced abs large cup finger
-adjusted and cleaned window 2 sensor |
| 1954 | Jim | 07/17/2024 | 04205 | - finished trash door frame repair and installed new weatherstripping
- replaced multiple lobby ceiling tiles
- re set ceiling lite. In Drive thru vestibule
- replaced sink spray flex hose |
| 1953 | Waylon | 07/16/2024 | 00596 | This sucked, installed new camera back cash installed a camera by the front door and the last side walk camera my drill bit got stuck in the wall and I gave up so hungry and mad that it’s a tomorrow problem |
| 1952 | Brendan | 07/16/2024 | 04205 | -Oj not getting water. Clogged filters, all set |
| 1951 | Jim | 07/16/2024 | 04205 | -replaced 8 floor tiles by back fryer
- tightened men’s room toilet to floor
- attached sheet metal to men’s room wall tile
- rebuilt trash door frame
- installed two lot light pole covers
- replaced ladies room toilet flush handle
- purchased and dropped off two cases of ceiling tiles |
| 1950 | Brendan | 07/16/2024 | 12272 | -abs arm not lifting. Realllllyyy bad lift cylinder. Had to run to office to grab part then installed
-replaced kiosk 6 controller |
| 1949 | Brendan | 07/16/2024 | 07417 | -frappe breaker keeps tripping; drain clogged causing it to leak into the electrics. Unclogged drain pan but unit will need to remain off until tomorrow to dry out |
| 1948 | Brendan | 07/16/2024 | 18198 | -recrimped bump bar cable
-was going to fix latch for freezer but cannot because store doesn’t have any keys🤦🏻♂️🤦🏻♂️ |
| 1947 | Waylon | 07/16/2024 | 04956 | Installed new fry socket metal contractor broke of in old and the power line terminal was snapped off would’ve replaced the whole cord if I had more time but Shannon was gonna be there so was quickly finishing |
| 1946 | Waylon | 07/16/2024 | 18198 | -Installed new gromet on qing oven so wires aren’t sticking out |
| 1945 | Brendan | 07/15/2024 | 04205 | -ABS was working fine when I got there. Must’ve just had to pass a kidney stone |
| 1944 | Waylon | 07/15/2024 | 21582 | -Went to fix the bolt on the enter exit sign well got there found 2 bolts to be broken off than went to remove the sign to weld 2 new bolts on than the other 2 broke so that was amazing spent the whole day welding the bolts on which was a pain in the butt also welding in the sun you can’t see the welding bead so basically did it blind folded too I told Brendan we should put a mini concrete pad where the welds are since that will make it more secure but it’s done and Shannon (corporate) can’t whine about it |
| 1943 | Brendan | 07/15/2024 | 04956 | -installed dt camera monitors
-installed wire chase and biscuit box to clean up wires at 1st window
-installed wire chase to clean up wires at headset base station
-reattached label maker cutter |
| 1942 | Jim | 07/15/2024 | 10544 | - installed new push bar on rear door
- replaced ladies room sink drain pipe
- installed weather stripping on exit door
- reconnected roof drain pipe |
| 1941 | Brendan | 07/12/2024 | 00596 | -OJ machine having issues, filter clogged. All set |
| 1940 | Brendan | 07/12/2024 | 02038 | -ABS NTF |
| 1939 | Brendan | 07/12/2024 | 04956 | -breakfast cabinet install. Had to run to supply house to get new breaker as well
-installed 2nd LCM bump bar |
| 1938 | Waylon | 07/12/2024 | 04956 | -replaced cord for new breakfast cabinet swapped to a 12/3 it’s proper cord found in OeP hot wire not even tightened into the OeP….. 🤦🏻♂️
-Installed new display board until grill and Brendan took old to replace the speaker in it |
| 1937 | Jim | 07/12/2024 | 04956 | - worked with Brendan
To install new breakfast oven system |
| 1936 | Waylon | 07/11/2024 | 18198 | -Had to replace the whole dish sink setup for sprayer and faucet from wall had to go out and source parts since it was an outdated setup the part we ordered for them needed a bunch of changed fittings just to work and the whole thing was anchient so made more sense to replace it all
It’s chrome and very pretty when I installed it…. |
| 1935 | Waylon | 07/12/2024 | 18198 | -Side 2 sink was leaking cause some idiot put plumbers putty all of it and the gasket and the tightening ring which is genius cause plumber putty doesn’t smooth out when you CROSS THREAD the whole thing 🤯🤯 like let the people who know what they’re doing fix it anyways leak tested works all set had to replace the whole drain cause they cross threaded it and destroyed the metal
-Dish sink out back gasket came loose as I was walking out fixed to told them if it happens again today lmk I’ll replace the gasket and resilicon
-Replaced 30 amp OeP for bun toaster
-Disabled coffee brewers heat plates per nrbes standards |
| 1934 | Jim | 07/11/2024 | 10622 | - cut and installed new light lens in grill area |
| 1933 | Jim | 07/11/2024 | 17371 | - purchased and put together new power washer
- found breaker for front counter outlet
- installed new toilet paper dispenser in ladies room |
| 1932 | Brendan | 07/11/2024 | 21582 | -finally fixed ABS. Had to replace display 1 and BI board. Never have I gotten so many defective parts from the factory…
-repaired McFlurry mixer. Replaced motor assembly and momentary button |
| 1930 | Brendan | 07/10/2024 | 04956 | -hooked up cameras and aimed. Mounted one monitor up front and hooked up. Need a few more cords and will pick up shelf rod for monitor at first window in londonderry. Will be back Friday or Monday |
| 1929 | Waylon | 07/10/2024 | 04205 | -Co2 sniffer new one added and crimped into lines had to do a stupid amount of connections and looks mediocre at best but the stores getting ripped down so I’m not making the cables look pretty for no point
-Installed ladies room changing table ended up being more of a pain than anticipated since the new table was different than old had to drill 6 new holes through tile I believe atleast 5/6 hit studs so confident in the ability to stay up |
| 1928 | Waylon | 07/10/2024 | 04956 | Ran lines for cameras from wall outside to office had to crimp 12 lines |
| 1927 | Brendan | 07/10/2024 | 10544 | -troubleshooted co2 tank, tank empty and bad level gauge
-replaced backup regulator due to seal leaking
-updated ABS to .100. Working a lot better and not crashing in certain menus now
-noticed that ABS turret door is cracked, new on order |
| 1926 | Jim | 07/10/2024 | 00596 | - snaked and plunged men’s room toilet to no avail, told manager on duty to call east coast |
| 1925 | Waylon | 07/10/2024 | 18198 | -Was told card reader was detached second window and none of the screens were working for lobby menu
Both things were shut off… |
| 1924 | Jim | 07/10/2024 | 02038 | - installed new outdoor exit thank you sign
- wire tied ABS drain line to keep from falling out of drain |
| 1923 | Jim | 07/10/2024 | 07194 | - installed glass and lock on toy display case |
| 1922 | Jim | 07/10/2024 | 07417 | - installed ew welcome sign at entrance |
| 1921 | Brendan | 07/09/2024 | 04956 | -6 cameras on roof, ran line from cameras to inside the service entrance. Will be back to finish running it to office and hooking up the monitors
-cleared roof unit traps |
| 1920 | Waylon | 07/09/2024 | 04956 | -You know I could never touch a camera again and wouldn’t think twice about it tbh
-Installed 6 roof cameras running the line through a conduit was an absolute pain in the butt like dripping sweat 90 outside and it wouldn’t go through the damn line 😤🤬😡😓 |
| 1919 | Jim | 07/09/2024 | 02830 | - removed and replaced sink spray pipe, applied thread tape and no leaks |
| 1918 | Jim | 07/09/2024 | 04205 | - replaced two toilet pipe gaskets on men’s room toilet |
| 1917 | Jim | 07/09/2024 | 18198 | - Replaced ceiling tile above HLZ monitors
- replaced floor tile and grouted in front of HLZ area
- replaced two baseboard tiles by delivery door
- remounted outlet box on road sign post |
| 1916 | Brendan | 07/08/2024 | 10544 | -troubleshooted ABS, piston came unscrewed from the arm. Reattached all set
-repaired handicap push bar
-fixed front counter register. Network cable was smashed with cup caddy |
| 1915 | Brendan | 07/08/2024 | 00596 | -replaced ped13 cord and power supply, also added wire loom and remounted ped to paddle
-was going to put new connector on strawberry line, but I put it down for 5 seconds then it disappeared. Will have to order new one |
| 1914 | Jim | 07/08/2024 | 10622 | - dropped off power washer from Alton
- grouted under and around ABS system |
| 1913 | Waylon | 07/08/2024 | 21582 | -Weldng grease trap the weld kept burning straight through into the lowest heat so took a big to actually fill holes
-Helped the palet loader get the convi oven in the store |
| 1912 | Jim | 07/08/2024 | 17371 | - adjusted hand sinks (2) for more hot water
-replaced ceiling tile in lobby
- sourced and re installed office cabinets locks and bought one new cylinder and three keys |
| 1911 | Waylon | 07/08/2024 | 12272 | - went for dry socket found a broken wire causing it not to work replaced wire then a terminal for a socket snapped of so had to replace socket then a bulb got stuck in a socket so had to slowly unthread that then breaker tripped and now works perfectly lmao
-Measure flag pole circumference for part order |
| 1910 | Brendan | 07/06/2024 | 04956 | -troubleshooted hand sink. Bad solenoid, replaced
-measured for new doors at center island |
| 1909 | Brendan | 07/06/2024 | 02038 | -mcafe machine, no issues just had to instruct how to power on unit |
| 1908 | Brendan | 07/06/2024 | 12272 | -repaired Dr Pepper valve
-troubleshooted register turning off, bad cash drawer cable. Made up a new one.
-ped2 NTF |
| 1907 | Brendan | 07/06/2024 | 21582 | -cleared ABS ice drain
-this ABS giving me a runaround. Ordering parts |
| 1906 | Brendan | 07/05/2024 | 21582 | -fixed platen 2, replaced motor
-repaired stuck delivery door |
| 1905 | Jim | 07/05/2024 | 10544 | - handi cap exit door lock and unlock no issues found
- trimmed and finished sink diamond plate backsplash
- adjusted front hand sink water temp now set at 103 F |
| 1904 | Jim | 07/05/2024 | 25383 | -Replaced delivery door weatherstripping
- applied contact cement on left lobby drink station door
- re fastened diamond plate next to walk in door
|
| 1903 | Brendan | 07/03/2024 | 02038 | -troublehooted ABS not grabbing small cups. Cup sold out sensor misaligned. Adjusted, all set
-delivery monitor not working, unplugged. All set |
| 1902 | Brendan | 07/03/2024 | 10622 | -troubleshooted muffin toaster. Chain bound up and wouldn’t turn. Realigned the gear and tightened chain, this should get them by for now. Bearing going bad causing it to wobble which is probably the root cause. New bearings on order but should be okay until it comes in hopefully |
| 1901 | Jim | 07/02/2024 | 10544 | - cleaned walls, cut and installed diamond plate backsplash attached sink, still need to trim bottom with stock aluminum |
| 1900 | Waylon | 07/02/2024 | 21582 | -Weld grease trap in 7 different spots |
| 1899 | Waylon | 07/01/2024 | 04205 | -Swapped abs cord to a GFCI outlet that was receiving 120 other outlet was very hard to reach and didn’t seem to be receiving more than like 6 volts abs is up and running |
| 1898 | Waylon | 07/01/2024 | 02830 | Don’t even get me started on fixing the monitor mess in Hooksett cause god damn a lot of 🤦🏻♂️🤦🏻♂️🤦🏻♂️ happened but atleast they tried somethings are better left to us though… |
| 1897 | Jim | 07/01/2024 | 04956 | - ran conduit from in stock room to termination box on roof for new security cameras |
| 1896 | Waylon | 07/01/2024 | 02038 | -went for a grill fault took front panel of to measure voltage across terminal block wasn’t receiving any voltage so pulled out and found an outlet unplugged let it heat up and left |
| 1895 | Jim | 07/01/2024 | 04205 | - sourced and replaced spud nut and re installed toilet flush pipes for ladies room large toilet |
| 1894 | Waylon | 07/01/2024 | 21582 | -Grill sink working fine they may have changed the batteries unsure but either ways working
-Installed new co2 alarm by smart clock and ran wires
-Looked at grease trap was said to be bent definitely needs to be welded in 4 different spots will pickup welding equipment from van |
| 1893 | Waylon | 07/01/2024 | 18198 | -Installed new auto transformer to Qing oven and kicked right on like a gem so diagnosis was spot on on the old transformers one of the terminals was stuck open feeding 120 VAC to the board which the board should be giving it 120 |
| 1892 | Brendan | 06/28/2024 | 18198 | -dt carbonator leaking from hose. NuCo over pressurized the tank by 15psi which is probably the cause of the line bursting |
| 1891 | Brendan | 06/28/2024 | 07417 | -replaced Fanta bib pump |
| 1890 | Waylon | 06/28/2024 | 17371 | Bump bar cable |
| 1889 | Waylon | 06/28/2024 | 10622 | -Filet steamer regulator |
| 1888 | Waylon | 06/28/2024 | 00596 | -Deep cleaned Hlz that was like a furball of dust replaced fuse and changed temperature settings |
| 1887 | Brendan | 06/28/2024 | 04205 | FCB working fine… NTF |
| 1886 | Jim | 06/28/2024 | 10544 | - replaced two exit door crash bars and remounted the third
- measured for diamond plate around sink |
| 1885 | Jim | 06/28/2024 | 04205 | - men’s room toilet and sinks cleared by in store maintenance
|
| 1884 | Jim | 06/27/2024 | 07194 | -made and Installed electrical cover in welcome sign
-cleaned and primed welcome sign base
- installed two ceiling tiles
- all high chairs have no wheels |
| 1883 | Waylon | 06/27/2024 | 12272 | -Grill pm skipped pneumatic lines gonna start replacing those as needed |
| 1882 | Brendan | 06/27/2024 | 12272 | Left grill PM |
| 1881 | Jim | 06/27/2024 | 02830 | - repaired sink plumbing, drilled out broken pipe stub and cleaned faucet threads to accommodate new pipe.
|
| 1880 | Jim | 06/27/2024 | 02038 | - remounted delivery door crash bar
- remounted table top in lobby |
| 1879 | Brendan | 06/26/2024 | 10622 | -diagnosed bun steamer not steaming a lot. Steamer showing 10psi, receiving 40. Bad regulator, on order
-spring missing from window handle, ordering a new one |
| 1878 | Waylon | 06/26/2024 | 04205 | Installed one co2 sensor had to crimp into unit in stock room
Looked a freezer door hinge Brendan having them call Rick |
| 1877 | Brendan | 06/26/2024 | 07194 | -looked at ABS leak. Fortunately there is no leak, just condensation from the cold water lines since it is warm out this can be expected. Nothing wrong though |
| 1873 | Brendan | 06/25/2024 | 21582 | -replaced valve block at ABS. Was such a long process, had to turn off all water and drain all syrups.
-repaired stockroom leaking from water line
-replaced ABS displays but one came defective
-replaced booster pressure switch
-installed lot security cameras with Waylon (who dropped a drill off the roof onto a car lmao)
-replaced delivery monitor |
| 1876 | Waylon | 06/26/2024 | 02830 | -Replaced cabinet strip fading |
| 1875 | Waylon | 06/26/2024 | 18198 | First time running into this hopefully it’s correct qing oven is not working was the ticket - first thing I noticed was blower motor not running when open so checked fuses all good then started at HV board which seemed to be fine was receiving 208 was weird that the transformers were not pulling any amperage when running or test mode but the auto transformer in the top has an open leg which shouldn’t be the case so my diagnosis is that but will probably order a HV board too since those seem to be the only options
Tested the magnetron was good and did amperage checks on transformers also wouldn’t make sense for 3 transformer to magically go bad at the same time |
| 1874 | Brendan | 06/25/2024 | 00596 | -looked at lobby leak again. Will have to bite the bullet and order a new ice bin. |
| 1872 | Waylon | 06/25/2024 | 21582 | -Cameras installed for roof |
| 1871 | Jim | 06/25/2024 | 25383 | - re set and mortared drive they curbing
- grout above large stall in ladies room
- repaired lobby bench |
| 1870 | Jim | 06/25/2024 | 02830 | - replaced door closer on delivery door
- installed three floor tiles and grouted |
| 1869 | Brendan | 06/24/2024 | 12272 | -replaced blown coffee brewer line segment
-disabled coffee brewer warmer plates
-noticed that blue raspberry and coke FCB looked nastyyyy. Someone hooked up the blue razz line to the coke BIB, hooked up the coke line to the blue razz BIB, AND swapped the label cards on the front lol. Had to purge lines and tanks and refilled. Probably used a lot of co2 lol |
| 1868 | Brendan | 06/24/2024 | 25383 | -window 1 working perfectly fine as expected. NTF
-replaced walk-in emergency handle
-cash drawer cable, cable perfectly fine, but was plugged into wrong port
-troubleshooted front counter scanners. Pos2 scanner switch was in wrong position, all set. Pos1 is missing a ribbon cable. Will bring new scanner next visit.
-affixed ped/scanner brackets to table. Ped1 needs a new adapter plate, on order
-kiosk 6 door stuck closed. Got it unstuck and adjusted latch cable
-lane 2 speaker not working at all, crusty wire. All set |
| 1867 | Waylon | 06/24/2024 | 04956 | Wall tiles
Fry socket
|
| 1866 | Brendan | 06/24/2024 | 02830 | -monitors in grill all working NTF
-camera monitor wasn’t working due to incorrect resolution. All set
-replaced ABS cup alignment spring, cup finger. Ordered medium cup tube.
-Replaced frappe bottom base, blew out condensation drain |
| 1865 | Waylon | 06/24/2024 | 10544 | -Men’s room pipe cover
-Qing oven cord
-Wall tile
-Door stopper lobby
-Weather stripping for door??? I don’t see any please add photo
-Grill button
|
| 1864 | Jim | 06/24/2024 | 00596 | - re installed board on corral
- installed deadbolt on pass thru door by registers and locked it |
| 1863 | Jim | 06/24/2024 | 12272 | - sourced and replaced men’s room flush valve and all seals
- grouted small stall door frame in ladies room |
| 1862 | Jim | 06/24/2024 | 07417 | - replaced sink strainer and all drain pipe's with chrome plated brass pipes |
| 1856 | Jim | 06/21/2024 | 04205 | - shimmed coke tank
- modified expansion plug and installed on floor drain |
| 1861 | Brendan | 06/23/2024 | 12272 | -emergency call flooding store shut off main. Just had to turn off water to one toilet
-after I turned water back on, the line to coffee brewer catastrophically exploded, flooding the present window, electric outlets, and killed the camera monitor… I don’t have any of my water supplies on me so I turned water off to that one brewer, will come back tomorrow to repair line |
| 1860 | Brendan | 06/21/2024 | 00596 | -troubleshooted hlz. Blew a fuse. Probably because it’s so dusty. Don’t have any on me, Waylon does
-troubleshooted oven. I am concluding people are just pressing the wrong button or something because the oven is temping perfectly fine and none of the managers there say they have had issues. NTF
-troubleshooted washing machine customer states not draining properly. Have looked at it a few times and every time the linens are clean and dry. NTF |
| 1859 | Brendan | 06/21/2024 | 21582 | -replace lift solenoid for ABS. So that works now. However after replacing orings and flow controls and flow control housings the soda water still leaks. The valve block must have a hairline crack. On order. Never done one before hopefully it won’t be a nightmare. |
| 1858 | Brendan | 06/21/2024 | 04956 | -rebooted kvs2
-removed stuck fry bulb socket-socket is really burnt, not a good time to replace it. Will do next week |
| 1857 | Brendan | 06/21/2024 | 07417 | -replaced ped15 cord |
| 1855 | Waylon | 06/20/2024 | 10622 | -cleaned filet steamer screen causing it to not let half the water through and not steam
-Fixed door locking mechanism lobby door
-Fixed window latching for window 1 (Rivet tools suck tbh)
-Jostled the vent cover in grill did not fall all prongs look good
-disabled coffee brewer heat plates per nrbes requirement
-Fixed men’s faucet loose
-Fixed drive thru signs leaning dug up dirt behind and filled back
-replaced two wheels on trash buggy
-Wing oven door handles were said to be loose the actual handle is not coming off and it’s not worth replacing unless actually broken a lot of handles are like that they just aren’t used to it |
| 1854 | Jim | 06/20/2024 | 12272 | - removed and cleaned fryer frame & re set
- installed sink pipe cover on ladies room drain
- replaced weatherstripping on delivery door
-grouted by bulk ice and drive thru ice bin floor
-tightened packing nut on shut off for sink soap dispensers
- tried to move ceiling vent but there are too my any lines and wires in the way there is no room to do it |
| 1853 | Brendan | 06/20/2024 | 18198 | -repaired two coke syrup leaks. What a pain.
-found ABS front panel. Should have not ended up on my list, was not hard to find. |
| 1852 | Waylon | 06/20/2024 | 18198 | -OJ machine not fully dispensing syrup was a bad nozzle |
| 1851 | Jim | 06/20/2024 | 02038 | - replaced one baseboard tile by delivery door
- secured lobby stool foot rest
- replaced sprinkler head by # 5 spot
- installed mop hanger up front area
- installed new egg crate vent cover |
| 1850 | Brendan | 06/19/2024 | 04956 | -ABS down again… looks like index sensor was knocked loose. All set |
| 1849 | Waylon | 06/19/2024 | 02038 | -Replaced 2 UHC cords involved swapping both OEPs too
-fixed ice bin leak
-Investigated another leak told them to call Rick since it was coming from the condensation part of the refrigeration |
| 1848 | Brendan | 06/19/2024 | 00596 | -managed to get new gasket thing in for lobby agitator motor. What a nightmare |
| 1847 | Brendan | 06/19/2024 | 21582 | -diagnosed ABS. Bad solenoid, on order. Also noticed soda water leak from bad flow control o ring. On order
-diagnosed McFlurry mixer. Tachometer bad, on order |
| 1782 | Jim | 06/04/2024 | 02830 | - installed new hand sanitizer by exit door
- removed and replaced floor tile by dryer
1 checked rear door closet and found it was ripped off the frame mount. Will need to have holes welded so we can redrill and tap and the closer pivot arm is bent beyond repair.
|
| 1846 | Jim | 06/19/2024 | 02038 | - Re mounted hand soap dispenser in men’s room
- filled & brushed sidewalk crack
- replaced 18 floor tiles behind front counter and grouted
- replaced 4 floor tiles at walk in and grouted
- caulked slop sink |
| 1845 | Brendan | 06/18/2024 | 02038 | -replaced relay for pie warmer
-replaced “extension cord🙄” with adapter
-replaced broken shutoff for hose bib
-troubleshooted water in present window. One issue was that ice bin pipe was misaligned, other issue is the fridge is leaking-Rick problem
-troubleshooted co2 leak. Found very minor leak in frappe regulator. Rebuilt, hopefully will solve |
| 1844 | Brendan | 06/18/2024 | 04205 | -coffee brewer leaking everywhere; cracked line going to brew valve. Replaced that for right coffee brewer. Left coffee brewer giving low tank fault. Found kinked waterline, replaced water line with kinkless tubing
-shake machine only dispensing syrup; pump motor overload tripped. Reset and now working fine.
-rebooted zoom timer |
| 1843 | Brendan | 06/17/2024 | 04956 | -ABS working fine after I put conveyor on🤷🏻♂️
-Coke just didn’t have co2 connected
-installed new drawer slides for grill fridge |
| 1842 | Brendan | 06/17/2024 | 04205 | -cut back muffin toaster cord
-troubleshooted walk-in lights. What a pain. Coincidentally had nothing to do with the light falling. Eventually traced it back to a jbox behind fridge curtains. Wire snapped off inside wire nut. That wire was going to the light switch but not enough slack left to reconnect. Bypassed switch so now it’s all set
-disabled coffee warmers
-readjusted dt fridge
-cut off old power cord for window 2 |
| 1841 | Waylon | 06/17/2024 | 10622 | Egg cooker switch |
| 1840 | Waylon | 06/17/2024 | 02038 | -Fixed display board side 2 replaced with new cause clearly to dim replaced the strip on that board to
-Display board aide 1 replaced and replaced strip with it
-Looked into mcflurry mix working intermittently worked fine for me tested button 20 times reads correctly on the button and made 4 McFlurrys to double test |
| 1839 | Waylon | 06/17/2024 | 18198 | -high priority ticket for no water in womans room faucet (Told batteries were changed) starting to take everything apart checking Vdc on power to valve was only receiving approximately .5 this setup needs 6Vdc to actually run took out batteries measured was receiving about .5 per battery so no wonder only an led light was working
Replaced batteries fixed…. |
| 1838 | Jim | 06/14/2024 | 04205 | - sourced and installed new ceiling light in freezer
|
| 1837 | Brendan | 06/14/2024 | 02038 | -repaired eproduction wiring that was ruined from water. Replaced outlet with twist lock so it wouldn’t keep falling out, as well as wired directly into box so it is not a double male cord.
-installed dt paddle first window
-corrected receipt printers side 2
-pie merchandiser-misdiagnosed. Actual problem is relay stuck closed causing hi limit to trip. Part on order |
| 1836 | Jim | 06/14/2024 | 02038 | - filled holes in FRP by rear delivery door
- replaced two bulbs in freezer
- installed walk-in curtain
- removed curtains between walk-in and freezer
- shimmed bulk coke tank |
| 1835 | Waylon | 06/13/2024 | 02038 | -kinda salty like the day before an nrbes a grill button is gone and 2 belts inside a platen snap of like whattttttattataata are we serious
-Anyways installed 2 new belts for the grills platen 2 (Pain in the ass)
-Installed new button for platen 4
-Fixed pneumatic lines again clearly the air flow restrictor is being so sensitive like bro chill out so I drilled the hole a little bigger to be honest bigger than I wanted cause now the grill closes a little faster but it works and it’s already 8:30 on a Thursday and I’m over it like on hour 12 frick this
-Installed new switch for pie merrchandiser for some reason we got a 4 prong switch instead of a 3 anyways hooked it up turned on receiving 120 VAC to all legs but no power which makes absolutely no sense anyways Brendan’s gonna take a look when he comes back in the morning probably just something goofy I missed
-Bulb for freezer serial number is F54W-T3-941 sent to Brendan so Jim can grab a bulb in the AM if they’re even sold in stores
-Uhmmmm what else oh all my tools and me got covered in grease woohoooo happy Thursday 🥳🥳 |
| 1834 | Brendan | 06/13/2024 | 02038 | -eproduction troubleshooting. Was tough to figure out, but found one bad wire and one bad outlet. The outlet was dripping with water from leaking auto mist. Don’t have time to fix today so will be back in the morning |
| 1833 | Brendan | 06/13/2024 | 00596 | -Ran line/installed 5 lot cameras |
| 1832 | Waylon | 06/13/2024 | 00596 | -Installed 5 new cameras with Brendan and ran wires to office was grueling and hot |
| 1831 | Jim | 06/13/2024 | 10544 | - replaced and grouted 9 floor and two baseboard tiles
- grouted by dish sink,ice bin area, and from the rear door to the electrical panels
- installed temporary covers on flagpole |
| 1830 | Waylon | 06/13/2024 | 18198 | -Cleaned up soda syrup on light in ceiling dripping down |
| 1829 | Jim | 06/13/2024 | 04205 | - lifted ceiling above prep area in kitchen
- adjusted side trash door so it closes on it own
- sent photo to Debbie of main water shut off for labeling |
| 1828 | Jim | 06/12/2024 | 17371 | - replaced fence post
- replaced two wall tiles in men’s room stall
- cleared men’s room urinal
- replaced floor tile in crew room |
| 1827 | Brendan | 06/12/2024 | 04956 | -was going to attempt to run new camera wire to the roof myself but did not go as planned. Will need Jim’s help to drill through concrete wall
-ran line/installed camera in support area
-replaced pie warmer switch |
| 1826 | Brendan | 06/12/2024 | 10544 | -ran/installed new camera for merge monitor
-replaced music media player, ran new line
-replaced 1st window latch plate |
| 1825 | Waylon | 06/12/2024 | 10544 | -Ran Ethernet lines for camera to office from multiplex
-Ran Ethernet line for music from crew to office
-Ran Ethernet line from walk in door to ice machine for co2
-Installed new co2 alarm
-Installed new door hinge with help from YouTube video
- Broke up 2 tiles by back door but do not have correct tiles Jim will come tmrw for
- investigated fc camera not working came out to be a slightly very small slightly unplugged wire
-Bun toaster motor temp fail code ended up being a faulty fan and the screws were put in with Mo tire so my drill barely got them out 😭
-Men room faucet was free swinging went under tighten and straightened bracket
|
| 1824 | Jim | 06/12/2024 | 02038 | - rotated two tables in play place and measured to order new ones
- grouted by grill ketchup dispenser
- power washed drive thru overhangs
|
| 1823 | Jim | 06/11/2024 | 21582 | -replaced three lobby ceiling tiles
- installed delivery door sweep
- installed toy display glass
|
| 1822 | Brendan | 06/11/2024 | 07417 | -replaced oven controller, all working. |
| 1821 | Waylon | 06/11/2024 | 25383 | Installed meat freezer door
-Installed new switches for blinds and had to mess with the electrical
-Installed new co2 alarm
-Installed 2 sanitizer dispensers near lobby doors within 6 ft |
| 1820 | Brendan | 06/11/2024 | 00596 | -went to simply replace lobby motor and gasket. NOT so simple… whoever’s idea it would to use a wingnut under an ice bin is an idiot. Much finagling later I finally got the motor out and replaced. However I am unable to replace the gasket because the massive ice machine is in the way. Rick will need to come out to deinstall before I can finish it up |
| 1819 | Jim | 06/11/2024 | 21582 | -replaced three lobby ceiling tiles
- installed delivery door sweep
- installed toy display glass
|
| 1814 | Brendan | 06/10/2024 | 07194 | -made up new cash drawer cord for pos13
-replaced hi-c bib pump
-calibrated orb screen
-mccafe milk not dispensing. No trouble found
-replaced cabinet switch |
| 1818 | Brendan | 06/11/2024 | 12272 | -fixed orb
-replaced vzn filter pressure relief
-replaced vzn permeate tank
-replaced freezer door closer
-adjusted fridge door closer
-replaced paper towel dispenser |
| 1817 | Jim | 06/11/2024 | 00596 | - tightened ladies room faucet
- checked men’s room stall door, needs new door
- re fastened door frame on pass thru door from lobby to registers
- ran snake got to about ten feet and hit blockage could not break thru
- replaced five floor tiles and grouted
|
| 1816 | Waylon | 06/11/2024 | 02038 | -Installed new light bulb for fridge the fittings are a little suspicious looking but work
-Diagnosed pie warmer needs a new switch
-Reprogrammed all cabinets different slots
-Welded chicken vat oil pan 4 different corners |
| 1815 | Brendan | 06/11/2024 | 02038 | -replaced ped15 and paddle. Still waiting on 13 paddle
-plugged in orb and calibrated touch screen
-reaffixed kiosk light pole fascia plates to ceiling
-looked into water leaking from ceiling, auto mist line has a crack in it-it’s an RTI issue |
| 1813 | Brendan | 06/10/2024 | 00596 | -called for flat soda. No issues found. Definitely not flat.
-found and repaired co2 leak, frappe had cracked shutoff |
| 1812 | Waylon | 06/10/2024 | 21582 | —installed cover for electrical box above abs
-Replaced cabinet strip
-installed new oep outlet since old cover and plastic broken
|
| 1811 | Brendan | 06/10/2024 | 07417 | -troubleshoot oven. New controller on order |
| 1810 | Jim | 06/10/2024 | 07194 | - checked drain pipes at back sink for leaks
. Ran washer three times and filled two sinks with water and found no pipe leaks at lake but if the drains are opened fully the open cup will overflow.
Told Linda and she said she would watch out for the proper way to drain sinks |
| 1809 | Jim | 06/10/2024 | 07194 | - checked sink drain pipes and found no leaks
They still need to drain sinks slowly as the open cup drain will still overflow if opened all the way |
| 1808 | Waylon | 06/10/2024 | 02038 | -Replaced 5 different strips in 3 different cabinets on 2 different sides….
-Grabbed light bulb to buy one at store for 4 door fridge |
| 1807 | Jim | 06/10/2024 | 10544 | - glued and re attached pvc pipe for roof drain |
| 1806 | Jim | 06/10/2024 | 07417 | - installed new drive thru pickup #2 sign and mount on building
- replaced door sweep on delivery door |
| 1805 | Waylon | 06/10/2024 | 18198 | -Installed left cabinet bottom strip and tested
-Installed new light lens in grill
-Fixed loose sink in men’s bathroom |
| 1804 | Brendan | 06/08/2024 | 18198 | -installed ADA trackpad blanks
-installed replacement cover and decal Hi-c valve
-repaired Fanta valve
-attempted to repair coke line leak, but the line is too deteriorated. Will have to run new line in the ceiling. Job for another day when it’s not 3am on a Friday |
| 1803 | Brendan | 06/07/2024 | 04956 | -repaired ABS, major work. Replaced drain pan, motor, and sensors. New style sensor does not play well. Had to rig it up the best I could
-installed ADA trackpad blanks
-orb not working, controller died. Had to replace
-diagnosed pie merchandiser, indeed bad switch. On order |
| 1802 | Brendan | 06/07/2024 | 10544 | -installed two ADA trackpads
-installed new bump bar |
| 1801 | Brendan | 06/07/2024 | 07194 | -troubleshooted oj machine water leak. It looks like the water bath overflowed. But I can’t reproduce it so hoping it’s a fluke
-ordered lid for 10:1 freezer |
| 1800 | Brendan | 06/07/2024 | 00596 | -troubleshooted leak under SSBS. Motor gasket is shot. New parts on order
-repaired shake machine flavor line issues. Some lube and quick leak fix took care of the issue |
| 1799 | Brendan | 06/07/2024 | 21582 | -ABS error, index sensor very misaligned. Adjusted all set |
| 1798 | Waylon | 06/07/2024 | 10544 | Grout under abs and plumbed abs tray not the happiest with how it got plumbed since Home Depot had a lack of fittings but works |
| 1797 | Jim | 06/07/2024 | 12272 | - grouted men’s room walls
- tightened men’s room toilet and seat
- mounted three hand sanitizers by exits
- re set chain on present window
- replaced two dish soap dispensers |
| 1796 | Jim | 06/07/2024 | 02038 | -R&R 4 lobby tables
- repaired crew room ceiling |
| 1795 | Jim | 06/06/2024 | 00596 | - checked lobby drink station drain, poured bucket of hot water in to sump and cleared out drains fine now |
| 1794 | Jim | 06/06/2024 | 02038 | - grouted multiple floor areas around store
- cut and installed two black egg crate covers
- added diamond plate behind dishwasher |
| 1793 | Waylon | 06/06/2024 | 21582 | -fixed Jim’s dangerous plug that was supposed to be an outlet |
| 1686 | Waylon | 05/09/2024 | 02830 | Welded 2 door prep fridge
Welded fry hopper bracket
Welded frustration fry holder bracket that one needed like 15 different spots welded and it’s not a perfect fit but I’m hoping overtime they’ll wear the metal so it fits better |
| 1792 | Waylon | 06/06/2024 | 10622 | -Jacked up frappe machine to take off wheels and add washers to tilt it but when I went under with my impact the bolts weren’t budging in the slightest so I assume whoever either replaced or originally installed these wheels had a much more power impact so couldn’t do that
-Welded back door handle the weld is under the top part of the handle I thought my angle grinder would fit to grind down the welds but didn’t so will have to come back in the future to file it down but it’s not noticeable and works like a gem 💎 |
| 1791 | Jim | 06/06/2024 | 02830 | - replaced lite lens in office
- grouted in front of ABS and Multiplex |
| 1790 | Brendan | 06/05/2024 | 07417 | -installed orb controller
-installed ADA trackpad blanks
-lane camera was working fine no trouble found |
| 1789 | Brendan | 06/05/2024 | 04205 | -troubleshooted both detex and repaired
-fixed danger zone monitors not working
-installed bump bars
-repaired so many lobby valves
-installed 2 grill printers |
| 1788 | Brendan | 06/05/2024 | 25383 | -installed ADA trackpad
-troubleshooted lobby curtains. Switch is bad, both are actually bad but not bad enough to cause issues. Two on order
-looked at 10:1 freezer door. It’s destroyed, needs replacement . On order |
| 1787 | Waylon | 06/05/2024 | 10622 | -Cleared 2 leaks from frappe machine still need to go back and raise the two front caster wheels up
-Installed new window sensor
-Looked at back door handle that Jim didn’t finish screwing in covered by two plates so gonna weld it tmrw when there’s no rain |
| 1786 | Brendan | 06/05/2024 | 12272 | -ABS. Working perfectly fine no trouble found
-installed ADA trackpad
-orb, missing power cord, will find one and bring next time |
| 1785 | Brendan | 06/05/2024 | 02038 | -repaired board for UHC and replaced. What a doozy
-installed ADA trackpad |
| 1784 | Waylon | 06/05/2024 | 17371 | -Regrouted mop sink all the way over to dish sink wall
-grouted back door 6x6 area under trash buggy
-Grouted tiles that Jim left without grout by back door
-Grouted area to the left side of fry hopper
-Replaced 4 caster wheels on 10:1 freezer one wheel Jim installed earlier in year was just the wrong wheel and one was melted to be flat
-Fixed door not auto closing on 10:1 freezer originally thought the wheels would solve the problem but added 3 washers to each screw on back two legs so the auto close will work tested about 25 times and sent Brendan a video |
| 1783 | Jim | 06/05/2024 | 02038 | - replaced two lobby light bulbs
- repaired emergency light by office
- replaced broken emergency light aimed at delivery door
- tightened men’s room faucet
- replaced five lite lenses
- replaced two light ballasts
- installed weather stripping on delivery door |
| 1781 | Waylon | 06/04/2024 | 02038 | Fixed outlet for tables heating up |
| 1780 | Brendan | 06/04/2024 | 10622 | -fixed merge monitor
-installed ADA trackpad
-fixed fry hopper, bolts loose that kept the sensor on
-fixed shake machine, beater overload tripped
-fixed orb
-fixed spare printer
-cleaned out packages in stock room |
| 1779 | Waylon | 06/04/2024 | 04205 | -Replaced heater blanket side 2 this one was more a pain cause there’s extra electrical in the box
-Then found Jim’s previously fixed sink to be pouring water through the wall wet vacced it out I smell like sewer now and the water is seeping in from the floor so called east coast
1Took out the whole meat fridge drawers and brackets and deep cleaned and wiped everything down now it closes on its own was just a bunch of gunk on tracks
-Looked at dt fridge seems to need new hinges Brendan said some are in office |
| 1778 | Jim | 06/04/2024 | 10622 | - installed two push bars on delivery doors
- glued and clamped picnic bench in lobby |
| 1777 | Jim | 06/04/2024 | 00596 | - checked ladies room toilet , found none leaking
- installed hand sanitizer next to exit door |
| 1776 | Brendan | 06/04/2024 | 17371 | -installed ADA trackpad
-adjusted women’s room water temp
-fixed shake machine, pump stem was out |
| 1775 | Brendan | 06/03/2024 | 21582 | -installed ADA trackpad
-installed scanner present window |
| 1774 | Brendan | 06/03/2024 | 00596 | -cleared clog in frappe drain, stupid Oreo frappe
-installed kiosk door blank
-troubleshooted orb, usb unplugged, all set
-installed 2nd grill bump bar |
| 1773 | Brendan | 06/03/2024 | 07194 | -installed ADA trackpad
-verified fryer motor was working |
| 1772 | Waylon | 06/03/2024 | 21582 | -Installed side 2 bump bar
-Second window light ballast
-Oep cord for cabinet
-Emergency light
- replace camera by bathroom |
| 1771 | Brendan | 06/03/2024 | 02830 | -troubleshooted frappe leaks. Blew out condensate line and loose crimp on mocha mix fixed
-troubleshooted orb, unplugged. Reconnected and calibrated
-replaced thumb lock window 1
-installed ADA trackpad |
| 1770 | Jim | 06/03/2024 | 21582 | - installed push bar on rear door |
| 1769 | Waylon | 06/03/2024 | 02038 | -Removed old plug that goes to table heaters Brendan messed up delivery dates so the part wasn’t in so I got it all ready for the new outlet to just be thrown in voltage stick gave me a false reading so thankfully I checked with my meter
-Took exit sign for Hanover st |
| 1768 | Jim | 06/03/2024 | 07194 | - installed rear door crash bar |
| 1767 | Jim | 06/03/2024 | 00596 | - repaired board on corral |
| 1766 | Brendan | 06/01/2024 | 21582 | -troubleshooted emergency lights, not even charging, needs new unit
-fixed ORB, just unplugged |
| 1765 | Brendan | 06/01/2024 | 00596 | -stole kiosk door
-replaced o ring frappe water |
| 1764 | Brendan | 06/01/2024 | 10544 | -attempted to clear drain under ABS, was unsuccessful. Will call east coast on Monday
-repaired blue raspberry FCB, rebuilt dispense valve and replaced pressure relief |
| 1763 | Brendan | 05/31/2024 | 02038 | -troubleshooted no power to tables and fridges. Bad outlet, on order
-replaced dt window chain
-removed autogreeter
-replaced ped15 cord. Need to order another paddle |
| 1762 | Brendan | 05/31/2024 | 04956 | -ABS. tried tapping new holes for motor, but then screw were too big for motor. So then tried to drill holes bigger to put a rivet nut in, but then the metal deteriorated. So will need a new drip pan, on order
-adjusted temp on muffin toaster |
| 1761 | Waylon | 05/31/2024 | 02038 | -Installed new check valve for grill
-Installed new pressure switch for grill
-Continued diagnosis on why platens weren’t fully going down now
-Found air leak in the fitting that came of the check valve to pneumatic lines
-Replaced fitting
-Still not fully going down, found a bad inline restrictor and replaced the whole line now fully working
-So 3 different problems occurred first massive co2 leak then a small co2 leak than co2 not getting through half the lines |
| 1760 | Jim | 05/31/2024 | 04205 | - opened wall by hand sink next to prep table for leak
Found no active leak. It installed 14 inch access panel if needed in the future
- found open abandoned inch and a half drain pipe, installed cap |
| 1759 | Jim | 05/31/2024 | 21582 | - replaced rear door lock with push bar system
|
| 1758 | Waylon | 05/30/2024 | 18198 | Bathrooms backed up, tried to go down the two plumbing holes but neither of the caps would come up at all so snaked down the toilet scraped a little bit but nevertheless fixed |
| 1757 | Waylon | 05/30/2024 | 21582 | -Salty very salty, this wasn’t Jim’s fault just coincidence. Walked in they said the filet steamer was broken and Jim just replaced the top OEP and the filet steamer was receiving power he told me he didn’t know what breakers to check but the line was literally getting voltage so not sure why we skipped to breakers anyways filet steamer was receiving power so moved it from its spot and opened it up. Both wires goikg into the switch has no cover on them meaning they were being grounded out instantly how it didn’t blow the switch and possibly the board I have no idea but replaced the whole cord which takes forever on filet and swapped the oep to the new cord working and tested OH don’t let me forget the water line on the first quick disconnect is missing it’s fitting SO WATER STARTED POURING EVERYWHERE 😭😭😭😭 |
| 1756 | Jim | 05/30/2024 | 21582 | -replaced OEP
-mounted three new hands free paper towel dispensers
- cleared sink drain
- repaired door sweep issues |
| 1755 | Waylon | 05/30/2024 | 07417 | -Installed co2 central unit and signs
-Removed one old co2 alarm and leaving the office one since it covers a whole in the wall…
-Installed new side 2 heater blanket had to pull out old one and than gently reinstall since the wires are so tiny and easily damaged |
| 1754 | Jim | 05/30/2024 | 12272 | - sourced and replaced washing machine
- installed washer on prep sink drain pipe
- helped replace light bulb in lobby |
| 1753 | Brendan | 05/29/2024 | 12272 | -troubleshooted fax, wires fell out of crimp. All set
-dr window, centric nut fell off causing chain to come off. Installed new nut and aligned doors
-troubleshooted merge monitors, plug just fell out |
| 1750 | Brendan | 05/29/2024 | 10544 | -troubleshooted FCB, looks like it needs a new pressure relief and dispense valve rebuild. On order
-troubleshooted co2 leak, ice was actually almost completely melted off, must’ve been an empty bin or something. Still looked though, couldn’t find anything. Did notice economized circuit was off so turned it back on
-tried to figure out merge monitor camera. Cameras are such a mess, but determined it needs a new camera. I have extras in south willow I will use next time. Also realized it is network capable, so added it to guarding vision
-crimped new connector on hotg bump bar |
| 1752 | Jim | 05/29/2024 | 02038 | - installed rear door push bar |
| 1751 | Waylon | 05/29/2024 | 07417 | Installed 2 more alarms and ran wires
-Hung 4 co2 signs
Only have central unit left and rip out old unit |
| 1749 | Jim | 05/29/2024 | 04205 | - installed two faucet cartridges for men’s room sink |
| 1748 | Brendan | 05/29/2024 | 02038 | -Left grill PM. Had bad pressure switch so went to replace, but then the check valve snapped off inside the cross so need to order them….
-ordered light for emergency light |
| 1747 | Waylon | 05/29/2024 | 02038 | -Grill Pm got around half way down till there was an air leak and the check valve snapped off so parts are ordered |
| 1746 | Jim | 05/29/2024 | 02830 | - grouted floor by sink and coke tanks
- grouted men’s and ladies room walls as needed
- grouted by ice bin at Drive thru
- installed three hands free paper towel dispenser |
| 1745 | Brendan | 05/28/2024 | 04956 | -this abs….. will be back |
| 1744 | Waylon | 05/28/2024 | 07417 | -Installed sniffer alarm
-Installed 2 co 2 alarms and ran wires around back sink area
|
| 1743 | Brendan | 05/28/2024 | 07194 | -repaired all 3 lobby valves. All are now working
-revered moffat door and finished setting up. All working great!
-setup eproduction for simplified breakfast
-troubleshooted handicap buttons not working, lost pairing. Repaired all set |
| 1742 | Waylon | 05/28/2024 | 00596 | -Fixed filet steamer with no power one leg got grounded to a piece of metal electrical taped both legs off I don’t see enough risk to replace the whole cord
-DT window 1 swapped automatic top plate to a manual one this also meant removing all electrical components and the motor plus some metal cutting
-Installed side panel for abs ice machine |
| 1741 | Jim | 05/24/2024 | 10622 | - tightened coke tank
- painted stock room walls
- checked table in lobby for cracks, need to talk to Venus as the crack is superficial.
|
| 1740 | Waylon | 05/24/2024 | 07194 | -Installed a new 4 prong twist lock on cabinet cord
-Filet steamer not receiving water was shut up at ro
-water release from filter at mop sink pipe was falling off wall remounted
-tan simplified breakfast cable across kitchen ceiling |
| 1739 | Waylon | 05/24/2024 | 12272 | -Welded freezer door holes closed then retapped and installed hing back on working smoothly |
| 1738 | Jim | 05/24/2024 | 04956 | - installed new pay her and pickup here signs at the drive thru |
| 1737 | Brendan | 05/23/2024 | 07194 | WOW-going to replace booster pump, but also found faulty check valves to be the fault. So will need to be back to finish up once I get some check valves.
THEN I thought I was going to have to run new line for hi-c BUT I tried it and it was working so then I was confused and irritated. Then I realized the Fanta wasn’t working in lobby. Go back to multiplex to check things and find the hi-c valve is off like I left it and the Fanta is on. But then it clicked; during the hi-c flavor change, Ken’s SWAPPED THE HI-C AND FANTA LINES GOING TO LOBBY!!!! I tested this hypothesis and lo and behold this was the case. For years lobby customers have been getting carbonated hi-c and entirely flat Fanta. So what was probably happening is that when they were running out of Fanta but it looked like the hi-c was broken too. I fixed this issue and think this will be the last I hear of it. There are still 3 broken lobby valves (which I didn’t know until I walked in) and I left my lobby valve kit at another store so I’ll get it next visit. |
| 1736 | Waylon | 05/23/2024 | 12272 | -Retapped ice machine cover
-Lobby ice machine cover was on fine so I assume someone got to it
-Fixed dish sink water not turning off
-Looked into hinge on freezer door in grill I’m coming back to weld it tmrw since they need that freezer for all fried products |
| 1735 | Waylon | 05/23/2024 | 10622 | -Screwed down hand wash sink
-Replaced printer head in label maker
-Looked into oven was not making any noises that were out of normal found why it’s not heating so fast it’s a 40 amp over on a 30 amp breaker so someone wired one heating element to a neutral so it wouldn’t heat one element leaving as is because it will blow the breaker and it does the job atm
-diagnosed window closer needs a new sensor
-side 2 UHV wasn’t displaying any error code
-frappe leak is just wear and tear on equipment and ice melting down no big deal at all |
| 1734 | Jim | 05/23/2024 | 02038 | - sourced and installed lite bulb for drive thru fridge
- replaced multiple ceiling tiles in kitchen, stock room, and lobby
Remounted sanitizer for dish sink |
| 1720 | Jim | 05/21/2024 | 00596 | - replaced two light lenses
- picked up cabinet door to drop off for repair
|
| 1733 | Waylon | 05/23/2024 | 25383 | -Fixed RO leak spraying water through the whole store
-Fixed co2 leak that caused the whole tank to ice up
-Started looking into lobby shades but two woman are sitting under the one I suspect has the motor in it… |
| 1732 | Jim | 05/23/2024 | 02830 | - installed broom holders at front area and near crew room
- installed three lite bulbs in lobby light
- replaced bun belts on toaster |
| 1731 | Jim | 05/22/2024 | 07417 | - removed broken exterior ext sign and replaced with new sign
- installed new pay here and pick up here# 1 signs at drive thru
- removed damaged exterior enter sign and taped off wires |
| 1730 | Waylon | 05/22/2024 | 02038 | -Installed 2 new bump bars
-diagnosed beverage fridge
-window auto close chain broke
-took board from UHC for Brendan
A fry hopper was auto dispensing… |
| 1729 | Waylon | 05/22/2024 | 04956 | -Installed new Hlz motor and scraped a ton of it clean on the inside to fit the motor properly
-Installed 2 new boards for cabinet and swapped one display and installed one strip cabinet is all set now
Than a crew came out and told me fish vat wasn’t temping and checked plugs it was a plug problem was the fish vat barely rolls lmao so took a min to get too |
| 1728 | Brendan | 05/22/2024 | 07194 | -installed multiplex parts: new compressor relay, agitator switch, required agitator correctly, new wire for compressor. Should be all set, store just needs to wait 6-12hrs for it to cool down so they can use lobby soda |
| 1727 | Jim | 05/22/2024 | 10544 | - related enter sign on west side entrance |
| 1726 | Brendan | 05/21/2024 | 04956 | -troubleshooted ice maker on ABS. Was working perfectly fine. Watched for a few cycles. ABS was down due to broken sensor. New sensor on order along with conveyor motor since I will probably need to destroy the old one to get it out. Drain line was also kinked, also on order.
-troubleshooted water by SSBS. Primary issue was someone did not correctly put cover back on ice machine. Second issue was that ice gate was getting stuck open due to the ice chute being too tight. Adjusted all set
-looked at 4:1 fridge, needs new slides, on order |
| 1725 | Brendan | 05/21/2024 | 02830 | -replaced 8 enter/exit sign inserts
-replaced two freezer light bulbs
-troubleshooted outlet for chill rail, just tripped. Running fine.
-troubleshooting seated apparently going off randomly. Bypassed door switch so it should tell me if it is the door sensor/wire or board |
| 1724 | Jim | 05/21/2024 | 25383 | - installed diamond plate backsplash at sink |
| 1723 | Jim | 05/21/2024 | 21582 | - installed tile by frappe machine
- replaced ceiling tile by men’s room |
| 1722 | Brendan | 05/21/2024 | 10544 | -replaced ped2, paired ped1
-ABS no trouble found
-fixed issue with idmb2
-fixed issue causing printer6 not to work |
| 1721 | Waylon | 05/21/2024 | 17371 | -Went for platen 1 not cooking 10:1 came in and found out they they scraped the carbon build up off it and has been working fine…. Tan 3 runs all by different people and all temped out |
| 1719 | Brendan | 05/20/2024 | 00596 | -troubleshooted coffee brewer not working. Replaced fill valve and tied up waterlines that were starting to kink
-replaced kiosk8 controller |
| 1718 | Brendan | 05/20/2024 | 04205 | -looked at OJ machine not temping. Box was at 35 and product temping at 38. Nuisance call
-troubleshooted cream refrigeration. Determined it to be a bad compressor, Rick will be out to check
-checked pie merchandiser bulb type to pick up on return visit |
| 1717 | Brendan | 05/20/2024 | 07194 | -lobby soda flat; many multiplex issues. Parts on order be back later this week
-fixed ped2. Cord unplugged
-took happy meal merchandiser lock, will get replacement |
| 1716 | Jim | 05/20/2024 | 02038 | - replaced ceiling tiles in play place and lobby
- replaced lot covers as needed
- fridge lite obsolete |
| 1715 | Jim | 05/20/2024 | 04205 | - replaced side door sweep
- grouted floor areas by sink and nugget fryer
- toilet issue cleared upon are
- Brendan ordering men’s room faucet cartridge
|
| 1714 | Waylon | 05/17/2024 | 02038 | -Installed new main board for UHC was then missing a full leg of power found a blown fuse to be the issue but it was a fuse that I don’t carry so had to go get. Then the old on/off switch was overrided so it was on 24/7 I replaced it with a new switch.
-Cabinet still needs to be reprogrammed but I need a layout from either drew or Kristin to program it too |
| 1713 | Jim | 05/17/2024 | 25383 | - re installed clearance bars at drive thru
- reworked ceiling above beverage area |
| 1712 | Jim | 05/17/2024 | 02830 | - repaired wall paper in vestibule and lobby
- repaired drive thru curbing |
| 1711 | Waylon | 05/16/2024 | 04205 | -Disabled the hidden temperature program on the creamer it was set to the highest heat so lowered it but it’s such a small compressor it takes a while to drop temperature so leaving it and gonna wait for a text from Lynn
-Started looking at OJ Brendan said to let him take care of it though |
| 1710 | Jim | 05/16/2024 | 10622 | - prepped and poured concrete on drive thru side by railing |
| 1709 | Jim | 05/16/2024 | 04956 | - replaced OEP plug on food warmer
- installed two mop holders, one at crew room and one up front
- installed new hands free paper towel dispenser above hand sink by nugget fryer
-grouted old holes in ladies room wall
- measured for ramp at interior freezer door
|
| 1708 | Waylon | 05/16/2024 | 00596 | -looked into leak coming into office found it coming from an AC unit and one of ricks guys were there so we went on the roof together and cleared it out but they are overdue for pms
-Also looking into a new ice bin lid there’s no model number so gonna take some searching |
| 1707 | Waylon | 05/16/2024 | 02830 | -Replaced cabinet strip burrito button was bad
-Took out old wiring for light just cut the wires where they went into freezer and I disconnected them up top so there’s no power in them at all looks like nothing was ever there 🥱🥱 |
| 1706 | Waylon | 05/16/2024 | 04956 | -Took out the AB’s censor and put a new screw hole in it and then reinstalled adjusted to the right way but if it gets moved basiclaly I’m anyway it will stop working I let them know and showed Mike how to adjust it as long as they don’t hit the censor they should be able to make it through the RGR |
| 1705 | Waylon | 05/15/2024 | 04956 | -mounter security camera monitor on to wall and cleaned up the wires
-Welded a bead on to bottom abs tray but didn’t have the results I was hoping for and found the old sensor is frayed and have both of the screws holes destroyed |
| 1704 | Jim | 05/15/2024 | 02830 | - finished sanding remaining ceiling vent covers
- replaced two ceiling tiles in vestibule
- replaced grill and rear door missing ceiling tiles |
| 1703 | Waylon | 05/15/2024 | 18198 | -raised lobby ceiling up still slightly slanted looking I put more reinforcements in it and the level says it’s level gonna talk to Jim about it but can’t see it breaking |
| 1702 | Waylon | 05/14/2024 | 02038 | -Qing oven reading “call serv” reset code because its heating perfectly fine read amp draw about 1.8-2 on all three transformers and fuses are all good I called the service tech just incase so I don’t need to make another drive out there and he said I did everything right so we good
-Replaced OEP underneath Hlz that was broken in half |
| 1701 | Jim | 05/14/2024 | 04956 | - replaced multiple ceiling tiles in lobby and crew room
- installed electrical outlet covers on light poles in parking lot |
| 1700 | Jim | 05/14/2024 | 17371 | - moved four Drive thru signs to new location and installed four new curbside parking signs |
| 1699 | Waylon | 05/14/2024 | 18198 | -Fixed register 2 card reader
-Told register 1 wasn’t working reset and working fine
-helped Allan remove a door that was wrongly placed by Glenn |
| 1698 | Waylon | 05/13/2024 | 04956 | Dropped of ceiling tiles and bent Bun toaster slider back into place for them |
| 1697 | Waylon | 05/13/2024 | 02830 | -fixed deliver driver hitting their weather strip
-ordered new strips for UHC I guess every cabinet from prince castle we have is a different model idk y we did that but okay
-bought ceiling tiles from kamco
|
| 1696 | Jim | 05/13/2024 | 04205 | - ran snake in men’s room toilet hit something about 10-15 feet in, ran snake in and out and it released |
| 1695 | Jim | 05/13/2024 | 10544 | - replaced two hand sink faucets with new hands free units
- installed new exterior door crash bar
- replaced sprinkler head |
| 1694 | Waylon | 05/13/2024 | 04205 | -Came to install washing machine latch but Mattie already did it they just didn’t tell me |
| 1693 | Waylon | 05/13/2024 | 04956 | -Diagnosed Hlz looks to be a bad motor due to description motor could’ve been burning and it’s getting 120 into both legs without spinning
-looked at abs new kid talked to Rick about it makes more sense for him to install since the ice machine needs to be taken off
- installed new grill side 1 initiating bump bar
-grabbed a ceiling tile to bring to camco
-called everbrite regarding pay here signs won’t come in until next month |
| 1692 | Waylon | 05/12/2024 | 18198 | Abs arm stuck had to lift up and clean cylinder just happens sometimes |
| 1691 | Waylon | 05/10/2024 | 18198 | Regap grill 2 and instructed them to replace pump orings both sides of shake machine |
| 1690 | Waylon | 05/10/2024 | 04205 | -Washing machine needs a new door lock assembly and strike I can order on parts select but gonna ask Brendan tonight since can’t find it on parts town
-talked to Lynn regarding men’s room toilet backing up gonna try to have Jim here Monday with the auto feeding snake (stores been able to clear it multiple times I assume something small is stuck causing random backups) |
| 1689 | Jim | 05/10/2024 | 02830 | - installed stainless steel backsplash for sink
- sent specs for OEP outlet under landing zone to Brendan to order part
- adjusted legs on cup holder table and leveled
- replaced ballast in light in stockroom
- installed new base tile in play place
- filed threads on two wheels for grill fridge and remounted
- installed cover for flag pole
|
| 1688 | Waylon | 05/10/2024 | 04956 | This was miserable, ABS conveyor not working so went to drill out the screws okay fantastic went through 2 sets of drill bits and the motor wouldn’t even split apart from it’s housing like wtf I used a hammer to bang it and a massive channel lock to try to pull it apart yeah nope, tried just about everything I could think off to get it out nothing worked so decided to put a tig weld on the bottom of where the conveyor insets to the motor which will raise it above the sensor enough for it to not have that problem I HOPE cause ABS should be exterminated in my opinion 😡🤬😡🤬 |
| 1687 | Waylon | 05/09/2024 | 04956 | -Kinda annoyed all the screws for the abs conveyor motor are stripped got one out can’t fit a drill in there to drill them out that well at all and I’m worried about damaging the motor so Brendan and I are gonna talk tonight about some type of solution to get it to work |
| 1685 | Jim | 05/09/2024 | 02830 | - removed curtain brackets between walk-in and freezer
- mounted lobby fire extinguisher
- three baseboard tiles replaced and grouted
- two wall tiles replaced and grouted
- sanded three ceiling vents four left to do
- secured walk-in threshold |
| 1684 | Waylon | 05/09/2024 | 00596 | -Replaced GFCI that was quote and quote tripping but they didn’t even know it was a GFCI outlet anyways replaced it so if any intermittent trip happens again they know to call Rick for the freezer and I cleaned up the area while I did it |
| 1683 | Waylon | 05/08/2024 | 00596 | Filet steamer main board - was a pain in the butt getting the old relay out 😭 |
| 1682 | Waylon | 05/08/2024 | 04956 | -Abs call for conveyor not moving
Attempted to raise the motor up underneath has 3 stripped screw one kinda raises it and then adjusted sensor was working when I left made 10 drinks no problem doubt it will hold long run so someone’s gonna have to drill out the screws and retap it |
| 1681 | Waylon | 05/08/2024 | 17371 | -Installed new card reader power cord and had to replace Ethernet cable the old one was destroyed
-Installed new side 2 imitate monitor and programmed with Brendan |
| 1680 | Jim | 05/08/2024 | 04956 | - installed two ceiling tiles in office
- replaced two OEP plugs by toaster |
| 1679 | Jim | 05/08/2024 | 02038 | - unclogged women’s sink drain |
| 1678 | Jim | 05/08/2024 | 04956 | - replaced two floor tiles at delivery door and grouted
- installed safety chain on CO2 tanks |
| 1677 | Brendan | 05/07/2024 | 12272 | -replaced office printer |
| 1676 | Brendan | 05/07/2024 | 10544 | -troubleshooted water under ABS. Clogged ice bin drain. Got unclogged should be all set. Took a little bit to figure out how to access it, never been in the new ABS before 👀 |
| 1675 | Waylon | 05/07/2024 | 07417 | -Installed co2 alarm
-Shake machine needed to be activated and calibrated choclate
-Talked to Alex for a while |
| 1674 | Brendan | 05/07/2024 | 07194 | -cleared frappe drain pan and blew out drain
-replace hotg monitor |
| 1673 | Waylon | 05/07/2024 | 04956 | -Replaced pressure release valve on grill
-Removed old door closer had to grout a chunk that’ was missing due to door closer than caulked all the door closer holes has to smooth out and clean up |
| 1672 | Brendan | 05/07/2024 | 00596 | -troubleshooted leak under ABS. Burst waterline going to ice machine, replace line section
-replaced capacitor/diode qing oven
-troubleshooted filet steamer not turning on, bad board, on order |
| 1671 | Waylon | 05/06/2024 | 04956 | -Finished day here
-Removed old co2 alarm system
-Cleaned the caulking from the windowsill that got smeared when trying to get the wall paper up like a month ago |
| 1670 | Waylon | 05/06/2024 | 10544 | -Installed new pneumatic solenoid platen 3
Then it went back to having gapping problems letting Taylor deal with that since Brendan and I worked on it in the passed and got it to work but it obviously didn’t stick long term
-Welded bun rack
-Fixed bun rack wheel
-Replumbed drive thru ice bin letting Brendan deal with the abs leak though
-Measure entrance door bar for order
|
| 1669 | Brendan | 05/03/2024 | 04956 | -ABS on list, was working perfectly fine whole night after I put conveyor back on
-replaced motor in dt window
-ordered oeps, bump bar, and abs ice adapter
-women’s bathroom sensor, was unplugged by a hooligan. Plugged back in and works fine |
| 1668 | Brendan | 05/03/2024 | 02830 | -troubleshooted dt lane 1 issues. Same exact issue as last time, needs a base swap. One of Jim’s guys will be here tomorrow to swap
-troubleshooted detex, no trouble found lol
-UHC strip low temp; no trouble found lol
-troubleshooted ABS leak, shocking it’s not the ABS this time. Ice machine needs to be resealed, store to call Rick |
| 1667 | Brendan | 05/02/2024 | 00596 | -finished installing interior security cameras. 7 cameras completed today. Will need to return another day for 8 exterior cameras and 1 additional window 1 cash drawer overhead view |
| 1666 | Jim | 05/02/2024 | 10622 | - replaced hand sink faucet with hands free unit
- painted ladies bathroom ceiling & needed to scrape and mud small section then repainted |
| 1665 | Brendan | 05/02/2024 | 21582 | -ran to Walmart to pick up monitor and replace hotg screen |
| 1664 | Jim | 05/02/2024 | 07194 | -replaced hand sink faucet to hands free |
| 1663 | Brendan | 05/01/2024 | 18198 | -replaced frayed muffin toaster cord that caused an entire breaker panel to trip
-replaced lid lock/strike for washing machine |
| 1662 | Brendan | 05/01/2024 | 00596 | -security cameras yayyyy installed 9 cameras and DVR
-replaced print mech FFLS |
| 1661 | Waylon | 05/01/2024 | 00596 | -Camera installation new setup process of mounting and running the wire with Brendan
-Qing oven has a bad capacitor and needs fuses ordered |
| 1660 | Jim | 05/01/2024 | 02830 | - replaced three wall tiles above office door & grouted
- replaced two floor tiles by sink
- replaced 4 floor tiles by slop sink
- installed two hand sanitizers, one at each exit
- sanded one and a half ceiling vent covers out of seven |
| 1659 | Jim | 04/24/2024 | 07417 | - removed, re shaped, and re installed freezer threshold |
| 1658 | Waylon | 05/01/2024 | 10544 | -Diagnosed platen 3 not latching needs a new solenoid
- replaced the inline restrictor and the line
- swapped the solenoids out and it began to work which is how I narrowed it down to solenoid problem then to double check no leaks went through all the fittings in the line no leaks found |
| 1657 | Waylon | 04/30/2024 | 10544 | -Grill pm with Brendan
Grill platen 3 was being super stubborn with gapping and the belt was causing the platen to lift up and down we just gapped as is since it wasn’t causing a cook problem but kinda lost cause the belt isn’t bad and the gapping block is stripped but wouldn’t be the problem |
| 1656 | Brendan | 04/30/2024 | 10544 | -left grill PM
-welded grill smallwares mount |
| 1655 | Jim | 04/30/2024 | 02038 | - painted men’s and ladies room ceilings |
| 1654 | Waylon | 04/29/2024 | 02830 | -Finished installing new co2 alarm sniffer and central and ran wires
-Fixed filet steamer totally called the regulator was bad but installed new regulator and regulator housing then installed new solenoid set that the water runs in to then be distributed the old fittings got snapped of in the lines so had to slowly break up use hot water and get them out was a mess |
| 1653 | Brendan | 04/29/2024 | 18198 | -installed new bix grill printers |
| 1652 | Brendan | 04/29/2024 | 07417 | -installed new merge monitor in 1st window
-fixed issue with ped9
-replaced Dr Pepper bib pump and changeover valve with correct model |
| 1651 | Jim | 04/29/2024 | 21582 | - re glued wallpaper in lobby
- cut, installed, and grouted baseboard tile |
| 1650 | Brendan | 04/29/2024 | 04956 | -ABS falsely detecting cup a. Motor dropped a bit, raised it up and calibrated thru beam sensor
-label maker not working, breaker somehow got turned off even though it was covered up and said wall outlet lol |
| 1649 | Jim | 04/29/2024 | 10622 | - replaced three sink faucets, on in men’s room and two in the ladies room |
| 1648 | Brendan | 04/26/2024 | 00596 | -replaced milk valve door |
| 1647 | Brendan | 04/26/2024 | 02830 | -dropped off Tara’s blowtorch
-looked at filet steamer leaking. Fittings must be worn down because the orings have been replaced multiple times. Noticed the power switch is also in bad condition. Ordered regulator assembly, solenoid assembly, and switch |
| 1646 | Waylon | 04/26/2024 | 17371 | Back door weather stripping
Lobby shade chain
Zoom timer
Loosened a nut on abs for them
Found a couple ungrouted tiles from Jim leaving for him |
| 1645 | Waylon | 04/25/2024 | 02830 | -Installed 3 new co2 alarms and ran cables
-Looked at filet steamer not working adjusted regulator and removed and replaced oring also had to replace the supply line from ceiling at the time leaving showed the manager no dripping at all |
| 1644 | Brendan | 04/25/2024 | 02830 | -called for cameras being down. Plug went bad so switched it out. When it turned on it had an alert that there was no hard drive. So the hard drive went bad. Replaced unit with spare hikvision unit I had |
| 1643 | Brendan | 04/25/2024 | 07194 | -swapped in new print mech for FFLS |
| 1642 | Brendan | 04/25/2024 | 18198 | -troubleshooted washer. Needs new lid switch, on order
-calibrated Fanta valve in lobby
-fixed ABS cup jam issue
-explained biometrics reader pain points. Dry hands will not be recognized, I usually tell people to lick their finger first if it doesn’t sense the finger is present. Thumbs tend to work better. It also works better if the scan window is completely covered, usually need to put finger higher than you think |
| 1641 | Waylon | 04/24/2024 | 17371 | -Installed new womans room touchless faucet
-Looked at grill gapped it near perfectly and the back platen kinda popped up and the temps are hit or miss having Taylor come out Brendan thinks might be a death sentence but we will see what they say
- installed lobby shade chain and new spindle
-put a short term fix on the salad fridge cover it’s just a screw and bolt it should work long term but not putting hopes on it
- installed new front door handle had to drill out old holes and angle grind the prongs out |
| 1640 | Brendan | 04/24/2024 | 04205 | -frappe machine not working, broken baffle cone and lid missing magnet. On order |
| 1639 | Jim | 04/24/2024 | 07417 | - removed, re shaped, and re installed freezer threshold |
| 1638 | Brendan | 04/24/2024 | 25383 | -ABS giving errors. Found the electrical box hanging by the wires instead of mounted. Presumably due to last time when they put screws all over the place and killed the board. Probably used wrong size and they fell out, hence the hanging box. Remounted side panel and front panel correctly, remounted electrical box. Multiple wire harnesses had torn wires due to it hanging. Repaired those so they are all up and running.
-replaced SSBS cracked merchandiser with new metal one |
| 1637 | Jim | 04/24/2024 | 00596 | - snaked and plunged the men’s room toilet and floor drain, to no avail
The store has called the septic company |
| 1636 | Jim | 04/24/2024 | 02038 | - ladies room ceiling scraped and applied drywall mud
- drain pipe fitting was cross threaded, all set |
| 1635 | Jim | 04/24/2024 | 12272 | -re installed stop sign
- replaced Quing oven OEP plug |
| 1634 | Waylon | 04/23/2024 | 10544 | -Literally the worst day ever
-Co2 alarm installed back door
-Installed bracket on bibs
-Grill was reading probe failed originally asked them to check the cords so I assumed cords was fine after a while found out it was unplugged 🤦🏻♂️ took up Brendan’s time on the phone too
Then the grill wouldn’t come out of auto leveling and I was doing motor checks and everything was seeming fine and took up more of Brendan’s time and couldn’t figure it out he just said call Taylor cause it’s taking up too much of both our times basically I sucked at my job today |
| 1633 | Jim | 04/23/2024 | 00596 | - replaced two baseboard tiles behind the meat freezer
- switched ladies room faucet to hands free |
| 1632 | Jim | 04/23/2024 | 04956 | - tile repair y delivery door, damaged by delivery driver
Shimmed two lobby tables # ‘s 124,129 |
| 1631 | Jim | 04/23/2024 | 07417 | - replaced breaker # 8,10,12 in panel AP 2 |
| 1630 | Brendan | 04/22/2024 | 04956 | -installed POS dome cameras for lane 1 and 2 |
| 1629 | Waylon | 04/22/2024 | 17371 | -replaced hi limit left side was still not reaching temp
-Checked relay which is bad but it’s stuck open which means it’s always trying to heat so that’s fine
-Checked heating element was fine
Checked hi limits again and when following the wires found the one hidden under the whole thing was frayed off and was the problem |
| 1628 | Brendan | 04/22/2024 | 12272 | -called for leak by water filter. Parts on order, needs new relief button, tank, and shutoff |
| 1627 | Jim | 04/22/2024 | 25383 | - covered crew room wall with a bulletin board
- applied contact cement to lobby drink station door panels
- replaced Nashua road vestibule floor tile
- re fastened lobby registers camera |
| 1626 | Jim | 04/22/2024 | 10544 | - Replaced broken double breaker in crew room panel #’s 24,26
- repaired six fence posts that got blown down due to winds |
| 1625 | Waylon | 04/22/2024 | 18198 | -Texted regarding printer no power the block was just unplugged from it
-Sweet tea was not brewing just needed to be switched over to pump 1 and primed |
| 1624 | Brendan | 04/20/2024 | 18198 | -mounted dr p pump on new mount on wall
-strapped bib rack to wall with bracket
-replaced cam co2 fill box
-repaired hi c leak |
| 1623 | Brendan | 04/20/2024 | 17371 | -repaired multiplex, replaced IBC probe, very crusty
-replaced leaky bypass regulator, but the new one arrived defective and was bypassing so it was too much pressure and created a leak elsewhere. Bypassed RO for now until more come in
-troubleshooted co2 leak. Frappe machine leaking from 75psi regulator. Rebuilt regulator all set |
| 1622 | Brendan | 04/19/2024 | 04956 | -replaced washing machine inlet valve and lid switch, should work good now. Of course when I turned the water back on the shutoff started leaking from the knob. Had to run to store and change it out with new one.
-replaced toaster heating elements and calibrated |
| 1621 | Brendan | 04/19/2024 | 02830 | -bix printer upgrades
-installed new office printer
-installed new music media player |
| 1620 | Jim | 04/19/2024 | 21582 | - replaced six baseboard tiles and grouted
- adjusted door closer works fine
- installed new hand sink and hands free faucet |
| 1619 | Brendan | 04/19/2024 | 00596 | -installed lid switch parts for washing machine
-called for toilet not getting water, apparently some homeless guy fixed it before I got there🤷🏻♂️
-troubleshooted kiosk, needs new controller on order
-replaced window 1 cash drawer and swapped old into pos1 |
| 1618 | Jim | 04/19/2024 | 07417 | - went to replace triple breaker, the wrong breaker was shipped
|
| 1617 | Brendan | 04/17/2024 | 07194 | -hi-c lobby. This was the most annoying problem I’ve ever had to deal with. Nothing is labeled so I had to trace lines through the ceiling. Eventually after hours of troubleshooting I figured out that there are clogs in the line in two locations, the multiplex cooling coil and the line from multiplex to lobby valve. Which is absolutely insane. I will have to run a new line as painful as it is. Project for another day-it’s 10pm I’m tired and want to go home lol |
| 1616 | Waylon | 04/18/2024 | 17371 | -Installed a new Diet Coke bib pump
-ordered a door handle
-went over list with ty |
| 1615 | Jim | 04/18/2024 | 17371 | - installed new hands free faucet in hand sink and drain required major repair work
- replaced one hand sink Rai’s in ladies room need another one
- installed light lens in stock area
- installed two mop hangers |
| 1614 | Waylon | 04/18/2024 | 07194 | -Installed new Fanta bib pump Brendan broke the old one last night working on the lobby hi c
-Welded the old holes of the fry product freezer bracket then tapped with new screws on there working mint atm warned Brendan not how positive I feel on the longevity of it and might switch to a new plate welded on but we are testing the cheapest theory |
| 1613 | Jim | 04/18/2024 | 10622 | - Put together the power washer for store |
| 1611 | Waylon | 04/17/2024 | 02038 | -Finished co2 alarm upgrade
-Installed 2 touchless dispensers and showed the manager how they work and keys |
| 1610 | Brendan | 04/17/2024 | 25383 | -flushed/sanitized Diet Coke line
-had to also flush/sanitize Coke Zero line because someone thought it would be a good idea to hook up the wrong BIB ON PURPOSE
-replaced armature tip lobby valve causing carb water to drip
-crimped new connector dt present bump bar |
| 1609 | Brendan | 04/16/2024 | 04956 | -diagnosed washing machine. Bad inlet valve, ordered that and lid switch as a precaution |
| 1608 | Waylon | 04/17/2024 | 04956 | -Finished co2 alarm installation was 2 alarms and central unit then Brendan had to help me with the crimping on the cables since it was taking me forever and I was messing it up
-Replaced fan in cream dispenser
-Took out back door tile I don’t have the right kind on my van so need to grab one from the office it’s cleaned out atm |
| 1607 | Jim | 04/17/2024 | 12272 | - ran snake thru ladies room handicap toilet to 25’, then flushed all toilets multiple times. All clear lobby open |
| 1606 | Jim | 04/17/2024 | 18198 | - Replaced one hand sink and two faucets to hands free
- Replaced men’s room faucet to hands free |
| 1605 | Brendan | 04/16/2024 | 04205 | -half of machines not working, booster pressure switch dead. Replaced all set
-frappe saying lid is off, ice got all inside stopping hopper from being seated
-tea brewer troubleshooting, no trouble found working great |
| 1604 | Brendan | 04/16/2024 | 10622 | -diet not working, replaced bib pump
-dr p connector leaking, replaced |
| 1603 | Jim | 04/16/2024 | 00596 | - replaced eight floor tiles in men’s room
- Clog cleared upon arrival
- re fastened cabinet in office
- delivery door seems slightly bent at top right / looking from outside
|
| 1602 | Brendan | 04/16/2024 | 17371 | -right grill PM
-diagnosed platen 3 with probe fail error, bad hi limit, on order.
-gapped platen 1
-crimped new connector cbb bump bar
-ordered bypass regulator for RO leak |
| 1601 | Waylon | 04/16/2024 | 17371 | -Alton grill pm with Brendan
-We diagnosed bad hi limit in plated 3
Leveled platen 1
|
| 1600 | Waylon | 04/15/2024 | 04956 | -Looked at both ice machines not making ice
- main unit had a full bank of ice but took of cover and let it make a run
- lobby ice was turned off if any problems persist let them know to have Rick take a look since he will be there tmrw for hvac
- put a bead of caulking in wall paper the material is like hit or miss if it will stick so I’m using that bead to help hold it in and I’ll go back and put another good bead
-Looked at washing machine not receiving any water when I put it on a run cycle filled up spin and drain and it’s not that I think they lied about water not going to it so I told them if any problem comes up to notify Brendan
-Installed one co2 alarm in back cash hull had to drill through two bricks so that took a while
-diagnosed cream dispenser seems bad fan since when the compressor was on the fan wasn’t and you need the fan to get rid of the heat |
| 1599 | Waylon | 04/15/2024 | 00596 | -Snaked urinal drain 3-4 times
-Snaked toilet 1 time
-Snaked main drain 1 time
Went 25 feet of snake down each of them had them call east coast
-Reprogrammed cabinet closest to Hlz |
| 1598 | Brendan | 04/12/2024 | 12272 | -repaired coffee brewer, it was a looong project because I had to disassemble the entire thing and rewire it with a new wire harness |
| 1597 | Jim | 04/12/2024 | 00596 | - replaced three had sink faucets for hands free units and made necessary repairs as need to drains |
| 1596 | Waylon | 04/12/2024 | 07417 | -Installed 2 new heater blankets one came faulty gonna start checking them before installation since this has happened two times in a row
-Installed batteries for emergency light the clips are holding on to dear life but fingers crossed
-Installed transformer plug in office |
| 1595 | Brendan | 04/12/2024 | 04205 | -replaced ABS power supply board, installed replacement conveyor I stole
-called for card reader last night, all working today though |
| 1594 | Jim | 04/12/2024 | 21582 | - replaced two hand sink faucets to hands free and on tailpiece was rotted and replaced |
| 1593 | Waylon | 04/11/2024 | 02038 | -Ice machine PM found multiple parts broken / close to death
-Need a new main board so the clean cycle works -800$ around
- Evaporator is approaching near the end of its life but we will see how long I last - 4200 $ around
- the curtain has a crack across it technically still works -300$
Working making ice right now bin is 1/5 full all those are things that will eventually break as time goes on
-Installed sniffer detector
-Installed co2 alarm in stock
-Installed co2 alarm above office
-installed co2 alarm by ice machine
Need to run cables and hook up central unit |
| 1592 | Brendan | 04/11/2024 | 02830 | -replaced back door closer
-replace back door mortise, needs new strike plate though
-repaired window 1
-repaired right coffee brewer solenoid leaking
-disables coffee heaters
-replaced Qing oven OEP |
| 1591 | Jim | 04/11/2024 | 12272 | - power snaked floor drains and toilet to max length 25’ to no avail
Store called east coast
- filled separation in wall by frappe machine
- fixed slop sink soap hose, had split in it |
| 1590 | Jim | 04/11/2024 | 25383 | - replaced six floor tiles by delivery door
- installed new weather strip at delivery door
- installed new hands free faucets on two hand sinks |
| 1589 | Brendan | 04/11/2024 | 21582 | -replaced ABS conveyor
-troubleshooted co2 leak, no trouble found |
| 1588 | Brendan | 04/11/2024 | 04205 | -came to pickup printers and steal ABS conveyor
-repaired lobby valves, 2 armature tips, micro switch, and calibration |
| 1587 | Brendan | 04/10/2024 | 18198 | -brand new shiny UHC installed and programmed both!
-spent so long troubleshooting grill printers not working. I KID YOU NOT-every printer has a dead USB port. Swapped in a new printer I had on me temporarily. Have a new box in 2nd st, will try to pick up and install tmr |
| 1585 | Waylon | 04/10/2024 | 18198 | Installed new UHC with Brendan |
| 1584 | Waylon | 04/10/2024 | 04205 | Diagnosed abs
-Looked at sink dripping that needed to be welded but actually wasn’t dripping I filled the bag up with water and got nothing
- tried to screw match for the drawers in the 4:1 fridge but found the holes were stripped out
-Put a screw in the door closer
-Talked to Matty he said he would take care of changing table |
| 1583 | Jim | 04/10/2024 | 17371 | - R& R washing machine
-R&R mixing valve |
| 1582 | Brendan | 04/10/2024 | 25383 | -ran wire and installed NEW LABEL MAKER! It’s sooo nice I love it |
| 1581 | Brendan | 04/10/2024 | 07417 | -troubleshooted emergency light per fire dept, batteries are spicy pillows 🌶️ new batteries on order
-looked at transformer fire dept said was overheating and needed to be replaced. New one on order
-looked at Dr Pepper bag “exploding”. Will put in new pump and changeover valve on Friday hopefully for return visit |
| 1580 | Waylon | 04/10/2024 | 02038 | -ice machine drain said to be clogged that’s why water was pooling but it really just looked like the water was bouncing of the drain cover so removed that and dumped 2 galleons of water down it and ran the clean cycle for the ice machine so that dumped to was going smoothly
-Fixed RTI trash job at installing the fry station automist it’s still not an amazing set up but works better now
-put 4 screws into lobby table since it was basically detached due to teenagers |
| 1579 | Jim | 04/10/2024 | 02830 | - installed new door sweep and side seal on delivery door
- installed two landscaper access boxes over abandoned concrete posts with conduits at drive thru speakers
- re bolted # 6 drive thru sign to wall
- replaced emergency exit sign above office |
| 1578 | Waylon | 04/09/2024 | 17371 | -Installed hot water hand le for dish sink
Ordered water mixer for mop sink and dish sanitizer and soap
-installed new latch switch for washing machine something bad in the motor Jim will pick up a new one I still think we should upgrade to the commercial ones but my opinion doesn’t matter |
| 1577 | Brendan | 04/09/2024 | 02038 | -eProduction screen electrical issues. Main power plug fell out. Really weird spot can’t blame them for not knowing
-replaced McFlurry spinner switch
-oven switch all set
-reinstalled entrance sign face that was banged in |
| 1576 | Waylon | 04/09/2024 | 04956 | -Installed sniffer detector
-Installed co2 alarm next to water system
- tan cables to office for power to sniffer
- ran cables to crew room to connect to other co2 alarms not yet installed ran into a brick wall in the ceiling so gonna take some time I get that figured out |
| 1575 | Brendan | 04/09/2024 | 12272 | -repaired 4 lobby soda valves
-troubleshooted right coffee brewer. its in rough condition. wiring harness is brittle and is breaking, board is dead (cause), button panel backing plate broken off. Parts on order
-store needs 20a oep, on order
-was going to install epr printer but store does not have printer. on order |
| 1574 | Jim | 04/09/2024 | 02830 | - removed damaged tiles and replaced , also grouted all new tiles and other areas on list
- hung new mop holder
- mounted hands free control box by rear sink
|
| 1573 | Brendan | 04/08/2024 | 04956 | -replaced button panel and membrane on right coffee brewer
-put ABS back together after worms
-fixed issue with eProduction, printers, register 1 |
| 1572 | Brendan | 04/08/2024 | 02830 | -troubleshooted back door alarming. Screw was loose causing tamper switch to activate
-looked at other back door harming trouble latching. The mortise dead latch is a bit sticky. Will order new mortise. Door closer also in poor condition. Will also order that. Weather stripping also in poor condition. Will add that to list
-installed new motor in window 1, however found out that it needs a new bearing as it is also causing issues. Will order
-deactivated pot warmers on right coffee brewer. Noticed water was leaking, it is coming from brew solenoid. Will put on list and fix next visit.
-replaced lid on 10:1 freezer, it now self closes |
| 1571 | Brendan | 04/08/2024 | 10544 | -replaced ped13 and cord. EMV chip not recognizing and cord very twisted |
| 1570 | Waylon | 04/08/2024 | 10622 | -Installed new side 1 imitate monitor on |
| 1569 | Jim | 04/08/2024 | 02830 | - installed new ADA plate at ramp
- re attached black apron at front counter
- sourced and replaced bottom door of double fridge
- installed new toilet seat in ladies room |
| 1568 | Jim | 04/05/2024 | 02830 | - replaced men’s room faucet to hands free
- re attached wallpaper in crew room and dining area
- replaced milk control unit
- remounted trim piece on trash bin holder |
| 1566 | Waylon | 04/05/2024 | 25383 | -Snaked abs drain
-Rearanged abs hoses going into drain one was stuck down the whole drain I believe main clog problem (ran ice machine 2 drain cycles and ran root beer down drain for a minute straight no back)
-Left snail fan in Milford
-Welded grease traps multiple spots not 100% sure where the leak was coming from hopefully took care of it |
| 1565 | Jim | 04/05/2024 | 00596 | - snaked floor drain in ladies room and plunged lines to no avail
Sewage coming up from both bathroom floor drains and the new floor tiles in men’s room will need to be reset after the drain company is done.
- Replaced broken corral board and bolted gate pin back on
- Grouted baseboard tiles behind bun racks |
| 1564 | Waylon | 04/05/2024 | 10544 | -Installed 2 new door handles
-Installed new solenoid made a slight oops and cut the sensor wires too repaired those and finished solenoid install ran it 15 times works like a gem 💎 |
| 1563 | Brendan | 04/05/2024 | 10622 | -called for ABS broken nozzle and pulling triple cups. Replaced nozzle and tuned up cup fingers
-grabbed LCM bump bar, don’t have any spares of those so will need to repair and bring back next visit |
| 1562 | Brendan | 04/05/2024 | 07194 | -called for front lobby door not unlocking. Dogging mech got loose and slid over. All fixed |
| 1561 | Brendan | 04/05/2024 | 04205 | -replaced prep line heat blankets BUT side 2 blanket came defective. Will have to order replacement. At least side 1 is working now |
| 1560 | Waylon | 04/05/2024 | 04205 | Installed new heaters for side 1 and 2 with Brendan was not as bad as I thought it was gonna be instead of putting it fully under the table we cut a piece out so it fit around perfectly one heater came defective but side 1 has heat now 🥳 |
| 1559 | Waylon | 04/04/2024 | 18198 | -Installed new Hlz temp probe
-Installed new switch for UHC based diagnosis of what they said can’t test anything else without power
- looked at slanted ceiling I see the two points it could use hangars but my drills at the office and they need two ceiling tiles (black special) and those are also at the office |
| 1558 | Brendan | 04/03/2024 | 04956 | -now that coffee brewer is dry I troubleshooted. Luckily only thing that’s bad is the button panel. New one on order
-pilot test cases |
| 1557 | Waylon | 04/03/2024 | 21582 | -Replaced HLz cord that was yellow whoever did that needs to seek help all the wires inside Hlz were frayed and cracking so took a lot of extra work to get those out replaced with all new terminals and took out 2 old ground wires
-Diagnosed Hlz with assistance for bad plate heater that Hlz was giving me mixed signals 😭
-Replaced fuse in the other Hlz and put screws on it so it can’t wiggle than watched the crew set it on the ground so they could put pizza on the crew room table 🤦🏻♂️ I wonder why half the things breaks
Grabbed fridge door for Hooksett from shed |
| 1556 | Brendan | 04/03/2024 | 02038 | -measured lobby tables for ordering
-troubleshooted fry hopper. Gear motor was loose, tightened up working now.
-ordered McFlurry spinner button, out again at hardware store |
| 1555 | Jim | 04/03/2024 | 12272 | - installed weather stripping on new door
- replaced door closer on freezer door
- reinstalled chain on present window |
| 1554 | Jim | 04/03/2024 | 00596 | - replaced 8 floor tile in men’s bathroom floor, also had to level up repair
- filled crack in countertop at lobby drink station
- |
| 1553 | Brendan | 04/03/2024 | 00596 | -abs erroring. Low bin sensor broke off. Removed and bypassed |
| 1552 | Brendan | 04/03/2024 | 07194 | -installed new filter system all hooked up and working!
-replaced music media player, music now working. |
| 1551 | Waylon | 04/03/2024 | 04205 | -Attempted to install new heater blanket for table is a much bigger project than I assumed I removed the old blanket in side 2 but I believe the whole table has to be taken of for it gonna reapproach it Friday with Brendan I think unless something comes up
-Moved camera to cover back door for when Martin browser breaks things
-installed new exit sign
- marked off weather strip I got some but found Jim did it just never removed it from the list 😔 |
| 1550 | Brendan | 04/02/2024 | 04956 | -troubleshooted leaking coffee brewer that wasn’t working. Huge hole in water line on inside. Unable to diagnose with how wet it is. Unplugged it and took panels off so it can dry. Will be back tomorrow for troubleshooting/fix
-troubleshooted dt window. Dead motor already it’s only a year and a half old! On order, will replace tomorrow when I’m here for the coffee brewer
-replaced ABS auger, can now use with ice
-calibrated grill hand sink
-replaced shamrock syrup motor |
| 1549 | Waylon | 04/02/2024 | 10544 | -Diagnosed milk not dispensing needs a new solenoid was receiving voltage from board but not operating
-Installed HLZ latch relay
-Installed 6 cabinet strips
-Put a new screw in handicap button should work for now it needs the left screw hole to be tapped since the threads have started to go but working perfectly good right now
- ordered 2 new door handles screws are stripped and broken off inside the handles |
| 1548 | Brendan | 04/02/2024 | 07194 | -ran lines and set up new vzn filter system. Need to come back in morning to make final connections. Also noticed that booster pump was bad. Will replace in morning as to not disrupt water
-fixed issue with cash drawer 13 cable |
| 1547 | Jim | 04/02/2024 | 00596 | - wrapped drain and water lines under men’s room sink
- checked ladies bathroom toilet found no leaks (flushed multiple times no leaks at all)
- sourced floor tile for men’s room floor repair |
| 1546 | Jim | 04/02/2024 | 04956 | - re-cemented wallpaper in lobby
- replaced hand sink strainer and cleared clog
- remounted pay/pickup here signs |
| 1545 | Brendan | 04/02/2024 | 18198 | -attempted to fix front door. What a MASSIVE pain those continuous hinged. Wouldn’t come off without breaking. Will order new hinge |
| 1544 | Waylon | 04/02/2024 | 18198 | -Looked at Hlz they never run side 2 so made sure it heated up I think it still gives a code after like 2 hours and I have the part in the van but until they actually use it for me to see the code then I’ll fix
-Started uninstalling the door with Brendan needs a new hinge after finding like 3 stripped screws we are deciding to wait for it to come in the mail before we take the whole door off |
| 1542 | Jim | 04/01/2024 | 02830 | - replaced white ceiling tiles
- cleaned and reinstalled wood ceiling lobby tiles
- R&R front hand sink and faucet to hands free
- flipped handicap table top |
| 1543 | Jim | 04/02/2024 | 02830 | - rebuilt IT closet door and installed new lockset |
| 1541 | Waylon | 04/01/2024 | 17371 | -Took apart dish sink faucet found a warped spring causing the whole contraption to not stick together which makes the cold water never allowed to go through
-Took apart men’s room hand sink to replace battery found it to be not the same battery as normal it was a CR-P2 normally found at drug stores per Brendan, but then found they are even more irregular so drove 45 mins to find out they aren’t sold in store anymore
-Picked up a new wall mount for fire extinguisher and picked up a couple spares for future mounts |
| 1540 | Brendan | 04/01/2024 | 00596 | -troubleshooted cash drawer 13. Bad tray, swapped with register 1 for new, new tray on order
-troubleshooted lemonade not dispensing. Calibration was really low, recalibrated and issue is fixed |
| 1539 | Brendan | 04/01/2024 | 02830 | -replaced boot on coffee brewer tap
-reprogrammed Qing ovens with correct times
-diagnosed first window issues. Bad motor, also needs new manual latch and latch solenoid. On order
-installed ABS splash guard
-ordered parts for 10:1 freezer, men’s room faucet, and ADA pad |
| 1538 | Waylon | 04/01/2024 | 10622 | Replaced 2 cabinets strips
Started clearing out ice for bulk ice pm then power has been out for ten minutes now heading to Alton for the rest of my agenda |
| 1537 | Brendan | 03/29/2024 | 25383 | -dead dt runner monitor. Ran out of monitors and they are on backorder so had to go to staples and get one |
| 1536 | Brendan | 03/29/2024 | 04205 | -ABS grip sensor fail. Needed new umbilical, replaced and calibrated |
| 1535 | Brendan | 03/29/2024 | 04956 | WORMS🪱 |
| 1534 | Waylon | 03/29/2024 | 12272 | Called for drain backing up flooding bathrooms into lobby got there and looks perfectly fine flushed each toilet 3 times and the urinal 2 times no back up then was told someone dropped a linens down the mop sink went Outback ran the mop sink water for 2.5-3 minutes and no problem at all |
| 1533 | Waylon | 03/29/2024 | 04956 | -Grouted underneath ABS
-Replaced two cabinet strips on UHC closest to Hlz |
| 1532 | Waylon | 03/28/2024 | 02038 | Pipe and doped co2 pressure relief lees of a leak still a minor leak somewhere but they can get coke tmrw and talked to Doug for a little |
| 1531 | Waylon | 03/28/2024 | 21582 | -fixed plumbing on dt ice bin so it now goes into the drain and not onto the floor and yes it’s purposely tilted at and angle so water flow will be consistent
-Installed new frappe machine cord
-Installed new co2 alarm and ran wires to the existing to connect operational✅
-Grouted around ice bin drain and set up snail fan to dry it all out since it’s like a swamp back there and I don’t need more worms 🪱😭 |
| 1530 | Waylon | 03/28/2024 | 00596 | -Call that grill wasn’t heating up - they didn’t plug in both wires after cleaning behind the grill it’s a flipping twist lock like not hard to understand but whatever waited for grill to heat up waisted my time 🤦🏻♂️🤦🏻♂️🤦🏻♂️🤦🏻♂️🤦🏻♂️ did a run of sausage all temped out |
| 1529 | Waylon | 03/27/2024 | 02038 | -removed old pressure relief put new one on I need to pipe and dope it but I don’t have my van so that’s tmrw
-Reprogrammed 2 cabinets to fit almost every item took board from cabinet closest to Hlz to get sent to myers for repairs |
| 1528 | Waylon | 03/27/2024 | 00596 | -Installed new latch switch for grill platen 2 have to take the whole back side of and then unscrew the bolt that holds it in
-Installed new distribution board for UHC
-Installed new power supply board for UHC
-Installed new communication board for UHC
-Readressed UHC been doing it wrong needs to be in admin settings for the whole cabinet to be adjusted
-Tried fixing the flood in the bathroom got stuff all over myself told them to call east coast they came out unclogged it
-Got out on hold for a long time originally about the UHC found them to be unhelpful they basically condemned it to death then I figured it out |
| 1527 | Waylon | 03/27/2024 | 00596 | -Supplies for Hanovers list
-One cabinet strip then asked by Michael to go to south willow for drain |
| 1526 | Waylon | 03/26/2024 | 04956 | Dropped snail fan in Raymond for under abs drying |
| 1525 | Waylon | 03/26/2024 | 21582 | -Stopped to get a list for size of piping needed and clip sizes for plumbing will pick up in the AM
- hopefully find Hlz fuses at the store and screws I can make work
-Took quick look at filet steamer cord needs to just be shortened I believe and cabinet strips discussed with Shannon about what are highest priority ones for the morning
|
| 1524 | Waylon | 03/26/2024 | 10544 | -Went for grill home switch not being seen error installed new home switch then found by following the screws that were originally in it the bar wouldn’t press the switch down far enough to register the home switch was there removed one screw and tilted a tiny bit diagonal and screwed one screw tight
-Went to gap grill the gapping screws are DESTROYED so got to gap one down the rest don’t pass the go no go test which is fine barely off ran two runs of 10:1 all temped around 165 worse case they can up the seconds till we pm it and I can get some stuff for the stuck screws |
| 1523 | Brendan | 03/25/2024 | 04956 | WORMS AGAINNNNNNN AGHAGHAG |
| 1522 | Waylon | 03/25/2024 | 04205 | -4 cabinet strips 3 in the farthest from HLZ and 1 in cabinet closest to Hlz
-Looked a milk McCafé not working. Just to find there was only milk stuck in the little tube and the manager goes I don’t get paid enough to check that like bruh I found it in less than 3 minutes god forbid you need milk to sell coffees
- began replacing filet steamer cord little did I know the massive project I was about to start because to get to the cord you have to take the filet steamer all apart which is a pain in the ass and then resemble it once I put it all back together found it wasn’t steaming in the process of separating it the water line into it popped out so easy fix then adjusted regulator from over steaming
-all for all I hate filet steamer cords so let’s not break them |
| 1521 | Brendan | 03/25/2024 | 25383 | -ABS no power after cleaning. Many issues. Outlet tripped, blew fuse on ABS, ruined a board, two connectors disconnected, kinked air line, and front panel not put on correctly. All is fixed and working
-replaced muffin toaster heating elements and high limit
-staged kiosk 7 and paired card reader
-tested dual point. Was serving off orders just fine
-investigated leak under ABS. This time was caused by ice bin hose not in the drain.
-troubleshooted label maker. This time the sensor is broken because it looks like someone ruined it by shoving a screwdriver or something in there. Store will wait for new label maker to arrive |
| 1520 | Brendan | 03/25/2024 | 21582 | -repaired leak behind coffee brewers. Water system is such a disaster nothing is correct lol
-noticed other leaks so troubleshooted those. Leaks coming from front ice bin and side of frappe machine. On order
-noticed other issues that I added to list and ordered parts for |
| 1519 | Brendan | 03/21/2024 | 10544 | -replaced motor on platen 2 butttt apparently I misdiagnosed it because it actually needs a latch switch. On order
-replaced and configured new zoom CCU |
| 1518 | Brendan | 03/21/2024 | 00596 | RGR |
| 1517 | Waylon | 03/21/2024 | 10544 | Installed new motor into platen 3
- found bad home switch in platen 3
Waited for Brendan to finish zoom timer |
| 1516 | Waylon | 03/21/2024 | 00596 | -Resecured 10:1 freezer bottom cover
-worked on cabinets reprogrammed 2 full slots and had a new communication and distribution board ordered for 3rd cabinet guy on the phone was in fact wrong |
| 1515 | Brendan | 03/20/2024 | 17371 | -fixed WiFi issue, rebooted Aruba
-swapped creamer condenser fan direction |
| 1514 | Waylon | 03/20/2024 | 00596 | -Stupid cabinet took up a lot of my time and Brendan’s
-Replaced 2 strips on cabinet
- swapped display board on top slot
- tried to reprogram slot
- tested a new com board and main
None of that solves the problem and called service tech told it to get readdressed so asking drew to do that in the morning I doubt it will fix it though also was using parts from office so who knows if those are good
- replaced weather strip on back door top row
- angle grinder lobby chair to get the bolts off
- remove co2 sniffer
- liquid nails bottom of lobby table |
| 1513 | Brendan | 03/20/2024 | 10622 | -WiFi was working in store when I arrived, no issues there
-zoom had error screen, reset CCU working now
-measured back doors for push bars
-noticed Curtis coffee brewer down on a fill error. Reset unit and filled right up, must’ve been cleaning and knocked water line out |
| 1512 | Brendan | 03/20/2024 | 00596 | -RGR prep
-replaced muffin toaster cord and OEP
-replaced Qing oven OEP
-resecured lobby stool
-repaired leaky dish sprayer hose |
| 1511 | Brendan | 03/20/2024 | 12272 | -replaced other broken belt in shake machine. Waited to come down to temp all set
-ran to staples to get iPad cord |
| 1510 | Brendan | 03/19/2024 | 12272 | -repaired shake machine, replaced agitator belt and reassembled. Ice cream is working great. Shake was not working properly. Apparently when they accidentally turned it on the other day it blew a belt. Not their fault though, just a happy coincidence. Everyone is closed where I can get a belt so I will be back in the morning to get shake side up for lunch |
| 1509 | Brendan | 03/19/2024 | 00596 | -left grill PM, INSANE had to take a power tool to get the carbon off lol. All shiny and working good. Also had to replace a broken belt
-replaced detex mag switch that was broken off
-converted window 2 to manual with blank header |
| 1508 | Jim | 03/19/2024 | 02830 | - replaced two fry bulb sockets
- grouted by office |
| 1507 | Jim | 03/19/2024 | 00596 | - grouted floor tiles by delivery door
- replaced lite lens in kitchen area
- replaced six baseboard tiles & one floor tile … in stock room area , in fridge, and by office. Grouted all replaced tiles |
| 1506 | Waylon | 03/18/2024 | 00596 | Installed emergency light the wiring was so goofy it was crazy took a lot longer since it was ass backwards
Diagnosed Qing oven for bad HV board |
| 1505 | Jim | 03/18/2024 | 00596 | - removed and installed 21 floor tiles by delivery door |
| 1504 | Waylon | 03/18/2024 | 07417 | -Remounted sink to wall
-Replaced 3 UHC strips on cabinet closest to hlz bottom 3 slots |
| 1503 | Brendan | 03/17/2024 | 17371 | -replaced left motor platen 1
-left grill PM |
| 1502 | Brendan | 03/16/2024 | 25383 | -MIM |
| 1501 | Brendan | 03/16/2024 | 12272 | -troubleshooted shake machine not going through heat cycle. Two issues, pump stem missing and agitator belt broke. I will order belt, store needs to brush clean, install PM kit, and install the missing parts wherever they are |
| 1500 | Brendan | 03/16/2024 | 02038 | -ER3 MIM |
| 1499 | Brendan | 03/16/2024 | 04956 | -called for shamrock issue. Was very hard to troubleshoot because it was so intermittent. Finally found the issue, bad pump motor. Will order
-fixed issue with tablet wifi |
| 1498 | Brendan | 03/16/2024 | 07417 | -MIM |
| 1497 | Brendan | 03/16/2024 | 18198 | -fixed register 2 drawer opening issue
-MIM
-troubleshooted UHC, needs switch on order |
| 1496 | Brendan | 03/15/2024 | 17371 | -troubleshooted grill. Bad motor, will be back with a spare tomorrow
-replaced both tea brewer syrup pressure switches |
| 1495 | Brendan | 03/15/2024 | 12272 | -diagnosed bun toaster system A faliure, will order new relay |
| 1494 | Brendan | 03/15/2024 | 25383 | -repaired shake machine, hose fell off, recrimped. Shake pump also not even put together.
-repaired co2 hose on FCB the blew off
-installed kiosk7 controller |
| 1493 | Brendan | 03/15/2024 | 07194 | -went for fryer breaker tripping, was actually the vent hood motor as I suspected in the first place, Rick is there fixing now
-repaired hi-c lobby valve not dispensing syrup |
| 1492 | Jim | 03/14/2024 | 25383 | - filled two large potholes in parking lot
- cleaned and re positioned drive thru curbing
- finished drywall in crew room
|
| 1491 | Jim | 03/14/2024 | 10544 | - patch multiple potholes in parking lot |
| 1490 | Waylon | 03/13/2024 | 00596 | -Diagnosing grill I believe it’s a cylinder cleaned the whole pneumatic system for right side Brendan will double check when we go back to PM
-Had to turn around and wait 30 minutes in traffic because their screens are turned off I get there and the power cord to the block is unplugged 🤯🤯 I wonder why it’s turned off |
| 1489 | Jim | 03/13/2024 | 25383 | - applied last coat of drywall mud on crew room wall
Needs final sanding and then reinstall wall paper
- replaced flush handle on men’s room urinal
- replaced damaged weatherstripping on delivery door |
| 1488 | Jim | 03/13/2024 | 10544 | - reset six fence posts with two by fours that got blown down from high winds |
| 1487 | Waylon | 03/12/2024 | 07417 | - dish sink sprayer rebuild |
| 1486 | Waylon | 03/12/2024 | 17371 | -Installed new front counter runner monitor
-Removed and install new vga cables for drive thru monitor to fc monitor
-resecured cables to mount neat ish
- looked into frozen beverage being strong came out perfectly fine when tested brix setup |
| 1485 | Jim | 03/12/2024 | 21582 | - replaced weather stripping at both doors as needed
- sourced and installed locking outlet cover for misting system plug ( someone keeps unplugging it at night) |
| 1484 | Jim | 03/12/2024 | 10622 | - Swapped out flush control and button on ladies room toilet
- re fastened men’s room door frame |
| 1483 | Waylon | 03/11/2024 | 21582 | -Replaced bottom muddled sink gasket
-replaced oring in faucet for dish sink
-Replaced fuse in Hlz that kept blowing found a charred wire going into the latch relay fixed that and got screws for it so people wouldn’t bump into it and blow more fuses hopefully that was the problem |
| 1482 | Jim | 03/11/2024 | 02830 | Swapped out door bell for rear door |
| 1481 | Jim | 03/11/2024 | 12272 | Installed two fire extinguisher hangers |
| 1480 | Jim | 03/11/2024 | 04956 | - installed new hands free faucet by nugget fryer
- replaced sink drain rubber gasket and cleared slow drain |
| 1479 | Jim | 03/11/2024 | 02038 | - installed new hands free faucets at both hand sinks |
| 1478 | Waylon | 03/10/2024 | 21582 | -Bulk ice machine PM |
| 1477 | Brendan | 03/08/2024 | 25383 | -repaired shake machine, replaced two solenoids, added glycol purged air and checked for leaks, replaced one clogged air line
-replaced FFLS print head |
| 1476 | Jim | 03/08/2024 | 10544 | - Added new hook to remount drive thru clearance bar
- replaced five floor tiles y rear door and grouted
- Replaced six wall tiles behind lobby registers
- purchased and replaced sink spray hose and spring ( spring broken and caused flex water line to break)
- repaired handicap switch cover
- tightened drive thru side exterior door handle |
| 1475 | Brendan | 03/07/2024 | 00596 | -fixed abs no carb water, replaced armature and solenoid
-recrimped hotg bump bar cable |
| 1470 | Brendan | 03/07/2024 | 21582 | -installed air gap under SSBS per health dept |
| 1474 | Waylon | 03/07/2024 | 04956 | 2 strips in 2 different cabinets farthest from Hlz bottom row side 2 and side 1 middle cabinet top strip |
| 1473 | Waylon | 03/07/2024 | 00596 | -Finish installation of co2 alarm
- central unit and uninstalled old central unit from office
-Ran wires from stock room to office
-Had a small problem when two alarms wasn’t lighting up found it to be a cord that was crimped wrong and replaced that cord all set and tested
-raised diode on sniffer for elevation |
| 1472 | Waylon | 03/07/2024 | 00596 | -Shop vacced all water under abs and grouted the area Brendan put on the cover before I grouted so I got mainly outside needs to be deep cleaned by store / crew |
| 1471 | Jim | 03/07/2024 | 21582 | - installed new mop hanger over slop sink |
| 1469 | Jim | 03/07/2024 | 25383 | -Installed corner bead at first drive thru
- Replaced 7 floor tiles at drive thru #1 and grouted
- R&R two corner baseboard tiles by office and grouted
- installed 12 tiles by drive thru side of lobby by vestibule and grouted
- sanded and built us large holes in crew room wall stool needs finishing |
| 1468 | Brendan | 03/07/2024 | 12272 | -regrout and replumbed all ABS plumbing, removed old drain line as well |
| 1467 | Brendan | 03/07/2024 | 07417 | -swapped over coke tank pressure relief
-calibrated faucet sensor range
-removed power supply from sensor that was snaking around the wall lol |
| 1466 | Jim | 03/06/2024 | 10622 | Checked ladies room flush control issue and need new flush control unit
Gave Brendan info to order |
| 1465 | Jim | 03/06/2024 | 04205 | Patched pothole in handicap spot
|
| 1464 | Jim | 03/06/2024 | 00596 | - installed drive thru pay here , & pick up here signs
- Replaced all connection seals, snaked, and used gallon of drain cleaner drain finally cleared someone dumped grease down drain
|
| 1463 | Brendan | 03/06/2024 | 12272 | -repaired RO system. Has been broken for years apparently. They even put is a bypass because of it being broken. Bypass regulator was faulty, replaced. Flow control was also clogged and faulty, replaced that’s as well. Now working as expected and filling the tanks. |
| 1462 | Jim | 03/06/2024 | 02830 | - replaced teflon bun toaster belts |
| 1461 | Brendan | 03/05/2024 | 00596 | -troubleshooted leak under ABS. big clog in drain pan, cleared all set.
-replaced booster switch and added wire strain reliefs
-fixed down kiosk
-troubleshooted emergency light. Bad board, random brand had to order new unit
-replaced detex battery |
| 1460 | Waylon | 03/05/2024 | 00596 | -Installed 2 co2 alarms one by office door and one near auto mister
-Installed sniffer pulled wire only to first light ran into some problems and called it a day
-Ran wires from co2 alarms together
-Looked at bent metal where the grill grease traps are will get unbent when pm happens this week or next |
| 1459 | Brendan | 03/05/2024 | 04205 | -replaced card reader cord |
| 1458 | Waylon | 03/05/2024 | 25383 | -Fixed Hlz sparking and tripped breaker two terminals blew
-Looked at hot water heater had bad lower temp probe fault just unplugged and plugged back in has multiple faults over a 20 day period seems to always kick back on though the heater is on its death bed though |
| 1457 | Brendan | 03/05/2024 | 25383 | -installed new solenoids on shake machine butttt ran into more issues. Glycol level low so didn’t make it through heat cycle, clogged vanilla air line, and taylor sent me the wrong solenoids. |
| 1456 | Jim | 03/05/2024 | 02830 | - remounted security cover on office thermostat |
| 1455 | Jim | 03/05/2024 | 12272 | - replaced hand sink faucet with hands free unit
- replaced crash bar on rear lobby door |
| 1454 | Brendan | 03/05/2024 | 18198 | -replaced air probe grill fridge
-replaced shutoffs on vizion
-repaired dt window no power, wires broke off, still has an issue I’ll need to order parts for |
| 1453 | Waylon | 03/05/2024 | 18198 | - replaced temp probe in 2 door pull out fridge grill (had to take the whole thing apart to get to it) |
| 1452 | Jim | 03/05/2024 | 12272 | - Re installed clearance bar at drive thru #2
- Re installed pay here and pick up here signs |
| 1451 | Waylon | 03/04/2024 | 04956 | Diagnosed middle cabinet bad 2 slots not working
-Board 3 has a faulty cn2 port and board 4 has a faulty rear display port |
| 1450 | Brendan | 03/04/2024 | 12272 | -replaced ABS drain pan, sensors, and super seal. Replumbed to drain
-installed drain for ABS staging tray and plumbed to drain
-er3 per corp |
| 1449 | Waylon | 03/04/2024 | 02830 | -Looked into Qing oven not heating ran 1 burrito, 6 burrito, 3 hotcakes all in front of Mary came out perfectly fine
-ordered door switch for right qing oven since it is slowly becoming faulty |
| 1448 | Jim | 03/04/2024 | 04956 | -R&R sink faucet by oven
- checked for water around slop sink and spoke to Mike the manager who stated the drain under the multiplex is the issue
|
| 1447 | Waylon | 03/04/2024 | 00596 | -Replaced 5 brackets that hold the grill vents up had to pull both grills and could only do one at a time due to it being lunch and they needed to cook
-Looked into Qing oven not heating ran perfectly fine but tested transformers for amperage and resistance, obviously checked the fuses first for continuity, then tested capacitors and thermal cut outs all came back fine ran it again came out good
-Tightened Qing oven blower fan screws since it was wobbles when it ran |
| 1446 | Jim | 03/04/2024 | 07417 | R&R three hand sink faucets, converted to hands free |
| 1445 | Brendan | 03/01/2024 | 12272 | -called to store for flooding behind front counter. Ice machine drain line came disconnected from inside dispenser. Must’ve been shaken loose from Jim working on the clog yesterday. Fixed issue and put snail fan and took door off to dry area out |
| 1444 | Brendan | 03/01/2024 | 07194 | -er3 per corp |
| 1443 | Brendan | 03/01/2024 | 25383 | -troubleshooted platen 2 home switch. Two broken belts. Replaced and gapped
-replaced card readers 6 and 7. Ordered new kiosk controller for kiosk 7 fan failure
-troubleshooted shake machine not dispensing shamrock or vanilla syrup. Two bad solenoids and a broken header. I have that at the office so I will return hopefully Monday to replace |
| 1442 | Brendan | 02/29/2024 | 04956 | -removed hanging clearance bar
-tightened faucet in men’s room
-fixed issues with kiosk 6 and 8
-replaced side 1 breakfast monitor
-tightened ABS grabbers |
| 1441 | Jim | 02/29/2024 | 12272 | - replaced #18 breaker on second panel by sink
- painted siding on Drive thru, darter repair
- removed drain cup and trap, cleaned and reconnected
- |
| 1440 | Brendan | 02/29/2024 | 12272 | -troubleshooted leak under ABS. cracked drain pan, will be back on a morning soon to replace
-troubleshooted creamer high temp. Was at temp, no trouble found
-troubleshooted rear lobby push bar. Bad shape, am ordering a new one to match the others
-troubleshooted leak in lobby, clog in trap, Jim arrived and is now dealing with it |
| 1439 | Brendan | 02/29/2024 | 02038 | -called for card reader no power. Was unplugged even though I was assured that they checked
-troubleshooted cabinet with hi temp alarm. Bad board. Will wait for drew reprogram the other two so I can steal the board
-troubleshooted campus issue trainer tracking |
| 1438 | Jim | 02/29/2024 | 10622 | - painted stains in ladies room ceiling
|
| 1437 | Brendan | 02/28/2024 | 02830 | -troubleshooted emergency lights. Bad batteries, went to batteries plus to pick up and install. All test and tested
-measured up front hand sink for replacement with splash shield per the health department
-ordered splash shield for ABS and rebuild kits for coffee brewer faucet |
| 1436 | Jim | 02/28/2024 | 12272 | - ordered correct breaker
- caulked new siding by drive thru
- hand sink cold handle retightened
- replaced all stained ceiling tiles |
| 1435 | Brendan | 02/28/2024 | 10622 | -repaired right grill, new compressor and check valve. Cylinder rebuild and leak fixes
-programmed burritos for epr |
| 1434 | Jim | 02/28/2024 | 10622 | -installed new screw in cover plate on delivery door handle
- Grouted by slop sink
- filled hole behind printer in office |
| 1433 | Jim | 02/27/2024 | 12272 | - removed and replaced damaged siding at corner of drive thru
- fastened drain hose on frappe machine to keep from pulling out of drain |
| 1432 | Brendan | 02/27/2024 | 17371 | -troubleshooted tea brewer, bad pressure switches again, on order
-troubleshooted multiplex, IBC probe on order
-installed new recessed light behind front counter |
| 1431 | Brendan | 02/27/2024 | 10622 | -bix printer refresh with USB |
| 1430 | Jim | 02/27/2024 | 10622 | -replaced paper towel dispenser with hands free unit by hand sink
- replaced men’s room soap dispenser with hands free unit
- installed new screw in ladies room handicap toilet door
- re attached Formica in office counter
- removed broken oj machine and dropped off at the office |
| 1429 | Jim | 02/26/2024 | 17371 | -remounted walk in closer
-checked exit aign all lights operating
- reset six drive thru signs
- worked with Jamie to secure a freezer truck for store due to main freezer broken/ waiting for parts |
| 1428 | Jim | 02/26/2024 | 21582 | Foamed hole in wall by side two hand sink
- Grouted baseboard tiles by walk in |
| 1427 | Jim | 02/26/2024 | 04956 | - Grouted front floor area by ice bin
- Grouted corner baseboard tiles b delivery door
- installed cover plate on electrical box in crew room
- shimmed CO2 tank |
| 1426 | Brendan | 02/26/2024 | 07417 | -repaired shake machine, replaced draw solenoid. First time, was a learning experience |
| 1425 | Brendan | 02/26/2024 | 10622 | -troubleshooted platen not latched. Sounds like it’s only in the morning which indicates a cylinder rebuild is needed. Also noticed that compressor would not build enough pressure even after isolating, so needs a new compressor. On order |
| 1424 | Brendan | 02/23/2024 | 02830 | -replaced blue raspberry expansion tank |
| 1423 | Brendan | 02/23/2024 | 00596 | -unclogged mens urinal
-replaced FFLS print head |
| 1422 | Brendan | 02/23/2024 | 18198 | -adjusted ice thickness probe ABS watched for a few cycles to verify |
| 1421 | Jim | 02/23/2024 | 17371 | - replaced ceiling tiles that were stained
- installed new ceiling tiles above new water distribution system
- re installed shelf above sink
- checked why walk in door is tilted to the left and found the bushings are gone. Need new top hinge only |
| 1420 | Jim | 02/23/2024 | 10622 | Replaced weather strip on delivery door |
| 1419 | Waylon | 02/22/2024 | 17371 | -Installed co2 alarm above washer area and ran wire
-Installed co2 alarm crew room and ran wire
-Looked at grill issue seems to be 100% a gapping problem |
| 1418 | Brendan | 02/22/2024 | 04205 | -picked up package
-troubleshooted side 1 table no heat. Needs new pad, on order |
| 1416 | Jim | 02/22/2024 | 04956 | -installed clamp on ice bin drain pipe
- replaced floor tile in front of ice bin
- replaced tiles by delivery door
- filled holes in men’s room wall tile
- sealed outside trash bins
- attached aluminum plate behind pie merchandiser to prevent it from falling off the counter
- Tightened men’s room toilet bowl |
| 1417 | Brendan | 02/22/2024 | 02830 | -QMP follow-up: replaced vizion tank, internal RO tank, RO blending assembly
-installed syrup diffuser in ABS
-replaced batteries in two handicapped door buttons. They were installed wrong. Also had to re-pair the buttons
-installed overflow fitting on left coffee brewer
-unfortunately expansion tank for FCB didn’t arrive. Will be back tomorrow for it |
| 1415 | Waylon | 02/22/2024 | 10622 | -Finished co2 alarm just need to put up signs |
| 1414 | Jim | 02/22/2024 | 00596 | - cleared men’s room toilet clog |
| 1413 | Jim | 02/22/2024 | 21582 | - removed and replaced 1 floor tile (cut required) and 2 baseboard tiles ( 1 cut required) damaged by Martin Brower driver
- swapped out baby changing station |
| 1412 | Jim | 02/21/2024 | 12272 | - door seal replaced on delivery door
- baby changing station replaced in ladies room |
| 1411 | Jim | 02/21/2024 | 25383 | - installed new weather strip on delivery door
- filled holes in crew room wall ned to revolt and finish sanding
- repaired rolling shelves in stock room
- replaced lite ballast in lobby lite above high top table |
| 1410 | Waylon | 02/21/2024 | 04205 | Installed new main board for toaster |
| 1409 | Brendan | 02/21/2024 | 04205 | -replaced main board bun toaster |
| 1408 | Brendan | 02/21/2024 | 10544 | -recalibrated ice on ABS
-large dropping multiple cups, bent fingers in
-fixed cash drawer. Spring fell out |
| 1407 | Waylon | 02/21/2024 | 10544 | -Diagnosed HLZ needs new latch relay not a serious problem had to clean the motor out so air flow is better but the latch relay is on its way out the door |
| 1406 | Brendan | 02/20/2024 | 04956 | -ABS not lifting. Having clearance issues. shimmed shroud with washers |
| 1405 | Waylon | 02/20/2024 | 04205 | Installed new motor board for bun toaster
Installed new motor for bun toaster
Then got stuck on the phone with tech support per Brendan request and diagnosed bad main board after like an hour |
| 1404 | Brendan | 02/20/2024 | 21582 | -troubleshooted kiosk 7 printer. Think it has bad power switch, cut out power switch and crimped together. Working now
-made up and replaced cash drawer14 cord |
| 1403 | Jim | 02/20/2024 | 25383 | - sourced light ballast for lobby light
- replaced floor tile by delivery door
- looked at rolling shelf for best way to repair
- cleared floor drain at frappe machine |
| 1402 | Jim | 02/20/2024 | 02830 | - snaked and cleared sink drains |
| 1401 | Brendan | 02/20/2024 | 02830 | -troubleshooted FCB blue syrup leaking from back of machine. Expansion tank blew causing product to spray out relief valve. New tank on order
-replaced multiplex IBC probe |
| 1400 | Waylon | 02/20/2024 | 10622 | -Left grill PM Brendan taught |
| 1399 | Brendan | 02/20/2024 | 10622 | -Left grill PM |
| 1398 | Waylon | 02/19/2024 | 10622 | Installed co2 sniffer into brick ran wires half way
-installed ci2 alarm back door ran wires
-Installed co2 alarm freezer ran wires |
| 1397 | Brendan | 02/19/2024 | 04956 | -ABS not grabbing cups, cleaned lift cylinder shroud and tuneup on cup tubes |
| 1396 | Jim | 02/19/2024 | 07194 | - repaired fry light wiring
- cleared drain on frappe machine/ no water , line is connected |
| 1395 | Brendan | 02/19/2024 | 04205 | -diagnosed bun toaster. Needs new motor, on order |
| 1394 | Jim | 02/19/2024 | 00596 | - R&R washing machine with new hoses
- replaced two baseboard tiles and grouted floor area under washer
- installed pvc pipe to washer drain to prevent splash over onto floor area |
| 1393 | Brendan | 02/19/2024 | 02830 | -replaced caramel frappe bib pump but still did not solve issue. I was at a loss. Called Doug to see what he thinks, which was that sometimes stores get stuff stuck in the inlet line going to the pump. So I check that out and somehow the seal from the mix bag got sucked up and stuck in the line. Removed and working fine now. |
| 1392 | Brendan | 02/19/2024 | 10622 | -repaired platen 3, new belts
-filled out PM forms |
| 1391 | Brendan | 02/16/2024 | 17371 | -register 15 not working. Cord plugged in wrong spot… |
| 1390 | Jim | 02/16/2024 | 00596 | - installed two shelves in crew room for drinks
- Grouted top of baseboard tiles under prep sink
- installed door sweep on walk-in
- installed spray hose and nozzle at sink |
| 1389 | Brendan | 02/16/2024 | 10622 | -right grill PM, found an air leak, will order fitting |
| 1388 | Jim | 02/15/2024 | 00596 | - sourced and installed folding table brackets for crew room table
- installed four coat racks ( 2 for coats and 2foot bags and backpacks)
- installed new batteries in ladies room handicap toilet
|
| 1387 | Brendan | 02/15/2024 | 00596 | -repaired frappe machine water spinner
-repaired co2 leak at frappe
-repaired McFlurry spinner wire fell off |
| 1386 | Brendan | 02/15/2024 | 25383 | -replaced ABS ice gate
-replaced missing spray head right brewer
-replaced bulb in lobby but ended up being ballast |
| 1385 | Brendan | 02/15/2024 | 10544 | -repaired ice bin door that fell off
-bottom of ice machine leaking, hose fell out of drain
-replaced power cord pos1 |
| 1384 | Brendan | 02/14/2024 | 12272 | -replaced fry hopper power supply and dead motor
-repaired drive thru window. The installers did a bad job, they forgot to put in the screws that keep the motor attached to the bracket. Also replaced concentric nut and chain
-troubleshooted ABS ice issues. Ice chute not filling, normally you can just up the timer, but the issue is that the timer is not timing correctly, no matter how high I turn it it only times for 6 seconds. Very unusual. I am thinking it might be an MCB, if not that definitely BIB. I have those on the truck so will come back after it gets back from the shop |
| 1383 | Brendan | 02/14/2024 | 04956 | -repaired present window. Replaced centric nut, leveled door, repaired broken wire going to limit switch, adjusted close delay down
-repaired left coffee brewer, new temp probe, wiring harness, board, and calibrated
-rehung window 2 sign that fell due to wind |
| 1382 | Jim | 02/14/2024 | 00596 | - re attached the pay here and pick up here signs and crimped the hooks to prevent the signs from falling off |
| 1381 | Jim | 02/14/2024 | 07194 | - installed new small door in freezer and curtain rail also installed three door strips
- checked grease trap and grey cleanout for clogging
Found none seems like after I replaced drain lines the water flows faster out of the sinks as the old drain pipes may have been partially clogged and that is why the drain overflows now unless they control the drain flow |
| 1380 | Jim | 02/13/2024 | 07194 | - replaced ceiling tile in lobby
- installed new door sweep on delivery door
- snaked both sides of grease trap to no avail, I will open grease trap and clean it out next time I’m there |
| 1379 | Jim | 02/13/2024 | 02830 | - installed new wireless doorbell on delivery door |
| 1378 | Jim | 02/13/2024 | 21582 | - installed magnetic tape on pie merchandiser door |
| 1377 | Brendan | 02/12/2024 | 10544 | Original call for men’s room urinal inconsistent flush level. Arrived on site to urinal water being shut off completely. Turned water on to appropriate level and verified consistency by flushing a dozen times. Flush level is consistent. Snaked drain and cleaned flushometer orifices as a precaution. This location has a history of vandalism on this urinal including the theft of entire flush valves. I believe these vandals have most likely been toying around with the pressure adjustment. |
| 1376 | Waylon | 02/12/2024 | 10544 | -Stopped water leaking on back dish sink
-Helped with urinal situation per health inspector with Brendan
|
| 1375 | Jim | 02/12/2024 | 00596 | - went to clear toilet clog in men’s room, all cleared when I got there |
| 1374 | Jim | 02/12/2024 | 10622 | - replaced multiple light lenses in kitchen and stockroom
- installed correct screw in hinge of hanging nugget freezer |
| 1373 | Brendan | 02/09/2024 | 02830 | -rebuilt backflow preventer behind multiplex
-replaced exploded multiplex cooling coil
-replaced leaking multiplex water strainer
-corrected co2 system hackjob, installed new regulator. Had a bad check valve
-troubleshooted caramel frappe mix not dispensing. Replaced pinch tube and ordered new pump, pinch tube, and ice chute
-ordered ABS syrup deflector, figal fittings, IBC probe, and circ temp probe for water system repair |
| 1372 | Jim | 02/09/2024 | 00596 | - installed pay here and pick up here signs
- Grouted sink and mop sink areas
- installed five floor tiles in exterior freezer door area
- mounted (with screws) air fresheners in men’s and ladies room
- installed ceiling tile above frappe machine
- worked on straightening aluminum trim on corner at drive thru side |
| 1371 | Brendan | 02/08/2024 | 04956 | -installed ped1
-installed oven door latch
-troubleshooted 2nd window. Missing a specific bolt. On order
-troubleshooted left coffee brewer, it’s in pretty bad shape. Had everything except the board. On order
-troubleshooted lobby soda station leaking water still. Found more issues. Moved forward while unit so it hangs over the drain (it was sitting behind and ice was dripping on counter). Also found gasket on ice chute not properly installed. Yet another example of AMAZING quality control at the factory. Two nuts weren’t tightened at all, and gasket was crumpled and letting ice melt into inside of unit. Corrected issues, should be all set now |
| 1370 | Waylon | 02/08/2024 | 02830 | -Diagnosed egg cooker (then Tara decided to throw it away) |
| 1369 | Jim | 02/08/2024 | 04205 | - installed new spray nozzle and flex line at sink |
| 1368 | Waylon | 02/08/2024 | 18198 | -Replaced platen 2 front motor
-Looked into Qing oven not heating working when I left one voltage is looking weird from HV board to transformer but it was heating so we will see how long it last |
| 1367 | Jim | 02/08/2024 | 02038 | Re mounted table top in lobby
- installed new light lens in kitchen |
| 1366 | Jim | 02/08/2024 | 25383 | - replaced frappe Machine drain hose from bottom of machine to “y” connector. Old hose got bent and stopped the flow, causing leak
- repaired seat in lobby
- replaced 5 floor tiles at delivery door |
| 1365 | Brendan | 02/08/2024 | 21582 | -bix printer refresh complete
-re ER3 |
| 1364 | Brendan | 02/08/2024 | 00596 | -scrapped grill for parts |
| 1363 | Brendan | 02/07/2024 | 04956 | -bix printer refresh |
| 1362 | Jim | 02/07/2024 | 07417 | - replaced broken wall tile behind 10:1 freezer
- replaced delivery door sweep
- sourced work table cost to replace broken two door freezer next to fry vats |
| 1361 | Jim | 02/07/2024 | 12272 | - cleared men’s room toilet clog
- re routed drain lines at ABS |
| 1360 | Brendan | 02/07/2024 | 02038 | -bix printer refresh |
| 1359 | Brendan | 02/07/2024 | 07417 | -ABS having issues grabbing cups. Just needed to bend fingers back a little |
| 1358 | Jim | 02/06/2024 | 00596 | - shimmed coke tank
- installed sheet metal on men’s room door
- cleaned lobby wood look ceiling tiles
- installed new egg crate cover for ceiling vent
- installed screw to tighten door by register
Applied lithium grease to fridge drawers by grill
|
| 1357 | Brendan | 02/05/2024 | 18198 | -diagnosed left grill. Couldn’t find anything wrong with paten 1 and was working fine. Platen 2 needs new front motor. On order |
| 1356 | Brendan | 02/05/2024 | 10622 | -pulled camera footage for Venus
-replaced bunn coffee brewer tank assembly. Calibrated |
| 1355 | Jim | 02/05/2024 | 00596 | - remounted vent in crew room
- installed hook for front for extinguisher
- installed new door sweep on delivery door
- re attached wall paper in vestibule
- grouted floor by prep area |
| 1354 | Brendan | 02/05/2024 | 17371 | -replaced manifold for ABS ice maker. Put back in service, all set.
-replaced condenser fan motor in creamer. I’m like 65% sure it’s in the right direction but time will tell |
| 1353 | Jim | 02/05/2024 | 10622 | - Grouted by slop sink
- greased and cleaned rollers on two drawer fridge and the 10:1 freezer cover
- replaced light ballast in crew room |
| 1352 | Brendan | 02/02/2024 | 02038 | -replaced ped13 for damage near EMV slot. Threw away paddle as is too bent to be used. Will order new paddle |
| 1351 | Brendan | 02/02/2024 | 02830 | -troubleshooted kvs2 no power. Bad cord. Replaced, all set |
| 1350 | Brendan | 02/02/2024 | 07417 | -welding training with Nate. Welded dish sink in VERY bad shape |
| 1349 | Jim | 02/02/2024 | 17371 | - installed new light lens in stock room
- re caulked sink area
- replaced door sweep
- replaced three baseboard tiles
- spoke to Ty about sink soap shelf ( won’t fit anywhere around sink) and I will look for suitable cabinet instead |
| 1348 | Jim | 02/02/2024 | 18198 | - replaced light lens
- installed three electrical covers on lot light poles |
| 1347 | Brendan | 02/01/2024 | 02038 | -coffee brewer over brewing. Missing spray head
-handle fell off dish sink, just missing screw
-McFlurry spinner not working, replaced momentary switch |
| 1346 | Brendan | 02/01/2024 | 00596 | -replaced and reprogrammed oven controller
-troubleshooted chocolate on shake machine not working. Solenoid wasn’t activating, wiring harness is bad-temperamental only works in certain position. Have in a working position for now, but a little bump could knock it out. New wiring harness on order
-disabled coffee warmers
-tried to source parts for 10:1 freezer to auto close. Unit is 20 years old and not manufacturing parts anymore.
-troubleshooted double drawer kitchen auto closing. Was unable to see issues. Looked at sell flyer and the top drawer is SUPPOSED to be push-to-close. Stupid OAs! |
| 1345 | Jim | 02/01/2024 | 10622 | - adjusted fridge front legs, door closes on its own now
- caulked ladies room toilets (3) and men’s room urinal and toilet
- fastened cover on ice bin
- mounted mop holder and safety gear hooks
- shimmed coke tank
- men’s roof door frame secured
- 10:1 meet freezer cover closes on it own now
-replaced dining room light |
| 1344 | Jim | 01/31/2024 | 07194 | - snaked both ends of grease trap which allowed slightly better flow. I told Linda to can. Felix to come and do a thorough cleaning of the grease box.
- repaired Ice bin cover |
| 1343 | Jim | 01/31/2024 | 00596 | - removed eight cup covers and replaced with one piece of sheet steel |
| 1342 | Brendan | 01/31/2024 | 10622 | -troubleshooted bunn coffee brewer smelling like burnt wires. Found that heating element was leaking from seam, causing resistance to ground and the terminal of element to break off. The elements need to be replaced. will order a tank assembly as the bottom is very burnt up and the inside has significant lime/iron buildup
-short RGR walk thru |
| 1341 | Waylon | 01/31/2024 | 25383 | -Replaced HLZ cord
-Replaced bottom probe for hot water tank than it began reading ignition failure cleaned the flame rod throughly still read ignition failure inspected spark ignitor looked good and was creating a blue flame in the tank but still read ignition failure having Rick come out tomorrow |
| 1340 | Brendan | 01/31/2024 | 17371 | -printer refresh complete |
| 1339 | Brendan | 01/30/2024 | 18198 | -ABS not grabbing cups. Just dirty
-troubleshooted pos15. Dead Ethernet |
| 1338 | Brendan | 01/30/2024 | 21582 | -printer refresh 7 printers
-repaired HLZ, new blower
-corrected issue with kiosk7 printer
-replaced hose for filet steamer (needs a new regulator as it’s a bit drippy) |
| 1337 | Jim | 01/30/2024 | 18198 | - troubleshooted sewer smell , traced it to the drain in the slop sink maintenance closet,
Drain is not used for long periods resulting in the water in the drain drying up, this allows the sewer gasses to mitigate into the building.
I have advised building maintenance to dump water into drain every two weeks to prevent this issue. |
| 1336 | Waylon | 01/30/2024 | 00596 | -replace bad oven probe found bad oven control board
Expensive part Brendan discussing with Michael |
| 1335 | Jim | 01/30/2024 | 10622 | - Replaced washing machine and tested
- replaced castor wheels on trash cart |
| 1334 | Jim | 01/29/2024 | 10622 | - Installed new drain set on left side of sink |
| 1333 | Jim | 01/29/2024 | 18198 | - Replaced wall tile behind men’s room door
- installed new door stop on floor for men’s room door
- removed rope and reset chains on clearance bar
- reset front area milk fridge |
| 1332 | Waylon | 01/29/2024 | 18198 | Ethernet cable for pos15 and restarted |
| 1331 | Waylon | 01/29/2024 | 02038 | -Looked into GFCI switch bad turned out to be something grounding in frappe machine not my area of expertise |
| 1330 | Waylon | 01/29/2024 | 00596 | -Installed 4 new cabinet strips to old cabinets (the ones that take forever cause they are designed horribly)
-2 strips need palm pilot Tara has been notified
-Looked at oven to replace thermocouple but Brendan ordered the wrong one sadly |
| 1329 | Jim | 01/26/2024 | 04956 | - Repaired corner tiles and wall guard at delivery door
- replaced gasket on strainer at hand sink by grill
- repaired hose on left sanitizer at sink |
| 1328 | Jim | 01/26/2024 | 07194 | - snaked sink drain
- picked up butter and biscuit trays from south willow
|
| 1327 | Jim | 01/25/2024 | 00596 | - installed two black egg crate vent covers above lobby registers
- Replaced two baseboard tiles by drive thru one
- Installed screw in sink strainer
- Replaced nine floor tiles and one baseboard tile by ice coffee maker |
| 1326 | Brendan | 01/25/2024 | 17371 | -troubleshooted ice cream side, completely missing pump gasket 🤦🏻♂️
-replaced front air curtain disconnect finally
-replaced receipt printer |
| 1325 | Brendan | 01/25/2024 | 10622 | -repaired platen 1. Replaced defective contactor, relay, and board
-replaced controller on dt fridge. Watched it satisfy and is working as expected now.
-blew out clog frappe machine and cleaned out drain pan |
| 1324 | Brendan | 01/24/2024 | 12272 | -replaced dogging mech entrance door
-troubleshooted FCB no co2. Just a valve turned off.
-troubleshooted left side fry hopper. Faulty transformer outputting 150% required voltage caused door motor to die. Disconnected transformer so nothing more would die and ordered transformer (backorder) and motor
-troubleshooted ON machine fill error. Loose connection, possible a bad solenoid but problem avoided for now |
| 1323 | Brendan | 01/24/2024 | 25383 | -fixed issue with store having no internet
-replaced kiosk 9 controller |
| 1322 | Waylon | 01/24/2024 | 07194 | -Installed new board from meters for UHC closest to HLZ took a minute cause of how Brendan labeled the wires
-Replaced bad fuse in cabinet
-Replaced bad switch same cabinet
-Diagnosed bad fan
-Installed 3 UHC strips 2 middle cabinet 1 in cabinet by Hlz
-Mounted sniffer alarm ran out of Ethernet cable picking up more tmrw AM |
| 1321 | Brendan | 01/24/2024 | 07194 | -finished staging delivery monitor
-repaired orange lobby valves
-repaired Platen 3, new belts |
| 1320 | Jim | 01/24/2024 | 00596 | - installed new egg crate vent covers (8)
- repaired gap in kitchen wall behind 10:1 cabinet
- replaced corner bead at drive thru one |
| 1319 | Jim | 01/24/2024 | 07194 | Replaced stained ceiling tile in lobby
- Grouted by ice machine and cage |
| 1318 | Brendan | 01/23/2024 | 18198 | -shake machine training with Ashley and Steeley |
| 1317 | Waylon | 01/23/2024 | 07194 | -replaced filet steamer OEP and egg cooker OEP
-installed 2 co2 alarms and central unit |
| 1316 | Brendan | 01/23/2024 | 07194 | -delivery monitor install |
| 1315 | Jim | 01/23/2024 | 07194 | -tile replacement and grouting in multiple locations
- Sanded wall end at crew room entrance |
| 1314 | Jim | 01/22/2024 | 07194 | - Grouted by coke syrup tank and behind multiplex
- replaced one baseboard and 5 floor tiles |
| 1313 | Jim | 01/22/2024 | 25383 | - tightened spud nut on ladies room toilet
- tightened men’s room faucet
- applied epoxy to grill side drain |
| 1312 | Waylon | 01/21/2024 | 17371 | Water system upgrade -Installing manifold and running lines to make everything 1/2 inch instead of 1/4 |
| 1311 | Waylon | 01/23/2024 | 18198 | -Platen 2 squishing quarters
~Checked motor and belts then scraped carbon build up and cleaned Teflon
~ gapped with go / no go tool and cooked perfectly fine
-Helped Katy clean frappe machine |
| 1310 | Brendan | 01/23/2024 | 02830 | -removed piston rod that was stuck in shake machine. Short shake machine training tips and tricks session with holly |
| 1309 | Brendan | 01/22/2024 | 10622 | -troubleshooted platen 1, found multiple issues. Bad contractor and bad board, on order
-retroubleshooted dt fridge. Misdiagnosed first time. Compressors constantly running even past setpoint. Suspected bad controller. Confined relay was sticking by tapping it. New controller on order. |
| 1308 | Brendan | 01/22/2024 | 00596 | -fought with shake machine to get pump shaft out. If they had been taking it apart and cleaning/lubing it it wouldn’t have taken so long. Eventually got it. Took so long that it freezer locked though. In a heat mode now but should be all set. I smell like shake mix now 😷
-looked at muffin toaster not working. Just a tripped breaker |
| 1307 | Jim | 01/22/2024 | 25383 | - Tightened spud nut on ladies room handicap toilet
- Tightened men’s room faucet
- applied epoxy to grill side grease drain bin |
| 1305 | Brendan | 01/21/2024 | 17371 | -water system upgrade with Waylon |
| 1306 | Waylon | 01/21/2024 | 17371 | -water system upgrade with Brendan |
| 1304 | Brendan | 01/21/2024 | 18198 | -repaired landing zone, replaced air heater relay |
| 1303 | Brendan | 01/21/2024 | 10622 | -replaced main board right grill right platen
-replaced temp probe front dt fridge
-replaced dogging mech entrance door
-investigated leak from melitta. Coming from fitting going to boiler, store to call melitta |
| 1302 | Brendan | 01/19/2024 | 12272 | -repaired push bar by bathrooms |
| 1301 | Brendan | 01/19/2024 | 04205 | -installed new battery backup
-stole old grill parts |
| 1300 | Brendan | 01/19/2024 | 07194 | -troubleshooted platen 3 home switch not seen. Two belts snapped. Will pick some up over weekend
-troubleshooted and repaired handicapped buttons
-replaced coke tank jump port causing co2 leak
-replaced present bump bar |
| 1299 | Brendan | 01/19/2024 | 02830 | -repaired co2 leak, replaced coke tank 1 pressure relief
-investigated water by multiplex. Has sprung two leaks. Parts on order |
| 1298 | Jim | 01/19/2024 | 07194 | - Grouted in front of grills and miscellaneous areas
- installed new trim piece above cage opening
- Grouted floor area at sink
- fixed beverage unit doors at drive thru two
- Installed new door sweep on walk- in |
| 1297 | Jim | 01/18/2024 | 07194 | - Grouted in front area |
| 1296 | Jim | 01/18/2024 | 10544 | -Picked up and installed fry station mirror |
| 1295 | Jim | 01/18/2024 | 07194 | - Grouted in front of fryers on floor, and by delivery door
- spray foamed abandoned conduits in floor by food prep area
- |
| 1294 | Jim | 01/17/2024 | 07194 | - Grouted floor areas at cage, in front of walk-in, and misc single tiles
- filled holes in FRP at new water filter, and lobby maintenance room door
- replaced corner trim at cage, first drive thru entrance, and second drive thru rail |
| 1293 | Jim | 01/16/2024 | 07194 | - installed floor tiles by the cage
-installed floor tiles in front of walk-in |
| 1292 | Jim | 01/16/2024 | 00596 | - cleared lobby drink station tray drain and under cabinet drain and sump |
| 1291 | Jim | 01/15/2024 | 07194 | - Grouted wall behind counter and floor tiles that were replaced Friday
- Grouted floor area by shake machine area
- removed and set up base at cage area
- snaked sink drain and cleared out clog that caused sink drain to overflow when emptying sink basins |
| 1290 | Jim | 01/15/2024 | 10622 | - Grouted floor tiles under ABS system
- checked ladies room toilet flushes fine, also snaked toilet for 15 feet, found no obstructions. |
| 1289 | Jim | 01/12/2024 | 07194 | - removed and replaced multiple floor tiles |
| 1288 | Brendan | 01/11/2024 | 07194 | -reattached condenser cover to ABS
-put bolt in bun toaster
-quick rgr walk thru |
| 1287 | Jim | 01/11/2024 | 07194 | - rebuilt drain system on sink
( one drain kept leaking so will remove Tomorrow and repair sink opening) |
| 1286 | Jim | 01/11/2024 | 18198 | - Grouted lobby wall tiles and sink floor area
- re installed ramp in walk- in/ freezer |
| 1285 | Waylon | 01/10/2024 | 18198 | -Installed new bakery monitor
-Installed Hlz computer side 1 (arrived fault?)
-diagnosed Hlz side 2 bad air heater relay
-Installed new oep yellow next to cabinet
-Mounted mcflurry mixer
-Finished ice machine pm
|
| 1284 | Brendan | 01/11/2024 | 25383 | -replaced mens room dryer board/sensor
-diagnosed hlz, needs new receptacle and cord, on order |
| 1283 | Jim | 01/10/2024 | 07194 | - re attached top plate at kiosk to ceiling
- temporarily installed top covers on toaster |
| 1282 | Jim | 01/10/2024 | 18198 | - replaced three dividers on kitchen wall FRP
-remounted wall tiles in lobby area
|
| 1281 | Brendan | 01/11/2024 | 07417 | -replaced ABS umbilical and tuneup |
| 1280 | Brendan | 01/10/2024 | 18198 | -installed new monitor to mirror UHC epr.
-recrimped side 2 lunch bump bar
-reimaged pos 1 with new SSD |
| 1279 | Brendan | 01/10/2024 | 21582 | -3 fry sockets not working. Replaced one burnt up one |
| 1278 | Brendan | 01/10/2024 | 04205 | -no water at frappe and mccafe. Frappe was unplugged, mccafe was off due to blown line. Repaired lines
-coffee brewer dripping from overflow. Replaced probes and fill solenoid
-troubleshooted power issues in office. PSU bad, new one on order
-found that ABS cup tube was missing and not sensing empty cups. Repaired cup tube that was missing keyhole nuts and cup finger. Diagnosed grabber sensor, has bad umbilical. On order |
| 1277 | Brendan | 01/09/2024 | 18198 | -NOW SHOWING in Epsom: Return of the Worms
-installed new camera on new bracket on roof, finished running coax to office. 1st window working, 2nd window needs splitter
-ordered new drain valve for soap sink
-troubleshooted drive thru fridge freezing product. Needs new probe, on order
|
| 1276 | Jim | 01/09/2024 | 07194 | - repaired delivery walkway ( concrete damaged)
- measured freezer door for replacement
- re installed top cover with new toggle bolt |
| 1275 | Waylon | 01/09/2024 | 10622 | -worms…
-Vacuumed under abs set up dryer blower
-Installed one tile
-Unclogged women’s bathroom toilet
-Took measurements for dish sink left drain
-Installed new pvc holder for abs drain pipe |
| 1274 | Jim | 01/09/2024 | 18198 | - fastened box to floor in front of shake machine
- sourced and replaced multiple ceiling tiles in lobby area |
| 1273 | Brendan | 01/08/2024 | 18198 | -replaced dt lane camera and reran wire from roof. Removed old black and white multiplexer and moved to channel 0 |
| 1272 | Brendan | 01/08/2024 | 00596 | -troubleshooted filet steamer. Just wasn’t plugged into water… also replaced oring because was a bit dribbly |
| 1271 | Waylon | 01/08/2024 | 18198 | -Replaced one strip in UHC bottom row newer cabinets harder to work on since the ribbon cable is so small you need like baby hands to reach it
-Cut off old caulk on grill grease traps then scrubbed with degreaser and than put high temp caulking on it
-Replaced fish steamer regulator
-look into Hlz but wasn’t giving me an error code after turning on and off after half an hour so going to check back in the morning
-briefed by Brendan on NRBS visits
-Cut a 14x14 hole in box cover for pipes upfront with angle grinder waiting on jim to screw into floor |
| 1270 | Jim | 01/08/2024 | 12272 | - installed new outlet for hood misting system
- R&R rear lobby door crash bar to adjust for smoother operation |
| 1269 | Brendan | 01/08/2024 | 07417 | -sodas flat; replaced both circ motor/pumps with mag drive upgrade. Replaced 5 fittings |
| 1268 | Brendan | 01/05/2024 | 10622 | -replaced pos13 due to hardware failure
-sweetener upgrade
-installed parts in ice machine. Takes a really long time to harvest, will call Rick on Monday
-noticed large puddle underneath mcafe ice bin. Found clog in drain, blew out nice and clean |
| 1267 | Jim | 01/05/2024 | 18198 | - rebuiltceiling grid and panels in IT closet
- fastened floor cleaned out cover by delivery door |
| 1266 | Jim | 01/05/2024 | 10544 | - clearedurinal clog in men’s room
- replaced O-ring on faucet and added thread tape to the T on sink faucet |
| 1265 | Brendan | 01/04/2024 | 07194 | -replaced parts on 10:1 freezer lid
-troubleshooted lobby valves. parts on order |
| 1264 | Jim | 01/04/2024 | 00596 | - cleared urinal clog in men’s room
- re tightened cold water handle on hand sink |
| 1263 | Jim | 01/04/2024 | 21582 | - picked up and installed new panel for inside freezer door |
| 1262 | Brendan | 01/04/2024 | 12272 | -installed auger part, ABS is all set to fill with ice now |
| 1261 | Waylon | 01/04/2024 | 18198 | -Replaced 3 UHC strips
-1 UHC umbilical cord
-Had to fix slots in UHC that were to far from heat plate causing gapping
-Bolt down coke tank
-Bolt down ramp in walk-in
-Strip old UHC cabinet and remove from store
-Brought parts from UHC and shake machine to office including a mirror and door for a fridge from van |
| 1260 | Waylon | 01/03/2024 | 17371 | -Installed new fry socket
-Installed new water ramp for ice machine without it wouldn’t make ice and registered bin is full was a bigger process to remove than I thought had to remove a lot of caulking to get to and then reinstall everything |
| 1259 | Brendan | 01/04/2024 | 07417 | -troubleshooted flat soda. Temping way too high. Both circ pumps/motors are bad. On order |
| 1257 | Jim | 01/04/2024 | 02830 | - hand started rooftop exhaust motor for grill
- replaced leaking flex hose and spray head on sink |
| 1256 | Jim | 01/03/2024 | 12272 | - adjusted cover on dogging Device, works fine now |
| 1255 | Jim | 01/03/2024 | 21582 | - mixed and poured concrete for loose railing
2 of three done , needs to harden overnight to finish |
| 1254 | Jim | 01/03/2024 | 10622 | - installed soffit panel and soffit light above delivery door |
| 1253 | Jim | 01/03/2024 | 21582 | - started work on loose railing
|
| 1252 | Brendan | 01/03/2024 | 10622 | -replaced door dogging mechanism
-replaced door lock cylinder and had keys cut
-replaced brew solenoid Curtis brewer
-corrected dt lane 1 camera not showing
-tried replacing dt merge camera but alas it needs a new run of cable, ran the cable from outside, brackets on order for new camera
-troubleshooted ped13. Found cord plugged into it which shouldn’t have been. Also replace cord to be safe
-worked with Jim to re hang metal fascia with lights |
| 1251 | Waylon | 01/03/2024 | 18198 | -Reset and unplugged window 1 monitor no camera display
-Installed the rest of the co2 alarm
* one alarm by ladder outside office door
* sniffer alarm to the right of coke tank and left of backup co2
* central alarm above printer in office
Ran cords for all and tested
-Taped frayed wire per drew/Ty request |
| 1250 | Brendan | 01/02/2024 | 21582 | -replaced ABS lift cylinder
-ABS tuneup; replaced 1 cup finger, adjusted cup fingers, calibrated index sensor, small cup tube very cracked-on order
-troubleshooted both front counter card readers. Replaced one, other was missing berg retainer and tied up cords so they wouldn’t come loose again
-replaced relay in HLZ, made other issues apparent. Parts ordered |
| 1249 | Brendan | 01/02/2024 | 00596 | -troubleshooted oven burning items. Probe was way off. Calibrated, should solve
-reaffixed HLZ cover
-checked out and ordered parts for grill vent hood |
| 1248 | Brendan | 01/02/2024 | 04205 | -troubleshooted flat soda. Two issues, refrigeration switch was off as well as pump/motor not performing well. After a myriad of issues and leaks, repair finally complete
-troubleshooted CIP no power. Wire in unit broke. Repaired, also replaced leaky sanitize pressure connector and line
-noticed co2 tank frozen over. This was due to store having the yogurt in the wrong spot @ BIM
-kids kept getting fingers crushed in playplace double doors. Removed both doors entirely |
| 1247 | Jim | 01/02/2024 | 21582 | - temporarily tightened outside hand railing till final repair can be made |
| 1246 | Jim | 01/02/2024 | 18198 | - Grouted lobby wall tile that had cracked grout lines
— replaced ceiling tiles in lobby area |
| 1245 | Jim | 01/02/2024 | 07417 | - installed door stop on men’s room toilet stall door
- installed top RH hinge for fry station cabinet |
| 1244 | Brendan | 12/31/2023 | 12272 | Major ABS repairs pt 1.
-Replaced ice bin
-replaced agitator motor mounting bracket
-replaced agitator motor
-replaced ice chute assembly with gasket
-installed new ice maker adapter
3 bits of bad news though:
1. When I took off the conveyor, I noticed the drip tray had many cracks leading to even more leaks, as well as the drain fitting cracked. On order
2. The retaining ring holding the ice auger on rusted off during disassembly, on order.
3. Staging table also has a cracked drain fitting, will order from Franke.
This puts the tally to $4,500 on parts. ABS is working normal now, asked them not to fill it with ice for now. All the repairs should be done by the end of the week. There aren’t many more issues I could possibly run into so should be smooth sailing after that |
| 1243 | Brendan | 12/29/2023 | 04956 | -switched kiosk network port and troubleshooted time service as per Capgemini |
| 1242 | Jim | 12/29/2023 | 00596 | - tried to snake drain under ice machine and the snake went to about ten feet, but it’s not strong enough to break through
May need septic company to us professional snake
I also poured 16 oz of drain cleaner in the drain |
| 1241 | Jim | 12/29/2023 | 10544 | - Grouted floor area by sink
- tried to fasten walk in floor, once drill went through diamond plate it hit nothing
- removed fry station mirror and dropped off at Queen City glass
- Installed new trap on hand sink up front |
| 1240 | Jim | 12/29/2023 | 04205 | - cleared men’s room toilet |
| 1239 | Brendan | 12/29/2023 | 21582 | -replaced 3 receipt printers in grill
-replaced switch on fry station
-arrived to store out of Co2. Was told there is a leak (first im hearing of this). Was told it’s the co2 tank and that air gas was called. The tank was not leaking. The ABS cylinder the cause of significant leak. I just ran out, new part on order |
| 1238 | Brendan | 12/28/2023 | 04956 | -called HPE again for the WiFi and WBU issues
-troubleshooted CIP not purging co2. After much troubleshooting, I discovered it was plumbed in incorrectly by J&J during the renovation! Corrected and verified operation.
-surveyed and ordered equipment for outdoor cameras and dt cameras to be installed in spring |
| 1237 | Brendan | 12/28/2023 | 25383 | -replaced egg cooker receptacle
-replaced ped6 |
| 1236 | Brendan | 12/28/2023 | 04205 | -troubleshooted flat lobby soda, bad motor. On order.
-troubleshooted co2 leak, found in frappe machine. Unused valves need to be turned off.
-troubleshooted left side fry hopper, door motor. Replaced.
-replaced backup co2 regulator |
| 1235 | Jim | 12/28/2023 | 07417 | - replaced door sweep
- ice machine cover, installed new pins
- replaced light lense above grills |
| 1234 | Jim | 12/28/2023 | 12272 | - replaced bulbs in two can lights, one in lobby, one in men’s room
- ballast at Drive thru one all set
- ordered exterior siding for drive thru damage |
| 1233 | Brendan | 12/28/2023 | 07194 | -bix transition completed
-USB and USB switch box completed
-installed EPR printer |
| 1232 | Brendan | 12/27/2023 | 07417 | -replaced rear door closer per MB
-stole fry station glass for reglazing |
| 1231 | Brendan | 12/27/2023 | 25383 | -replaced egg cooker OEP. However, there is something jammed in the outlet causing it not to go in fully, which is the cause of the melted OEP. on order.
-QMP follow-up; replaced surge tank |
| 1230 | Jim | 12/27/2023 | 00596 | - replaced office thermostat’s batteries and educated manager on how to remove and replace
- replaced ladies room handicap TP holder
- checked under ice machine for water leak, found no active leaks, and drain is clear
- installed new paper towel holder by office |
| 1229 | Brendan | 12/27/2023 | 07194 | -disabled decanter warmers
-troubleshooted issue with back door Detex. Was wiring issue. All repaired.
-replaced dt runner bump bars
-QMP follow-up; replace CIP purge button
-tried to find parts for meat freezer slider, had to email Franke
-emailed Bally to order new freezer delivery hatch |
| 1228 | Brendan | 12/27/2023 | 18198 | -looked at frappe leak-plugged in and turned water on. No trouble found, might just not have been pushed on all the way.
-looked at card reader giving issues. No trouble found, must’ve been customers with bad cards |
| 1227 | Jim | 12/27/2023 | 10622 | - plunged and cleared ladies room toilet clog
- plunged and cleared floor drain under prep sink drains right away now |
| 1226 | Jim | 12/27/2023 | 17371 | - re tightened walk- in door closer
- removed hand sink strainer and cleaned putty off ( no putty) and installed new rubber gasket
- re set fence post and installed four rails
- repositioned toaster cord and tightened lock collar
- installed new light lense |
| 1225 | Jim | 12/26/2023 | 18198 | - Grouted baseboard tiles behind movable racks and replaced two tiles
- Grouted floor area around ice maker
- Grouted floor at sink area
|
| 1224 | Brendan | 12/26/2023 | 04205 | -stripped left grill for parts |
| 1223 | Waylon | 12/22/2023 | 04956 | Qing oven switch |
| 1222 | Waylon | 12/22/2023 | 12272 | -Started to grout under abs it needs to wait till the bug problems are treated by eco lab
- installed 2 new cameras in the grill took a while since the ceiling is very hard to get into and is a disaster
-was gonna do drive thru light ballast but they have had full screens for hours now and I think it would be better to do one morning |
| 1221 | Brendan | 12/22/2023 | 07194 | -bix printer refresh |
| 1220 | Jim | 12/22/2023 | 18198 | -Replaced two wheels on 10:1 freezer
- installed screw on fry loader guide
- Drilled and Mounted pin plates on corral gates |
| 1219 | Brendan | 12/22/2023 | 04956 | -installed new hot water faucet
-QMP follow-up, replaced lobby circ motor. Soda now temping properly |
| 1218 | Brendan | 12/21/2023 | 07417 | -replaced frappe motor finally and did full PM. Once product comes off the truck store is to do weekly cleaning and calibrate before placing back into service |
| 1217 | Jim | 12/21/2023 | 18198 | - Removed damaged FRP and drywall at Drive thru one
And rebuilt wall and installed new FRP |
| 1216 | Brendan | 12/21/2023 | 07194 | -worked with Waylon to mount new vzn filter system
-replaced fry monitor
-corrected issue with orb not displaying
-took board from UHC to send to Meyer’s |
| 1215 | Waylon | 12/21/2023 | 07194 | -Removed garden hose holder
-Helped Brendan instal new filter system
-Moved bug light from the left side of oil tanks to the right overhanging maintenance closet |
| 1214 | Waylon | 12/21/2023 | 18198 | -Caulked the top half of sink between metal and frp taped off and edged
-cleaned old sitting water under the sink that no one was cleaning up and double checked areas for any leakage
-Caulked around hand nozzle turn on / off valve because it’s stripped so water could leak down the back and be a problem |
| 1213 | Waylon | 12/20/2023 | 18198 | -Helped scrap shake machine for parts
-Installed last drain valve for dish sink had to replumb a part of that cause it went from 1.5 inch on the old to 2 inch on the new which gave only 3 inch of space between that and the air gap so pipes had to be adjusted
-Caulked between metal metal on the back sink covered with plastic and taped off to sit over night |
| 1212 | Waylon | 12/19/2023 | 18198 | -Installed two new sink drains (including levers and clean outs
-Redid all the pvc behind it
-Hung co2 alarm |
| 1211 | Brendan | 12/20/2023 | 18198 | -repaired ABS; cylinder shroud needed some washers
-scrapped old shake machine for parts |
| 1210 | Jim | 12/20/2023 | 18198 | - Replaced 6 floor tiles at delivery door and grouted
- R& R 5 baseboard tiles and grouted
- replaced two ceiling light lenses |
| 1209 | Brendan | 12/20/2023 | 12272 | -went to install motor and bracket. However major problem had become apparent since the ice melted. Massive hole was scraped into hopper, adding another cause to the leaks. Will need to have Rick come out to remove ice machine. Will need to order hopper and hardware.
-mcafe fridge not running; breaker tripped |
| 1208 | Brendan | 12/19/2023 | 10622 | -replaced OJ machine with new replacement. OJ machine used old coffee line off of RO which is incorrect. I replumbed with insulated line teeing off of dilute line, which is chilled |
| 1207 | Brendan | 12/19/2023 | 18198 | -replaced lift cylinder and fittings causing co2 leak
-replaced abs regulator gauge
-ABS tuneup, calibrated sensors, replaced grip pads, replaced/repaired cup fingers
-replaced coke dispense line which had a leak
-Fanta not working @ abs; just needed calibration |
| 1206 | Jim | 12/19/2023 | 02830 | - replaced water lines to washing machine
- installed new wall bracket for sink sprayer
- repaired hot water connection at slop sink and covered wall with plywood and FRP |
| 1205 | Brendan | 12/18/2023 | 02830 | -repaired coffee brewer, new board and probe
-corrected music not playing, was plugged in wrong
-replaced motor and chain for window 2 |
| 1204 | Waylon | 12/18/2023 | 21582 | -Grill bump bar cable and swapped out bump bars
-Replaced UHC strip on cabinet
-Replaced light ballast in office
-Looking into FDA code on cabinet |
| 1203 | Jim | 12/18/2023 | 18198 | - installed multiple corner bead near sink and first drive thru areas
- installed ice bucket hanger next the ice machine
|
| 1202 | Brendan | 12/18/2023 | 21582 | -replaced muffin toaster top elements and calibrated
-corrected eProduction projections
-troubleshooted HLZ, needs new relay and fuses. On order |
| 1201 | Waylon | 12/18/2023 | 00596 | -Looked at muffin toaster smoking seemed to only be the insulation burned ran and test fine
-Outback sink leaking was because was clogged up with food and water was slowly dripping out of pipes they keep putting grease and food down a tiny drain
-Replaced fry socket in fry station was burnt beyond recognition
- looked at cod1 being super loud sounded like a normal level |
| 1200 | Brendan | 12/18/2023 | 12272 | -replace ped13, dead emv reader
-troubleshooted ABS leak. I found the culprit to be rusted brackets for auger causing motor to fall out and let ice accumulate inside machine. Parts on order
-remounted CIP panel |
| 1199 | Jim | 12/18/2023 | 07194 | - completed door lock set install for rear door, gave keys to Linda |
| 1198 | Jim | 12/18/2023 | 04205 | - went to open stuck freezer door, due to ice build up at threshold
- swapped CO2 tank hookup to full tank
|
| 1197 | Jim | 12/18/2023 | 07194 | - working on rear door lock set install
|
| 1196 | Jim | 12/15/2023 | 07194 | - troubleshoot fryer vent motor runs intermittently told store to call Rick per Brendan
- cut and installed two ceiling tiles above tea brewer
- replaced roof switch for fry vat vent
|
| 1195 | Brendan | 12/15/2023 | 02038 | -replumbed coffee brewer waterlines as they were leaking
-installed and calibrated new coffee brewer
-installed new bix in window 1 |
| 1194 | Brendan | 12/15/2023 | 10544 | -troubleshooted coffee brewer leaking. Replaced leaky fill solenoid and crusty level probe |
| 1193 | Brendan | 12/15/2023 | 25383 | -checked grease trap, looks like someone already fixed.
-fixed kiosk 7 not booting
-ordered parts for mens room dryer
-ped6 missing file error message. Rescue in progress, will verify to make sure later |
| 1192 | Brendan | 12/15/2023 | 04205 | -front DT no power, breaker was off. Can’t even blame them because th breaker was labeled as a fridge🙃 |
| 1191 | Jim | 12/14/2023 | 07194 | - Coated entry to crew room with drywall mud
- drilled and installed 4 bolts in walk-in threshold
- sourced and installed light bulbs in FC and kitchen fridges kitchen light switches need to be replaced |
| 1190 | Jim | 12/14/2023 | 04205 | - Grouted floor at nugget fryer and grill
- Tightened spud nut on ladies room handicap toilet |
| 1189 | Waylon | 12/13/2023 | 12272 | -Checked for crawlers found my concrete hardened and that I need to redo some plumbing tmrw |
| 1188 | Waylon | 12/13/2023 | 12272 | Moved one co2 alarm and redid a lot of wires to neaten
Dropped in two ceiling tiles above abs
Started on coffee brewer but got pulled into multiple directions so Brendan finished
Helped with men’s door closer
Removed RO tank from building
|
| 1187 | Brendan | 12/13/2023 | 04205 | -replaced bump bar
-had detex keys made
-repaired mens room door closer
-replaced tanks on RO as well as membranes, defective check valve and pump
-coffee brewer further diagnosis. Ordered new board
-replaced walk-in fridge door gasket |
| 1186 | Jim | 12/13/2023 | 07194 | - Cleaned out old and replaced with new caulking behind sink
- replaced right hand sink drain assembly, gasket and PVC piping |
| 1185 | Jim | 12/13/2023 | 04205 | - installed one baseboard tile and one floor tile
- had concrete removed from corral
- R&R men’s room mirror |
| 1184 | Waylon | 12/12/2023 | 12272 | 🪱 + 🪳 act 4 |
| 1183 | Brendan | 12/12/2023 | 12272 | -Worms: Episode 4 - feat. The Roach Family
-replaced dead emergency battery and three lights |
| 1182 | Jim | 12/12/2023 | 07194 | - Refastened corner trim at crew room entrance
- removed and replaced three wall tiles at front counter wall
- repaired hole in wall at crew room entrance |
| 1181 | Jim | 12/12/2023 | 02830 | - Steam cleaned the slat wall around shake machine ( health inspector required)
|
| 1180 | Brendan | 12/11/2023 | 18198 | -further co2 leak investigation. Checked omega, not it. Was able to find it on the ABS. lift cylinder bypassing. Noticed bad gauge on regulator. On order
-replaced side 1 lunch monitor
-attempted to repair melitta door. Unfortunately switch completely missing, store to call melitta
-finally repaired vzn water filter
-ordered bump bars
-ordered co2 alarms
-ordered 3 comp sink drain stops |
| 1179 | Waylon | 12/11/2023 | 04205 | -Co2 alarm full installation took forever because the whole ceiling is Sheetrock and running wires you can’t see is quite difficult
-Replaced Fanta pump
-Helped promote to primary power |
| 1178 | Brendan | 12/11/2023 | 04205 | -replaced bun steamer regulator
-replaced hlz plate relay
-finished repairing and water tested lobby ice dispenser
-replaced RO bypass regulator. Solved one problem but discovered more. One inline check valve defective, membranes blew out, and no orifices. On order |
| 1177 | Jim | 12/11/2023 | 04205 | - cut steel in corral to be picked up by scrap company |
| 1175 | Jim | 12/11/2023 | 07194 | - installed new glass door and lock for toy display case |
| 1174 | Jim | 12/11/2023 | 04205 | - Installed new weather strip on trash door
- Installed mop holder at slop sink
- Filled holes around building
- replaced men’s room mirror
- Re mounted moulding and wires at rear of stock room |
| 1173 | Waylon | 12/11/2023 | 18198 | Resecured walk in ramp left corner was peeling up (also missing screw) |
| 1172 | Jim | 12/08/2023 | 10622 | - Cleared ladies room toilet and men’s room urinal |
| 1171 | Jim | 12/08/2023 | 18198 | - patched pothole in route 125 entry
- replaced two wheels on toaster cart
Prepped corner bead for installation
|
| 1170 | Brendan | 12/08/2023 | 04205 | -installed exit sign
-repaired two lobby soda valves, rocks in flow control
-installed gasket on SSBS ice dispenser. Had to caulk because bin is cracked. Hopefully it is enough to solve the issue
-diagnosed RO system. Faulty bypass regulator. On order |
| 1169 | Brendan | 12/08/2023 | 12272 | -replaced filters on RO system, solved one problem but then found out that flow controls are bad. On order
-replaced a few leaking fittings from RO |
| 1168 | Brendan | 12/07/2023 | 04205 | -replaced many dead exit signs
-replaced emergency light battery backup
-rekeyed play place detex
-discovered two more exit signs in need of replacement, above play place exit and trash door
-discovered and diagnosed coffee brewer giving two blink error, replaced probe and fill valve
-discovered and diagnosed HLZ giving "Hi" error. Heat plate SSR stuck closed, on order
- replaced can light fixture in lobby
- diagnosed both camera monitors. power port on the upfront one is finicky, needs replacement. First window monitor has a finicky RCA port, needs replacement. on order
-followed up with lobby ice dispenser leak. leak was growing in fact. Now that the ice had melted I could access big clog in the drain. cleared it out, will replace ice chute gasket tomorrow and hope that resolves |
| 1167 | Waylon | 12/07/2023 | 04205 | Installed 1 lobby exit sign
Installed outback emergency light battery
Replaced 3 ceiling tiles |
| 1166 | Brendan | 12/06/2023 | 04956 | -Reimaged kiosk 6 per corporate |
| 1165 | Waylon | 12/06/2023 | 12272 | -Changed washing machine outlet (Live) (Old outlet was burnt out causing the washing machine plug to be loose and pop out replaced with a tamper resistant switch |
| 1164 | Jim | 12/07/2023 | 02038 | - tested water temp on man’s room (105) and ladies room (117) all set |
| 1163 | Jim | 12/07/2023 | 02830 | - replaced remote batteries on handicap buttons and paired them |
| 1162 | Jim | 12/07/2023 | 02038 | - reset men’s room toilet ( replaced wax ring and closet bolts) |
| 1161 | Jim | 12/07/2023 | 10544 | - replaced flush control valve on men’s room urinal
- straightened top door hinge on men’s room door
- mounted employee must wash hands sign on men’s room door |
| 1160 | Jim | 12/06/2023 | 10622 | - cleared men’s room urinal and ladies room small toilet also removed door stop extension as some one broke the frame again.
I will tack weld it later |
| 1159 | Jim | 12/06/2023 | 07194 | - Picked up glass display door from Queen City
, at the store they did not have the lock, when I sourced the lock it was slightly to big. So I called Queen City and brought it back so they can sand the opening and fit the lock.
It will be ready tomorrow |
| 1158 | Jim | 12/06/2023 | 04205 | Grouted floor area at nugget fryer and grill |
| 1157 | Waylon | 12/06/2023 | 04205 | -Replaced 18 lobby ceiling tiles
-Fixed filet steamer board waiting on water regulator to come in
-Fixed lobby light ballast (was a very tight space to work in)
-Installed new plexi glass for back door and caulked |
| 1152 | Jim | 12/05/2023 | 04205 | - replaced multiple floor tiles
- Grouted under sink
- cleared men’s room toilet clog |
| 1156 | Brendan | 12/03/2023 | 04205 | -RGR walk through
-ordered three exit signs and a battery
-ordered parts for filet steamer and muffin toaster
-troubleshooted lobby leak under SSBS. needs new gasket on ice chute, on order
-replaced lobby shade chain
-replaced power strip with three outlet adapter
-installed side two receipt printers
-troubleshooted dt lane monitors, bad connector and was turned off
-repaired detex and reinstalled |
| 1155 | Waylon | 12/05/2023 | 04205 | -Replaced 2 Ballast in kitchen lights
-Reinstalled 10 light bulbs 2 kitchen 1 outback near walk-in door
-Went to Kamco to pick up two cases of ceiling tiles one for second st one for Raymond
-Picked up materials for back door small window
- went over list with brendan
- installed new lobby shade chain with brendan |
| 1154 | Jim | 12/05/2023 | 04205 | Grouted floor tiles |
| 1153 | Jim | 12/05/2023 | 12272 | - replaced triple 40 Amp breaker for HVAC. Panel AP-2 breakers # 27,29,31 |
| 1151 | Jim | 12/04/2023 | 04205 | - Re Tightened ladies room small toilet feed nut , no leaks
- removed and replaced six floor tiles by nugget fryer
- Coated floor sill by bump out window in lobby |
| 1150 | Jim | 12/04/2023 | 04205 | - Re Tightened ladies room small toilet feed nut , no leaks
- removed and replaced six floor tiles by nugget fryer
- Coated floor sill by bump out window in lobby |
| 1146 | Brendan | 12/04/2023 | 04956 | -replaced door latch OJ machine |
| 1145 | Waylon | 12/04/2023 | 04205 | -Replaced one UHC strip in cabinet closest to HLZ enter button was broke couldn’t switch to lunch
-Replaced UHC strip second cabinet all the buttons were broke couldn’t use at all
-Replaced UHC cabinet switch closest to HLZ (TWICE) one switch came broken stupid cheap switches 😡 |
| 1144 | Jim | 12/04/2023 | 04205 | - Re Tightened ladies room small toilet feed nut , no leaks
- removed and replaced six floor tiles by nugget fryer
- Coated floor sill by bump out window in lobby |
| 1143 | Brendan | 12/04/2023 | 00596 | -removed stuck key from detex. Noticed that the magnet has snapped as well, will order for next time and replace battery as well
-repaired walk-in freezer door hinge, had to retap holes a size bigger
-troubleshooted ABS. Index sensor not working, wire broke off. Repaired |
| 1142 | Waylon | 12/04/2023 | 07194 | -Replaced fry station switch (was causing lights to go in an out randomly)
-Reprogrammed UHC cabinet the board is bad and deletes everything programmed, but their pending a ecosure visit |
| 1141 | Brendan | 12/04/2023 | 02038 | -troubleshooted coffee brewer. Needs parts but don’t make anymore. New brewer on order
-attempted to unclog prep fridge drain line. Tried my best we will see how it does. I’m not too convinced |
| 1140 | Jim | 12/04/2023 | 12272 | - ordered triple 40 amp breaker for HVAC system will be in Tuesday afternoon
- fixed fry bulb socket |
| 1139 | Brendan | 12/01/2023 | 02830 | - installed battery in vestibule handicap button
-worked on opening above slop sink due to faucet leaking |
| 1138 | Jim | 12/01/2023 | 04205 | - Picked up bulbs for walk in lite and installed with safety sleeves
|
| 1137 | Waylon | 12/01/2023 | 10622 | -Window 1 card reader randomly shut off
* I just swapped outlet works perfectly fine had a loose outlet…. (Potentially could be a bad cord but only gonna replace if problem persist which it hasn’t in 20 mins so…) |
| 1136 | Waylon | 12/01/2023 | 07194 | -Replaced ice gate valve that was stripped abs is all running perfectly (Tested 4 cups through it) |
| 1135 | Waylon | 11/30/2023 | 07194 | -Diagnosed abs ice Shute - stripped badly |
| 1134 | Waylon | 11/30/2023 | 04205 | -Replaced two walk-in light ballast
*Had two very old ones were beginning to melt and smell horrid
-A crew member dropped one of the light bulbs so had to go to an electric warehouse ordered 4 for tmrw Jim will get
- Installed side 2 monitor and aided Brendan remotely |
| 1133 | Jim | 11/30/2023 | 07194 | - Prepped and welded two railing rods on drive thru side railing
|
| 1132 | Jim | 11/30/2023 | 21582 | - replaced ceiling tile next to sink
- cut and installed baseboard tiles by frappe machine |
| 1131 | Waylon | 11/29/2023 | 07417 | -Resecured drain under gray ice bin (added mounting bracket clamp) |
| 1130 | Waylon | 11/29/2023 | 04956 | -Fixed fry hopper terminal block was shorted together between power and neutral (ran a bypass over the terminal block so it’s running)
-asked Brendan to order new door lock for orange juice (temporarily used painters tape to keep it closed since they’re using door dash stickers which get stuck)
- Took code label for tiles gonna try to pick some up |
| 1129 | Jim | 11/29/2023 | 21582 | - replaced lobby ceiling tiles
- reattached lobby wallpaper
- ordered inside panel for walk - in freezer door |
| 1128 | Jim | 11/29/2023 | 10622 | - replaced power washer, old ones pump case froze and was destroyed , new one is in the box until spring inside the building
- repaired men’s room door frame
|
| 1127 | Waylon | 11/28/2023 | 18198 | today was a big learning curve for me
-Abs not dispensing coke and the Diet Coke shut off valve broke midway through and sprayed everywhere
-Replaced armature, two shut off valves and calibrated coke
-Replaced armature tip and solenoid for lobby coke and calibrated
-Called while at the store about abs broke they just needed to swap the backup co2 tank…
First time really working on the abs and I learned a ton about the soda system spent a good amount of the time on the phone with Brendan helping trouble shoot
-had Ashley call air gas to get more co2 since they only have one back up left
Everything’s working 🥳🥳🥳🥳 |
| 1126 | Jim | 11/28/2023 | 10622 | - replaced men’s room faucet with commercial kohler lifetime warranty
- replaced tailpiece on rear prep hand sink drain, no overflowing now
- adjusted men’s room door frame
- Tightened drive thru outside door handle |
| 1125 | Jim | 11/27/2023 | 12272 | - delivered multiple tile for contractor to repair damaged door |
| 1124 | Jim | 11/27/2023 | 04205 | - replaced 4 ends on walk-in lite and installed new bulbs with safety tubes
- Cleaned delivery door plexiglass window
- foamed holes in wall under sink |
| 1123 | Jim | 11/27/2023 | 02830 | - installed lower hinge on frappe machine
|
| 1122 | Jim | 11/27/2023 | 00596 | - checked ice machine drain, drain cleaner worked no standing water
|
| 1121 | Waylon | 11/27/2023 | 02038 | -Grill 1st bump bar originally frayed cable went to crimp a new end and was receiving no power from it so ran a whole new cable from computer to bump bar |
| 1120 | Waylon | 11/27/2023 | 02830 | -Called for abs thru beam sensor causing the abs not to work (sensor just needed to be tightened down and lined up with the other side) |
| 1119 | Jim | 11/27/2023 | 02830 | - installed lower hinge pin on shake machine
- checked handicap door buttons, three work the one inside vestibule for inside door is in-op needs battery, I have specs and will try to source |
| 1118 | Jim | 11/27/2023 | 00596 | - checked on ice machine drain, cleaner worked no standing water
|
| 1117 | Waylon | 11/27/2023 | 17371 | -Creamer is fixed and running - Replaced solenoid and push arm (only replaced push arm because old one was gross and nasty) |
| 1116 | Waylon | 11/27/2023 | 18198 | -was told no coke to abs the regulator on backup co2 was not letting enough co2 through the regulator fittings might be fault since it was icing up, but can’t do anything till their not on backup |
| 1115 | Jim | 11/24/2023 | 00596 | - Cleared second clog in men’s room toilet |
| 1114 | Jim | 11/24/2023 | 21582 | - Replaced hose on multiplex, active leak
|
| 1113 | Jim | 11/24/2023 | 00596 | - cleared men’s room toilet
- Worked on rear hand sink clog, drains very slowly
|
| 1112 | Waylon | 11/23/2023 | 00596 | -Looked at clogged sink that was also leaking out of P trap began to take it all apart began to find it was gonna be a lot bigger project then intended sent Jim the next day |
| 1111 | Waylon | 11/23/2023 | 02830 | -Went for both HLZ being down, replaced computer on side 2 HLZ
-Double check side 1 HLZ for heating all around and was working perfectly fine |
| 1110 | Waylon | 11/22/2023 | 18198 | -Took POS 2 power block and put it in register 14
-Wired Ethernet cable since register 14 went bad
-looked at abs was not connecting to register 14 (found out by Brendan it was a software problem) |
| 1109 | Jim | 11/22/2023 | 04205 | - Grouted tiles by water heater |
| 1108 | Jim | 11/22/2023 | 10544 | - re set men’s room urinal flush control, working fine no issues
- sourced proper fasteners for vestibule door handles and installed
- sink hose got clogged, replaced with stainless flex line, works fine
- manager asked to wait till ecosure inspection to replace mirror,
She will advise when inspection is over |
| 1107 | Waylon | 11/22/2023 | 17371 | -Went for creamer being down (looks like the solenoid plunger is going bad is was barely moving but after running it a lot and letting all ice build up breakdown was running back to normal asked Brendan to order one just in case going into thanksgiving weekend)
100% working at this time
- reprogrammed friar to display fish on a different vat since it’s down for Casco waiting on a fix instead of them cooking it on mc chicken timer
|
| 1106 | Jim | 11/21/2023 | 04205 | - Installed corner bead to half wall next to frappe machine
- remounted metal trim by exit door next to play place
- cut and installed two roof beam end covers
- replaced eleven boards on the corral |
| 1105 | Waylon | 11/21/2023 | 25383 | Removed 4 UHC strips
-Installed 4 brand new UHC strips on a newer set of cabinets so it was a little wonky
-Checked out the men’s hand dryers did not find a problem they said they were constantly running but both worked perfectly fine for me |
| 1104 | Waylon | 11/21/2023 | 07417 | Took longer then expected…
-Topper board on half wall above happy meal display case had to get rid off all old adhesive then put liquid nails on wall and board and resecured clamped it down and put tape to hold its place needs to sit 12 hours minimum |
| 1103 | Jim | 11/20/2023 | 10544 | Sourced and installed spray nozzle at sink, also had to clear water line for max pressure, works fine |
| 1102 | Jim | 11/20/2023 | 04205 | - ordered walk-in door gasket and sweep it will be at the store Friday 11/24/23
- preped acrylic for roof beam ends
- Ordered parts for walk in lite they will be in tomorrow morning
|
| 1101 | Waylon | 11/19/2023 | 12272 | -Homie ran into the building… patched up the back door hole
-cut out the rest of the Frame |
| 1100 | Waylon | 11/20/2023 | 07194 | -Installed new cashless device Dt2
-Installed pad on cashless |
| 1099 | Waylon | 11/20/2023 | 04956 | -Looks like someone on accident I assume turned a motor off to the lobby sodas so just turned it off and ran all the excess co2 out of the lines |
| 1098 | Jim | 11/17/2023 | 04205 | - repaired holes in FRP
- called company for walk in door left message
- installed new tiles by water heater
- replaced ceiling lobby tiles
- installed delivery door sweep |
| 1097 | Waylon | 11/16/2023 | 17371 | -Bump bar cable for front counter causing them to not serve (Took 15 mins but had to drive an hour and a half here)
-Picked up card reader paddles |
| 1096 | Jim | 11/16/2023 | 04205 | - installed ABS cover and cleaned off stickers
- straightened number two hand sink
- installed new 2X2 light at Drive thru #2
- Re fastened wallpaper in play place
- Replaced ladies room non handicap toilet vacuum rubber , leak stopped |
| 1095 | Brendan | 11/16/2023 | 12272 | Last minute RGR stuff, installed bump bars, tied down co2 alarm wires, tightened women’s toilet seat |
| 1094 | Waylon | 11/16/2023 | 12272 | -Created two full new cords for a freezer and fridge
-Hung the cords up with clips (short term solution) gonna make a hole in the table to run them through but Pam walked in
- Talked to Brendan and Michael about vacation / how it’s gonna run for two weeks
- Asked to fix toilet seat in woman’s room
|
| 1093 | Jim | 11/16/2023 | 12272 | - Grouted baseboard tiles
- Installed mop hanger
- replaced closet bolts and wax seal on men’s room toilet
- replaced three ceiling tiles in vestibule |
| 1092 | Jim | 11/15/2023 | 12272 | - Replaced two baseboard tiles
- repaired corner trim outside by drive thru one
- replaced casters and one leg on rolling cart
- repaired crack outside stock room door
|
| 1091 | Brendan | 11/15/2023 | 12272 | -Last minute RGR prep, had to order emergency light
-replaced a bump bar, took two back to repair
-installed cbb printer upgrade |
| 1090 | Brendan | 11/14/2023 | 12272 | -rgr prep
-installed new door closer which took waaayy longer than it should have
-removed old external RO tank, relocated water line to install new tank
-new install missing pre filter for RO system. RO system is not pumping, I don’t think it was before either. Will troubleshoot tomorrow
-troubleshooted music not playing, bad amp. On order.
-repaired electrical issue for camera monitor in front drive thru
-repaired window chain 2nd window
|
| 1089 | Waylon | 11/14/2023 | 12272 | -Went to south willow took signs for Londonderry drive thru
-Fixed bathroom light ballast
-Replaced bathroom light bulbs
-Fixed plate on door closer that was hiding holes
-Helped Brendan with RO tank
-Repaired water line to frappe machine another break in the hose😭
-installed new office camera
|
| 1088 | Jim | 11/14/2023 | 12272 | - installed multiple new ceiling tiles throughout the building
- replaced 10 Florescent bulbs
-installed rest of safety tubes in and around freezer |
| 1087 | Brendan | 11/13/2023 | 12272 | -USB switch box and bix upgrade. 5 printers installed |
| 1086 | Waylon | 11/13/2023 | 12272 | -Replaced Qing oven touch panel
-Took apart second Qing oven had door switch orders will be there tmrw
-Installed new ballast for lobby light (no light bulbs in store so ordered some)
-Recaulked holes behind bun rack I accidentally used clear caulk last time 😭
|
| 1085 | Brendan | 11/13/2023 | 25383 | -called for no soda water at ABS. Bad motor. Replaced pump and motor. Threw me for a loop because they have a 208v unit but the motors took 120 so wired it wrong the first time. Bizarre, you have 208 might as well use it
-troubleshooted pie merchandiser. No trouble found |
| 1084 | Brendan | 11/13/2023 | 02830 | -troubleshooted lane 1 speaker crackling not working well. Was a very bizarre case. Would only crackle if a headset was on that lane (even if their mic wasn’t on). Troubleshooted connections. Ohmed out steady at 6ohm which is expected for good speaker and wire connections. I believe it to be a bad base station. Called Jim at YES and said the same thing so he is going to drop one in tomorrow.
-looked at frappe machine drain pan, cracked base, on order
-went through list with mary |
| 1083 | Brendan | 11/11/2023 | 18198 | -looked for co2 leaks again…. I don’t think they have one I just think they have high demand, air gas says the same thing
-troubleshooted UHC burning people, needs new air probe, on order
-replaced Fanta bib pump
-looked at filet steamer leaking, needs new regulator assembly, on order
-ordered oil line for leaking fryer |
| 1082 | Jim | 11/13/2023 | 00596 | - showed store maintenance how to make sure top closer on walk- in doors are reset
- installed two hangers for ice buckets
- replaced batteries in ladies room handicap toilet
- Tightened men’s room spud nut , just a little loose
|
| 1081 | Jim | 11/13/2023 | 12272 | - Installed safety tubes on walk- in bulbs , also two bulbs were out so ordered them can pick up tomorrow morning
- replaced left drain handle, drains fine now
- replaced gasket on right side drain, no leaks
- installed ceiling grid piece
|
| 1080 | Waylon | 11/13/2023 | 02038 | -Replaced egg cooker switch, waited for it to power up and ran eggs through (Had to run eggs through twice since someone turned it off and was confused why it wasn’t working) Crazy right something doesn’t work when it’s off 🙀🤯🤯🤯🤯 |
| 1079 | Jim | 11/10/2023 | 17371 | - Ice machine inop on arrival, reset and ran clean cycle to no avail
- installed lite lense in stock room
- cleared men’s room urinal
|
| 1078 | Brendan | 11/09/2023 | 07194 | -replaced side 1 lunch monitor that died |
| 1077 | Jim | 11/09/2023 | 12272 | - finished RFP installation at present window
- built plastic cart
- cleaned and repaired fry holder |
| 1076 | Jim | 11/09/2023 | 12272 | - worked on RFP replacement at first drive thru and behind quarter freezer
|
| 1075 | Brendan | 11/08/2023 | 17371 | -troubleshooted co2 leak. Loose figal fitting on bulk coke tank
-repaired grill hand sink, new gasket and strainer basket
-QMP follow-up: replaced surge tank
-creamer upgrade |
| 1074 | Waylon | 11/08/2023 | 02038 | -fixed multiple tiles in grill near Hlz
-light lens stock room
-ballast stock room
-Vent cover in window
-Diafnosed egg cooker |
| 1073 | Brendan | 11/07/2023 | 04956 | QMP followup - replaced internal RO tank |
| 1072 | Jim | 11/07/2023 | 04205 | - went to clear toilet in men’s room , found no issues
All set |
| 1071 | Waylon | 11/07/2023 | 12272 | -Fixed leaking water line to frappe
-installed new door on double door fridge up front (aided by Jim holding the door)
-Had to drive to Hanover and take that fridge door from one in shed
-also picked up a light for pie merchandiser after searching for one just for Jim to have one….😡
-Sanded putty from yesterday in woman’s bathroom let Tara know it’s paint ready
|
| 1068 | Jim | 11/07/2023 | 12272 | - installed bathroom mirrors Two in men’s room and one in ladies room
- Grouted floor by sink
- helped Waylon install fridge glass door
- re plumbed ABS carrousel drain
- adjusted left sink to allow proper draining
- sourced and installed pie merchandiser light |
| 1067 | Brendan | 11/07/2023 | 10544 | -call back for no soda water. Carb B motor locked up. Replace motor and pump |
| 1066 | Brendan | 11/06/2023 | 12272 | -replaced 4 receipt printer bix/usb upgrade |
| 1065 | Brendan | 11/06/2023 | 10544 | -repaired issue with multiplex carb B. Needed new probe harness. Also adjusted 95psi co2 regulator that was set to 80, and 55psi regulator.
-QMP follow up: replaced vizion permeate tank and RO blend assembly |
| 1064 | Waylon | 11/06/2023 | 12272 | -Fixed metal freezer cover in grill
-Helped temporarily move muffin toaster
- resecured ice machine cover on to ice machine
- looked at front drive thru fridge rails was shenanigans
-caulked multiple holes in wall around store
-Putty women’s bathroom door (Sitting over night before sanding)
- began the intense investigation of finding a light to fit a TC 280-1 have not found anything 😅 |
| 1063 | Waylon | 11/06/2023 | 21582 | -Took apart oep into UHC closest to HLZ
-Installed new cord with old oep and new terminals on ends |
| 1062 | Brendan | 11/04/2023 | 04956 | -replaced shake side beater stem and cap
-checked on multiplex temp, has come down nicely
-checked temp of lobby soda. 39°, still higher than I would like even after replacing the pump and with full ice bin. Motor must be starting to die. Will order new one |
| 1061 | Brendan | 11/03/2023 | 10544 | -went for soda not working at ABS. Bad circ pump, overheating and causing the carb pump to also overheat and cutout. Co2 tanks also has bad 95 gauge. On order should return tomorrow |
| 1060 | Brendan | 11/03/2023 | 04956 | -returned to install IBC for multiplex, will return tomorrow morning after shake machine is cleaned to replace shake machine beater stem |
| 1059 | Jim | 11/03/2023 | 07417 | - Finished the corral
- Fixed McDonald’s sign on drive thru side outside
- attached corner trim at lobby beverage station
- replaced 4 lite lenses and 2 bulbs
- Tightened men’s room faucet
- cleared ladies room toilet |
| 1058 | Brendan | 11/03/2023 | 07417 | -finished corral project |
| 1057 | Brendan | 11/02/2023 | 07417 | -replaced RO external tank
-corral project |
| 1056 | Jim | 11/03/2023 | 07417 | -installed steel putty on sink edging
- Installed new ice maker cover
- Worked on corral
- changed multiple ceiling tiles
- repaired torn wall paper in beeakroom |
| 1055 | Brendan | 11/02/2023 | 10622 | -installed new OJ machine. Came with two broken legs. More importantly, has a refrigeration issue. Will be taken care of under warranty
-installed new vizion power supply |
| 1054 | Jim | 11/01/2023 | 07417 | - worked on corral with Waylon |
| 1053 | Brendan | 11/01/2023 | 04956 | -replaced UHC switch
-fixed second window chain who’s chain fell off
-checked status of how melted multiplex was to replace IBC. Not ready yet, should be ready as my last stop tomorrow so I will return then |
| 1052 | Brendan | 11/01/2023 | 04205 | -troubleshooted flat sodas. Found that IBC wasn’t calling for compressor to turn on. I poked it and it turned on. Reseated connector, should be all set when it comes down to temp, will continue to monitor. Also insulated circ pump/lines as it was missing
-made new cord for cash drawer pos13 |
| 1051 | Brendan | 11/01/2023 | 25383 | -no soda water at ABS; easy peasy-pump fell off of the motor. No idea how. Reattached and insulated circ pump that I noticed was missing some |
| 1050 | Waylon | 11/01/2023 | 07417 | -Tore down all old corral wood with Jim
-Unclogged ladies room toilet
-Helped drill brush the freezer floor clean
-installed creamer gasket since it has screws in it and needs a special nut driver |
| 1049 | Brendan | 11/01/2023 | 02038 | -troubleshooted ABS. No trouble found, working fine.
-troubleshooted McFlurry blender, swapping out under warranty |
| 1048 | Brendan | 11/01/2023 | 04956 | -many multiplex problems. Redid a lot of plumbing inside, replaced lobby circ pump, was having issues with probe and pressure relief. Unit totally iced up, needs new IBC. Turned off refrigeration to allow ice to melt and I will return to replace IBC once melted
-looked at leaks under SSBS; siliconed drain troff. Also found gasket on ice chute bunched up and not sealing, dripping slowly. Corrected that.
-replaced latch on oven door |
| 1047 | Jim | 11/01/2023 | 07417 | Replaced corral exterior on the gates
Tried to get welders working to to no avail |
| 1046 | Waylon | 10/31/2023 | 07417 | -Cleared one corner of corral wood out and took nails out plus trashed debris
|
| 1045 | Waylon | 10/31/2023 | 10544 | -Soda was out in whole store, multiplex water line into pump sprung leak causing water to spray everywhere had to cut it and recrimp the line.
they have soda now 🥳 |
| 1044 | Waylon | 10/30/2023 | 04205 | -Redid one grill ballast all lights in grill are all set
-Ballast in dt2 just gonna buy a new one since it’s probably around 50$ should be less, it’s an absolute disaster and is anchient plus multiple parts of the light are broken where it’s not fixable |
| 1043 | Jim | 10/30/2023 | 00596 | Checked rear sink water pressure, no issues found
Cleared from list |
| 1042 | Jim | 10/30/2023 | 07194 | - replaced drain handle on left side sink , holds water now |
| 1041 | Jim | 10/30/2023 | 07417 | - cleared ladies room handicap toilet
|
| 1040 | Waylon | 10/30/2023 | 07417 | -Worked on McCafe fridge the door was not fully closing I replaced the hinge (Typically the problem) after replacing the hinge it closes hard like it should but it doesn’t stay fully shut I’m kinda at a loss cause I’ve tried everything possible and I ended up asking Brendan to take a look at it |
| 1028 | Brendan | 10/24/2023 | 04956 | -went to replace circ pumps at multiplex. Everything went wrong, needs some parts on order
-installed rivet nuts on oven |
| 1039 | Jim | 10/27/2023 | 07417 | - built and installed new cover for lobby ice machine
|
| 1038 | Waylon | 10/26/2023 | 07417 | Lifted bowing ceiling by bun racks
Measure & Cut all wood to size for corral project |
| 1037 | Waylon | 10/26/2023 | 12272 | -Stupid ceiling project if the ceiling can barely be opened please contract it out freaking crazy mess stupid shenanigans absolutely outrageous 🙀 (PS I have no sleep so I’m fuming)
Good
Night |
| 1036 | Jim | 10/26/2023 | 07417 | - Re installed men’s room mirror
- Installed new ADA plate
- Installed new air fresheners in men’s room and ladies room
- Poured concrete at first drive thru curbing
- Grouted wall next to ice maker in back area |
| 1035 | Brendan | 10/25/2023 | 12272 | -replaced both door springs on drive thru fridge
-repaired drive thru window. Missing a bolt and needed alignment
-cut off and sanded old hinges in front of HLZ
-replaced light ballast women’s bathroom
-rescued special needs person from certain danger in women’s bathroom |
| 1034 | Jim | 10/25/2023 | 07417 | - Replaced six floor tiles and grouted
- replaced one why wall tile by quarter freezer
- cleaned out broken ADA plate and poured concrete |
| 1033 | Jim | 10/25/2023 | 00596 | - Adjusted door sweep on delivery door , closes on its own now |
| 1032 | Waylon | 10/25/2023 | 12272 | -Installed new co2 alarm almost finished need to get an extension cord and clips to finish running to the office
-Talked to Tara about plan for overnight ceiling tile project |
| 1031 | Brendan | 10/24/2023 | 07417 | -rekeyed detex cylinder to correct key and reinstalled
-trained Waylon on plumbing, installed new faucet
-troubleshooted frappe motor lock. Bad island oasis board, on order
-installed proper door closer for office door
-measured corral and sourced composite wood. Will be delivered tomorrow |
| 1030 | Waylon | 10/24/2023 | 07417 | -Repaired hole in wall from doing pvc on back sink still needs frp over it
-Worked on plumbing a sink upfront with Brendan
-Discussed corral project and cost for decking board exc
|
| 1029 | Jim | 10/24/2023 | 12272 | - Grouted all baseboard tiles needing grout
- installed diamond plate behind slop sink
- installed two baseboard tiles
- mounted two ice bucket holders |
| 1027 | Brendan | 10/23/2023 | 00596 | -troubleshooted muffin toaster, just a tripped breaker.
-finished bix upgrades
-replaced bulk coke figal |
| 1026 | Waylon | 10/23/2023 | 07417 | -Replaced 5 fry sockets
-Looked at upfront sink need to find correct o ring for the inside of it
-Here was a project in a half the stock room hand wash sink…. Well originally told it was clogged then found the who is plumbing setup was ducked…. Cracked pipe in the wall leaking out of the wall and someone covered it with spray foam 😡😡 and a shit Ton of caulking so I had to cut a 5x5 hole in the wall to get to the piping cut that all out and get new piping for it absolutely craziness
Also first time doing pvc in a wall… |
| 1025 | Brendan | 10/23/2023 | 21582 | -replaced lift cylinder
-replaced 1 cup holder
-investigated women’s room hand dryer not working, tripped gfci |
| 1024 | Jim | 10/23/2023 | 12272 | - Cut and installed two baseboard tiles
- Re installed Drive thru window chain
- Drywall mud around ceiling vent trim
- Removed campers and trailers signs
- cut and installed egg crate vents
- Grouted ladies room wall |
| 1023 | Brendan | 10/20/2023 | 04205 | -major soda issues. Both carb pumps/motors bad. Ran to grainger to pick up. Replaced both carb motors and pumps. Painstakingly removed tiny carbon rocks from ABS valve multiple times
-repaired coke valve in lobby |
| 1022 | Jim | 10/20/2023 | 12272 | - Swapped out ladies room toilet paper dispenser
- installed sheet metal over cup holes up front
- Installed cover on electrical box above prep area
- fixed men’s room vent
- disassembled and cleaned pieces of faucet at prep area hand sink , no leaks
- Installed mop hanger at slop sink
- Installed flag pole cover
- Dropped off two men’s room mirrors at Queen City glass |
| 1021 | Waylon | 10/20/2023 | 10544 | -Ripped out old co2 and finished new one fully functioning
-Installed central office unit and finish running one cord from stock room to office 🥳 |
| 1020 | Jim | 10/19/2023 | 04205 | - Replaced both under sink shut offs & both faucet cartridges on kitchen hand sink
- sourced and installed wheel for quarter freezer cover still needs a rubber bump stop under left side |
| 1019 | Brendan | 10/19/2023 | 17371 | -cleared frappe drain pan drain
-installed valve rebuild kit for sanitize bay
-repaired Dr Pepper valve in lobby |
| 1018 | Waylon | 10/19/2023 | 10544 | -Went to granite state fence got corral cane bolts
-Cut cane bolts to fit x3
-Installed other side of door handle from lobby side (had to cut to fit a screw cause the setup is stupid 😖😡
-Installed 2 more new co2 sensors and the sniffer unit
-Ran almost all the wires from one side of the store to the other basically got lost in the ceiling and everything was a knot 🪢🪢 |
| 1017 | Brendan | 10/19/2023 | 00596 | -bix upgrade, upgraded 8. Need to get power cords for others
-replace ice switch @ SSBS |
| 1016 | Jim | 10/19/2023 | 04205 | - Replaced both under sink shut offs & both faucet cartridges on kitchen hand sink
- sourced and installed wheel for quarter freezer cover still needs a rubber bump stop under left side |
| 1015 | Brendan | 10/19/2023 | 02038 | -replaced oring for leaking bun steamer |
| 1014 | Brendan | 10/19/2023 | 07417 | -RGR walk thru |
| 1013 | Jim | 10/19/2023 | 00596 | - Checked rear hand sink for leaks, none found but the aerator was missing and caused the water to splash over, installed new aerator problem solved
- installed new chain and clips for CO2 tanks |
| 1012 | Brendan | 10/18/2023 | 04956 | -fixed Zoom timer not turning on
-replaced printer 13
-insulated lines under SSBS |
| 1011 | Brendan | 10/18/2023 | 07417 | -finished bix upgrades
-rekeyed mortise in detex
-finished installing delivery monitor
-installed new bulk coke drain hose and jumper |
| 1010 | Waylon | 10/18/2023 | 10544 | -Finished drywall had to sand it down and cut spray foam to be even with wall then put new mud over it so that has to dry
- installed one co2 alarm not operational until the full system is set up
- Installed new door handle
-Called tech about Qing oven I couldn’t find anything wrong and he cleared the special code for it
- picked up men’s room mirror from Queen City and put back in
|
| 1009 | Jim | 10/18/2023 | 21582 | Replaced breaker # 12 in lower panel for ladies room dryer
Still inop |
| 1008 | Jim | 10/18/2023 | 04205 | - Picked up men’s room mirror and re installed |
| 1007 | Jim | 10/18/2023 | 07417 | - Re installed rear cover of ABS system
- Dropped off men’s room mirror to Queen City glass
- ice maker access cover refastened (without stickers)
- Installed new cover for blue hanging outlet
- shimmed right side coke tank |
| 1006 | Waylon | 10/18/2023 | 00596 | -Went to teach Jess (Maint) how to change a bun toaster Teflon & had to wait for it to cool down… |
| 1005 | Brendan | 10/17/2023 | 07417 | -installed 4 bix printer upgrades grill
-USB switch box upgrade |
| 1004 | Brendan | 10/17/2023 | 07194 | -replaced ABS touch pad
-dialed up Diet Coke valve in lobby
-troubleshooted card reader. It’s dead dead. STILL waiting on repairs and new ones to come in. 3 months later… |
| 1003 | Waylon | 10/17/2023 | 10544 | -Dry walking is stupid, so first time behind the soda bib rack you can’t move so it’s taking me forever. Right now the mud is drying
-Spray foam behind tiles next ti drywall for stability
-Light ballast stock room
- started looking at Qing oven then my meter died so called it a day
-Measured cane bolt special order for corral post
-Measure door handle for Brendan to order
-fixed water pump leaking just needed to be tightened |
| 1002 | Jim | 10/17/2023 | 12272 | - removed and replaced section of concrete walkway on Drive thru side entrance |
| 1001 | Jim | 10/17/2023 | 10622 | - replace GFCI outlet for creamer |
| 1000 | Waylon | 10/10/2023 | 10544 | -Mirror to Queen City glass
-Looked at Qing oven (CallServ) cleared code thinking it was a sham
-remount lobby” cris” letters
-Looked at mc chicken vat lever looked like it’s no longer locked into place
-did pie warmer adapter
-Grouted and mastic three tiles |
| 999 | Brendan | 10/16/2023 | 07194 | -ABS touch panel not working, stuck on manual; was able to get back into automatic, have a new touch panel being overnighted.
-repaired lobby root beer valve
-looked at BIM not working. Reboot solved |
| 998 | Waylon | 10/16/2023 | 07417 | -Lobby ice machine PM (Great start to the day until I found a broken plastic tray in the auger like bruh seriously 😒)
-Raised grill ceiling by bun racks up (Will not look perfect cause grid is bent due to someone running wires next to it without making a hole) 😐
-Tall urinal had no water (Obviously no water since someone turned the water off 🙀🤯)
- replaced curbside signs 1-6
-Made holes and post for curbside sign 1-2 spots |
| 997 | Brendan | 10/16/2023 | 10622 | -replaced board on OJ machine. Did not solve which means that unit has rotometers and encoders going bad. Parts more expensive than new machine. New machine on order
-repaired two lobby soda valves
-snaked out drain under prep sink |
| 996 | Jim | 10/16/2023 | 02038 | - Disassembled and straightened egg cooker covers and egg frames
- Grouted present area and fry area
- Grouted stockroom area by rear door
- installed mop hangers in both slop sinks |
| 995 | Brendan | 10/15/2023 | 07194 | -emergency weekend call for ABS spraying water everywhere. Took off lid holder and water started shooting up like a fountain. Screw that held in soda water flow control head snapped off, breaking the seal. Managed to get screw out of acrylic block and replaced. Water drenched the BI board and all the solenoids. Had to disconnect boards and solenoids to dry. Even stuck the board in the oven for a few minutes. Luckily the boards and solenoids were not fried and now operating fine! Unfortunately store lost about 200lb of co2 from the issue |
| 994 | Brendan | 10/12/2023 | 17371 | -troubleshooted FFLS. Just needed screen calibration…
-replaced relay board in filet steamer
-looked at back sink not holding water. Needs new gaskets. Rebuild kit on backorder should be here by end of month |
| 993 | Brendan | 10/13/2023 | 10622 | -troubleshooted OJ machine. Found OJ side had a bad button (even though it’s brand new). Replace the pair again have connectors a healthy dose of contact cleaner. Had to lube the pump shafts as well because was going into head lock
-repaired two lobby soda valves
-troubleshooted coffee brewer leaking. Bypassing brew solenoid, new solenoid and fitting kit on order |
| 992 | Jim | 10/13/2023 | 00596 | - built and installed new rear legs for stainless coffee table
Old legs broke off while moving |
| 991 | Waylon | 10/13/2023 | 21582 | This was crazy…
-Replaced HLZ heater plate (should not have taken 3 hours since I knew the problem but after hooking everything up the air heater was not coming anywhere close to temp or activating) after taking a lot of dust out of the motor and checking all the wires the plate relay seemed to take a slow amount of time to activate, but it heated up to temp eventually…
(I tested everything in the Unit😡😡🤬) |
| 990 | Jim | 10/13/2023 | 02038 | - re fastened lobby table top |
| 989 | Jim | 10/13/2023 | 04205 | -Grout fry area floor
- Tightened sink faucet to the wall and replaced leaking faucet neck
- re glued play place wallpaper and green Formica on wall |
| 988 | Jim | 10/13/2023 | 04205 | -Grout fry area floor
- Tightened sink faucet to the wall and replaced leaking faucet neck
- re glued play place wallpaper |
| 987 | Brendan | 10/13/2023 | 07194 | -went to troubleshoot frappe motor lock. Issue no longer present apparently Donald fixed it |
| 986 | Brendan | 10/13/2023 | 04205 | -replaced OJ concentrate motor and calibrated |
| 985 | Brendan | 10/12/2023 | 04956 | -I was on a wild goose chase with Raymond's frappe machine. No water to pitcher. Not the solenoid or armature. So I'm like wtf. I take off the line and blow in it and nothing all stopped up. So now I'm like wtf. Come to find out that the cabinet was at 30° so was freezing the water line. Also makes sense that once in a while that the strawberry banana would not stop dispensing. Strawberry banana is more water based than the other flavors so probably an ice chunk stuck in the pinch valve. Store to call Taylor for refrigeration issue
-replaced delivery monitor printer |
| 984 | Brendan | 10/12/2023 | 02038 | -ABS cup extract error again. Issue is a bad wire harness. Not made anymore so cut off connectors and crimped with an IDC |
| 983 | Brendan | 10/12/2023 | 00596 | -went to install ice dispenser parts but silly me ordered them to Hanover by mistake
-replaced lobby door closer |
| 982 | Waylon | 10/12/2023 | 07417 | -Abs ice machine PM
-Back ice machine Pm (was a pain because it decided to say it wasn’t working after cleaning it just for the water level probe need to be cleaned off 🤯 they’re so sensitive it’s crazy)
-Put new plastic glass for back door (my caulking broke and over sprayed 😞😒 but it’s not the end of the world)
-Put a new light lens in grill outside of office first one snapped on me 😡 |
| 981 | Jim | 10/12/2023 | 00596 | - Raised front coffee cabinet due to rear legs collapsed
|
| 980 | Brendan | 10/12/2023 | 12272 | -ABS not dispensing soda water, replaced carb water flow control
-dt window not working, chain came detached, reattached all set |
| 979 | Jim | 10/12/2023 | 04205 | - Grouted baseboard tiles
- replaced lite lenses and ceiling tiles
- installed steel leg for sink ( replaced modified broom handle)
- dropped men’s room mirror at Manchester GSG (granite state glass) |
| 978 | Waylon | 10/11/2023 | 12272 | -Picked up mirror still need to drop at Queen City glass
-Fixed leaking faucet the eye wash station was squirting out the sides (Used plumbers putty)
-Got the mcflurry screwed into the tile was actually really hard since I was hitting something in the wall so I had to build a holder
-Replaced stock room light ballast
-Ordered light ballast for women’s bathroom small stall
-Got Brendan part numbers and talked to Tara about a new co2 system
-Caught up a lot with Tara!🗣️🗣️ |
| 977 | Brendan | 10/11/2023 | 04205 | -troubleshooted BIM motor stall. No trouble found
-troubleshooted coffee brewer no water. Probe was getting grounded, all fixed
-troubleshooted OJ not dispensing concentrate, bad motor. On order
-replaced 4 printers, bix upgrade |
| 976 | Jim | 10/11/2023 | 04205 | - Replaced multiple ceiling tiles
- R & R baseboard tiles and grouted
- caulked holes in lobby wall from TV removal |
| 975 | Jim | 10/11/2023 | 00596 | - Patched pot hole at second drive thru window
- Re glued wallpaper in lobby
- Installed new tile in vestibule |
| 974 | Waylon | 10/11/2023 | 04956 | Cleaned the bin and underside of ice machine plus cleaned the louvers that you can’t take out waiting for health inspector |
| 969 | Waylon | 10/06/2023 | 25383 | -Fixed more drive thru curbing
-fixed lobby baseboards
-grouted all of tiles
- replaced grout in lobby and by office door |
| 973 | Brendan | 10/10/2023 | 07417 | -installed most of delivery monitor
-replaced 4 printer with bix upgrades
-blew out frappe drain
-Replaced bypass regulator @ RO |
| 972 | Jim | 10/10/2023 | 07194 | - Re connected ceiling duct and installed two ceiling tiles
- Removed and cleaned ceiling grid vent cover
- 4:1 drawer was fixed by in house maintenance
- straightened and re set #4 curbside sign
- Tightened ladies room partitions
- Got two keys for lobby maintenance closet
- Grouted baseboard tiles
- Replaced lobby ceiling tile |
| 971 | Brendan | 10/10/2023 | 04956 | -recrimped bump bar dt runner
-was going to install parts for frappe machine. No trouble found |
| 970 | Brendan | 10/10/2023 | 02038 | -replaced ABS drip tray
-replaced and calibrated ABS index and qfull sensors
-repaired coffee brewer spigot leaking, rebuild kit
-repaired front sink not giving cold water |
| 968 | Waylon | 10/05/2023 | 25383 | -RGR
-Ripped up 25 tiles and placed new ones
-Fixed more than half of drive thru curbing
ABolted down coke tank
-More random stuff I was asked to do |
| 967 | Waylon | 10/09/2023 | 07417 | Fix tiles above back drive thru had to redo twice since it was my first time tiling upside down and didn’t look good at first
-Raised up grill ceiling |
| 966 | Waylon | 10/10/2023 | 04956 | -Replaced bottom row second cabinet UHV strip since programming button was pushed down again very weird coincidence second time in the passed two months
-Reprogrammed top slot for first UHC cabinet for them |
| 965 | Jim | 10/10/2023 | 02830 | -Trimed weatherstripping and adjusted closer, needs new door closer as the old one doesn’t have enough adjustment left to properly close door
- Washer was set on rinse and spin only
- ladies room handicap toilet needed new batteries in the flush control slow flushing , drain cleared
Re righted wall bracket for faucet |
| 964 | Brendan | 10/09/2023 | 00596 | -troubleshooted lobby ice, need new button. On order
-looked at lobby door closer. Leaking, new on order
-repaired shake machine vanilla |
| 963 | Brendan | 10/09/2023 | 17371 | -troubleshooted frappe black screen. No trouble found
-troubleshooted OJ machine not dispensing. Two bad bags. All set.
-troubleshooted filet steamer. Bad relay board, on order.
-troubleshooted no soda water at ABS, loose wire, all set |
| 962 | Jim | 10/09/2023 | 07417 | - replaced corral boards as needed and re fastened gate on left to frame
- replaced office door closer |
| 961 | Jim | 10/09/2023 | 04205 | - snaked men’s room toilet, need commercial snake, outsourced |
| 960 | Brendan | 10/06/2023 | 25383 | -last minute touchups
-sweetener upgrade
-installed cube guide, float stem and float @ ABS ice |
| 958 | Brendan | 10/04/2023 | 04956 | -troubleshooted co2 leak. Loose connection on figal fitting to coke tank head |
| 959 | Brendan | 10/04/2023 | 07417 | -receipt printer issues in grill |
| 957 | Brendan | 10/05/2023 | 25383 | -replaced chains in dt windows
-recrimped dt runner bump bar and replaced |
| 956 | Brendan | 10/05/2023 | 10622 | -replaced dt present monitor
-investigated rootbeer issue, no trouble found |
| 955 | Waylon | 10/04/2023 | 25383 | -ice machine Pm front and back
-Ceiling tiles
- started on window chain WASNT the right size
- started on beverage fridge light wasn’t gonn work
|
| 954 | Jim | 10/04/2023 | 04205 | -re tightened men’s room toilet pipe, no leaks |
| 953 | Jim | 10/04/2023 | 25383 | - Re fastened pay here bracket and installed new sign
- Framed water shut off outside and painted siding |
| 952 | Brendan | 10/04/2023 | 25383 | -bix grill printer upgrade install
-usb switch box upgrade install
-OJ machine install/calibration
-ordered chains for dt windows, closer springs for dt fridge, ice machine float, stem, and cube guide
-installed EPR printer |
| 951 | Brendan | 10/03/2023 | 04205 | -called for co2 not working. Just needed to press the reset button |
| 950 | Brendan | 10/03/2023 | 25383 | -ABS kept conveyor stalling. Bad index sensor, replaced and calibrated.
-removed walk-in emergency latch and cleaned up threads.
-repaired sprite valve SSBS
-7 bix printer upgrade
-completed deliver monitor setup
-replaced first breakaway cord on ped14, i think it should be ok maybe |
| 949 | Waylon | 10/03/2023 | 25383 | -Fixed Qing oven bad transformer was causing the contractor to read bad (Replaced transformer)
-Helped Debbie switch to backup co2
-Helped Debbie installed new drive thru signs
-Ice machine PM on abs machine found a broken grid turned off until new one comes in
-Replaced one full led light
-Replaced 2 egg crates
-Replaced one light lens |
| 948 | Jim | 10/03/2023 | 07417 | - straightened exterior walls of corral, greased the gate hinges, and replaced some boards |
| 947 | Jim | 10/03/2023 | 12272 | Left and center sink drains slow, cleared w/ air pressure |
| 946 | Jim | 10/03/2023 | 25383 | - removed straps from Corral, posts reset
|
| 945 | Brendan | 10/02/2023 | 00596 | -replaced base of frappe machine and installed new drain pan. Obnoxiously big project.
-affixed temp control box in walk-in freezer |
| 944 | Brendan | 10/02/2023 | 25383 | -repaired two SSBS valves. Sprite still needs a new solenoid but ran out. On order.
-diagnosed both dt windows, motors and chains on order.
-installed new music player for lobby music
-troubleshooted card reader. It’s dead. Still waiting for swaps
-ordered door for fried freezer and qing oven as well |
| 943 | Waylon | 10/02/2023 | 25383 | -Diagnosed Qing oven (Bad fuse, transformer was smoking, and capacitor was reading infinite resistance so also seemed bad)
-Diagnosed second Qing oven seemed to only be a bad fuse |
| 942 | Jim | 10/02/2023 | 25383 | - Repaired drive thru curbing
- straighten corral walls and re cemented posts
|
| 941 | Waylon | 10/02/2023 | 04205 | -Replaced 3 fry sockets
-Had to sanitize the tea brewer since they ran Diet Coke through it instead of sweetener 😭 like how 🤔🤕 |
| 936 | Brendan | 10/02/2023 | 10544 | -replaced breakaway cable ped15
-quoted new enter/exit signs |
| 940 | Jim | 10/02/2023 | 04205 | -Installed roof vent fan motor for nugget fryer
- picked up two fry bulb’s from south willow for Waylon |
| 935 | Brendan | 10/02/2023 | 02038 | -new connector dt runner bump bar
-called for ABS not working. No trouble found, just cracked cup tube, on order |
| 934 | Waylon | 09/29/2023 | 10622 | Replaced Dr Pepper pump the pump started to go bad
Pulled up a tile in front of abs and walked behind and looking for any worms did not find anything tile was completely dry |
| 933 | Jim | 09/29/2023 | 02830 | - re set drive thru curbing |
| 932 | Jim | 09/28/2023 | 25383 | -Grouted sink floor area and nugget fryer floor area
- worked with Waylon to install and test the new CO2 alarm system
Installed OEP caps (two)
Installed new pie merchandiser light |
| 929 | Jim | 09/28/2023 | 02038 | Measured three broken tables
|
| 928 | Waylon | 09/28/2023 | 25383 | -Installed new co2 system fully
-worked with Jim on OEPs he struggled just like I did so they are on their the springs are just not loaded |
| 927 | Waylon | 09/28/2023 | 00596 | -New qtr monitor
-Figure out washing machine leak |
| 926 | Jim | 09/27/2023 | 07417 | -replaced washing machine, hoses and connections
- outdoor table brace and broken outdoor trash bin dumped into dumpster
|
| 925 | Jim | 09/27/2023 | 02038 | - replaced washing machine water shutoff due to corroded connections
|
| 924 | Waylon | 09/27/2023 | 25383 | -Fixed alarm hanging
-Took a top of an OEP that was broken off couldn’t install new one
-Crated a new cord for cheese fridge and spliced into old
- Installed new touch panel on filet steamer
-Looked at co2 new alarm system made a plan for where it’s all gonna go |
| 923 | Jim | 09/21/2023 | 10544 | - R&R men’s room flush controls to manual
- installed new wire, plug, and outlet on baking oven , found three where’s off the black wire lug sparking when power was on
Removed and cut and reinstalled/ issue fixed
- ordered new door handle for vestibule door / From Kelly brothers in Hudson |
| 922 | Waylon | 09/26/2023 | 25383 | Breakfast fridge cord started on OEP covers but i need a c clamp |
| 921 | Jim | 09/26/2023 | 02038 | Replaced the clod water line for the washer |
| 920 | Jim | 09/26/2023 | 10544 | - Re drilled and installed toilet paper holder in ladies room
- Blasted men’s room urinal, cleared drain |
| 919 | Jim | 09/26/2023 | 25383 | -Picked up repaired mirrors for bathrooms and re installed
|
| 918 | Waylon | 09/26/2023 | 10622 | -Dr Pepper soda pump need new oring
-Fixed one tile coming up and grouted
-Fixed men’s sensor for bathroom toilet
-Looked at women’s restroom sink too hot read 112 degrees I see that as fine cause we look for 105-110 |
| 917 | Waylon | 09/25/2023 | 07194 | Muffin toaster element |
| 916 | Waylon | 09/25/2023 | 21582 | -Replaced OJ water motor
-Looked at coffee brewer was nothing wrong with it brewed a pot perfectly fine |
| 915 | Jim | 09/25/2023 | 00596 | Remounted wall panel next to washing machine and sealed around cleanout |
| 914 | Jim | 09/25/2023 | 02830 | - sourced and installed new toilet for men’s room / toilet broken
|
| 913 | Waylon | 09/21/2023 | 18198 | Ice machine PM cause of 🪱🪱
Tried to rebuild fully rusted abs frame temporarily fixed until Jim can cut my metal |
| 912 | Waylon | 09/20/2023 | 18198 | 🪱🪱🪱🪱🪱🪱 |
| 911 | Brendan | 09/22/2023 | 02038 | -went to office to pick up register with bad touch screen. Found the actual issue it that it was not plugged in.
-set up camera system with guarding vision app, corrected time, and set NTP server |
| 910 | Waylon | 09/22/2023 | 17371 | -Adjusted water valves for sink next to shake machine and men’s room
-Tested temperature on all bathrooms and sink near shake machine all heated to 105+ in less than 20 seconds |
| 909 | Brendan | 09/22/2023 | 07194 | -replaced PED15 breakaway cable |
| 908 | Jim | 09/21/2023 | 10544 | - R&R men’s room flush controls to manual
- installed new wire, plug, and outlet on baking oven , found three wires off the black wire lug sparking when power was on
Removed and cut and reinstalled/ issue fixed
- ordered new door handle for vestibule door / From Kelly brothers in Hudson |
| 907 | Brendan | 09/22/2023 | 10622 | -BOS 2016 |
| 906 | Jim | 09/21/2023 | 25383 | Turned up mixing valve at hot water tank
Problem solved |
| 905 | Jim | 09/21/2023 | 10544 | - R&R men’s room flush controls to manual
- installed new wire, plug, and outlet on baking oven , found three where’s off the black wire lug sparking when power was on
Removed and cut and reinstalled/ issue fixed
- ordered new door handle for vestibule door / From Kelly brothers in Hudson |
| 904 | Brendan | 09/21/2023 | 10544 | -BOS 2016 |
| 903 | Brendan | 09/21/2023 | 21582 | -emergency call; replaced line going to prefilter |
| 901 | Brendan | 09/20/2023 | 18198 | -RHS 2016 |
| 900 | Brendan | 09/20/2023 | 00596 | -troubleshooted cash drawer. Frayed cable. Built new one up |
| 899 | Jim | 09/20/2023 | 12272 | Replaced multiple ceiling tiles |
| 898 | Jim | 09/20/2023 | 07194 | - replaced left fryer cord and had to troubleshoot fryer power issue/ hood cleaners forgot to flip switch on roof vent
|
| 897 | Brendan | 09/20/2023 | 21582 | -BOS 2016 |
| 896 | Brendan | 09/20/2023 | 07417 | -BOS 2016 |
| 895 | Brendan | 09/20/2023 | 18198 | -worms 🪱
-deinstalled condenser under ABS and replumbed waterlines into ABS |
| 894 | Brendan | 09/19/2023 | 02038 | -BOS 2016 |
| 893 | Brendan | 09/19/2023 | 10544 | -RHS 2016 |
| 892 | Jim | 09/19/2023 | 25383 | - Put together drive thru curbing and re- cemented
- patched hole in front of delivery door |
| 891 | Waylon | 09/19/2023 | 02038 | -Installed new egg cooker switch
-Installed out back detex and made 5 keys for the store for them |
| 890 | Brendan | 09/19/2023 | 25383 | -BOS 2016 |
| 889 | Brendan | 09/18/2023 | 21582 | -RHS 2016
-removed bun rack, installed shelf |
| 888 | Waylon | 09/19/2023 | 21582 | -Diagnosed HLZ prob error after further look ended up being the plat heater so ordered a new one
-Had a new pep cover ordered
-Looked at cabinet “issue” found nothing to be wrong with it or any strips
- removed any other shenanigans from list |
| 887 | Waylon | 09/18/2023 | 07194 | -Replaced main board on filet steamer
-rehung plastic strip dangling in second drive thru window
-Fixed Jim’s plumbing that was sent lined up and added a water guard so it wouldn’t go on the floor anymore |
| 886 | Brendan | 09/18/2023 | 04205 | -BOS 2016
-removed bun cart and installed shelf for computers |
| 885 | Jim | 09/18/2023 | 25383 | - Adjusted hot water in both bathrooms seems to heat up faster now
- Tried to adjust nugget freezer door to no avail, door is warped and the inside panel is delaminating, this may be the cause of the warp in the door
- removed one TV from lobby and patched the ceiling hole
- Grouted by nugget freezer
|
| 884 | Brendan | 09/18/2023 | 00596 | -recrimped breakfast side 1 bump bar |
| 883 | Brendan | 09/18/2023 | 12272 | -RHS 2016
-installed motor @ left side fry hopper |
| 882 | Waylon | 09/18/2023 | 02038 | -diagnosed egg cooker bad switch ordered
-Fixed leaking sink nozzles out back just needed to be tightened
-Fixed bad UHC strip tested the rest only one was bad |
| 881 | Brendan | 09/18/2023 | 10544 | -reimaged pos1 new ssd
-troubleshooted pie merchandiser. Bad breaker. Will pick one up and return tomorrow |
| 880 | Brendan | 09/15/2023 | 02038 | -replaced side 1 lunch monitor
-replaced cbb printer
-investigated leak under lobby sodas. Hose fell out of drain.
-RHS 2016 |
| 879 | Brendan | 09/15/2023 | 07417 | -picked up monitor from crew room
-repaired creamer, new door cable installed
-replaced pos1 power adapter
-found issue with FC left SSBS, tripped breaker |
| 878 | Waylon | 09/15/2023 | 04956 | -Replaced UHC strip 3rd row closest to HLZ
- secured coke sanitizer in to walk out two 40 LB anchors in it (I think it should be put on studs but means lines will have to be redone)
-Replaced pie merchandiser switched
-Reinstalled new hand soap dispenser
-Diagnosed error code for egg cooker gonna wait to see if it comes up in the future to take action on |
| 877 | Waylon | 09/14/2023 | 25383 | -went to diagnose men's hand dryer found relay on the board wasn't clicking replaced with new board now up and running |
| 876 | Waylon | 09/14/2023 | 21582 | -diagnose hand dryer for woman's room no power going into it diagnosis is bad breaker |
| 875 | Jim | 09/14/2023 | 25383 | -Lifted and leveled ceiling above rear grill
- frappe machine drain cleared
- Cut and installed last diamond plate on freezer wall
- replaced corner baseboard tile, will grout when I grout floor areas
- R&R backflow preventer at sink
- Installed corner bead at # 1 Drive thru |
| 873 | Jim | 09/13/2023 | 17371 | - replaced three lite lenses in back area
-remounted # 5 & 6 drive up signs
- installed mop sink holder
- sourced and installed what fence post & 4 rails
- cut and replaced two lite lenses at # 1 drive thru
|
| 872 | Brendan | 09/14/2023 | 02038 | -called for flooding stockroom. Broken water line going into IMF filter. Repaired and abandoned old blue accumulator tank |
| 871 | Waylon | 09/14/2023 | 07417 | Replaced switch for UHC cabinet farthest from HLZ
Retaped soda drink station it's going in a year |
| 870 | Brendan | 09/14/2023 | 17371 | -RGR prep
-replaced exit sign
-replumbed grill hand sink |
| 869 | Waylon | 09/13/2023 | 04956 | -Replaced egg cooker receptacle
-Egg cooker cord
-Egg cooker SSR
Ran and started egg cooker works like a gem |
| 868 | Brendan | 09/13/2023 | 25383 | -ordered backflow preventer
-RHS 2016, had to pull out shelf and clean out 3 generations of wires and trash lol |
| 867 | Jim | 09/13/2023 | 17371 | - replaced three lite lenses in back area
-remounted # 5 & 6 drive up signs
- installed mop sink holder
- sourced and installed what fence post & 4 rails
- cut and replaced two lite lenses at # 1 drive thru
|
| 866 | Waylon | 09/12/2023 | 17371 | -Replaced muffin toaster cord someone zip tied the contractor in
-did a bunch of lobby ceiling tiles and cleaned multiple tiles |
| 865 | Waylon | 09/11/2023 | 12272 | Reinforced ceiling
Talked with Doug from ricks guys about ac leaking on to tiles causing them to crumble was ruled off as condensation on the pipe
Replaced two lobby tiles that were water damaged
Installed 2 new led lights side 2 of grill and the back stock room |
| 864 | Waylon | 09/13/2023 | 17371 | -Fixed cord that was cut on egg cooker
-Fixed fry socket in fry station
-Fixed ceiling lifting
|
| 863 | Brendan | 09/12/2023 | 18198 | -BOS 2106 |
| 862 | Brendan | 09/12/2023 | 07417 | -RHS 2016
-troubleshooted pos14 no power. Dead power supply. Will check at office tomorrow for extra |
| 861 | Brendan | 09/12/2023 | 04956 | -BOS2016
-troubleshooted pie merchandiser, bad power switch. On order
-troubleshooted melitta door open constantly. Misligned switch. All set. |
| 860 | Brendan | 09/12/2023 | 07194 | -RHS 2016
-diagnosed bun steamer. New board and water tube on order
-replaced shutoff block for hi-c lobby valve
-repaired leaky rootbeer line. New pump and orings. |
| 859 | Jim | 09/12/2023 | 25383 | - installed new corner bead at slop sink
- installed new mop holder and modified and relocated spray bottle rack
- installed diamond plate along freezer wall
- repaired lifting wallpaper in lobby
- installed shim to tighten syrup tank on left |
| 858 | Jim | 09/12/2023 | 02830 | - air blasted ladies room toilet & ran a snake, clog cleared
|
| 857 | Brendan | 09/12/2023 | 10622 | -picked up flash drive I forgot
-replaced buttons on lemonade and OJ. Cleaned and lubed OJ side |
| 856 | Jim | 09/11/2023 | 07417 | - Rear door threshold freezer exterior door two thresholds
Removed straightened and shimmed as needed ,then remounted
- Sealed cracks in sink
- raised walkway to meet freezer door so hand pallet can be used |
| 855 | Jim | 09/11/2023 | 10622 | - cleared ladies room toilet with air and snake |
| 854 | Brendan | 09/11/2023 | 17371 | -replaced 2 grill printers
-found and installed lobby shade cover (thanks Waylon lol)
-calibrated lemonade
-troubleshooted fryers. Having trouble, think it's a contractor. Store to call casco
-sweetener upgrade
-ordered more lobby soda valve covers and labels
-reimaged pos1 |
| 853 | Brendan | 09/08/2023 | 10622 | -repaired both Diet Coke valves
-ordered buttons for OJ machine
-RHS 2016 upgrade/ssd replacement |
| 852 | Brendan | 09/08/2023 | 00596 | -coffee pot not brewing; replaced fill solenoid
-tried to replace drain pan, but standoffs are all broken. New base on order
-replaced bathroom knobs with push pads and handles
-replaced microswitch in left coke valve
-troubleshooted no water at OJ. Clogged filter, bypassed |
| 851 | Jim | 09/08/2023 | 07194 | -Adjusted corral gates so they don't hit the ground when they swing open
- installed new tail piece on prep sink |
| 850 | Brendan | 09/08/2023 | 02038 | -replaced wire harness from SB to MCB
-replaced travel sensor
-cleaned travel sensor contacts
-fixed printer15 |
| 849 | Jim | 09/08/2023 | 04205 | Re mounted fascia board on overhang at Drive thru one and installed flashing |
| 848 | Brendan | 09/08/2023 | 04205 | -replaced circ pump to clear black soda water. Coming out clear now
-fixed merge monitor not displaying |
| 847 | Brendan | 09/07/2023 | 17371 | -cleaned out boxes from crew room
-replaced IBC probe multiplex
-replaced backup co2 regulator
-ran and replaced bump bar cable present window
-corrected issue with PED15
-replaced SSD pos1 reimaged
-ordered disconnect for window 2 air curtain
-BOS 2016 upgrade |
| 846 | Waylon | 09/07/2023 | 17371 | -Installed new top display board for Qing oven facing grills
|
| 845 | Jim | 09/07/2023 | 17371 | - leveled six picnic tables
- Grouted behind bench in lobby
- Grouted three wall tiles up front |
| 844 | Waylon | 09/07/2023 | 18198 | -UHC cabinet strip wouldn't switch to lunch I assumed it was the display board due to the fact I just replaced the strips recently, after testing the board it was not the board that was bad, so looked more into it and found the cable was half burnt off which caused it to not be able to properly work |
| 843 | Brendan | 09/06/2023 | 02038 | -called about ODMB. No trouble found.
-troubleshooted ABS. new travel sensor on order |
| 842 | Brendan | 09/06/2023 | 04205 | -replaced defective index sensor and calibrated
- troubleshooted charcoal colored soda water. Bad circ pump. Will come during a morning to replace
-replaced defective RO permeate tank
-RHS 2016 upgrade |
| 841 | Jim | 09/06/2023 | 17371 | - grill hood vent dents removed
- egg cooker wheel installed
- meat freezer by grill front right wheel replaced
- cut & installed three wall tiles up front
- re installed tape between fry station bin and fryer
|
| 840 | Waylon | 09/06/2023 | 10544 | -Fixed multiple tiles under ice bin upfront and regrouted the whole area plus grouted back sink tiles
-Put a plat cover on and removed detex they had no metal covers or black so it's a off white
-took abs cover for South willow |
| 839 | Brendan | 09/06/2023 | 21582 | -troubleshooted ABS. Conveyor loose. Tightened up all set
-investigated roof extension. It's fine
-looked at corral spigot. Store to call east coast |
| 838 | Brendan | 09/05/2023 | 04956 | -replaced ABS thrubeam sensor
-troubleshooted fryer filter. o-rings missing, new on order |
| 837 | Brendan | 09/05/2023 | 02038 | -troubleshooted ABS, calibrated index sensor |
| 836 | Brendan | 09/05/2023 | 00596 | -repaired coffee brewer, new switch and abandoned obsoleted parts |
| 835 | Brendan | 09/05/2023 | 04205 | -troubleshooted ABS. MCB on order |
| 834 | Waylon | 09/05/2023 | 17371 | -Fixed faucet jiggly tighten bolts underneath
-Replaced door hinges on makita fridge and the fridge that has the cream dispenser
-Installed new large cup abs tower
- Took out old and cut to fit new plexi glass for back door than caulked the edges (Epoxy the plexi glass in)
- installed new grill camera old one broke
-fixed silver strip on fc was bent back used epoxy to set it back in place |
| 833 | Jim | 09/05/2023 | 02038 | - Sourced and replaced washing machine |
| 832 | Jim | 09/05/2023 | 04205 | - removed water damaged window surround in play place window and repaired |
| 831 | Jim | 09/05/2023 | 02830 | - R&R toaster belts |
| 830 | Brendan | 09/05/2023 | 07194 | -replaced steamer temp probe
-programmed steamer for best burger
-replaced platen 3 standby button |
| 829 | Jim | 09/01/2023 | 10622 | - Re crimped water line that came loose, also opened valves and plugged in two pumps. Checked for leaks, all set |
| 828 | Jim | 08/31/2023 | 17371 | - sourced and replaced right rear sink drain
- adjusted men's room toilet for proper flow
- remounted hand soap dispenser at front hand sink |
| 827 | Jim | 08/31/2023 | 17371 | - sourced and replaced right rear sink drain
- adjusted men's room toilet for proper flow
- remounted hand soap dispenser at front hand sink |
| 826 | Jim | 08/31/2023 | 02038 | - installed ew cartridge and still leaking, need new faucet |
| 825 | Jim | 08/31/2023 | 12272 | Repaired lower left hinge on hanging double freezer and installed new bushing on bottom hinge pin |
| 824 | Jim | 08/30/2023 | 02038 | - tried replacing the hot cartridge o-rings to no avail went to granger to order new cartridge
|
| 823 | Jim | 08/30/2023 | 02830 | Replaced hood vent fan motor for fryer |
| 822 | Jim | 08/29/2023 | 02830 | - checked roof vent for fryer and spun pulley to get motor turning need new motor, but works for now |
| 821 | Jim | 08/29/2023 | 07417 | - patio edging lifted , re set lifted edging in multiple areas
- rear sink issue leaking, cleared drain with two air blasts, tested and found no leaks or back up to other sink issues |
| 820 | Jim | 08/29/2023 | 07417 | - patio edging lifted , re set lifted edging in multiple areas
- rear sink issue leaking, cleared drain with two air blasts, tested and found no leaks or backing up issues |
| 819 | Jim | 08/29/2023 | 18198 | -Installed rear door crash bar
- replaced drain gasket on center sink and glued pvc drain pipe on the left side |
| 818 | Jim | 08/29/2023 | 12272 | - caulked backsplash at sink |
| 817 | Jim | 08/29/2023 | 02830 | - checked roof vent for fryer and spun pulley to get motor turning need new motor, but works for now |
| 816 | Jim | 08/28/2023 | 12272 | - Steam cleaned wall behind sink, installed diamond plate panels
- purchased and swapped out washing machine
- repaired men's room left sink drain, was rotted away |
| 815 | Jim | 08/24/2023 | 02038 | -Installed drain cup for under ABS and ran new flex line from present table to drain
- replaced right side sink drain gasket
- replaced o-ring on hot water handle at slop sink |
| 814 | Brendan | 08/24/2023 | 00596 | -troubleshooted coffee brewer. Has a bad switch. Also disconnected obsoleted parts: blanket warmer, tea line warmer, pot warmer plates. Switch on order. |
| 813 | Brendan | 08/24/2023 | 07194 | -troubleshooted filet steamer. Bad temp probe, on order
-replaced chain or present window.
-replaced detex door sensor, but wires are crumpled. Will need to run new wire a different day |
| 812 | Waylon | 08/23/2023 | 10544 | Had to re plumb part of the abs and the drain from Jim cutting some corners on the plumbing
And regrouted tiles in drive thru |
| 811 | Waylon | 08/24/2023 | 10544 | Had to fix Jim's tiles disaster on the back door and put tiles in next to dish sink '? |
| 809 | Brendan | 08/24/2023 | 10544 | -RGR walkthru
-replaced up front merge point monitor
-sweetener upgrade
-installed eProduction printer |
| 808 | Jim | 08/24/2023 | 10544 | - Bondo under right side of sink
- build hanger for ice bucket
- cut floor tiles for rear door area
|
| 807 | Brendan | 08/23/2023 | 04205 | -called for leak under ABS. Found many issues with drain plumbing leaking. Corrected issues. Still a small leak by ice bin drain. Jim will fix it next visit.
-replaced prefilter
-gave ABS a tuneup. Adjusted index sensor and cup sold out sensor. Replaced two cup fingers and adjusted. Working great now. |
| 806 | Brendan | 08/23/2023 | 10544 | -installed bixolon grill printers, new cables and switchbox
-replaced backflow in multiplex to clear co2 leak
-installed eProduction printer
-replaced OEP on bun toaster |
| 805 | Jim | 08/23/2023 | 10544 | Steam cleaned FRP around sink and re- applied caulking around top of sink backsplash
|
| 804 | Jim | 08/23/2023 | 04205 | - installed FRP around ABS system and repaired ice bin drain |
| 803 | Jim | 08/23/2023 | 10622 | - replaced men's room faucet |
| 802 | Waylon | 08/23/2023 | 10544 | -Helped steam clean all of the back sink and caulk
-Stole abs cover and side panel from south willow and installed in Nashua
|
| 801 | Waylon | 08/23/2023 | 04205 | -Installed new frp
-Had to fix a couple plumbing issues
-Regrout tiles from Monday
-Grout behind abs
|
| 800 | Brendan | 08/23/2023 | 07417 | -fry station down; bad switch, ran to store and replaced. |
| 799 | Brendan | 08/23/2023 | 18198 | -Tech issues. Monitor swapped on kvs1. Pilot software bug. Implemented a workaround and sent to national |
| 798 | Jim | 08/22/2023 | 10544 | - replaced light cover for 2x4 ceiling lite
- rebuilt pvc drain for ice bin
- snaked ladies room handicap toilet, all clear |
| 797 | Brendan | 08/22/2023 | 04956 | - Troubleshooted 3 friers. One was unplugged other has dirty probe
-troubleshooted shake machine. Store to replace orings |
| 796 | Waylon | 08/22/2023 | 00596 | -Cut and placed two tiles mastic and grouted
-Worked on diagnosing coffee brewer (Tested with Brendan - I think there's a wire hitting metal somewhere but not sure)
-Ice machine pipe was done by east coast & snakes drain |
| 795 | Waylon | 08/21/2023 | 04205 | -Moved abs
-Tiled and grouted
-Ripped frp up
-Steam cleaned |
| 794 | Brendan | 08/22/2023 | 02038 | -replaced dead dt runner monitor. Had to install vertical. Stubborn, program has a bug. Fixed it and sent to national |
| 793 | Jim | 08/21/2023 | 04205 | - moved ABS system to repair walls
- removed FRP next to and behind ABS system
- holes in walls filled
- installed 6 floor tiles
- ran two new drain lines for ABS
|
| 792 | Brendan | 08/22/2023 | 02830 | -replaced tee thermistor for cream
-corrected ped2 issue |
| 791 | Brendan | 08/22/2023 | 04205 | -cleared up ABS leak, replace lines in the 3 line water python and reinsullated |
| 790 | Brendan | 08/21/2023 | 10544 | -rebuilt present window. New parts, now fully functioning.
-troubleshooted qing oven. Loose wire, tightened up.
-recrimped cbb bump bar connector and replaced bump bar
-got all printers (minus grill working) |
| 789 | Brendan | 08/21/2023 | 04205 | -gnats
-replaced ABS drain pan, index sensor, thru beam sensor, superseal kit.
-investigated low water pressure issues. Plugged quad filter. Bypassed. Pre filter bowl cracked. New one on order. Shutoff stuck closed going to quad filters. Replaced. |
| 788 | Brendan | 08/19/2023 | 18198 | -new SSD and reimage pos1 |
| 787 | Jim | 08/18/2023 | 12272 | - cleared frappe machine drain
- built new lower hinge pin on espresso machine door
- installed new sink drain next to prep table |
| 786 | Jim | 08/18/2023 | 00596 | - Exterior door handle broken off door, sourced new screws and refastened
|
| 785 | Jim | 08/18/2023 | 10544 | - Picked up repaired mirror and re installed in men's room
|
| 784 | Jim | 08/17/2023 | 10544 | - Replaced ceiling tiles in kitchen area
- Remounted black spacer behind fixed bench seats
- Installed freezer door closer
- Filled potholes in parking lot |
| 783 | Brendan | 08/17/2023 | 04956 | -replaced temp probe fry vat 3
-replaced bulk ice bin door and gasket |
| 782 | Brendan | 08/17/2023 | 10544 | -ped11, just needed reboot
-McDonalds free wifi, modem became unplugged
-installed delivery monitor
-corrected backfeed settings on receipt printers
-quoted for present window repairs. Needs almost all new innards. On order.
-repaired milk dispenser, pincher came loose from the plunger |
| 781 | Brendan | 08/17/2023 | 10544 | -ped11, just needed reboot
-McDonalds free wifi, modem became unplugged
-installed delivery monitor
-corrected backfeed settings on receipt printers
-quoted for present window repairs. Needs almost all new innards. On order. |
| 780 | Brendan | 08/17/2023 | 02038 | -Troubleshooted ABS extractor error. syrup leaving sensor open. Cleaned out syrup from lift cylinder, and cleaned connector.
-Investigated water under ABS. A few things, a missing syrup deflector which I replaced on site. ABS drip tray needs replacing, as well as a part for ice machine so water doesn't leak out of it. All on order. Also cleaned cold pan drain for good measure. |
| 779 | Brendan | 08/17/2023 | 00596 | -replaced bottom heating element in muffin toaster. Calibrated all set now
-recrimped rj11 on hotg bump bar |
| 778 | Brendan | 08/17/2023 | 04205 | -removed more rocks from ABS. Ran water and removed again to confirm no more rocks were running through
-planned for gnat issue, moved table over |
| 777 | Jim | 08/16/2023 | 10544 | - completed curbing repair
- reinstalled chrome door trim to left side of rear door
- repaired fry storage freezer hinges ( replaced bushings )
- reinstalled door trim to rear door |
| 776 | Jim | 08/15/2023 | 10544 | - replaced multiple ceiling tiles in kitchen area
- installed new cover for 30 amp hanging plug
- Adjusted fryer station door and reinstalled
|
| 775 | Brendan | 08/15/2023 | 04956 | -RHS 2016
-changed KVS 6 and 7 to standardize naming conventions
-fixed door not shutting properly
-replaced hinges on ice machine. Alas it needs new door. On order |
| 774 | Brendan | 08/15/2023 | 02038 | -replaced inlet solenoid @ bulk ice. Watched for cycle to verify
-fixed kiosk issue causing lines in the screen |
| 773 | Brendan | 08/15/2023 | 00596 | -replaced dead top element and calibrated muffins and bagels. I did notice a dead bottom element as well. On order will be back. Should be able to get by with it for now |
| 772 | Brendan | 08/15/2023 | 21582 | -replace breakaway cable PED13 |
| 771 | Jim | 08/15/2023 | 10544 | - replaced multiple ceiling tiles in kitchen area
- installed new cover for 30 amp hanging plug
- Adjusted fryer station door and reinstalled
|
| 770 | Brendan | 08/14/2023 | 02830 | -troubleshooted FFLS, fried board, replaced print mech all set
-troubleshooted 1st window air curtain. NTF |
| 769 | Brendan | 08/14/2023 | 04205 | -troubleshooted coffee brewers. Recalibrated left brewer. Right brewer missing sprayhead. Replaced and calibrated
-troubleshooted printer. It was unplugged.
-adjusted door closer clasp on walk-in door |
| 768 | Jim | 08/14/2023 | 10544 | - Mounted men's room soap dispenser
- Re installed the letters for crispy fries sign
- Cut up old fence pieces
- Removed sign with stickers on it on the drive through side wall
- Removed black frame on outside wall
- started on Drive thru curb repairs
|
| 767 | Brendan | 08/14/2023 | 00596 | -diagnosed muffin toaster, wired wrong causing 3 elements to die. New on order.
-looked at lobby ice, ice gate was stuck. Should be all set
-looked at back door issues. Rim strike not aligned properly, resecured and aligned |
| 766 | Brendan | 08/14/2023 | 21582 | -replaced PED14
-corrected issue with heat table not turning on
-replaced HLZ fuse |
| 765 | Waylon | 08/14/2023 | 07417 | -Leak under abs (I snaked 25 feet down, ran two clean cycles on ice machine, and made sure all hoses were in the drain)
-Leak in frappe machine (emptied drain pan and cleared drain line)
-Leak under sink hand wash behind abs (tightened fittings on top and bottom of u bend pvc) |
| 764 | Jim | 08/11/2023 | 17371 | - Installed white fence post & 4 Rails plus three caps
- Built and installed aluminum filler to prevent nuggets from falling between the fridge and fryer
- Replaced O-ring on hand sink drain |
| 763 | Waylon | 08/10/2023 | 25383 | -Cracked tile in first drive thru broke up sand down mastic and grouted all today
-Installed new window tint for first drive thru window
-Took apart ice machine to install plastic border on ice bin |
| 762 | Jim | 08/10/2023 | 02830 | - Re - set lane one drive thru over height bar
- Repaired fryer drain pan leak |
| 761 | Jim | 08/10/2023 | 10544 | - installed new fence section and end post |
| 760 | Brendan | 08/10/2023 | 10622 | -installed muffin toaster service kit; new top elements and chain
-repaired dish sprayer
-bent back safe lock clasp |
| 759 | Jim | 08/09/2023 | 00596 | Cleared frappe machine drain |
| 758 | Jim | 08/09/2023 | 12272 | - replaced basin sink
- replaced multiple ceiling tiles in lobby area
Grouted floor area around basin sink
- replaced O-ring on right hand sink |
| 757 | Jim | 08/09/2023 | 12272 | - replaced basin sink
- replaced multiple ceiling tiles in lobby area
Grouted floor area around basin sink |
| 756 | Brendan | 08/09/2023 | 02830 | -replaced oven contactor and crimp. All set
-fixed two printers |
| 755 | Brendan | 08/09/2023 | 00596 | -nuisance visit: front ice machine NTF, McFlurry spinner not plugged in NTF, BIM drain Jim did earlier |
| 754 | Brendan | 08/09/2023 | 07194 | -troubleshooted ABS lift arm. Bad lift cylinder. replaced.
-installed filet steamer filter bowl
-tried to replace chain on dt window but new one didn't include spring |
| 753 | Brendan | 08/08/2023 | 02038 | -replaced side 1 breakfast monitor
-diagnosed tea brewer. Bad board/triac. Replaced probes for good measure. On order |
| 752 | Brendan | 08/08/2023 | 07194 | -replaced ABS umbilical
-troubleshooted leaky coffee brewer, bad solenoid |
| 751 | Brendan | 08/08/2023 | 18198 | -replaced kiosk controller
-replaced present monitor mirror |
| 750 | Jim | 08/08/2023 | 12272 | -Sourced and installed multiple ceiling tiles in lobby area
- sourced parts to install new basin sink |
| 749 | Waylon | 08/08/2023 | 02830 | -HLZ need new cord COULDNT find tripped breaker Brendan talked me through funding the secret panel ''?? |
| 748 | Waylon | 08/08/2023 | 07194 | -Replaced water fill solenoid on coffee brewer was leaking
-Started to work on abs found co2 leak was the cord that goes to the cup arm ( had a decent sized cut in it)
-Replaced a ceiling tile that was water damaged in lobby (cut to fit) |
| 747 | Brendan | 08/08/2023 | 18198 | -replaced kiosk controller
-replaced present monitor mirror |
| 746 | Waylon | 08/07/2023 | 07417 | -Drain was clogged (only barbecue packet'.) also added a line to one of the drains that wasn't in line with the main drain |
| 745 | Jim | 08/07/2023 | 17371 | - picked up and dropped off fence post
- cleared men's room urinal drain
Cleared frappe machine drain
- right rear sink needs detente for drain stop Won't stay closed
Replaced spark plug and primed carb on power washer ( works fine)
|
| 744 | Jim | 08/04/2023 | 07194 | Replaced motor and pump on pitco fryer |
| 743 | Jim | 08/03/2023 | 10544 | Replaced 80 floor tiles in front area |
| 742 | Waylon | 08/07/2023 | 10544 | -Fixed oven outlet and cord was fully melted and had to cut some slack from cord (Tripped breaker had to search through to find it)
-Replaced tiles in the crew room that were water damaged and popped a couple around the store back in place
|
| 741 | Waylon | 08/07/2023 | 07194 | -Co2 leak on abs turn off valve wasn't working so on control board turned the co2 regulator down to 0 Brendan will be here tomorrow to fix until then they can manually do sodas |
| 740 | Brendan | 08/04/2023 | 25383 | -replaced two printers
-installed printer side 2 |
| 739 | Brendan | 08/04/2023 | 07194 | -multiplex creating flood; bad oring. Sacrificed filet steamer for now |
| 738 | Brendan | 08/03/2023 | 07417 | -replaced cherry FCB syrup solenoid
-troubleshooted ABS not dispensing soda water, broken spring, replaced all set.
-installed leg on OJ
-troubleshooted flood under ABS, slow drain, will have Waylon come and snake next visit |
| 737 | Waylon | 08/03/2023 | 04956 | -Fixed UHC cabinet 2 button was held down on the bottom strip so replaced strip and replaced display board kne cause originally thought that was bad |
| 736 | Waylon | 08/03/2023 | 10544 | -wormy problems
-helped Brendan with bad water tank |
| 735 | Brendan | 08/03/2023 | 02830 | -troubleshooted oven, bad contactor, on order
-troubleshooted lobby ice dispenser. Ice machine was turned off, turned back on and monitored, dropped a few sheets just fine. Dispenser working as well. No trouble found.
-fixed zoom timer, loose HDMI |
| 734 | Brendan | 08/03/2023 | 02038 | -went to change bulk ice inlet solenoid, I ordered 120v instead of 240v my bad. Unfortunately it's on backorder |
| 733 | Brendan | 08/03/2023 | 10544 | -worms: the sequel '?
-partial printer refresh
-replaced permeate tank
-replaced dish sprayer hose |
| 732 | Waylon | 08/02/2023 | 04956 | -Diagnosed cabinet not working at all, found it to be the top display board telling the cabinet it needed to program and due to a daisy link it caused every strip to say that (supposed to pick a board from lees UHC) |
| 731 | Waylon | 08/02/2023 | 10544 | -BIM PM |
| 730 | Brendan | 08/02/2023 | 07194 | -troubleshooted vats not disposing/filtering. Bad pump. On order
-ordered front fridge condenser cover
-set Linda up with MFA for Eid and email
-replaced cup fingers on large cup tube
-adjusted cup sold out sensor @ ABS |
| 729 | Brendan | 08/02/2023 | 02038 | -troubleshooted ice machine leaking. Inlet valve stuck open, new one on order be back tomorrow. Installed a shutoff valve for machine as it didn't have one previously for some reason |
| 728 | Jim | 08/02/2023 | 12272 | - replaced frappe machine water line fittings to fix leak |
| 727 | Jim | 08/02/2023 | 10544 | - Installed two ceiling tiles around ABS system
- helped manager remove flippers on fry loading unit
- had fry door hinge welded on and re- attached door to cabinet |
| 726 | Brendan | 08/02/2023 | 07417 | -stopped in to correct grill programming for eggs, was set to flat, should be clam. Showed Jay how to add/remove for future LTOs |
| 725 | Jim | 08/02/2023 | 10544 | - Installed two ceiling tiles around ABS system
- helped manager remove flippers on fry loading unit
- had fry door hinge welded on and re- attached door to cabinet |
| 724 | Waylon | 08/01/2023 | 04956 | -ice machine PM it literally looks brand new lmao |
| 723 | Brendan | 08/01/2023 | 04956 | -troubleshooted McDonald's free WiFi
-ordered hinges for ice machine
-ordered more ice machine PM stuff |
| 722 | Brendan | 08/01/2023 | 07417 | -finished stripping down left grill and right grill for parts
-programmed new grills with Doug and David
-troubleshooted FCB cherry. Bad solenoid, on order
-attempted to rekey lock cylinder for back door, unsuccessful. On order |
| 721 | Brendan | 07/31/2023 | 07417 | -strip down grill 1 for parts |
| 720 | Jim | 08/01/2023 | 25383 | - re set Drive thru curbing & mortared them together |
| 719 | Jim | 08/01/2023 | 10622 | - sourced and installed new Pressure treated post for bus and RV parking sign
- added grout to front floor area |
| 718 | Waylon | 08/01/2023 | 07417 | -Helped strip grill down for new ones
-Installed mop sink cover so water isn't shooting everywhere
-replaced two paper towel dispensers with touch less ones
-Moved one old paper towel dispensers outback (Keys were all left with Jesse)
-Installed 2 new mist air freshener in the bathroom (1 girls, 1 boys) |
| 717 | Brendan | 07/31/2023 | 17371 | -replaced gearbox sundae side, replaced belts, filled and tested
-crimped smoothie water line |
| 716 | Brendan | 07/31/2023 | 18198 | -troubleshooted 10:1 freezer. Rick issue, store to call |
| 715 | Jim | 07/31/2023 | 10622 | -Removed 9 loose floor tiles in front area
- Cleaned & removed old mastic from floor
- installed 9 new floor tiles
- installed 1' inspection cap on perp sink drain
- dug out 4x6 wood post broken by the plow company |
| 714 | Waylon | 07/31/2023 | 04956 | Look at egg cooker seemed to be working properly so didn't replace the probe
-Looked at fry hopper ran 4 baskets each side was told it stops closing the gate and fries just come out but no problems
-Looked at the ice machine and talked to mike about pming in the next couple days
- order UHC buttons |
| 713 | Jim | 07/31/2023 | 04956 | - removed and repaired mounting bracket for wall hung freezer
And remounted bracket and securely mounted to the wall
Looks like someone pulled on the unit as bracket was bent severely |
| 712 | Waylon | 07/31/2023 | 10544 | -Replaced ice machine part (level probe)
-Replaced oep had to do live so took a lot more time because no breakers are labeled |
| 711 | Waylon | 07/26/2023 | 17371 | -Grouted tile
-Replaced rocker switch
-tried to help diagnose creamer
-Remounted mcflurry
|
| 710 | Waylon | 07/25/2023 | 10622 | Put in new floor and help doing PM |
| 709 | Waylon | 07/24/2023 | 10622 | Ripping up floor tile |
| 708 | Brendan | 07/30/2023 | 07417 | -troubleshooted fryer power issues. Probably water from automister in places it shouldn't be. Tested amp draw at panel and max out at 15amp with filter motor running, within spec. Checked on roof door loose/frayed wires and exhaust component conditions. Also checked at the fryer for loose/frayed wires, filter motor condition. All seemed to check out
-helped install best burger bump bar
-leak under SSBS; clogged ice bin drain. Unclogged should be all set
-troubleshooted lobby ice maker; was giving long freeze err. Reset and seemed to be within spec after watching for a cycle. If continues to give issues store to call rick |
| 707 | Brendan | 07/28/2023 | 02038 | -tried snaking salad drain. No avail |
| 706 | Brendan | 07/28/2023 | 00596 | -replaced sprite pump |
| 705 | Brendan | 07/28/2023 | 21582 | -traced leak under ABS , clogged drain pan, all set.
-replaced regulator @ BIM |
| 704 | Brendan | 07/25/2023 | 10622 | -worms
-waterline replacement
-replaced booster pump
-replaced permeate tank
-BIM PM |
| 703 | Brendan | 07/24/2023 | 10622 | -worms |
| 702 | Brendan | 07/28/2023 | 10622 | -troubleshooted nexeo network. Corrected and called HME, waiting on call back |
| 701 | Jim | 07/28/2023 | 00596 | - filled holes in red wall
- ran washer through cycle , no issues found
- Installed support under fryolator |
| 699 | Jim | 07/26/2023 | 10622 | - Regrouted floor area and re set three floor tiles |
| 698 | Jim | 07/25/2023 | 10622 | Completed the 90 sq ft area and reset all equipment in area |
| 697 | Jim | 07/24/2023 | 10622 | - removed and replaced approximately 90 sq feet of floor tile in present area
|
| 696 | Brendan | 07/21/2023 | 10622 | -replaced exhaust fan belts for grill fryer and grills
-worm cleanup |
| 695 | Brendan | 07/21/2023 | 17371 | -diagnosed shake machine issues. Bad gearbox on soft serve side. On order |
| 694 | Brendan | 07/21/2023 | 18198 | -emergency call for water line exploded, store without drinks. Replaced defective water line.
-while water was off I replaced defective booster accumulator tank |
| 693 | Waylon | 07/21/2023 | 12272 | -Fixed hand wash timer (old one they like it) had to rewire it and the cord was frayed so I patched up with electrical tape and tried to secure it so the cord wouldn't have loose wires and shock someone
-Grouted the tiles from the other day
-Cleaned bottom of ice machine outback filled with trash from Adam cleaning it |
| 692 | Waylon | 07/21/2023 | 07417 | -Ceiling tile in office
-Moved two paper towel dispensers
-Rewired cord for freezer 10:1 |
| 691 | Jim | 07/21/2023 | 10544 | - Replaced floor tile in front of shake machine
- installed access door under front sink
- cut and installed steel cover for hole in wall under sink
- foamed all openings around panel under sink
- Grouted front floor area at skate machine and present area |
| 690 | Jim | 07/20/2023 | 10544 | - Removed and installed ten floor tiles in front of rear door
- Replaced two floor tiles at Drive Thru
- Replaced two floor tiles in front of sink
- Foam behind white tile wall and mounted new tile
- foamed hole under sink and installed two baseboard tiles
- replaced four casters on present table |
| 689 | Jim | 07/20/2023 | 10544 | - Removed and installed ten floor tiles in front of rear door
- Replaced two floor tiles at Drive Thru
- Replaced two floor tiles in front of sink
- Foam behind white tile wall and mounted new tile
- foamed hole under sink and installed two baseboard tiles |
| 688 | Brendan | 07/20/2023 | 18198 | -attempted to repair filter, unsuccessful. Some plastic parts were seized on, have to order replacements for those as well
-repaired ABS flavor display, new bezel, nuts, and decal |
| 687 | Brendan | 07/20/2023 | 12272 | -replaced milk dairy door
-fixed two issues with dish sink, cold water not turning off and not switching between sprayer and faucet. Both fixed with new faucet washers in the cartridge |
| 686 | Waylon | 07/20/2023 | 17371 | -Installed 7 new tiles (need to sit for 24 hours than grout)
-Fixed GFCI just a tripped breaker ( after taking it apart )
-Worked on lobby shade the one I bought doesn't fit seems to be a custom one (told Brendan)
-Used cement caulking filler on the picnic tables where ever there was some crack (definitely not a concern of it breaking, but it was on the list)
-Hung up board on wall next to freezer
-Installed McCaf?? spoon holder |
| 685 | Brendan | 07/20/2023 | 04956 | -replaced power switch on pie merchandiser
-reattached chain to present window and adjusted to prevent future instances
-relocated delivery monitor setup
-fixed McCaf?? printer not printing
- troubleshooted some fryers. No trouble found.
-troubleshooted egg cooker error. Bad probe. On order |
| 684 | Waylon | 07/20/2023 | 17371 | -Installed 7 new tiles (need to sit for 24 hours than grout)
-Fixed GFCI just a tripped breaker ( after taking it apart )
-Worked on lobby shade the one I bought doesn't fit seems to be a custom one (told Brendan)
-Used cement caulking filler on the picnic tables where ever there was some crack (definitely not a concern of it breaking, but it was on the list)
-Hung up board on wall next to freezer
|
| 683 | Brendan | 07/19/2023 | 10544 | -troubleshooted filet steamer. Bad OEP, on order
-troubleshooted co2 leak. Leaky check valve in multiplex. On order |
| 682 | Waylon | 07/19/2023 | 12272 | -Replaced 1 lobby light ballast
-Replaced 4 light bulbs for lobby lights
-Grouted tiles in front drive thru window
-Liquid nails siding of fc (next to BiM)
-Broke up rest of tiles near freezer window
-Installed 4.5 tiles around freezer window baseboard they still need grout but mastic needs to sit for 12 hours minimum (all cut to fit tiles) |
| 681 | Waylon | 07/19/2023 | 12272 | -Replaced 1 lobby light ballast
-Replaced 4 light bulbs for lobby lights
-Grouted tiles in front drive thru window
-Liquid nails siding of fc (next to BiM)
-Broke up rest of tiles near freezer window
-Installed 4.5 tiles around freezer window baseboard they still need grout but mastic needs to sit for 12 hours minimum |
| 680 | Jim | 07/19/2023 | 10544 | - Grouted sink area floor and replaced two floor tiles
- Grouted crew room corner base tiles, also replaced one baseboard tile |
| 679 | Jim | 07/19/2023 | 12272 | Adjusted and retightened women's handicap toilet |
| 678 | Jim | 07/19/2023 | 10544 | - Steam clean sink area floor
- troubleshoot ice maker had to do a manual harvest and re- set thickness sensor
|
| 677 | Brendan | 07/18/2023 | 12272 | -replaced grill printers
-reimaged pos1 with new SSD
-troubleshooted sugar dispenser. Bad touch panel, now one on order as well as missing feet and Splenda tube |
| 676 | Brendan | 07/18/2023 | 00596 | -adjusted dt fridge hinges to get rid of gap
-cleared SSBS drain
-looked at men's room door. I'll try to get a reinforcer and hope that works |
| 675 | Brendan | 07/18/2023 | 17371 | -repaired BIM; replaced rinser armature and inlet hoses
-repaired coffee pot; new water spout and water line
-repaired filet steamer; replaced regulator assembly
-troubleshooted ABS ice maker. Throwing refrigeration error. Reset the error, if it continues store to call Rick |
| 674 | Brendan | 07/18/2023 | 10622 | -troubleshooted chicken fryer exhaust not working. Snapped belt. Was able to pick up a temporary one, not oil resisted. New belt on order
-also noticed the French fryer exhaust has a worn belt, also preventatively ordered belt
-looked into worms at ABS '?. Nothing I can do on my end
-partial printer refresh |
| 673 | Jim | 07/18/2023 | 10544 | - Installed new safety chain for small CO2 tanks
- Mounted new mop hanger above slop sink
- replaced slop sink hose
- replaced 1 base, 1 floor, and 4 wall tiles, need to grout
- helped Waylon empty ice bin |
| 672 | Brendan | 07/14/2023 | 07417 | -troubleshooted detex. Unable to repair, ordered new mortise cylinder
-troubleshooted ABS ice gate. No trouble found
-repaired muffin toaster fan not working |
| 671 | Jim | 07/17/2023 | 04205 | -Replaced three floor tiles near second drive thru
- replaced three baseboard tiles near walk-in
- Cleared drain at ABS system
|
| 670 | Waylon | 07/17/2023 | 21582 | -Installed new light lense
-Lofted ceiling back on to grid |
| 669 | Waylon | 07/17/2023 | 21582 | -Clogged drain had to auger |
| 668 | Jim | 07/17/2023 | 04205 | -Replaced three floor tiles near second drive thru
- replaced three baseboard tiles near walk-in |
| 667 | Jim | 07/14/2023 | 04205 | - Sourced and replaced flush handle on women's room small toilet and new seat
- Replaced s door handle on exterior door
- Adjusted left sink hot water in ladies room |
| 665 | Brendan | 07/14/2023 | 07194 | -repaired bun toaster fan, brushing up against case, added washers to fix.
-repaired lobby ice not stopping. Button sticky, removed rubber that was getting caught.
-repaired all grill printer issues. Lots of wires not connected to the right places |
| 664 | Brendan | 07/14/2023 | 21582 | -repaired Diet Coke, new quick connect |
| 663 | Brendan | 07/14/2023 | 00596 | -put oven handle and latch back together and adjusted. Should be ok for now. May order new latch just in case |
| 662 | Brendan | 07/14/2023 | 04205 | -reimage pos1 with new SSD
-got a few printers working
-trohbleshooted oven not cooking pies. Oven is actually fine, timer is bad. New one on order. |
| 661 | Brendan | 07/13/2023 | 10622 | -repaired McCaf?? fridge door
-replaced Curtis coffee brewer tank, replaced water lines, flushed new tank, and calibrated. Water running crystal clear now. |
| 660 | Jim | 07/13/2023 | 00596 | Lobby ice machine, no ice, cleared blockage and ran through several cycles works fine now |
| 658 | Jim | 07/13/2023 | 02830 | Called back for men's room TP dispenser, fixed issue |
| 657 | Brendan | 07/09/2023 | 17371 | -diagnosed BIM with multiple leaks. ordered new drain hose, dispense armature, co2 and water hoses.
-checked ABS that wouldnt grab cups. due to no co2 at the time.
-diagnosed coffee brewer. bad water valve, on order.
-transported backup co2 tank from lee |
| 656 | Waylon | 07/13/2023 | 10544 | -Took apart Qing oven was reading Door needed a new switch went to replace just to find out the old switch had one wire disconnected causing it to not work ''?? |
| 655 | Jim | 07/13/2023 | 02830 | -Grout rear floor up to first drive up
-Replaced three baseboard tiles at rear door
- Reset hose connection for new washer |
| 654 | Jim | 07/13/2023 | 02830 | Cut and installed two pieces of sheet metal to cover cup holes up front
Work on trying to get washing machine to work
Installed six lite bulbs in freezer and helped Waylon with the ballast replacement |
| 653 | Jim | 07/12/2023 | 00596 | Went to pick up something or hooksett and the lobby ice machine started to dump ice and I troubleshooted it and reset it ,cup bar was frozen open |
| 652 | Jim | 07/12/2023 | 02830 | Installed two rear wheels on grill
Chained CO2 tanks
Installed weather strip on rear door |
| 651 | Waylon | 07/13/2023 | 02830 | -Tighten washer fitting (was leaking)
-Grouted by the mop sink had to regrout three times due to people dumping water all over it ''?? should've done it last night lol |
| 650 | Waylon | 07/12/2023 | 02830 | -Cleaned lobby ice machine PM (Removal of all ice by hot water )
-replaced two cabinet strips
-Fixed cabinet strips turning off and on
-Replaced washer machine with Brendan
-liquid nails to trash can strip in lobby
-Cleaned out right ice machine hasn't been working so just cleaned exterior parts that were moldy
-Fixed freezer ballast
-Installed freezer lights
-Fixed abs cover not on properly
-Repaired drain pan for lobby soda -Flex seal might not hold takes 24 hours to cure
|
| 649 | Jim | 07/11/2023 | 02830 | - Replaced main entrance threshold
- Installed new safety plate
- replaced two freezer curtains
- installed new rear sink faucet pipe wall bracket
- installed new sink spray holder
- reset washer |
| 648 | Jim | 07/10/2023 | 02830 | - replaced two wheels on rear grill
-Installed mop hanger over slop sink
- clear rear sink drain
- replaced lite in front of the office
- reset washer |
| 647 | Jim | 07/07/2023 | 02830 | - cut and replace multiple ceiling lite panels
- troubleshoot ceiling lite in front of office ( need new fixture)
|
| 646 | Brendan | 07/11/2023 | 02038 | -troubleshooted OJ. Turns out just a whole case had bad nozzles
-bypassed ice lid sensor on BIM
-repaired hi c in lobby, loose wire to water button
-repaired rootbeer in lobby, replaced microswitch |
| 645 | Brendan | 07/11/2023 | 02830 | RGR prep
-replaced limit switch for air curtain
-replaced board in UHC
-helped replace COD cladding
-diagnosed multiplex, needs new IBC
-looked for co2 leak, inside the multiplex, will repair during a morning
-crimped co2 alarm wires together, tested
-BOS 2016
-reattached ABS condenser cover
-reattached base station covers
-corrected issue with deliver monitor
|
| 644 | Waylon | 07/10/2023 | 02830 | -Cleaned out back ice machine PM (Removed all ice, Ran 3 runs of cleaner,Wiped out top and bottom, removed parts and cleaned, ran through two ice cycles then trashed that ice in case any cleaner got on it
-Replaced two UHC strips |
| 643 | Waylon | 07/10/2023 | 18198 | Was Told OJ machine wasn't working (no power going to the unit) just switched outlets no idea how long it's been off for |
| 642 | Brendan | 07/08/2023 | 02830 | -troubleshooted back door air curtain, bad limit switch. On order
-troubleshooted UHC dead. Bad power supply board, on order.
-replaced coffee brewer heating elements |
| 641 | Brendan | 07/08/2023 | 10622 | -troubleshooted Curtis coffee brewer leaking. Cracked tubing, replaced. Water coming out black due to a bad tank, new one on order. Cleaned up level probe as well. Noticed water in tank was boiling so lowered temp a bit.
-replaced probe and hot water valve on bunn coffee brewer
-ordered hinge for McCaf?? fridge
-replaced cbb monitor |
| 640 | Brendan | 07/07/2023 | 02830 | -RHS 2016
-cleaned out boxes from crew room
-sweetener upgrade
-printer fixes
-verified COD in corral is correct |
| 639 | Brendan | 07/08/2023 | 18198 | -replaced rootbeer bib pump |
| 638 | Brendan | 07/07/2023 | 04956 | -repaired water line in multiplex that blew off |
| 637 | Jim | 07/06/2023 | 21582 | - Removed and replaced all weather strip on rear door along with sweep |
| 636 | Jim | 07/06/2023 | 04205 | - rear door weather strip replaced
- checked plug by the Clean dish rack - no issues
- cleared frappe floor drain |
| 635 | Jim | 07/06/2023 | 02830 | - repaired seat base in lobby
- adjusted new prep table for height
|
| 634 | Jim | 07/05/2023 | 02830 | - Grout tiles around building
- Installed two baseboard tiles next to walk-in and grouted them
- Sourced and picked up new prep table to replace the old freezer unit
- checked power switch on UHC unit - no issues
- plugged wires inside fry freezer
|
| 633 | Brendan | 07/06/2023 | 21582 | -Troubleshooted no diet soda. Usual case of a bad quick connect fitting. Will need to order
-checked brix on blue fanta, was fine. If motor stalls continue store to call coke inter warranty. |
| 632 | Brendan | 07/06/2023 | 00596 | -looked for leak under ABS, found ice machine still leaking'
|
| 631 | Brendan | 07/06/2023 | 12272 | -replaced egg cooker OEP, however it needs a new receptacle, on order.
-replaced two ballasts in women's room
-repaired lobby hi c valve, new armature tip and solenoid |
| 630 | Brendan | 07/06/2023 | 07417 | -dropped off multiplex compressor for Rick
-rebooted kiosk ped that was frozen |
| 629 | Brendan | 07/05/2023 | 04956 | -repaired OJ machine, latch stuck in closed position so kept locking out on high temp
-repaired lobby stool that fell off. It fell off because it was held in place with really tiny screws'
-investigated ABS leaking underneath. Cleaned out cold plate drain, was pretty clean so I believe it's a cracked drain pan. New one on order.
- ordered switch for pie merchandiser |
| 628 | Jim | 07/03/2023 | 02830 | - multiple broken tiles around the building have been replaced
- walk in door top latch re-secured
|
| 627 | Brendan | 07/03/2023 | 10544 | -repaired BIM co2 leak and water leak
-replaced 6 bump bars |
| 626 | Brendan | 07/03/2023 | 07194 | -investigated frappe leak; coming from overflowing evap drain pan, dried out. Most likely due to worn gasket. Store to replace gasket. If continues store to call Taylor for refrigeration issue.
-troubleshooted hi-c issue in lobby. Bad shutoff valve. On order.
-replaced HLZ side 2 computer
-corrected issue with prep fridge leaking water, cut back linked drain line and installed a tee. Store will need to defrost overnight to clear up drain pan.
-corrected issue with merge cameras, camera frozen, needed reboot |
| 625 | Brendan | 07/03/2023 | 18198 | -troubleshooted OJ weak taste. Needs calibration, but will not calibrate up to spec. Sanitized lines, cleaned dispense valve components. Needs new pump, on order
-fixed issues with grill printers. Someone messed with the wiring |
| 624 | Jim | 06/30/2023 | 00596 | Main ice maker stopped making ice, ran through clean cycle, back operating now. Needs a de-scaling
- added drain line to bottom pipe
- ran washing machine through two full cycles, no issues
|
| 623 | Brendan | 06/29/2023 | 07417 | -OJ machine install and calibration |
| 622 | Brendan | 06/29/2023 | 02830 | -repaired fryer not draining, replaced linear actuator. Gave me a very hard time
-took a shower in vegetable oil. Maybe if I jump in the pool all the oil will float to the top??
-repaired Qing oven, new transformer and magnetron
-troubleshooted coffee brewer not heating. Needs new heating elements, on order.
-replaced dt window chain |
| 621 | Brendan | 06/29/2023 | 02038 | -repaired detex in play place that wasn't arming |
| 620 | Waylon | 06/29/2023 | 07417 | -Replaced two cabinet strips (hour glass) takes longer to take those apart
-Grouted in front of fry hopper
-Replaced 3 fry sockets (Had to redo the wiring and tripped the breaker because my smart self decided that both wires should touch '''''?? anyways worked out fine after I fixed the one socket I crossed wires |
| 619 | Jim | 06/28/2023 | 25383 | - re caulked slop sink
- cleared men's room urinal drain
- replaced two bulb sockets on lite over fry station
- troubleshoot two ice machines one in lobby and one next to sink
Power loss caused them to lockup and had to run through clean cycle to re- set them |
| 618 | Jim | 06/29/2023 | 02038 | - replaced two ceiling tiles
- installed cover on flag pole
- misc items done IE: remove sticker from window, remount exit sign
|
| 617 | Brendan | 06/28/2023 | 00596 | -replaced bnc multiplexer
-fixed receipt printer issues on fc Expos
-investigated leak by ABS. Water coming from ice machine when draining, store to call Rick
-investigated leak by bulk ice, found leaky PVC. Will send Jim out this week |
| 616 | Brendan | 06/28/2023 | 02038 | -printer refresh
-replaced freezer deliver door latch
-adjusted lane 2 volume settings
-replaced two lobby light bulbs
-replaced right side fry hopper motor |
| 615 | Jim | 06/28/2023 | 25383 | - re caulked slop sink
- cleared men's room urinal drain
- replaced two bulb sockets on lite over fry station
- troubleshoot two ice machines one in lobby and one next to sink
Power loss caused them to lockup and had to run through clean cycle to re- set them |
| 614 | Waylon | 06/28/2023 | 17371 | -Abs ice machine PM (Ran clean cycle 3 times chemical got stuck in the side of bin)
-Lobby ice machine PM (Ran clean cycle twice to make chemical was out)
-Replaced HOTG bracket so it no longer tilts |
| 613 | Brendan | 06/28/2023 | 04956 | -called for ABS not giving consistent drink levels. Found sediment in the flow control. Cleaned out and calibrated |
| 612 | Jim | 06/28/2023 | 04205 | - Checked ladies room toilet and found no leaks
- adjusted men's room door closer
- adjusted play place door closer |
| 611 | Brendan | 06/27/2023 | 04956 | -replaced probe on traulsen fridge. Calibrated and needed to defrost evaporator which was all iced up.
-replaced probe on fry/meat freezer, calibrated and defrosted iced up evaporator
-replaced ABS touch panel, whos up button was not working |
| 610 | Waylon | 06/27/2023 | 17371 | -Back ice machine PM |
| 609 | Jim | 06/27/2023 | 25383 | - second Drive thru light ballast replaced
-ABS drain unclogged |
| 608 | Jim | 06/27/2023 | 02038 | - installed nine information boards in crew room
- reattached two multi coat hooks in crew room |
| 607 | Waylon | 06/27/2023 | 02038 | -Abs ice machine cleaning (Super moldy)
|
| 606 | Waylon | 06/26/2023 | 02038 | -Replaced ceiling tiles
-Cleaned 3 ice machine pms
-replaced led light bulb in grill freezer
-Replaced fry socket in fry station (was burning the bulb out instantly)
|
| 605 | Brendan | 06/26/2023 | 02830 | -troubleshooted grill vat 2. Bad linear actuator, on order.
-troubleshooted Qing oven, ordered new transformer and magnetron
-replaced dead HOTG a monitor
-ordered dt window chain |
| 604 | Brendan | 06/26/2023 | 02038 | -installed part in fry hopper, one of them is broken. Need to order replacement.
-troubleshooted right lobby ice machine not filling, stubborn water fill probe, got working
-ordered replacement handle for freezer delivery door |
| 603 | Jim | 06/26/2023 | 00596 | - frappe machine drain line cleared
- re-installed window latch at Drive thru #2
- installed new hand sink faucet |
| 602 | Brendan | 06/26/2023 | 04956 | -troubleshooted traulsen fridge. Bad cabinet probe, on order. Adjusted temp down to hopefully get by until part comes in
-troubleshooted ABS. Put on conveyor, no trouble found
-troubleshooted French fry chest freezer. Bad cabinet probe as well. On order. |
| 601 | Jim | 06/26/2023 | 02038 | Finished outside concrete work |
| 600 | Jim | 06/23/2023 | 02038 | Completed 90% of concrete work |
| 599 | Jim | 06/22/2023 | 02038 | Continue working on outside concrete work |
| 598 | Brendan | 06/22/2023 | 04205 | -troubleshooted shaver/blender comm error at BIM. Loose connection to island oasis board
-set up correct heat mode start time and set clock to correct time and date. had to bypass brush clean to set clock. Set to start heat cycle at 1 and start at 5 |
| 597 | Brendan | 06/22/2023 | 10544 | -repaired BIM, replaced regulator |
| 596 | Brendan | 06/22/2023 | 02038 | -repaired detex at office
-reinstalled detex
-repaired McFlurry blender, replaced momentary switch with more reputable after market button
-'fixed' all kiosk printers. Rolls were all installed backwards.
-repaired freezer door emergency release, cleaned up threads.
-fixed lobby music not working, replaced media player.
-called Rick out to replace freezer heater strip
-further troubleshooting on right side of fry hopper. Ordered door motor/spring and load cell. |
| 595 | Waylon | 06/22/2023 | 17371 | -Temporarily fixed filet steamer was leaking ended up leaking again as I left so had Brendan order a new one
-swapped bump bar cables so HOTG went to HoTG not desert
-Cleaned some boxes out of crew room took in my van extra parts
-cleaned bottom of ice machine right where ice goes to the box was severly molded gonna go back for an ice machine pm when cleaner comes in Friday cause it's BAD including moldy ice cubes |
| 594 | Jim | 06/21/2023 | 02038 | Remove broken concrete around building and install new concrete |
| 593 | Brendan | 06/21/2023 | 04956 | -had to come again for a different unrelated ABS issue. Carb water stuck on. Sediment causing armature to stick open. Cleaned out and replaced armature
-noticed the ABS up button not working, ordered a touchpad
-noticed leaking below ABS, cold plate drains. Unclogged, all set |
| 592 | Brendan | 06/21/2023 | 07417 | -troubleshooted lane 1 unable to hear customer. Checked wiring in COD, all good. Trim pot on the base station board is temperamental, got it stable for now, but am ordering a new board just in case.
-troubleshooted BIM leaking everywhere, found a MASSIVE clog in the drain pan and drain line. Cleared out drain pan and blew out drain line. All set. |
| 591 | Brendan | 06/21/2023 | 04956 | -ABS not grabbing cups. Bad cup crab cylinder. Replaced and calibrated |
| 590 | Brendan | 06/21/2023 | 21582 | -tightened some clamps for sanitizer
-traced electrical issue for automist/hot water circ. Bad breaker. Tapped into another breaker
-helped with shake machine leak, bad door oring
-replaced cotter pin on sanitize lever |
| 589 | Brendan | 06/21/2023 | 10622 | -repaired women's toilet, replaced piston and solenoid
-rekeyed toy merchandiser lock
-found suitable cover for play place slide
-installed new wall in cooler evaporator fan blade
|
| 588 | Waylon | 06/21/2023 | 07194 | -Cleaned abs ice machine PM
-Lobby ice machine PM (couldn't get cover off so sanitized and cleaned the outside to beat I could)
-Grouted tiles by office door |
| 587 | Jim | 06/21/2023 | 10622 | - Installed 2 lobby ceiling tiles, left the rest on the multiplex
- installed washer and nut on play place slide, needs a protective cap |
| 586 | Brendan | 06/20/2023 | 17371 | -troubleshooted freezer tripping. Didn't find any significant issues. Not tripped, down to temp, and stable.
-replaced 3 orings on filet steamer
-replaced walk-in door closer |
| 585 | Waylon | 06/20/2023 | 07194 | -Ice machine outback PM (Took longer cause the drain function wasn't working so had to run extra clean cycles and wait for multiple ice freezes)
-Look at coffee pot was told it was over brewing / 'brewing double pots' ran two cycles both came out fine
-Looked at Hi C in lobby not dispensing soda syrup I think there's a problem somewhere from distributing it cause everything looks fine on the drink station (Replaced armature tips)
-Cut down spray foam and mastic two tiles need to sit for a day then grout |
| 584 | Jim | 06/20/2023 | 10544 | - re- installed rear door crash bar
- patch multiple holes in parking lot
- Reattach stone facing at second drive thru
- Grout second drive thru area |
| 583 | Brendan | 06/20/2023 | 10544 | -diagnosed BIM not dispensing water. Bad water regulator, on order.
-ordered bump bars |
| 582 | Brendan | 06/20/2023 | 07417 | -called for oven not heating. Really easy today, loose wire. Reconnected and came up to temp fine |
| 581 | Brendan | 06/19/2023 | 04956 | -repaired print mechanism for FFLS |
| 580 | Brendan | 06/19/2023 | 00596 | -replaced door handle to men's room
-replaced cord to fridge under prep line
-troubleshooted cabinets overheating? No trouble found
-looked at ice maker out back, all pipes appear to be in place and working
-looked at freezer fan making noise. Coincidentally the freezer fans were the quietist I've heard all day '''''?? |
| 579 | Waylon | 06/19/2023 | 02038 | Replaced a case and a half of ceiling tiles in the gril
-Fixed up the offices grid that was causing the ceiling to cave in
-Replaced light lense that was half dangling out |
| 578 | Brendan | 06/19/2023 | 07194 | -repaired freezer door that fell off
-got IDMB 2 working
-fixed coke valve in lobby, replaced CW armature tip
-corrected RPR2 |
| 577 | Jim | 06/19/2023 | 17371 | - Relocated wire shelf from above sink to above washing machine per health inspector
- Drive they clearance bar reinstalled
- Lifted lobby ceiling above trash bin
- auto mister mounting bracket fell off wall. Was mounted with wrong type of fasteners, bracket is not in store vendor will need to come back to refasten to wall correctly
-first walk-in door latch drilled and tapped, refastened with screws |
| 576 | Jim | 06/19/2023 | 17371 | - Relocated wire shelf from above sink to above washing machine per health inspector
- Drive they clearance bar reinstalled
- Lifted lobby ceiling above trash bin
- auto mister mounting bracket fell off wall. Was mounted with wrong type of fasteners, bracket is not in store vendor will need to come back to refasten to wall correctly |
| 575 | Brendan | 06/19/2023 | 10622 | -diagnosed freezer fan not working. Destroyed fan blade, on order.
-snaked out prep sink drain, should be all set
-ordered changing table for men's room
-ordered rim cylinder for dt side door
-picked toy merchandiser lock to remove for replacement |
| 574 | Jim | 06/16/2023 | 25383 | - ran snake to clear drain found no blockage, did notice white pvc pipe on edge of drain, repositioned to center more. |
| 573 | Jim | 06/16/2023 | 07194 | - Fixed egg cooker outlet, refastened to cabinet
- Tightened ladies room divider
- spray foamed holes in wall to provide substrate for new baseboard tiles
|
| 572 | Jim | 06/16/2023 | 04205 | - Replaced multiple baseboard tiles
- Replaced plug on double fridge relocated glove rack and temp probe bracket
- replaced ballast in light above fry station |
| 571 | Brendan | 06/16/2023 | 04205 | -fixed issue with cbb printer. Cord fell behind machines like I suspected' |
| 570 | Brendan | 06/15/2023 | 04956 | -repaired leak in the multiplex. Two connections on the recirc A pump needed to be redone with new lines. I suspect small leak in the water bath. If leak is significant and still persists new multiplex is advised. |
| 569 | Brendan | 06/15/2023 | 25383 | -partially installed delivery monitor, unable to complete due to missing shelf parts
-looked at leak under coffee maker. I think due to drain line not being in drain
-installed two printers |
| 568 | Jim | 06/15/2023 | 10544 | Finished closing gaps in perimeter fence
|
| 567 | Jim | 06/14/2023 | 10544 | Worked on perimeter fence |
| 566 | Jim | 06/14/2023 | 12272 | Replaced gasket in left sink |
| 565 | Waylon | 06/15/2023 | 10544 | -Perimeter fence
-two new boards and one new post all needed to be dug and trimmed down from original length had to cut multiple new knobs in the sides so it looked proper
|
| 563 | Jim | 06/14/2023 | 02038 | - Grout all re-set tiles
- replaced damaged lobby ceiling tiles
- Installed new TP holder in ladies room toilet
- installed mop holder over slop sink
|
| 562 | Brendan | 06/14/2023 | 02038 | -fixed play place detex. Replaced transformer and corrected settings.
-fixed right side fry hopper. Needed load cell calibration.
-replaced back door security glass
-ordered kitchen ceiling tiles
-ordered emergency release for freezer |
| 561 | Waylon | 06/14/2023 | 10544 | 2 fence post
1 fence panel
|
| 560 | Brendan | 06/12/2023 | 04956 | -fixed printer wiring issues |
| 559 | Brendan | 06/14/2023 | 04956 | -called for fry hopper no power. Loose wire in the back. All set |
| 558 | Waylon | 06/14/2023 | 02038 | -Took apart and cleaned ice machine inside
-Installed 2 double tp dispensers |
| 557 | Jim | 06/13/2023 | 02830 | Repaired corral outdoor faucet
|
| 556 | Jim | 06/13/2023 | 10622 | Cleaned and remounted baseboard tile next to shake machine area
Took one lobby ceiling tile to match and order they will be in Friday 6/16 |
| 555 | Jim | 06/13/2023 | 04205 | Removed small tv from lobby |
| 554 | Jim | 06/13/2023 | 00596 | Removed two small tv's from lobby |
| 553 | Jim | 06/12/2023 | 10544 | Started working on fixing the perimeter fence |
| 552 | Waylon | 06/12/2023 | 07194 | -Replaced sprite pump
-Fixed freezer wall door half hanging off (need a new drill smh)
|
| 551 | Jim | 06/12/2023 | 17371 | - Egg cooker wheel reinstalled
-installed missing screw in prep cabinet
- dish sink soap compartment checked working fine drain handle is new and moves very easily and no leaks
- hand washing sink in grill area not leaking anymore
- curb side signs 5,6 reset further back to eliminate being hit
- removed all tiles in corral
|
| 550 | Jim | 06/09/2023 | 02038 | - Replaced two base tile next to the number 1 Drive thru, four base tiles next to QPC fridge, and 5 floortiles next to delivery door |
| 549 | Jim | 06/08/2023 | 25383 | Removed small tv and cable box from lobby |
| 548 | Waylon | 06/12/2023 | 17371 | -Replaced soda sprite pump |
| 547 | Brendan | 06/09/2023 | 25383 | -replaced tea brewer water line |
| 546 | Waylon | 06/08/2023 | 12272 | -Dug curbside hole
-concrete two curbside poles in
-Concrete the rest of coral poles
-installed new camera for bc
-Took down lobby tv |
| 545 | Brendan | 06/08/2023 | 04956 | -calibrated FCB
-troubleshooted FCB syrup out status issue. Wired backwards. Corrected
-Reimaged pos1 |
| 544 | Jim | 06/08/2023 | 04205 | - dropped off double fridge from Milford
- troubleshoot ABS system, cups would not advance, cleaned cup D sensors and all operational
|
| 543 | Jim | 06/08/2023 | 25383 | - clear floor drain under sink , need 101/2 x 101/2 grate to minimize clogging
- removed double fridge that was not needed |
| 542 | Jim | 06/08/2023 | 02830 | - replaced four bun toaster belts |
| 541 | Jim | 06/07/2023 | 04956 | - replaced center fry socket, wire broke away from connection
- installed crew room mirror
- helped Waylon reconnect fry dispenser cord
|
| 540 | Jim | 06/07/2023 | 25383 | - removed and replaced baseboard tiles by the monitors wall
- replaced 2x4 ceiling lite with LED lenses frame missing on old lite
- removed and replaced baseboard tiles next to walk- in and rear door
- Re-fastened outside door sweep on outside of delivery door
|
| 539 | Jim | 06/06/2023 | 25383 | - replaced multiple ceiling lite lenses
- installed exhaust fan ceiling diverter above Drive thru one
- Steam cleaned top of sink backsplash and re- caulked
|
| 538 | Jim | 06/06/2023 | 02830 | - after signing in the store had no CO2 , I ran to Hanover street and borrowed a small tank |
| 537 | Jim | 06/05/2023 | 25383 | - worked on ceiling lite lenses |
| 536 | Jim | 06/05/2023 | 04956 | - Tried to snake sink drain under multiplex handheld power auger not strong enough
- all fire extinguishers in place
Replaced and grouted two wall tiles next to front register
- installed delivery door sweep
- removed and got rid of old prep cabinet
|
| 535 | Waylon | 06/05/2023 | 04956 | -Fixed cameras
-Dug hole for curbside |
| 534 | Waylon | 06/06/2023 | 12272 | -4/7 corral post reconcreted
|
| 533 | Waylon | 06/07/2023 | 04956 | -Grouted back sink
-Grouted front window along equipment
-Replaced UHC button
-Replaced 2 UHC strips
-Replaced fry hopper cord |
| 532 | Brendan | 06/07/2023 | 02038 | -replaced breakaway cord for ped15. Died due to water damage
-reinstalled delivery monitor equipment and tidied cords
-replaced 1 bump bar
-replaced 2 bump keycaps |
| 531 | Brendan | 06/06/2023 | 07417 | -replaced relay @ egg cooker
-replaced water bath and cabinet temp probes @ OJ. I believe there is a refrigeration issue as well, possibly bad compressor |
| 530 | Brendan | 06/06/2023 | 04956 | -hooked up side 2 breakfast monitor and bump bar
-installed and tan line for side 2 printers
-tidied up wires
-replaced cup fingers @ ABS and adjusted co2 down to spec
-dropped OEP box down to grid
-separated trash cans
-mounted new paper towel holder
-mounted ice bucket hangers
-replaced DP printer |
| 529 | Brendan | 06/05/2023 | 10622 | -reimaged pos1
-fixed IDMB3 not displaying |
| 528 | Brendan | 06/05/2023 | 07417 | -troubleshooted egg cooker not heating well. Bad relay, on order
-corrected water valve in lobby coming out brown, disconnected solenoid
-troubleshooted flat soda. Multiplex not cooling, checked electrics and roof unit, seems to be low on refrigerant. Store to call liquid ice
-ordered water label for lobby valve
-ordered probes for OJ machine |
| 527 | Brendan | 06/05/2023 | 04205 | -blended ice PM training Waylon
-reset error on left coffee brewer, calibrated. Ordered new funnel |
| 526 | Waylon | 06/05/2023 | 04205 | -UHC cabinet strip
-Blended ice machine PM |
| 525 | Jim | 06/02/2023 | 04205 | -Replaced o-ring on flush unit in ladies handicap toilet
- Removed broken toilet ring and replaced , also installed new Wax ring and bolts to secure toilet to floor
- reworked men's room toilet flush pipe to stop leaking |
| 524 | Jim | 06/02/2023 | 07194 | - replaced left side front fry station outlet and plug
|
| 523 | Waylon | 06/02/2023 | 07417 | -Replaced egg cooker cord |
| 522 | Waylon | 06/02/2023 | 02038 | -Snaked drain |
| 521 | Waylon | 06/02/2023 | 07417 | -Installed 2 new cameras and wired
-Set up on monitor in office |
| 520 | Waylon | 06/01/2023 | 12272 | -Installed one new camera up front
-Remounted fire extinguisher
|
| 519 | Jim | 06/01/2023 | 17371 | - Replaced right hand sink drain gasket |
| 518 | Jim | 06/01/2023 | 04205 | - ABS machine had no power, checked cords and it turned on
- frappe machine not working, ran it through a weekly cycle and now works
- men's room toilet pipe repaired |
| 517 | Jim | 06/01/2023 | 07417 | - Replaced sanitize drain gasket and extended open drain to minimize splash over
Checked cold water issue in main sink needs new cold water cartridge
- Hot Water tank mixing valve not adjustable anymore |
| 516 | Waylon | 06/01/2023 | 02038 | -Took old pressure washer returned it bought new
-Set up new pressure washer |
| 515 | Jim | 05/31/2023 | 07417 | - 2 base tiles set and grouted
- 3 egg crate panels cut and replaced
Worked on top hinge of base fridge next to drive thru present window
Door is no longer flat used magnets to hold closed |
| 514 | Jim | 05/31/2023 | 04956 | - Two base tiles , not grouted
One egg crate panel replaced
|
| 513 | Jim | 05/30/2023 | 02038 | - Patch two holes in crew room walls need to be sanded and recoated
|
| 512 | Jim | 05/30/2023 | 04956 | - Replaced fry socket and one bulb
Installed two pipe clamps for drive thru present area ice hopper drain
|
| 511 | Waylon | 05/31/2023 | 17371 | -corral frame fixed
-corral five boards
-Sink clogged and caulked
-abs clogged snakes
-tile behind frappes |
| 510 | Waylon | 05/30/2023 | 17371 | -GFCI outlet
-hand dryer motor
-tile behind shake machine |
| 509 | Brendan | 05/31/2023 | 04205 | -called for ABS drain clog. Cleared the clog, found conveyor belt screw logged in the 90.
-replaced detex battery
-side 1 breakfast bump bar |
| 508 | Brendan | 05/31/2023 | 07194 | -replaced window 2 chain
-troubleshooted vat 1 electrical. Legs all there. Plug is a bit charred so new plug and outlet on order |
| 507 | Brendan | 05/31/2023 | 02830 | -replaced usb cable for side 2 printers. All working now.
-troubleshooted fryer 2 not heating, found breaker to be off.
-replaced dual point printer
-installed eProduction printer |
| 506 | Brendan | 05/31/2023 | 10622 | -unclogged frappe lines. Very stubborn, had to take all apart and blow drain out |
| 505 | Brendan | 05/30/2023 | 04205 | -troubleshooted BIM motor lock error. Shaver blade very dull, new one on order. Got up and running for now |
| 504 | Brendan | 05/30/2023 | 12272 | -repaired tea brewer. Had to makeshift line to connect to pressure switch
-repaired coffee brewer. Replaced fill solenoid and calibrated |
| 503 | Waylon | 05/30/2023 | 18198 | -adjusted coffee brewer brew volume |
| 502 | Jim | 05/26/2023 | 04956 | - Tightened men's room dividers
- Tightened men's room toilet to floor
- Mounted two wire shelves above baking station |
| 501 | Jim | 05/25/2023 | 12272 | - Replaced two Drive Thru base tiles
- Purchased and installed mailbox
- repaired # 1 Drive thru sign
- reset parking signs 3&4
- remounted Ray Kroc plaque in lobby
- checked ladies room handicap pipes for leaks, none found |
| 500 | Brendan | 05/27/2023 | 04956 | -cleaned up wires and tech area in office
-installed eProduction printer
-replaced front counter CLDs
-wired electric for second window |
| 499 | Waylon | 05/26/2023 | 02038 | -Bought new pressure washer took old |
| 498 | Waylon | 05/25/2023 | 07417 | -Caulked back sink
-Rotated fridges out changed outlet (yellow oep) |
| 497 | Brendan | 05/25/2023 | 25383 | -fixed issue with dt cameras. Signal booster on the fritz
-troubleshooted HLZ outlet. Outlet was fine, landing zone needed replacement cord set
-troubleshooted corral breaker tripping. Found a nest in the disconnect box |
| 496 | Jim | 05/24/2023 | 02830 | -replaced 6 drive thru and 4 curbside signs |
| 495 | Brendan | 05/24/2023 | 02038 | -found ground fault with lot breaker
-programmed timer for lights
-showed how to change bun toaster belt
-diagnosed detex, bad tamper switch. Will take to office to repair |
| 494 | Brendan | 05/23/2023 | 00596 | -fixed sodas coming out low. Recalibrated all sodas. Replaced a few parts on the coke valve
-got all menu boards working |
| 493 | Brendan | 05/22/2023 | 10622 | -reimaged pos1
-repaired left Diet Coke valve |
| 492 | Brendan | 05/23/2023 | 07417 | -replaced COD 2 shroud, had to crimp Ethernet cables
-replaced clearance bar lane 1
-replaced window 2 motor |
| 491 | Waylon | 05/23/2023 | 07417 | -Replaced COD with Brendan
-Replaced clearance bar drive thru |
| 490 | Jim | 05/23/2023 | 10544 | - picked up check for fencing
Dropped off check and setup order estimates delivery on either 6/3 or 6/10 |
| 489 | Jim | 05/22/2023 | 10544 | - Work on sourcing parts to replace perimeter fence panels
Got quote from gate city fencing need check |
| 488 | Jim | 05/19/2023 | 02830 | - reset outside railing on Drive thru side |
| 487 | Jim | 05/19/2023 | 02038 | - Replaced stained ceiling tiles in lobby
- troubleshoot lite over washer and replaced bulbs |
| 486 | Waylon | 05/22/2023 | 10544 | -Installed new light
-Fixed a ballast
-Fixed mop sink leaking replaced multiple valves and added new attachments to make everything work normally
-grouted near friers
-Had Brendan order new UHC strips , last ones had the strip on the wrong side
-Qing oven door switches on order too |
| 485 | Brendan | 05/22/2023 | 07417 | -replaced fried products monitor |
| 484 | Waylon | 05/19/2023 | 00596 | Replaced UHC strip |
| 483 | Jim | 05/18/2023 | 07417 | - coordinate with fire marshal to locate and mount exterior fire box to building |
| 482 | Jim | 05/18/2023 | 18198 | -grout under prep sink
- grout tiles around DT present window
- installed missing men's room changing station safety belt
- grout lobby wall tiles
|
| 481 | Jim | 05/17/2023 | 18198 | - replaced missing tile under prep sink
- grout gap on top of baseboard tiles to right of walk-in
Replaced multiple lobby ceiling tiles
- grout menu board wall
- replaced intake vent tiles
- replaced baseboard tiles under DT present window
- reattach emergency lite to ceiling tile above sink
- Fix sink leak
- lower vent above oil tanks to fit in grid
- replaced stock room tiles
|
| 480 | Waylon | 05/18/2023 | 10622 | -medium soda cups were not pulling on the abs replaced side clips all set |
| 479 | Waylon | 05/18/2023 | 04205 | Replaced oven contractor |
| 478 | Waylon | 05/17/2023 | 18198 | -Replaced LED light
-Replaced two light lense
-Put corner trim up spray painted and cut
-Spray paint ceiling vent that was white now black
-Spray paint water marks in lobby ceiling tiles
-Dropped hanging vent into ceiling by oil tanks
-Grouted vestibules tiles
-Grouted lady's room tiles small stall and door
-Grouted right corner of menu board wall
-Replaced emergency light redid all the wiring
-Fixed back stock room tiles were not sitting in grid |
| 477 | Waylon | 05/18/2023 | 18198 | -Fixed loose board behind order points (fallen over)
-Caulked many holes
-Grouted lobby tile
-Egg cooker OEP replaced
-Cleaned up outback of boxes
-Helped put away truck
-Clogged woman's bathroom drain used my co2 pump and blasted it out then cleaned the woman's bathroom cause it went everywhere |
| 476 | Waylon | 05/16/2023 | 18198 | -Fixed 3 cabinet strips
-Replaced a whole display board |
| 475 | Waylon | 05/16/2023 | 25383 | -Replaced a probe on the multiplex (Brendan's first diagnose)
-Kept looking I finally diagnosed with bad motor (called coke) |
| 474 | Waylon | 05/16/2023 | 18198 | -Yellow OEP
-Broke up 4 tiles out back for Jim
-Grouted corner of Sam wall and fixed tile |
| 473 | Waylon | 05/17/2023 | 10622 | Sprite pump replaced - working ran through line a little (a crew said it was a little watery so ran it through like more should be all set) |
| 472 | Jim | 05/16/2023 | 18198 | - Installed two baseboard tiles in walk-in
- trim lite defuser and installed
- prep and install 4 baseboard tiles along back wall next to oil tanks
- cut remaining corral boards
- loaded 24 -6'X 6' PT boards to store in office
- Prep baseboard tiles in first DT side vestibule
Installed safety chains to secure CO2 tanks
|
| 471 | Brendan | 05/15/2023 | 07194 | -replaced filet steamer regulator
-removed broken chain from window 2. New chain on order |
| 470 | Brendan | 05/15/2023 | 00596 | -fixed delivery printer. Tripped plug |
| 469 | Brendan | 05/15/2023 | 18198 | -repaired hinge on prep door fridge
-took stuff back from the attic |
| 468 | Jim | 05/15/2023 | 07417 | - took double fridge from Lee to Epping |
| 467 | Jim | 05/15/2023 | 18198 | - Installed freezer curtain on inside of exterior door
- R&R two broken baseboard tiles under back room rack
- Replaced safety cap on blue overhead outlet
Grout men's room wall tile next to door stop
- Applied contact cement to bottom of lobby tables
- R&R two broken lobby floor tiles |
| 466 | Waylon | 05/15/2023 | 10622 | -Replace bun toaster fan
-Replace light ballast by friers |
| 465 | Jim | 05/12/2023 | 18198 | - grout all replaced tiles
- Installed new freezer door gasket
- Repaired dish sink leak
|
| 464 | Jim | 05/11/2023 | 18198 | - Cut multiple boards for corral
Cut and fir corner trim around store |
| 463 | Jim | 05/10/2023 | 18198 | - Removed and replaced baseboard tiles around store
- helped Waylon replace flush head on men's urinal |
| 462 | Brendan | 05/14/2023 | 18198 | -rewired music system
-troubleshooted lobby emergency light. New fixture on order
-replaced pos13 with new one
-swapped back pos15 and pos1
-reimaged pos1 |
| 461 | Brendan | 05/14/2023 | 17371 | -troubleshooted women's room hand dryer not working. Ordered new motor
-replaced frappe water line that was leaking |
| 460 | Brendan | 05/14/2023 | 10622 | -called for co2 leak. Bad sprite pump. Don't have any more on me, on order
-tried to clean but toaster fan, no luck. Waylon will be by to replace in the morning |
| 459 | Brendan | 05/12/2023 | 18198 | -installed eProduction printer
-traced issue with speaker system. It's a big mess. I will run new wire next time |
| 458 | Brendan | 05/12/2023 | 07194 | -looked at filet steamer leaking, needs new regulator, on order
-adjusted hinge catch @ walk-in fridge |
| 457 | Brendan | 05/12/2023 | 00596 | -replaced armature and solenoid Fanta ABS
-tightens ABS cup
-ordering new multiplexer for dt cameras
|
| 456 | Brendan | 05/11/2023 | 17371 | -replaced fry station switch with Hubble heat resistant one
-reimaged pos1 |
| 455 | Brendan | 05/12/2023 | 18198 | -cleaned out fridge full of my parts
-replaced all grill printers with new Epsons. Installed new AB boxes.
-replaced all grill bump bars
-repaired kitchen emergency lights |
| 454 | Brendan | 05/11/2023 | 07417 | -replaced heating element grill vat 1
-replaced contactor vat 3
-a bunch of connectors disintegrated and a probe needs to be replaced. Casco will have to finish up while I'm on vacation |
| 453 | Waylon | 05/11/2023 | 18198 | -Started with men's urinal was leaking from the top, disconnected everything to isolate the leak. Jim had an extra one in his van so took that and replaced it
-replaced multiple corner board trims throughout store they just need one in the office and above back cash window
-Worked on corral got all the boards cut to fit just waiting on my van to get back to get the big self tappers
-Took down 8 tiles out back by the buggie had to sand all the old mastic off and remastic them cause they were patruding from the wall |
| 452 | Brendan | 05/10/2023 | 07417 | -diagnosed grill vats 1 and 3. Vat 1 needs a new heating element. Vat 3 needs a new heat contactor. Also need to fix the botched job casco did. Parts on order |
| 451 | Waylon | 05/09/2023 | 18198 | -Put two camera covers on
-Installed 2 cameras
- Had bun toaster over heating took out a screw and let some heat out because of bad fan
-Put in two display boards for side 2
-Caulked multiple holes by dish sink and behind dish rack
- put up 2 corners board dt window 1
-Put up top corner board out back by back door
-Assisted Brendan on letter board removal take down |
| 450 | Brendan | 05/09/2023 | 18198 | -printer refresh, new Epsons
-traced breaker for letterboard, removed and disposed.
-staged new register |
| 449 | Jim | 05/09/2023 | 07417 | - replaced hand sink faucet next to rear dish sink
- reattached corral door panel |
| 448 | Jim | 05/09/2023 | 04205 | - replaced weather strip on rear door
- foamed side door frame, need to bondo |
| 447 | Jim | 05/09/2023 | 02830 | - Troubleshoot automatic faucet, batteries we're starting to corrode, replaced batteries works fine |
| 446 | Brendan | 05/09/2023 | 12272 | -repaired one side of tea brewer. Waiting on parts for other side
-fixed issue with pos15 |
| 445 | Brendan | 05/09/2023 | 04205 | -reimaged pos1
-frappe spinner wasn't working because the water wasn't plugged in' |
| 444 | Jim | 05/08/2023 | 18198 | - Removed and replaced multiple baseboard tiles
- replaced 6 egg crate ceiling panels
- Grouted previously replaced tiles |
| 443 | Brendan | 05/08/2023 | 00596 | -unclogged ABS drain. Bought co2 drain opener, showed store how to use for next time |
| 442 | Brendan | 05/08/2023 | 02038 | -replaced cooling coil and agitator motor @ multiplex
-eProduction install |
| 441 | Waylon | 05/08/2023 | 02038 | All eproduction complete on my end |
| 440 | Jim | 05/05/2023 | 00596 | - Reset floor tiles by sink and grouted area
- Worked with Waylon to lift and secure sagging ceiling in two places
- Installed vent cover at base of QPC fridge
- Cleared ABS drains |
| 439 | Waylon | 05/05/2023 | 00596 | raise ceiling,
cover for drink holder
helped clean,
put part of 10:1 freezer together Jim did the rest
Caulked holes |
| 438 | Waylon | 05/04/2023 | 00596 | Finish light replace
Fixed UHC car right in van
Find door hinge Hanover?
Two arrow UHC strips
Cut to fit multiple ceilings tiles
Camera lens
Egg crates
Hang hook
Muffins toaster
Cup holder
HLZ Lo HLZ Hi
Fire extinguisher hole
Ice machine snake?
Caulked bathroom emergency light
TV in lobby
sink caulking
Lobby plastic bench covers |
| 437 | Brendan | 05/04/2023 | 00596 | -completed server 2016c many issues
-gave store the once over |
| 436 | Brendan | 05/04/2023 | 10622 | -replaced muffin toaster switch, pulled cord in so it's not exposed |
| 435 | Brendan | 05/04/2023 | 00596 | -printer refresh
-started BOS 2016 install |
| 434 | Jim | 05/04/2023 | 00596 | - Replaced O-ring on CO 2 line for Frappe machine
- Cleared drain line for ABS system, used CO2 plunger
-Cleared hand sink drain,used CO2 plunger
- Changed toaster belts
- Re worked prep sink drain to eliminate splash over
- Replaced ceiling tiles above sink area
- Installed locking cap on hanging outlet (yellow) |
| 433 | Jim | 05/01/2023 | 21582 | - Tried to clear ice machine drain, used snake to no avai.
Manager to call vendor |
| 432 | Jim | 05/03/2023 | 18198 | - grout various baseboard tiles
- remove and replace corner base tiles near washer
-remove old corner trim and replace with why painted trim |
| 431 | Brendan | 05/03/2023 | 04956 | -replaced oven controller, all set
-replaced grill OEP
-replaced all top elements, power switch, power cord, OEP. Also installed new slice slide @ muffin toaster
-installed door magnet @ shake machine |
| 430 | Waylon | 05/03/2023 | 18198 | -Replaced 4:1 fridge cord |
| 429 | Waylon | 05/03/2023 | 00596 | -Snaked and cleaned out drain / pump under drink station
-Looked at abs drain clog (suggested Jim with compressed air )
-Worked on ballast (not the ballast that was wrong it's the wiring did not finish come back tomorrow) (shocked myself)
-UHC cabinet strip stopped working (bad strip don't have any)
-Found bad hinge on a small refrigerator |
| 428 | Brendan | 05/03/2023 | 18198 | -pos15 dead. Swapped out with fc register for now. New register on order |
| 427 | Jim | 05/02/2023 | 18198 | -Removed broken baseboard tiles and replaced with new ones
- found vestibule tiles and cleaned and remounted to wall |
| 426 | Jim | 05/01/2023 | 18198 | - Replaced caster on assembly table
- checked three local stores for correct size caster no luck
-Removed tiles for replacement |
| 425 | Jim | 04/30/2023 | 21582 | Tried to clear clogged drain under ice machine
Had to call plumbing vendor |
| 424 | Brendan | 05/02/2023 | 07194 | -replaced frappe drain pan
-found source of leak by RO system. Cracked fitting. Took fitting out of system for now
-troubleshooted oven blowing breaker. Wired wrong on install |
| 423 | Waylon | 05/02/2023 | 00596 | -Installed a new light fixture |
| 422 | Waylon | 05/02/2023 | 18198 | -Replaced cord on 10:1 freezer
-Hung up paper towel dispenser |
| 421 | Waylon | 05/01/2023 | 18198 | Cut to fit 10 light lenses and had to adjust some of the holders for the light lense
-Tried putting on and cover (Brendan will take care)
-showed GM how to take out cup holders so they can wash |
| 420 | Brendan | 05/01/2023 | 12272 | -called for tea brewer not working. Bad pressure switch, bypassed for now |
| 419 | Brendan | 05/01/2023 | 17371 | -replaced fry station switch |
| 418 | Brendan | 05/01/2023 | 10622 | -looked at toaster not turning on. Bad power switch. On order
-extended FCB cord again
-looked at fryer motor not working. Chopped wires, store to call casco |
| 417 | Jim | 04/28/2023 | 10544 | - troubleshoot men's urinal , adjusted water flow and works fine
-hang toilet paper holder in men's room toilet
-cut and installed baseboard tile on corner at crew room entrance
- installed 12 baseboard tiles under sink
|
| 416 | Brendan | 04/27/2023 | 04956 | -FCB install |
| 415 | Brendan | 04/26/2023 | 00596 | -replaced bathroom door locks, store is now setup with buzzer system
-attempted to reimage RHS with pilot server 2016 images. massive fail. Will be back tomorrow with corrected images and backup RHS just in case |
| 414 | Jim | 04/27/2023 | 00596 | - re-set sink floor tiles using cement based mastic, will grout tomorrow
-Replaced lock collar on breakfast toaster
-removed corral support straps from wall, issue corrected |
| 413 | Jim | 04/26/2023 | 12272 | - R &R left side drain assembly, no leaks
- hang fire extinguisher by ABS at Drive thru
- check bakery case for blown bulbs , none found all working |
| 412 | Jim | 04/26/2023 | 00596 | - built and installed shelf under office desk for computers |
| 411 | Brendan | 04/25/2023 | 07417 | -called for KVS3 dead; found dead power supply. Replaced it with newer controller that used to be KVS6. Neatened up cords so they would not be near the heat. ORB and KVS6 on order |
| 410 | Brendan | 04/25/2023 | 12272 | -adjusted dt volume settings
-installed lobby exit device end caps |
| 409 | Waylon | 04/25/2023 | 00596 | -Fixed lobby tv not turning on
-diagnosed left side landing zone bad heater plate (Brendan helped)
-Installed shelf in grill for Tara
-installed 1 camera
-Concrete half of the corral dig holes and created border for inside corral post to give it more strength had to re steal it due to trash truck coming |
| 408 | Brendan | 04/25/2023 | 00596 | -replaced filet steamer water line
-replaced detex battery
-corrected lobby music issue
-ordered new M, L, XL cup tubes
-installed eProduction printer |
| 407 | Jim | 04/25/2023 | 00596 | -Steam cleaned and re set 6 floor tiles at rear sink
Cleaned wood ceiling tiles in lobby
-Support and re- dig post holes and mix concrete to re- support leaning corral wall |
| 406 | Jim | 04/24/2023 | 00596 | -Repaired Drive Thru present window latch
-Installed slop sink mop hanger
- worked with Waylon to re-align corral wall |
| 405 | Jim | 04/24/2023 | 02038 | Completed E Production system, ready for electronics
|
| 404 | Brendan | 04/24/2023 | 17371 | -blue screens after power outage. Reimaged pos1 and pos13. Swapped back to correct locations
-phone support swapping registers |
| 403 | Brendan | 04/23/2023 | 07417 | -troubleshooted kvs1 not booting. Totally dead. Replaced with ORB controller, had to hack my way to get it working |
| 402 | Waylon | 04/25/2023 | 18198 | -Sanitizer sink not holdin water replaced oring
-Corral picked up more wood finished left door just have the right door to do and 4 special cut pieces for gaps |
| 401 | Waylon | 04/24/2023 | 00596 | -Worked on UHC replaced multiple strips
-Diagnosed far left UHC needs palm pilot recalibration
-Diagnosed far right UHC bad display board tested rib ion cable and went through all menu settings
-Got supplies for the corral tmrw needs new concrete poured
-Dug 3 holes where concrete is needed
-Jim an i ratchet the fence up with straps |
| 400 | Brendan | 04/21/2023 | 21582 | -called for leak in lobby. Was able to slow it. Have parts on order |
| 399 | Brendan | 04/21/2023 | 17371 | -scrapped fry hopper for parts
-replaced fry station switch
-RHS 2016 upgrade |
| 398 | Brendan | 04/21/2023 | 18198 | -worked on removing reader board between dt windows |
| 397 | Jim | 04/21/2023 | 02038 | -R&R round egg fryer cord (Frayed)
-Tighten mans room faucet (loose)
-Ran wires to each location for E Production, ordered twist lock outlets needed |
| 396 | Jim | 04/20/2023 | 18198 | Continue to rebuild corral
|
| 395 | Waylon | 04/21/2023 | 02830 | -Replaced 11 UHC strips
-Tried helping with their AC problem but Rick is gonna need to be called (Brendan knows)
-Asked Brendan for one more UHC strip |
| 394 | Brendan | 04/20/2023 | 04956 | -installed spray head on coffee brewer
-replaced office door knob
-bypassed third UHC switch
-wired up CIP panel |
| 393 | Waylon | 04/19/2023 | 18198 | Corral project - Began putting up multiple boards got a good system going and started with more board cuts in the morning |
| 392 | Waylon | 04/18/2023 | 18198 | Corral project - collected half of the boards and began cuts and measurement |
| 391 | Jim | 04/19/2023 | 18198 | Continuing to rebuild the Coral |
| 390 | Brendan | 04/20/2023 | 18198 | -replaced lobby door exit device
-replaced HV board, display board, and top touch panel on Qing oven |
| 389 | Brendan | 04/19/2023 | 18198 | -troubleshooted Qing oven. Bad HV board
|
| 388 | Jim | 04/18/2023 | 18198 | Removed and installed new boards on corral surround |
| 387 | Jim | 04/17/2023 | 18198 | Calculated lumber and supplies for corral surround replacement |
| 386 | Jim | 04/17/2023 | 12272 | Replaced sink trap still leaking, ordered sink strainer and top drain unit.
Side one and side two bump bars relocated to allow more room for toasters.
Repaired ladies room handicap toilet had to replace down pipe with proper vacuum pipe |
| 385 | Brendan | 04/18/2023 | 07417 | -crimped new connector on PED 15 network cable |
| 384 | Brendan | 04/18/2023 | 02038 | -OJ machine install |
| 383 | Brendan | 04/18/2023 | 18198 | -scrapped old fry hopper for parts
-reversed door on new dry hopper |
| 382 | Brendan | 04/17/2023 | 07417 | -performed major surgery on the tea brewer. replaced hood.
- replaced blower motor on side, ordered replenishment
-installed screws in egg cooker |
| 381 | Brendan | 04/17/2023 | 25383 | -replaced hi-c bib pump
- replaced dt monitor in cbb cell
-fixed mens room sink cold water. was just shut off
-ordered new office printer
-cleaned up list |
| 380 | Brendan | 04/17/2023 | 04205 | -repaired oven door close mechanism
-installed oven temp control knob |
| 379 | Brendan | 04/17/2023 | 07194 | -repaired bun toaster with multiple issues; replaced sprockets, motor, thermocouple
-ABS leaking from underneath. Clogged cold plate. Unclogged.
-ordered g40 bulbs
-ordered ABS arm grips |
| 378 | Waylon | 04/17/2023 | 18198 | -UHC cabinet needs new cord between cabinet strip and side board (Brendan ordered)
-Put metal cover above trash can next to lobby drink station
-Screwed and caulked ssbs metal baseboard
-Took a trip to Home Depot picked up supplies but weather needs to be better
-Replaced light lense outback cut to fit
-Replace a ceiling tile with a vent in it cut to fit back cash
-talked with Jim about corral plan and Brendan approved going to work on tmrw |
| 377 | Jim | 04/15/2023 | 00596 | Steam cleaned and grouted drive thru present area
Grouted vestibule tiles |
| 376 | Jim | 04/14/2023 | 00596 | Steam cleaned and grouted rear sink area
Sourced and replaced two broken vestibule tiles |
| 375 | Jim | 04/13/2023 | 04205 | Received part and repaired men's room toilet
|
| 374 | Jim | 04/11/2023 | 00596 | Steam cleaned and grouted the rear sink area |
| 373 | Jim | 04/11/2023 | 02830 | Purchased and installed new lobby TV |
| 372 | Brendan | 04/14/2023 | 07194 | -diagnosed bun toaster, needs sprockets and motor. On order
-repaired lobby Dr Pepper; replaced armature tip and solenoid
-replaced 4 cup fingers on 32oz cup tube
-troubleshooted fry hopper ERR 4. Needed calibration |
| 371 | Brendan | 04/13/2023 | 04205 | -replaced two armatures for blended ice rinser
-eProduction imaging
-corrected BBN settings. Rotated bump bar |
| 370 | Brendan | 04/13/2023 | 18198 | -replaced dogging mech on lobby door
-other lobby door was rusted on tight. Had to forcibly remove push bar. It will at least lock now. New one on order |
| 369 | Waylon | 04/13/2023 | 02830 | -Helped change thermostat setting showed how to up and lower it
- aided Brendan in order a new cabinet
-Detex was not randomly beeping |
| 368 | Waylon | 04/13/2023 | 18198 | -Qing oven not heating- went through the whole thing tested transformers, fuses, triacs, capacitors, magnetron, thermal cutouts, and was supposed to check HV board but did not know fully how to
-Brendan is gonna diagnose later to make sure everything checks out |
| 367 | Brendan | 04/12/2023 | 12272 | -repaired womens right hand sink
-attempted to repair toilet as well with a new vacuum breaker. That solved one problem but then another one popped up. Parts on order |
| 366 | Brendan | 04/12/2023 | 07417 | -camera footage'
-bypassed filter switch @ OJ |
| 365 | Waylon | 04/12/2023 | 04205 | -Finished installed bakery monitor
-Replaced tile above old qpc mount
-Installed wall mount for baked
-Ran printer cord across store
-Cut through multiple spots in ceiling to find Ethernet cable (very hard to work in their ceiling)
** need to replace one ceiling tile that was cut through on accident outside office door does not have any on me at the time
-Helped reformat and print documents for manager and fix printer jam
-Installed bump bar into the wall below baked monitor |
| 364 | Waylon | 04/12/2023 | 18198 | -Picked up new washing machine
-Trashed old washing machine (in corral Ashley wants it)
-Installed new washing machine including drilling ecolab hole and all the tubes
-Turned on and off dvr because back drive thru cameras weren't showing seemed to solve the problem
-Kiosk black screen reset computer and logged pos in
-front counter cashless device restarted wasn't connecting to pos
-made space in van for washer
-Picked up u bulbs and weather strip for lee |
| 363 | Waylon | 04/11/2023 | 04205 | -Worked on eproduction install of quarter monitor moving and taking old mount down
-fixed barstool in lobby foot rest was totally broken off put new screws in |
| 362 | Brendan | 04/11/2023 | 18198 | -troubleshooted washer. bad computer. Waylon will pick up and install new washer tomorrow
-replaced regulator assembly @ bun steamer |
| 361 | Brendan | 04/11/2023 | 10622 | -installed extension for FCB
-mounted fire extinguisher
-mounted ecolab
-replaced Hi-c BIB pump |
| 360 | Waylon | 04/11/2023 | 18198 | -was told washing machine is leaking everywhere change the load setting to deep wash instead of auto sensing and it ran one load perfectly fine. I do not have time to stay and run another one so they will let me know when I get back
-Caulked back sink in more places still leaking think I found the source is just drying now
|
| 359 | Brendan | 04/10/2023 | 07417 | -troubleshooted tea brewer. Hood metal disintegrated. Jerry rigged for now, parts on order
-calibrated FFLS screen
-adjusted menu board hours |
| 358 | Brendan | 04/10/2023 | 21582 | -relocated co2 alarm |
| 357 | Brendan | 04/10/2023 | 12272 | -troubleshoot ladies toilet and faucet. Toilet needs new flange. Faucet needs new drain and stem. On order
-crimped connector on epr1 bump bar |
| 356 | Brendan | 04/10/2023 | 02038 | -replaced lunch 1 initiator monitor. Very stubborn |
| 355 | Jim | 04/10/2023 | 00596 | Steam cleaned and grouted back sink area ( half done)
Removed and replaced delivery door sweep and weather strip
|
| 354 | Waylon | 04/07/2023 | 00596 | -Had them order multiple hand sanitizer and soap pumps
-fixed their one working soap pump
-Installed towel dispenser picked up from Hanover
-Fixed ceiling grid leaning
-Fixed sink in men's bathroom clogged all the way up snakes about 20 feet down |
| 353 | Waylon | 04/10/2023 | 00596 | -Grouted more than half of the back sink area starting from the wall made it up to the back sink before stopping with Jim
-put back up no loitering poles
-looked at hole in front dt said to be leaking cleaned it all out with the shop vac did not see a leak so will check back next time I'm here looked perfectly fine
-hand wash sink switch around knobs so their main sink could have hot and cold water instead of just cold
|
| 352 | Brendan | 04/07/2023 | 04956 | -replaced parts on dish sink sprayer
-replaced hand wash sink faucet
-ran line relocated RO storage tank |
| 351 | Brendan | 04/07/2023 | 07417 | -removed two fry sockets |
| 350 | Brendan | 04/07/2023 | 17371 | -eProduction imaging
-replaced drain flange on back hand sink
-troubleshooted chill rail. Bad controller and blower. On order |
| 349 | Jim | 04/07/2023 | 04205 | Worked on men's room toilet
The flush system is not square to the toilet connection
Had to source supply side extension
Also had to order last part needed none available locally |
| 348 | Jim | 04/06/2023 | 00596 | Installed outlet for RTI system
Removed graffiti in men's bathroom stall |
| 347 | Jim | 04/06/2023 | 21582 | Repaired first Drive Thru window latch, installed two springs
Purchased and mounted mop holder over slop sink
Caulked around inside corners of walk in entrance
Purchased gal of grey exterior paint and painted outside areas as needed |
| 346 | Waylon | 04/07/2023 | 18198 | Back door push bar back needed new screws on both sides |
| 345 | Brendan | 04/06/2023 | 07417 | -went to look at OJ machine again. Removing and reinserting the air filter fixed the issue |
| 344 | Brendan | 04/06/2023 | 04956 | -called for all fryers and grills down. Traced issue back to the grill vent hoods shorted to ground and tripped the main breaker. Went on the roof so find a mess of exposed wiring, which was chafing against the metal of the vent. Store to follow up with Rick in the morning |
| 343 | Waylon | 04/06/2023 | 00596 | -Tighten outside door hinge handle
-Tighten men's room toilet sensor
-mounted fire extinguisher
-cover plate behind Sam wall and grouted the side to blend in
-Installed new tp dispenser in woman's bathroom
-Fixed emergency light hanging down
-Fixed vestibule tiles broken / pushed out
-Looked at paper towel dispenser I think Hanover has one
|
| 342 | Brendan | 04/05/2023 | 25383 | -eProduction imaging
-installed new battery in grill emergency light |
| 341 | Brendan | 04/05/2023 | 21582 | -repaired receipt printer, replaced two
-removed emergency light put on a blank plate
-troubleshooted coffee brewer. Talked to Bunn tech, who says they come with pulse brew now |
| 340 | Jim | 04/05/2023 | 21582 | Prepped and installed 1 1/4' clear trim, back painted white , installed on office wall
Chipped out 9 Nine base board tiles and grouted at end of day
In Vestibule on DT side taped off surrounding area and painted stains I. Ceiling tiles |
| 339 | Waylon | 04/05/2023 | 21582 | -Vestibule ceiling tiles replaced 4 and cut to fit all of them
-Coffee maker replaced computer board WASNT the problem out the solenoid in waiting on two clamps from Brendan
-brought headset from epping
-installed whole new camera
-Fixed light ballast and replaced bulb
-Plugged more holes and cleaned the left over holes off from yesterday
|
| 338 | Waylon | 04/04/2023 | 21582 | -Cut to fit multiple ceiling tiles from the grill and back
-Set up the ceiling tile above the egg cooker instead of a lobby tile
-Caulked holes from the front of the store all the way back
-Put a outlet cover next to drive thru window
-Washing machine cover
-Back sink drain handle
|
| 337 | Waylon | 04/05/2023 | 18198 | -Patched many random holes with caulking from the grill to the offices
-Removed random screw in the wall |
| 336 | Brendan | 04/04/2023 | 07417 | -finished eProduction staging |
| 335 | Brendan | 04/04/2023 | 04956 | -went to replace dish hose. I ordered the wrong size. Whole faucet is in not the best condition so I'll just order a brand new one |
| 334 | Brendan | 04/04/2023 | 12272 | -eProduction imaging. Ran into issue with outdated config.ini |
| 333 | Brendan | 04/04/2023 | 02038 | -repaired HIc line that exploded
-repaired Leaky automist line
-installed ROA shelf |
| 332 | Brendan | 04/04/2023 | 21582 | -replaced emergency light men's room
-replaced ice gate SSBS
-LED retrofit SSBS
|
| 331 | Waylon | 04/04/2023 | 00596 | -Went to stop sink from leaking discovered that the seal was broken causing the leak (originally I thought it was good) also found that the sink is backed up. I used a small snake and a big snake and couldn't seem to clear the back age
*Notified Brendan |
| 330 | Jim | 04/04/2023 | 21582 | Prepped and installed 8 eight clear corner trim painted white on inside. Around crew room entry, &opening at first Drivethru station
Lifted Q-uing oven table and changed one wheel
Prepped and installed 3 three clear corner trim painted white on the inside, around walk-in door |
| 329 | Jim | 04/04/2023 | 00596 | Red rolled and tapped for new machine screws , re-mounted crash bar on delivery door |
| 328 | Jim | 04/04/2023 | 07417 | Installed outlet above the Qing ovens for E Production
|
| 327 | Waylon | 04/04/2023 | 18198 | -Replaced Qing oven switch
-fixed ice cover out back needed new screws
-Foxed drain cover near Allan's tool box popping out and tripping hazard and then grouted all around it |
| 326 | Waylon | 04/03/2023 | 12272 | -Finished all eproduction
-Fixed metal sticking out of oven |
| 325 | Brendan | 04/03/2023 | 07417 | -repaired OJ machine not turning on
-eProduction imaging |
| 324 | Brendan | 04/03/2023 | 10544 | -traced electrical issue with prep fridge/eProduction
-eProduction imaging |
| 323 | Brendan | 04/03/2023 | 21582 | -repaired issue with BIM leaking |
| 322 | Jim | 04/03/2023 | 25383 | Clean two wall tiles and reattach and grout in DT side vestibule
Reattach wall tile that caved in in women's bathroom stall and grout
Installed speed patch in pot hole at delivery/ trash door |
| 321 | Brendan | 04/01/2023 | 18198 | -eproduction product setup |
| 320 | Brendan | 04/01/2023 | 07417 | -helped out a bit
-repaired oven. The part came in very early. One thing is on bypass, still waiting for that part to come in.
-troubleshooted OJ, will need to scrounge around the company for parts on monday |
| 319 | Brendan | 03/31/2023 | 21582 | -attempted to repair BIM water line. Needs new valve block. On order.
-was going to replace fry hopper motor, no trouble found
-investigated outlet for hot water recirc. No trouble found
-diagnosed coffee brewer. Needs a new board, on order
-gave store once over, adding to list:
Need new emergency lights by back sink
SSBS needs new starters and ice gate plate |
| 318 | Brendan | 03/31/2023 | 02038 | -went for cash drawer not opening. It was locked' |
| 317 | Brendan | 03/31/2023 | 07417 | -eProduction imaging |
| 316 | Brendan | 03/31/2023 | 18198 | -eProduction imaging |
| 315 | Jim | 03/31/2023 | 25383 | Re fasten numerous pieces of coral and replaced (4) four damaged boards, also straightened coral walls around entrance
Replaced fridge light behind lobby register
Reattached lobby wallpaper |
| 314 | Waylon | 03/31/2023 | 12272 | -Moved QPC monitor for eproduction (ceiling gave a ton of trouble with all the oil lines) |
| 313 | Brendan | 03/28/2023 | 02038 | -repaired door dogging latch, dt side
-replaced muffin toaster OEP with 4 prong plug
-repaired waterline to BIM |
| 312 | Brendan | 03/30/2023 | 10622 | -dropped off ABS arm grips |
| 311 | Brendan | 03/30/2023 | 17371 | -called for fry station out AGAIN. breaker not giving voltage. Moved to different beaker on a different bus. Also replaced one fry socket |
| 310 | Brendan | 03/30/2023 | 00596 | -egg cooker cord cut, cut back cord and reconnected |
| 309 | Waylon | 03/30/2023 | 21582 | -Put up light lens near fc that was missing
-Replaced all their egg crate ceiling with brand new ones and had to cut to fit all of them
-Diagnosed coffee brewer believe it's a bad solenoid the bottom one which Is the refill solenoid
-Diagnosed landing zone giving error for 'prob' and no heat coming from the vent or the heating pad
-Grouted a ton of spots
''Crew room giant crack across it
'Jim's new tile near the bun rack
''another new tile near the back door
'' 3 tiles in the walk-in
''Outside crew room door on the corner left side
-Put new screws into the freezer ramp put 5 in to hold the metal and wood together and stopped it from wobbling
-Fixed a little bit of wallpaper in crew room with mastic
-Went to Queen City glass picked up men's bathroom mirror and brought it back all hung up (tugged on it a little to make sure it was secure) |
| 308 | Jim | 03/30/2023 | 21582 | Tape off and Spray lobby ceiling to conceal stains
Paint and install corner trim at Crew room entrance
Remove and install baseboard tiles three by the misting system,
Three in walk-in, and two by the rear door |
| 307 | Jim | 03/29/2023 | 21582 | Grout three areas of new bases tile
Sourced tools for ceiling adjustment, also picked up lobby ceiling tiles
Raise drooping ceiling and secure level
|
| 306 | Waylon | 03/29/2023 | 21582 | -Raised ceiling that was falling (Jim used his air bag and I went in with wire and raised the whole grid fixed it perfectly up) reinforced the grid
-Dremeled sheets of metal to cover all the remaining holes for soda cups that were broken (7 holes)
- tapped and drilled the metal sheets
-Helped Jimwith some of the lobby ceiling tiles
-changed coffee brewer temperature and I tried switching its brewing mode would not switch properly so gonna give it another shot tomorrow morning |
| 305 | Jim | 03/28/2023 | 21582 | Grout floor area in front of sink and slop sink
Removed broken base tiles in three areas installed new tile and cut as required |
| 304 | Jim | 03/27/2023 | 21582 | Grout front baseboard and floor tiles behind the shake machine and frappe machine
Replaced two tiles on baseboard
Grouted baseboard tiles next to walk-in
Replaced left side weather strip on rear door |
| 303 | Waylon | 03/28/2023 | 21582 | -Put on soda cup metal cover
-Installed 2 new TP jump dispensers in woman's bathroom had to drill the tile to install
-BIM back side wall was half fallen off put glue to cover it up then grouted it to blend in with the tiles
-Grouted seats in lobby that were discolored to tiles
-Put wall paste to hold the wall paper back up to the wall
-Coffee brewer replaced spigot for hot water |
| 302 | Waylon | 03/27/2023 | 21582 | -Had to replace one UHC strip in each of the three cabinets
-Helped Shannon put together and start pressure washer
-Replaced ballast in crew room
-Brought men's room mirror to granite state glass |
| 301 | Brendan | 03/27/2023 | 07417 | -troubleshooted fish vat, loose connection
-cleared error codes on Qing ovens
-replaced oring on lemonade
-replaced spring on customer side door |
| 300 | Brendan | 03/27/2023 | 00596 | -replaced GFCI for fridge and delivery printer
-replaced abs ice gate
-replaced oring @ BIM CO2 |
| 299 | Brendan | 03/27/2023 | 04205 | -diagnosed BIM, bad armatures for water solenoids. On order.
-looked into Fanta not working. No trouble found |
| 298 | Brendan | 03/27/2023 | 02830 | -called for ABS no power. Tripped breaker' |
| 297 | Brendan | 03/27/2023 | 04956 | -replaced ped15 |
| 296 | Jim | 03/24/2023 | 02038 | Installed one chassis could not locate the final one
Checked Raymond and Epping as I was close by.
|
| 295 | Jim | 03/24/2023 | 12272 | Completed E Production electrical system hookup, all tested and operational
Replaced six lobby ceiling tiles |
| 294 | Waylon | 03/24/2023 | 04205 | -Replaced Soda bib out back (Diet Coke)
-fixed leak from frappe machine (drain pan was clogged) |
| 293 | Jim | 03/23/2023 | 12272 | Sink drain leaking, replaced trap and elbow to stop leak
On the way back to Hooksett had interval oil change done.
|
| 292 | Jim | 03/23/2023 | 10544 | Went to repair faucet, found flex hose connection came loose, applied Teflon tape and reinstalled. No leaks
|
| 291 | Waylon | 03/23/2023 | 12272 | -had to find wall mounts for eproduction
-got walk mounts put all 3 walls mounts up
- had him help drew through tile and then drilled the rest in
- later on the manager asked me to move a mount so i did
- put the fried screeen and computer up
-put fry station screen up |
| 290 | Waylon | 03/23/2023 | 18198 | Drill and taped a drain the screws were stripped and was becoming a tripping hazard for crew |
| 289 | Jim | 03/21/2023 | 04205 | Unpacked and brought inside store three unit fryolator
|
| 288 | Jim | 03/21/2023 | 12272 | Worked on the E Production system completed two of four electrical connections |
| 287 | Jim | 03/21/2023 | 02830 | Replaced left side 50 Amp outlet and plug on right hand grille
Unit works fine now |
| 286 | Waylon | 03/22/2023 | 04205 | -Set up first half of eproduction
- Ran 1/2 Ethernet cables for the fried computer
-Installed 2 mounts
-Set up fried product computer and monitor
-Installed fries station monitor
-Ran daisy link cable
|
| 285 | Brendan | 03/21/2023 | 18198 | -caught up with mark from J&J, ordered parts he caught as defective |
| 284 | Brendan | 03/21/2023 | 21582 | -went for shake machine issues. Refrigeration issue, store to call Taylor
-repaired Qing oven, replaced display board |
| 283 | Brendan | 03/21/2023 | 17371 | -rewired fry station |
| 282 | Waylon | 03/21/2023 | 17371 | -Set up baked eproduction
-Couldn't figure out how to get quarter monitor to stay
-Grouted men's bathroom (corner next to door hard left) (Top right of the big stall outside of it)
-Grouted women's bathroom (small stall back side of the door whole wall)
-brought work too fridge from Raymond to Alton
-Picked up 1/2 fence from granite state fencing
-fixed front counter silver strip |
| 281 | Brendan | 03/20/2023 | 04956 | -replaced ABS drain fitting attached hose
-replaced biscuit oven temp probe
-replaced MIS bib tubing, connectors, and collars |
| 280 | Brendan | 03/20/2023 | 25383 | -troubleshooted kvs monitor breaker tripping. I found swapped neutral and hot legs. A dead end segment of MC. Wires shorting against MC sheath due to no anti-short bushing. Hot wire on hotg chase shorting against other wire (I think due to MC cutter blade). Corrected all issues. |
| 279 | Waylon | 03/20/2023 | 25383 | -Took down HOTG monitor and computer
-Moved HOTG to a new mount
-Took down old HOTG mount from the ceiling
-Replaced ceiling tiles outback and HOTG tile
-Ran to get Brendan Batteries
-Installed bakery mount into the ceiling
-Set up computer and monitor on to bakery mount
-Ran printer cord
-Cut two ceiling tiles |
| 278 | Jim | 03/20/2023 | 25383 | Connected E Production system, 3 chassis's and one ceiling outlet all wired up
Replaced burnt outlet below register at #1 drive thru
Installed new weather stripping around rear door |
| 277 | Jim | 03/16/2023 | 17371 | Called to replace fry station breaker.
Replaced breaker in panel AP-1 #2, kept tripping troubleshoot issues and retry
Ultimately replaced all fry sockets (4) and some high temp wire and connectors
Removed and retightened outside door handle
Checked dining room window shade for size of chain to adjust shade |
| 276 | Brendan | 03/19/2023 | 00596 | -called for egg cooker not working, found breaker tripped. Reset and let run, seems stable
-ABS ice gate faliure. New ice gate on order
-fixed issue with FFLS
-installed McFlurry mixer lid
-ordered hanger for juice lid dispenser |
| 275 | Brendan | 03/19/2023 | 02830 | -printer refresh |
| 274 | Waylon | 03/17/2023 | 02038 | Epsom '-> Derry 2 drawer meat freezer |
| 273 | Brendan | 03/16/2023 | 04956 | -looked at ABS leaking, new drain fitting on order
-looked at oven error, new probe on order
-mounted bump bars |
| 272 | Brendan | 03/16/2023 | 21582 | -diagnosed Qing oven. Very frustrating. Ordered parts we will see
-finished up eProduction
-verified juice calibration |
| 271 | Waylon | 03/16/2023 | 25383 | -Installed 3 mounts
-Installed fried product monitor and computer
-Mounted fried bump bar
-Ran two Ethernet cables
-Installed fry station monitor
-Rain daisy link |
| 270 | Brendan | 03/16/2023 | 18198 | -replaced carb motor for lobby. All soda up |
| 269 | Waylon | 03/16/2023 | 07417 | -Finished installing mount into ceiling
-Installed monitor and all the cords
-Set up printer and ran cord
-Ran baked Ethernet cable
-installed new switch into qing oven (When turned on had a rattling noise after looking the fan was hitting so I used 4 washers and electrical tape to prop it up and steady it out so no noise is being made)
Qing oven working properly when I left |
| 268 | Jim | 03/15/2023 | 25383 | Set up E Production chassis's (3) and have it partially wired |
| 267 | Brendan | 03/15/2023 | 25383 | -fixed leak @ multiplex; replaced circ A motor and insulated
-repaired Qing oven prep side; replaced transformers, capacitors, fuses
-calibrated juice machine to proper spec
-repaired rootbeer in lobby; replaced armature tip
-troubleshooted grill emergency lighting, bad batteries. Will pick up from batteries+ |
| 266 | Brendan | 03/13/2023 | 10622 | -diagnosed ABS conveyor issue. needs new motor, on order |
| 265 | Brendan | 03/13/2023 | 02038 | -fixed multiplex leaking
-reimaged delivery monitor
-replaced momentary switch on McFlurry spinner
-fixed receipt printer not working |
| 264 | Brendan | 03/13/2023 | 18198 | -troubleshooted carb tanks. needs new float switch/probe. on order |
| 263 | Brendan | 03/15/2023 | 10622 | -replaced conveyor motor @ABS |
| 262 | Waylon | 03/14/2023 | 18198 | -Installed new attic stair board goes over the old board to help support it (screwed in two spots on each side tested 200 pound weight)
-Replaced carbonators broken parts with Brendan's guidance (Abs and drink station both fully functional) |
| 261 | Waylon | 03/15/2023 | 07417 | -Finished taking mount down from the ceiling and moved to new bakery monitor location
-Half way installed just needs the second half put in and the ceiling cut |
| 260 | Waylon | 03/15/2023 | 07417 | - Switch the quarter monitor on to the new mount
-Took only half of the old mount from the ceiling
-Set up quarter monitor then ran into the bump bar not working
-Switched out with new computer now up and running |
| 259 | Brendan | 03/15/2023 | 17371 | -called for fry station kept tripping breaker., replaced switch seems stable |
| 258 | Jim | 03/14/2023 | 04205 | Completed all electrical connections for E-Production system |
| 257 | Jim | 03/14/2023 | 07417 | Completed all electrical connections for E-Production system |
| 256 | Waylon | 03/14/2023 | 18198 | -Screwed in metal siding board above tiles in back cash (Liquis nails weren't holding well at all after sitting for 24 hour)
-Replaced 8 lobby tiles
-Cut and fit 4 of the lobby tiles |
| 255 | Waylon | 03/13/2023 | 00596 | -Grouting prep sink |
| 254 | Waylon | 03/13/2023 | 18198 | -diagnosed UHC display board needs to replaced
-Replaced UHC strip on side 2 and adjusted another strip on side 2 that was popping out
-Rehung abs ice cover
-Grouted second window and first windows corner
-Liquid nails the metal siding above grout for first window (Left tool holder on it to dry more)
-Filet steamer spilling water everywhere adjusted the water filter cap where excess water was coming from
-Coffee brewers stopped having water go to them just unplugged seemed to solve the problem when water began to suck through the line |
| 253 | Brendan | 03/11/2023 | 12272 | -replaced OJ valve, calibrated.
-replaced water strainer multiplex |
| 252 | Brendan | 03/11/2023 | 02038 | -installed new toasters
-replaced delivery monitor |
| 251 | Brendan | 03/09/2023 | 18198 | -troubleshooted vat 1 not working. Replaced AIF board should be all set |
| 250 | Brendan | 03/09/2023 | 07417 | -adjusted juice machine setting so it wouldn't freeze up |
| 249 | Brendan | 03/09/2023 | 04205 | -troubleshooted oven not temping. Door switch acting up. Adjusted mechanism working better. Checked heating coils and contactor which are fine. Ordered new temp control and knob that is needed to calibrate temp |
| 248 | Brendan | 03/09/2023 | 17371 | -replaced ABS transformer in ice control box, put back old beverage interface board that was working |
| 247 | Waylon | 03/09/2023 | 07417 | -Installed 3 chassis mounts (Fried, Fries, and HOTG)
-Installed the fried monitor and computer
-Mounted fried bump bar
-Fried monitor has speaker
-Ran daisy link for fried ~~> fries monitor
-Installed fries monitor
-Printer is in designated spot
-Ran 1 of 2 Ethernet cables for fried computer haven't done baked
|
| 246 | Jim | 03/09/2023 | 04205 | Had to replace the delivery door trim due to the delivery driver using the electric pallet jack inside the building and ripped the weather strip off the door at the bottom |
| 245 | Jim | 03/09/2023 | 02830 | Sourced two replacement plugs and one outlet for the 50 Amp lines to Griddle
Replaced one outlet and one plug
Reconnected griddle and powered up works fine but still need to replace the other outlet and plug when we get the outlet |
| 244 | Jim | 03/09/2023 | 07417 | Ran two wires for E Production system, got a call from Brendan to go to Hooktand replace griddle outlets |
| 243 | Waylon | 03/09/2023 | 10544 | -Moved HOTG monitor and computer to new mount
-Took old mount bar down left the horizontal bar in there though |
| 242 | Waylon | 03/08/2023 | 18198 | -Installed 4 new light lenses
-Put two egg crates up for the vents
-Installed black old vent into grill temporary until the ones Brendan ordered come in
-put the vent that was sitting in the ceiling above the dish sink in
-Reused old egg crate for that one since I ran out at the time (temporary)
-caulked piping under the sink (not sure exactly what's leaking so covered some pipes and just trail and error) |
| 241 | Waylon | 03/08/2023 | 18198 | -Adjusted all cameras and made them face right directions and not be flipped upside down |
| 240 | Waylon | 03/07/2023 | 10544 | -Installed all 3 eproduction monitors
-Rain daisy link for fried and fries
-Installed bake and fried computers
(Need to move hotg mount still)
|
| 239 | Brendan | 03/08/2023 | 17371 | -fixed most of the fry bulbs that were out. Still needs 1 socket
-attempted to repair ABS by replacing beverage interface board. Which apparently I misdiagnosed. The actual issue is a bad transformer in the ice control box. Burnt up, no voltage out. Correct part is on order and should be there tomorrow. |
| 238 | Brendan | 03/08/2023 | 07417 | -replaced fans and motor on pie warmer
-adjusted water bath temp for freezing water @ juice
-ordered parts for oven that occasionally has a high limit trip |
| 237 | Jim | 03/08/2023 | 07417 | Installed three E Production chassis's
Fixed fish fry issue ( would not heat up)
|
| 236 | Jim | 03/08/2023 | 04205 | Replaced weatherstripping on left side of rear delivery door and lowered previously installed door sweep. |
| 235 | Jim | 03/07/2023 | 04205 | Set up and installed three E Production chassis's |
| 234 | Jim | 03/07/2023 | 10544 | Tried to complete wiring E Production to power and encountered an Open Hot issue, spoke to Brendan and he will check out to connect |
| 233 | Waylon | 03/08/2023 | 07417 | -Diagnosed Qing oven (Door switch)
-Ceiling tiles in lobby had to fixed and adjusted
-Put new ceiling tiles into the stock room
-Frappe machine waste bin was overflowing with gunk emptied and cleaned out now it's all good
-UHC cabinet needed a new switch
-Fixed camera cords hanging out of the ceiling
-DT bar was hit today and pushed back so just put back in place
-Vent in stock room adjusted and set in place |
| 232 | Brendan | 03/08/2023 | 02830 | -looked at grill cord, seems to be a Taylor issue |
| 231 | Brendan | 03/08/2023 | 04956 | -repaired broken hose in multiplex
-applied lemonade decals |
| 230 | Brendan | 03/07/2023 | 04205 | -lemonade install |
| 229 | Brendan | 03/07/2023 | 07194 | -lemonade install
-repaired washing machine |
| 228 | Brendan | 03/07/2023 | 10544 | -replaced solenoid assembly @ OJ. installed and calibrated
-got IDMB 1 running, stratacache will need to come out to replace media player |
| 227 | Brendan | 03/07/2023 | 07417 | -lemonade install |
| 226 | Jim | 03/06/2023 | 04205 | Installed door seal on outside door next to first DT window |
| 225 | Jim | 03/06/2023 | 10544 | Worked on connecting all e production stations
Had trouble wiring to existing outlet for power
Had open hot after hookup, couldn't find issue Brendan will troubleshoot
Connected sink fitting on rear sink |
| 224 | Brendan | 03/07/2023 | 00596 | -programmed eProduction items |
| 223 | Brendan | 03/06/2023 | 12272 | -lemonade install. Found very low water flow from left side. Tried cleaning injector and pump assembly but still low follow. It works for now, albeit very slow pour times. New pump on order |
| 222 | Waylon | 03/06/2023 | 10544 | -Installed 4 metal mounts (Fry station, Fried products, Bakery, and quarter monitor new spot)
-caulked the back sink hole in the wall |
| 221 | Brendan | 03/06/2023 | 02038 | -upgraded c009 calibrated. Attempted install of lemonade but left side didn't work. Needs new concentrate pump. Part costs $1300 so will be ordering new machine instead |
| 220 | Waylon | 03/06/2023 | 00596 | -Checked error message for UHC near HLZ on side 1(push button 1)
I believe it's a display board problem for just that bottom row but not 100% sure I switched the ports out so it can't be the board |
| 219 | Waylon | 03/06/2023 | 02038 | -Replaced two new UHC strips (old cabinets) |
| 218 | Waylon | 03/02/2023 | 17371 | -eproduction all set up
-Fried products computer and monitor is all done including Ethernet cable
-Fries monitor is all set up including daisy link
-Bake monitor is mounted (missing computer) so all cords are under it
-Bump bars and speakers installed and Ethernet ran for bake |
| 217 | Waylon | 03/02/2023 | 02038 | -Fixed sprite in lobby only soda water just adjusted mixer valve |
| 216 | Brendan | 03/03/2023 | 04956 | -replaced filet steamer membrane and display board |
| 215 | Brendan | 03/03/2023 | 00596 | -replaced McFlurry mixer motor and plug
-temporarily replaced water line to filet steamer
-eProduction |
| 214 | Jim | 03/03/2023 | 10544 | Started E Production need to wire rear grill and baking station |
| 213 | Brendan | 03/03/2023 | 10622 | -upgraded c009 to install lemonade |
| 212 | Brendan | 03/03/2023 | 17371 | -went to look at ABS not working. Went on a wild goose chase. Found breaker hooked up incorrectly causing it to kill a board. On order |
| 211 | Jim | 03/02/2023 | 17371 | E Production system completed Breaker # 8 in the computer panel.
Replaced Breaker #14 on panel AP-4, reconnected wire temporarily removed .
Installed oil dam under the fry bin right side flange.
Installed and powered RTI outlet/ ready for use |
| 210 | Waylon | 03/02/2023 | 04205 | -Replaced cabinet strip and made sure is not pushed in (problem with board for the third row of the second cabinet buttons don't work at all on both sides) told Brendan part ordered
-Lobby lemonade needed new armature tip and is calibrated |
| 209 | Waylon | 03/02/2023 | 21582 | -Light lens for back door
-Egg crate for outside of freezer
-2 UHC cabinet strips old
-Bun toaster door kept falling off (put a pin in it and bent to hold probably more of a short term fix)
-Transported co2 back up to south willow |
| 208 | Brendan | 03/02/2023 | 04956 | -fixed security camera issues
-troubleshooted bibs not automatically changing over. Found bib rack pushed to close to wall preventing ACV from actuating
-troubleshooted filet steamer button not working. Part on order |
| 207 | Brendan | 03/01/2023 | 10544 | -replaced dish sprayer. Realized it didn't come with the tee for ecolab dispenser. Used faucet port for now, tee on order. Will return ASAP when arrives
-Ran water line for OJ and installed. Machine defective on arrival. Right side dispense solenoid is bypassing. New valve on order. |
| 206 | Brendan | 03/01/2023 | 12272 | RBD |
| 205 | Jim | 03/01/2023 | 17371 | Replaced UHC caster
Replaced leaking hand sink by office , replaced drain, ptrap.
Prepped and installed three E Production chassis's need wiring
|
| 204 | Brendan | 03/01/2023 | 18198 | -met with mellitta guy who said water pressure was too high. Adjusted regulator on blended RO to get it good enough. Need to order new regulator and gauge |
| 203 | Jim | 02/28/2023 | 17371 | Replaced duplex outlet left side red tiled wall, need to trace back to find issues
Troubleshoot fish steamer/All set
Found ceiling connection for RTI system power
|
| 202 | Jim | 02/28/2023 | 00596 | Wire in ceiling not connected/all connections completed for E Production system
Panel AP-2 Breaker # 11 |
| 201 | Waylon | 02/28/2023 | 18198 | -Got a printer from Jimmy hooked up
-quarter monitor didn't have power (breaker just was turn off) |
| 200 | Waylon | 02/28/2023 | 02830 | Set up speakers and printer for eoroduction |
| 199 | Waylon | 02/28/2023 | 18198 | -Installed new pipe for water leakage and clamped
-Finished eproduction install
|
| 198 | Jim | 02/27/2023 | 00596 | Dropped truck at Kerner's for the sticker
Work on electrical connections for the E Production system
Nd to check front chassis and associated connections |
| 197 | Jim | 02/27/2023 | 10622 | Purchased two tires from Sullivan Tire for work truck and had them mounted and balanced at Manchester street' tire warehouse ' they did not charge for the service.
|
| 196 | Waylon | 02/27/2023 | 00596 | -Quarter pounder monitor move
-Mount installed above grill and quarter monitor put on
-Took out old quarter mount from ceiling
-Rehung quarter mount above Qing ovens to the back right (closer to oven side)
-Mounted bakery monitor and computer
- installed bump bar and printer (printer not plugged in but has cable)
-Put up fry station mount
-Installed monitor to fry station mount and hooked up
-Daisy chain ran from fried to fry
-Fried monitor and computer installed with bump bar installation
-2 Ethernet cables ran from both computers to the office rack marked with electric tape
|
| 195 | Jim | 02/25/2023 | 17371 | Called out to repair and re- install faucet system for
Rear sink
While I was cleaning up after completing the repair a fry bulb exploded and I took the fry bin to the sink and cleaned it out.
|
| 194 | Jim | 02/24/2023 | 00596 | Installed three electrical chassis' for E Production system
And ran MX cable through out plus one outlet for the baking station
Need to connect wiring |
| 193 | Waylon | 02/23/2023 | 18198 | -2 monitors mounted for eproduction
-Bake monitor holder moved
-Replaced ceiling tiles
-Cut ceiling tile for bake monitor bracket
- took out and installed office camera |
| 192 | Waylon | 02/23/2023 | 04956 | -Replaced 5 UHC strips (old cabinets) |
| 191 | Brendan | 02/23/2023 | 17371 | -lemonade flavor change: sanitized, installed, calibrated
-worked some magic on kvs2 monitors. Pain it the butt |
| 190 | Brendan | 02/23/2023 | 00596 | -troubleshooted ped15. Found bad network cable missing the retaining clip. Swapped out with working one from dual point extender. Will bring replacement on next visit |
| 189 | Brendan | 02/23/2023 | 18198 | -lemonade flavor change: sanitized, calibrated, installed
-installed a return vent |
| 188 | Jim | 02/23/2023 | 12272 | Steam Clean slop sink drain and applied epoxy to seal from leaking
Replaced right side drain gasket on main sink
Epoxied left side drain and trap plug
All repairs checked and no leaks
Drilled and tapped electrical panel door and hinges, installed machine screws/ door operational and meets code |
| 187 | Brendan | 02/22/2023 | 04956 | -repaired dt window which chain fell out
-lemonade flavor change: sanitized, installed, calibrated. Store missing label kit |
| 186 | Jim | 02/22/2023 | 04205 | Replaced hot handle hand sink upon entering from public area
Replaced hot cartridge and handle on middle faucet at the main sink
Replaced complete faucet on right side of the main sink
Relayed status of rear door to Brendan I advised the manager to have someone go outside and if needed kick the lower right corner of the door to set it into he frame. No light or draft
Replaced CO2 gauge on main tank |
| 185 | Brendan | 02/22/2023 | 00596 | -troubleshooted McFlurry mixer. Motor seized causing fuse to trip. New motor on order
-looked at filet water line, unrepairable. New kit on order
-corrected issues with kvs1 and kvs4 printers
-lemonade install: sanitized lines, install, calibration. Machine missing bib tray and nozzle. On order |
| 184 | Waylon | 02/22/2023 | 18198 | -Dropped ceiling lights
-Finished cutting and wiring speaker
-took apart electrical box for emergency light (needs new outer casing ordered)
-caulked back dish sink
-started eproduction installation
-quarter monitor moved above grill bump bar installed
-installed mounts for fried products and fry station |
| 183 | Brendan | 02/22/2023 | 02830 | -replaced cbb monitor
-crimped new connector on dt runner bump bar
-lemonade install: sanitized lines and calibrated
-investigated ABS ice machine issues. Refrigeration issue, referred to Rick.
-investigated leak by ABS, coming from ABS. Referred to Rick |
| 182 | Brendan | 02/22/2023 | 18198 | -ABS ice gate error; replaced ice gate all set
-troubleshooted network issue with kvs6. Found issue, corrected.
-troubleshooted DoorDash tablet connectivity issues
-got a start on eproduction |
| 181 | Brendan | 02/22/2023 | 10544 | -troubleshooting system issues. Business day was combined, best to leave it alone |
| 180 | Jim | 02/22/2023 | 18198 | Hooked up two fire detectors in new ceiling tiles
Contacted fire and pelmac before and after work
System all clear and ready |
| 179 | Jim | 02/22/2023 | 18198 | Completed and tested E Production system electrical all set
Panel AP-2. Breaker # 10
|
| 178 | Jim | 02/21/2023 | 18198 | Setting up E production system
Removed two broken bulbs
Replaced three fry light bulbs
|
| 177 | Waylon | 02/20/2023 | 18198 | Tied up all ceiling and lights
Removed a bunch of ceiling tiles
Took out cameras and fire alarms
-helped them start the store when I got there |
| 176 | Jim | 02/20/2023 | 18198 | Raise cords and hoses in ceiling for new ceiling grid install |
| 175 | Jim | 02/20/2023 | 04956 | Repaired old mailbox post and mounted new mailbox at office |
| 174 | Jim | 02/20/2023 | 18198 | Steam clean and Grout Drive thru area
Caulk rear sink and Re glue rear sink left drain pipe
|
| 173 | Brendan | 02/20/2023 | 25383 | -ran new water line to OJ and installed
-replaced ABS grabber block
-repaired another burst water line @ tea brewer |
| 172 | Waylon | 02/17/2023 | 21582 | -Eproduction installation
-Bakery mount moved
-Monitor installed
-Tiles replaced and cut |
| 171 | Brendan | 02/17/2023 | 02830 | -completed eproduction installation
-looked at shake machine not dispensing ice cream. barrel was frozen solid and pump gasket was bad. replaced pump orings and thawed barrel
|
| 170 | Jim | 02/17/2023 | 00596 | Cleaned and flushed w/ hot water lobby drink station sump pump
Replaced outlet for rear nugget freezer |
| 169 | Jim | 02/17/2023 | 18198 | Removed and replaced broken baseboard tiles
Need more corner tiles Brendan ordering |
| 168 | Jim | 02/17/2023 | 10622 | Removed and replaced sink spray head and flex hose |
| 167 | Brendan | 02/16/2023 | 02038 | -replaced delivery monitor |
| 166 | Waylon | 02/16/2023 | 21582 | Eproduction 2/3 set up just need bake mount and monitor
-fried products just needs a bump bar
-help Jim move freezer to dumpster |
| 165 | Jim | 02/16/2023 | 00596 | Replaced crash bar on delivery door ( old door did not secure door anymore)
Also cleaned drain on beverage service machine in public area
|
| 164 | Jim | 02/16/2023 | 04205 | Rearranged section in storage unit and put vertical two cabinet fridge w/glass display door in there until the repair parts come in.
Parts are ordered. |
| 163 | Jim | 02/16/2023 | 07194 | Checked water filter for CO2 machine- OK changed 10/22
Steam cleaned caster wheels on island equipment
|
| 162 | Brendan | 02/15/2023 | 04956 | -drained multiplex, moved back, filled again. Planning to relocate accumulator tank and backup co2 tanks, need to order line for it |
| 161 | Jim | 02/15/2023 | 07194 | Removed and relocated vertical two cabinet fridge
Delivered to Goffstown and removed their vertical two cabinet fridge with the top section is a glass display door
|
| 160 | Jim | 02/15/2023 | 17371 | Replaced four fry sockets and wiring needed repairs
Removed Fry Bin to find out why it wouldn't sit in the cabinet level
The bun is twisted slightly so when placed in the cabinet to use,
The right front side was up about 1/2' off the cabinet.
I drilled ,tapped,and installed a stainless machine screw for eaze of access.
|
| 159 | Jim | 02/15/2023 | 10622 | Diagnosed and repaired motion flush system (Zurn brand)
In Men's room and Ladies room
|
| 158 | Brendan | 02/15/2023 | 10544 | -corrected receipt printer issues
-replaced 3 receipt printers
-calibrated ABS ice
-shuffled stuff around and installed juice machine. Will return to plumb up and calibrate when water line arrives.
-fixed FC PED issues
-measured and ordered pre-rinse faucet |
| 157 | Brendan | 02/15/2023 | 07194 | -attempted to repair prep fridge door, no luck, multiple parts stripped. Jim will bring new fridge this afternoon
-replaced UHC switch
-temporarily fixed DT railing |
| 156 | Waylon | 02/15/2023 | 02830 | -Moved old quarter mount to bakery monitor location
-Installed bake monitor and computer
-Ran printer cord to label maker |
| 155 | Jim | 02/14/2023 | 02830 | Replaced two belts on bun toaster
|
| 154 | Jim | 02/14/2023 | 12272 | Replaced breaker #12 in Panel AP -4
Remove and replace locking door knob on outside electrical closet |
| 153 | Brendan | 02/14/2023 | 17371 | -repaired blown up co2 line @ BIM
-replaced side 1 breakfast monitor
-music player upgrade |
| 152 | Waylon | 02/14/2023 | 07194 | -installed new hinge for kitchen fridge (door is still not fully shut Ty)
-Replaced grill ceiling tile
-new Board in UHC cabinet closest to HLZ
|
| 151 | Brendan | 02/14/2023 | 04956 | -fixed leaky shutoff behind coffee brewer
-calibrated left coffee brewer
-installed lobby music media player |
| 150 | Waylon | 02/14/2023 | 07417 | -reenforced flush filter hose secured to the wall include pcp pipe |
| 149 | Jim | 02/14/2023 | 04205 | Installed fry freezer all working fine |
| 148 | Jim | 02/14/2023 | 25383 | Dropped rack system off at Milford |
| 147 | Jim | 02/14/2023 | 07194 | Picked up fry freezer for Second street and rack system for Milford
|
| 146 | Waylon | 02/14/2023 | 18198 | -Grouted up front drive thru (just needs touch up waiting for grout to dry)
-Replaced door locking mechanism
-Tighten back sink knobs stopped dripping on one side
-Put silicone on tube to stop dripping on other side of sink |
| 145 | Brendan | 02/14/2023 | 12272 | -showed Kris how to change new toaster belts
-replaced cbb monitor
-replaced left coke tank dispense port
|
| 144 | Waylon | 02/13/2023 | 00596 | -Filled all curbside signs with 150 Lbs of sand
-Rehung 3 curbside signs to post
-Positioned post for correct spots
-relocated plow pole |
| 143 | Brendan | 02/13/2023 | 07194 | -attempted to replace freezer gasket
-replaced coffee brewer temp probe, level probe, and dry plug harness
-removed stuck key in detex
-ordered door hinge for prep fridge |
| 142 | Jim | 02/13/2023 | 18198 | Replaced two light bulbs in customer area
Steam clean and grout tiles in front of slop sink and 3 sink wash station
|
| 141 | Waylon | 02/13/2023 | 18198 | -Installed 3 new cabinet strips (2 arrow) (1 hour glass)
-Cleaned up front drive thru just needs grout placed |
| 140 | Brendan | 02/11/2023 | 18198 | -traced issue with breaker #22. Abandoned double tapped wire causing too much amp draw. Disconnected from breaker to solve issue. |
| 139 | Jim | 02/10/2023 | 02830 | Removed broken fry bulb from socket and installed new bulb
Had to remove another bulb that was broken
Mary said she would order new bulbs |
| 138 | Jim | 02/10/2023 | 04205 | Started to set up the hardware for the e production system
Tried to set men's room toilet three times but still leaks from drain called paradigm
|
| 137 | Jim | 02/10/2023 | 00596 | Cut up fallen tree and placed in dumpster
|
| 136 | Jim | 02/10/2023 | 04205 | Working on men's room toilet seal needs new seal in floor work on going
Needed to leave to get truck inspected at kerners
|
| 135 | Brendan | 02/09/2023 | 07417 | -tied in drain tube to filter. PVC straps broke, will return another day |
| 134 | Brendan | 02/09/2023 | 04956 | -mourned fc card readers
-fixed fc Expo 2 printer issues
-removed fry bulb from socket
-cleaned all trash and stuff out of crew room and stock room
-replaced leaky bulk coke nozzle at fill box |
| 133 | Waylon | 02/09/2023 | 07417 | - drain hose rain through ceiling now is just waiting on adapter
-(hose should be adjusted to wall with big zip ties to look suitable) |
| 132 | Jim | 02/09/2023 | 21582 | Completed and checked the historical data system
Replaced the weather striping around delivery door
Reworked rear door latch - door now latches on its own
|
| 131 | Brendan | 02/09/2023 | 17371 | -repaired leaky shutoff by coffee pot
-coffee maker not filling water, replaced fill valve, all set
-replaced orings on leaky filet steamer
-adjusted backup co2 gauge to proper pressure |
| 130 | Waylon | 02/09/2023 | 21582 | -Qing oven installed HV board and new transformer
-New problem the display board is not receiving any power I believe it's a bad HV board or the display board is bad, Brendan is going to investigate further |
| 129 | Waylon | 02/09/2023 | 02038 | -Replaced 2 UHC strips
-Fixed light ballast was replaced
-Found UHC outlet was dead checked breakers |
| 128 | Jim | 02/08/2023 | 21582 | Installed RTI outlet checked and good to go
Installed chases and electrical for eproduction |
| 127 | Jim | 02/08/2023 | 02830 | Install new quick- clip fitting in water in fo the frappe machine.
Checked for leaks all good
|
| 126 | Brendan | 02/08/2023 | 21582 | -replaced leaky bulk co2 fill port
-replaced board, fill probes, temp probe, membrane, decal, faucet lever @ axiom brewer. Calibrated tested
-ordered a bunch of clips for ABS cup tubes
-fixed cream dispenser not temping |
| 125 | Waylon | 02/08/2023 | 07417 | -Removed leaking drain hose from ceiling
-Fixed UHC cabinet switch
-coming back tomorrow for adding a new drain hose |
| 124 | Brendan | 02/08/2023 | 25383 | -replaced computer @ HLZ side 2
-repaired leaky fitting behind BIBs
-replaced cbb monitor
-ordered ABS grip arm assembly
-ordered print head for FFLS |
| 123 | Waylon | 02/08/2023 | 02830 | -Grill monitor moved to chassis
-2/3 of eproduction monitors installed and mounted did not do bakery
-Ethernet cables are ran for bakery and fried product monitors
|
| 122 | Brendan | 02/08/2023 | 07194 | -eProduction post-install setup |
| 121 | Brendan | 02/07/2023 | 07194 | -finished installing eProduction
-replaced ice bank control @ multiplex
-replaced right Diet Coke valve
-diagnosed right coffee brewer. Needs new probes, on order
-replaced pos2 cash drawer |
| 120 | Waylon | 02/07/2023 | 07194 | -Eproduction installation (Grill mount moved, Bakery mount put in)
-All computers hooked up and running
-Light lens replaced |
| 119 | Brendan | 02/07/2023 | 18198 | -installed replacement smart clock |
| 118 | Brendan | 02/06/2023 | 07417 | -painstakingly retrieved camera footage
-installed new DVR system |
| 117 | Jim | 02/07/2023 | 02038 | Replaced chain assembly for DT window # 2
Stopped by londonderry to get DT window info for Brendan |
| 116 | Jim | 02/06/2023 | 02038 | Cut rear sink drain and installed air gap separation |
| 115 | Jim | 02/06/2023 | 12272 | Installed thread lock on nuts holding dual glass windows at DT #2
And reinstalled left trim cover other cover missing |
| 114 | Jim | 02/06/2023 | 07194 | Finish caulked two rear sinks
Installed per tubing on hot water heater blow off valve to direct to floor drain |
| 113 | Waylon | 02/07/2023 | 18198 | -Lee 1+2 signs are hung up |
| 112 | Waylon | 02/06/2023 | 07194 | Fixing up painted floor mess |
| 111 | Waylon | 02/06/2023 | 07417 | -diagnosed UHC not working part is ordered bad switch
-Downloading camera footage |
| 110 | Brendan | 02/04/2023 | 17371 | -went for both coffee brewers not working. Found frozen waterlines. Went it the ceiling to find a big hole in the drywall with no insulation on the exterior wall causing the ceiling to get below freezing. Ordered pipe warming lines and will insulate areas of ingress. In the meantime, I showed how to brew hot coffee using the tea brewer. |
| 109 | Jim | 02/03/2023 | 07194 | Traced wiring issue with electrical for historical data system
Remove and replace caulking around main sink |
| 108 | Brendan | 02/03/2023 | 21582 | -went to diagnose coffee brewer. Bad board, didn't have the right one on the truck so had to order. Will also proactively replace level probes as they are very corroded |
| 107 | Brendan | 02/03/2023 | 04205 | -fixed all frappe issues. Replaced UVC board with upgrade kit. Replaced water regulator. Calibrated. |
| 106 | Brendan | 02/03/2023 | 10544 | -went for leak at booster pump. Found pinhole in bypass valve, replaced. Also found many minor leaks from old tubing. Ram out of tubing will order more and be back |
| 105 | Jim | 02/03/2023 | 04956 | Raised high capacity freezer and mounted to wall
|
| 104 | Jim | 02/02/2023 | 07194 | Repair cornerbead entry to break room
Sand drywall as needed multiple areas
Clean & Re -Caulk the perimeter of the slop sink
Secured CO2 tank to floor
Upgraded safety chains and anchors to mobile CO2 tanks
|
| 103 | Waylon | 02/02/2023 | 07194 | -Paint stock room
-2 door fridge not closing properly
-bun toaster making noises
|
| 102 | Brendan | 02/02/2023 | 04956 | -moved fry monitor down a few spaces to avoid neck strain '?
-tweaks to eproduction |
| 101 | Brendan | 02/02/2023 | 07194 | -diagnosed tea brewer not dispensing dilute water. Multiplex was freezing waterline.
-diagnosed multiplex issues. Found ice bank control probe was incorrectly located. It should be located on the front right, instead I found it in the rear. Which is why the multiplex is icing up. Turned off refrigeration to let the ice melt. Will be back tomorrow after ice melts to put in the proper location, as well as replace the probe as a precautionary. Also found a very small leak on the tee between the carb pump inlets. Will take care of that during new filter installation.
-investigated co2 tank gauge issue. Fill gauge was not working because the economizer valves were shut off. Turned valves on and gauge moved up. Store to follow up with co2 company if gauge continues to be innacurate (tank is their property)
-checked for co2 leaks. Tank had very minimal ice build up. No more than what I would expect for a peak period. Turned off shutoffs and monitored gauges, no drops, which confirms none of the stores equipment or lines is causing a leak. Also inspected the fill box for leaks, none present. If a leak is still suspected, store can follow up with co2 company to inspect their tank.
-installed what I could for eProduction. Still waiting on some electrical
-filtered, scrubbed, and replaced oil in fry vat 1. After I dropped a power cable wrapped in plastic in the vat, the oil was full of cancer causing microplastics'?
-put pos2 and pos14 hard drives in correct places, both up and running
|
| 100 | Brendan | 02/02/2023 | 04205 | -called for oven not staying closed and sounding very loud. Found ball detent had become dismantled. Reassembled and replaced spring. Adjusted latch. Noise caused by blower motor and blade. Bent it out a bit do get it to quite down. |
| 99 | Brendan | 02/02/2023 | 02038 | -went for ABS saying cup a full. Just dirty clear cup inserts. Ordered a new sensor so won't have to use the inserts.
-looked into fry hopper not dispensing properly. Found the doors open and close too quickly. Couldn't find any technical info on that model. Called Franke but waiting for a call back. |
| 98 | Jim | 02/02/2023 | 07194 | Repair cornerbead entry to break room
Sand drywall as needed multiple areas
Clean & Re -Caulk the perimeter of the slop sink
Secured CO2 tank to floor
Upgraded safety chains and anchors to mobile CO2 tanks
|
| 97 | Jim | 02/01/2023 | 02830 | Completed historical data system electrical connections
Computer Only Panel
Breaker # 3 |
| 96 | Brendan | 02/01/2023 | 00596 | -called for filet steamer down. Plugged in and was working fine. Tested
-replaced cbb printer cable |
| 95 | Brendan | 02/01/2023 | 04205 | -investigated leaks up front area:
'Replaced ABS drain fitting
'other leak coming from bad regulator @ BIM. new regulator on order, disconnected water for now. Frappe also stuck frozen, need to replace UVC board. On order.
-ordered new cartridge and handle for dish sink |
| 94 | Waylon | 02/01/2023 | 00596 | -Filet steamer up and running
-Replaced printer cord |
| 93 | Waylon | 02/01/2023 | 04205 | -Adjusted mixer valve on hand wash sink near fry station
-Fixed abs leak needed drain tube attached
-ordering new dish was sink handles
-diagnosed leak from McCaf?? machine |
| 92 | Waylon | 02/01/2023 | 17371 | -biscuit oven contractor fixed
-diagnosed dt air heater parts ordered
-Abs was tripping breaker tied into another breaker to hold the load
-ped network problems
-Put together office chair |
| 91 | Brendan | 02/01/2023 | 17371 | -replaced contractor in biscuit oven
-troubleshooted ped6 network issues
-troubleshooted ABS breaker kept tripping. Bad breaker. Tied it in to another breaker until I get replacement
-assembled office chair
-diagnosed air curtain needs new switches, melted from bad contact |
| 90 | Jim | 01/31/2023 | 02830 | Installed RTI outlet
Installed two power posts for historical data system
Reset front hand sink temp |
| 89 | Jim | 01/30/2023 | 02830 | Work on adjusting water temp for sink by Drivethru |
| 88 | Jim | 01/30/2023 | 21582 | Installed three vertical power units |
| 87 | Jim | 01/30/2023 | 07194 | Completed historical daft system electrical connections
Panel AP-3 breaker #13 |
| 86 | Jim | 01/27/2023 | 07194 | Completed electrical for historical fast system |
| 85 | Jim | 01/27/2023 | 04956 | Finish securing wall mount for freezer
|
| 84 | Jim | 01/26/2023 | 02830 | Attach fitting for frappe machine
New fitting defective Brendan is ordering new one |
| 83 | Jim | 01/26/2023 | 04956 | Set up small freezer
Installed wall mount for freezer |
| 82 | Jim | 01/26/2023 | 10622 | Re -caulk slop sink drain
Grout around slop sink before inspection |
| 81 | Jim | 01/25/2023 | 17371 | Re install men's room mirror
Grout wall tiles in ladies room |
| 80 | Jim | 01/25/2023 | 10622 | Grout in and around slop sink
Grout in front of the ice maker |
| 79 | Jim | 01/24/2023 | 10622 | Grout in front of sink |
| 78 | Jim | 01/24/2023 | 18198 | Installed outlet for RTI system |
| 77 | Jim | 01/23/2023 | 02830 | Grout tiles in multiple areas |
| 76 | Jim | 01/23/2023 | 18198 | Start install of RTI outlet
Grout baseboard tiles in multiple areas |
| 75 | Jim | 01/20/2023 | 10622 | Applied epoxy to freezer floor for new bolt
Cut and placed tiles in various locations
Caulked transition at mcCafe station
Installed temp light in Drive Trhru upper cabinet |
| 74 | Jim | 01/19/2023 | 10622 | Grout multiple areas of floor
Tighten cola tank to floor
Remove broken fridge unit
Install safety chain for portable CO2 tanks |
| 73 | Jim | 01/19/2023 | 07417 | Finish install of outlets for RTI system
Breaker #14 In panel top right |
| 72 | Brendan | 01/31/2023 | 10544 | -repaired lobby door handle falling off
-replaced trash door knob with handle (NRBES)
-crimped new connector on 3po monitor
-replaced light ballast by office
-ran eProduction network wire |
| 71 | Waylon | 01/31/2023 | 10544 | -Eproduction wires ran
-Front lobby door handle fixed
-bump bar to delivery monitor
-Back door knob switch to handle
-Light ballast |
| 70 | Waylon | 01/31/2023 | 10622 | -Worked on toilet sensors (women's toilet needs new button & men's toilet ordering new piston, sensor, and solenoid because what we ordered decided to not work. Still figuring out what's actually wrong with it |
| 69 | Brendan | 01/31/2023 | 10622 | -worked on repairing toilets. Lady's room needs new manual override button |
| 68 | Brendan | 01/30/2023 | 25383 | -repaired tea brewer dilute line that exploded
-looked into OJ machine. Will be ordering new line to replace the collapsed line
-repaired leaky handsink, replaced orings |
| 67 | Brendan | 01/30/2023 | 04956 | -eProduction
-repaired side 2 HLZ, replaced fuse
-adjusted bathroom sink temps |
| 66 | Waylon | 01/30/2023 | 25383 | -Tea brewer water line
-Grill faucet needed new washers and is working |
| 65 | Waylon | 01/30/2023 | 04956 | -Eproduction fully set up just needs data pulled
-Bathroom water cold (mixer valve adjusted)
-Landingzone fuse replaced running |
| 64 | Jim | 01/16/2023 | 21582 | tiled by sink and bun rack |
| 63 | Jim | 01/16/2023 | 07194 | replaced fry sockets |
| 62 | Jim | 01/18/2023 | 07417 | Installed automist outlet |
| 61 | Jim | 01/18/2023 | 04205 | Installed outlet for automist |
| 60 | Jim | 01/17/2023 | 04205 | worked on electrical for eproduction |
| 59 | Jim | 01/17/2023 | 12272 | -Replaced ladies toilet
-replaced fry sockets |
| 58 | Brendan | 01/27/2023 | 17371 | -called for fry hopper tripping breaker. Found compressor dead. Disconnected refrigeration so they could use it to dispense.
-looked into multiplex, will order parts. Non urgent |
| 57 | Waylon | 01/27/2023 | 17371 | -Fry hopper compressor is down no refrigeration but working
-Multiplex part ordered
|
| 56 | Brendan | 01/27/2023 | 10544 | -replaced delivery monitor
-replaced exit device end cap
-installed 3 dual toilet paper holders
-ordered handle for lobby door
-ordered lockset for rear door
-removed key from back detex
-ordered headset batteries
-ordered light ballasts |
| 55 | Waylon | 01/27/2023 | 10544 | -New delivery monitor installed
-3 toilet paper dispensers mounted
-ordered new ballast
-Took out key in back door
-Exit device end cap
|
| 54 | Brendan | 01/27/2023 | 02830 | -went to install frappe water connector. Part was defective
-adjusted hand sink to proper temp
-fixed issue with fc Expo 2 |
| 53 | Waylon | 01/27/2023 | 02830 | -Sink mixer valve adjusted (temp at 105)
-Frappe water inlet (machine still down) |
| 52 | Waylon | 01/26/2023 | 07417 | -Pulling camera footage (many freezing problems) |
| 51 | Jim | 01/13/2023 | 07194 | -ran electrical for eproduction to panel |
| 50 | Jim | 01/12/2023 | 07194 | -got a start on eproduction, mounted vertical chase attached to vent stacks |
| 49 | Jim | 01/12/2023 | 04205 | -replaced wax ring on toilet, had to run out to get flange repair kit |
| 48 | Jim | 01/11/2023 | 00596 | -major grout work done all over store |
| 47 | Jim | 01/11/2023 | 04205 | -installed automist receptacle |
| 46 | Jim | 01/11/2023 | 21582 | -replaced fry bulb sockets, had to go to shop for supplies |
| 45 | Jim | 01/10/2023 | 21582 | -filled large crack in stockroom |
| 44 | Jim | 01/10/2023 | 17371 | -grouted remaining tiles, re-replaced tiles that have fallen |
| 43 | Jim | 01/09/2023 | 10622 | -finished up electrical and tied into panel |
| 42 | Jim | 01/06/2023 | 21582 | -worked on tiling various spots around the store
-looked at large tile crack by the rear door, due to foundation sagging. Will need to fill it with epoxy or something similar |
| 41 | Jim | 01/05/2023 | 10622 | -worked on installing eproduction electrical |
| 40 | Jim | 01/04/2023 | 17371 | -finished tiling bathroom and back of house and grouted |
| 39 | Jim | 01/03/2023 | 17371 | -tiling bathroom and back of house |
| 38 | Brendan | 01/26/2023 | 07417 | -worked on pulling camera footage. DVR is having many issues with freezing. Was able to pull 2 cameras worth. New DVR on order |
| 37 | Brendan | 01/26/2023 | 04956 | -worked on installing eProduction
-replaced drain pan @ BIM |
| 36 | Waylon | 01/26/2023 | 04956 | -Two monitors mounted for eproduction
-Frappe waste cleaned out |
| 35 | Brendan | 01/26/2023 | 00596 | Investigated ceiling leak. Drains on roof are clear and working. Checked in the ceiling where it was coming from. Problem with the roof. Roofers will be out today |
| 34 | Waylon | 01/26/2023 | 00596 | -leaking ceiling looked at called Michael |
| 33 | Waylon | 01/25/2023 | 12272 | -fixed frappe connector
-Fixed qingoven
-fixed dish sink leaking
-Fixed coffee brewer not filling |
| 32 | Brendan | 01/25/2023 | 12272 | -replaced frappe water hose
-repaired left coffee brewer. Replaced temp probe and liquid level probe
-fixed qing oven no power, breaker was turned off |
| 31 | Brendan | 01/25/2023 | 10622 | -replaced other fry dispense door
-replaced dogging mech on dt side door
-moved HOTG monitor to proper location
-adjusted epr settings
-replaced two ladies room faucets
-loaded updated menudata.xml onto label printer
-replaced ladies room stall sensor and solenoid. Traded with men's room. Parts still on order |
| 30 | Brendan | 01/24/2023 | 10622 | -replaced one of the fry dispense doors
-Women's bathroom toilet sensor diagnosis
-tried fixing sink, no luck. bought new faucets to be installed tomorrow |
| 29 | Waylon | 01/25/2023 | 10622 | -Fixed ladies bathroom flush sensor swapped with men's
-Remounted and moved quarter pounder monitor
-Cut and replaced old ceiling tile
-Reprogrammed sticker machine (latest software)
-Replaced door lock (from another store)
-Replace fry dispenser doors ( dremeled out) |
| 28 | Waylon | 01/24/2023 | 10622 | -Drilled out fry hopper (open/close wings)
-Women's bathroom toilet sensor tried replacing it was broken and gonna fix again tmrw after tried to rewire the old sensor
-tried fixing sink bought new faucets for tommorow |
| 27 | Waylon | 01/24/2023 | 21582 | -Diagnosed Qing oven (needs either new transformer or circuit board) both ordered
-reset office computer |
| 26 | Brendan | 01/24/2023 | 21582 | -corrected office computer wiring
-diagnosed Qing oven. Bad HV board. New on order |
| 25 | Jim | 01/24/2023 | 18198 | Installed outlet for RTI misting system |
| 24 | Brendan | 01/24/2023 | 18198 | -many system issues. Need to do ER3 |
| 23 | Waylon | 01/23/2023 | 18198 | -Grouted front drive thru
-Grouted left and right side of walk in door
-Grouted opposite wall of ice maker
-helped jim with eproduction (electrical)
|
| 22 | Waylon | 01/23/2023 | 18198 | Cabinet strip
Eproduction started |
| 21 | Brendan | 01/21/2023 | 18198 | -installed speaker system
-connected headset base station to network |
| 20 | Waylon | 01/21/2023 | 18198 | Eproduction wire |
| 19 | Waylon | 01/21/2023 | 04956 | -speakers setup |
| 18 | Brendan | 01/20/2023 | 10622 | -went to Queen City glass to pick up repaired mirror
-installed men's room mirror
-installed parabolic mirror in crew room
-fixed issue with Qing oven noise
-investigated kiosk light pole. Needs to order parts
-looked at toilet sensor not working. Found shorted wires causing it to melt. New sensor on order
-Attempted to replace fry hopper doors, screws stripped. Will return to drill out in the morning
-repaired coke valve in lobby, new microswitch
-adjusted eProduction settings |
| 17 | Waylon | 01/20/2023 | 10622 | -Installed mirror (covers co2)
-right side Qing oven fixed can was hitting side wall
-bump bar button replaced from old spare
-mirror from Queen City put back
-programmed eproduction |
| 16 | Jim | 01/20/2023 | 10622 | Applied epoxy to freezer floor for new bolt
Cut and placed tiles in various locations ( to be grouted Monday)
Caulked transition at McCaf?? area
Installed temp light at DT upper refrigerator
|
| 15 | Jim | 01/20/2023 | 10622 | Applied epoxy to freezer floor for new bolt
Cut and placed tiles in various locations ( to be grouted Monday)
Caulked transition at McCaf?? area
Installed temp light at DT upper refrigerator
|
| 14 | Waylon | 01/20/2023 | 07417 | -Abs bushings
-Ordered hose for ceiling |
| 13 | Waylon | 01/20/2023 | 18198 | -Installed new UHC button strip
-Planned for Shake machine outlet secure
-Tighten fry bulb (flickering)
|
| 12 | Jim | 01/19/2023 | 10622 | Grout multiple areas of floor
Tighten spare cola tank to floor
Remove small fridge and broken pie storage unit
Installed safety chain for CO2 movable tanks
|
| 11 | Jim | 01/19/2023 | 07417 | Completed install of 220 V outlet for RTI cleaning system |
| 10 | Brendan | 01/18/2023 | 02038 | -lobby sodas not giving soda water, replaced carb level probe harness
-hi-c not dispensing syrup, replaced armature tip
-tried replacing fridge door, incorrect door packed |
| 9 | Waylon | 01/18/2023 | 02038 | -Fixed multiplex
-Replace Hi C lobby (red cap) |
| 8 | Brendan | 01/18/2023 | 25383 | -fixed ABS issues. Cup holder was missing magnet, replaced. Also replaced lift cylinder shroud as to stop it from stalling.
-adjusted thermostats
-ordered barrel for fry hopper right side |
| 7 | Waylon | 01/18/2023 | 25383 | -Fixed abs (new cup due to magnet broken in old)
-Diagnosed fry hopper (Barrel needs new)
-Fixed thermostat settings |
| 6 | Waylon | 01/17/2023 | 04205 | -Installed new office computer
-installed 3 new cabinet strips on side 1 |
| 5 | Brendan | 01/17/2023 | 04205 | -replaced 3 UHC strips
-replaced RHS
-ordered new exit device for rear door
-ordered pistons for shake machine |
| 4 | Waylon | 01/17/2023 | 07194 | -Kiosk pole plate
-Frappe co2 leak
-New office computer
-FC drawer tilted bad close
-Lobby foot stool
|
| 3 | Waylon | 01/17/2023 | 07417 | Installed crew room camera
|
| 2 | Brendan | 01/17/2023 | 07417 | -installed camera in crew room |
| 1 | Brendan | 01/17/2023 | 07194 | -installed replacement BOS
-affixed kiosk light pole plate to ceiling
-affixed lobby stool foot rest
-fixed drawer closing issue
-fixed pos1 receipt printer issue
-fixed co2 leak, leaky oring on frappe
-corrected dual point display issue |